BAREFOOT PRINCESS

BAREFOOT PRINCESS is a 1996 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in February 2026, along with 17 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 20 February 2026.

Built
1996
Last inspected
20 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDN3771
507051
Flag
UNITED STATES
Maury page id
psix-507051

Inspections, by type

…with no type recorded3
Years with a record 9 calendar years (2016–2026)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 24.0 ft × 7.0 ft
Registered tonnagegross 72 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOWEN SHORT MARINE · BAYOU LA BATRE, AL, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it101 - Displacement, Ton
72 - Simplified, Gross Ton
57 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 18

20 February 2026 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8313422
25 November 2025 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8273314
19 November 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8271013
12 June 2025 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8158212
11 June 2025 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 8157675
26 March 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8100337
4 December 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8034325
29 August 2024 Internal Structural Exam · Plan Review "T" Boat · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7989342
7 July 2023 Administrative Inspection · Examination of Repairs · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7735850
25 October 2022 Type not recorded
No type recorded · Station Wrightsville Beach · USCG East District (CGD-E) · Activity 7583902
12 October 2022 Administrative Inspection · Inclining Experiment
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7574960
25 February 2021 Drydock Exam · Plan Review "T" Boat
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7148915
19 December 2018 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6600367
14 December 2017 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6324613
18 May 2017 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6149127
31 January 2017 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6075880
19 September 2016 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6004175
28 January 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5807268

Deficiency record · 17

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 November 2025 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel missed its annual inspection window deadline of November 15, 2025. The vessel is not authorized to operate until an annual inspection is conducted.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2025
Resolved 25 November 2025
Resolution: Completed Annual Inspection.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 12 June 2025 Resolved
The training program must address firefighting proficiency and must include, but need not be limited to—(1) Training in the use and location of firefighting equipment and general firefighting knowledge, including:(i) Location of firefighting appliances and emergency escape routes. Vessels crew was unfamiliar with location of portable fire extinguishers. The crew was asked to deploy personnel flotation devices for abandon ship and the crew could not demonstrate. Provide training and conduct satisfactory drills with CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2025
Resolved 12 June 2025
Resolution: Marine Inspector discussed fire, man overboard and abandon ship drills, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2025 Resolved
A vessel must carry one floating water light, unless it is limited to daytime operation, in which case no floating water light is required. Float light had a crack in body, repair/replace to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2025
Resolved 12 June 2025
Resolution: Water light replaced and tested, all sat.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 12 June 2025 Resolved
The official number of the vessel, preceded by the abbreviation “NO.” must be marked in block-type Arabic numerals not less than three inches in height on some clearly visible interior structural part of the hull. The number must be permanently affixed to the vessel so that alteration, removal, or replacement would be obvious. If the official number is on a separate plate, the plate must be fastened in such a manner that its removal would normally cause some scarring of or damage to the surrounding hull area. Vessel is missing Official number, replace to the satisfaction of CG Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 12 June 2025
Resolution: Official number was installed, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 March 2025 No resolution recorded
Violation of active COTP order.
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2023 Resolved
A fixed gas fire extinguishing system aboard a vessel must be approved by the Commandant ... Deck hatch and cable penetrations separating main deck from CO2 protected machinery space not adequately sealed; daylight observed through openings. Patch/fill openings appropriately to contain CO2 gas upon activation in an emergency. 46 CFR 181.410(a)(1) 701c
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2023
Resolution: Gasket installed on engine room hatch. Fire retardant material installed into cable through ways.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 15 August 2023 Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40. DAPI information missing for rotating deck hand personnel. Provide contract with deckhand supply agency concerning required chemical testing for all personnel working in safety sensitive positions. 46 CFR 16.201 701c
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2023
Resolution: Crew list provided reflecting enrollment into DOT approved testing facility.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 August 2023 Resolved
A hatch exposed to the weather may be weathertight...on a vessel that operates only on protected waters...a hatch cover must:(1)have securing devices; and (2)be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Replace gaskets on forward stbd hatches and fit with securing devices & chains as ID'd. 46 CFR 179.360(a)(3)& (b) 701c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2023
Resolution: Securing devices installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 August 2023 Resolved
Except as provided in § 173.17, no person may use a vessel to which this part applies unless: (1) It has a number issued on a certificate of number by the issuing authority in the State of principal operation; and (2) The number is displayed as described in § 173.27. Vessel not registered for Florida. Obtain Florida registration/ FL state number. 33 CFR 173.15 701c
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2023
Resolution: State of FL processing vessel registration.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2023 Resolved
New installations of electrical equipment and material, and the repair or replacement of wire and cable, on an existing vessel, which are completed to the satisfaction of the cognizant Officer in Charge, Marine Inspection (OCMI) on or after March 11, 1996, must comply with this part. String bulb-lights identified in multiple areas. Provide documentation these lights are marine-grade, or replace/remove as appropriate. 46 CFR 183.115(c) 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 November 2023
Resolution: String bulb lights replaced with marine grade.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2023 Resolved
All cable and wire must... be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Electrical wiring/cable routing lacking sufficient supports throughout multiple spaces. Install sufficient screw in cable supports to organize cable/wiring routing accordingly. 46 CFR 183.340(b)(4) 705 c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 November 2023
Resolution: Metal cable supports installed at identified locations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2023 Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Open cable penetration identified with multiple cables running from distribution panel in space forward engine room. Reroute single cables through own penetrations and enclose appropriately. 46 CFR 183.330(b) 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 November 2023
Resolution: Cable penetrations in fuel tank space rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2021 Resolved
The Marine Inspector may require any part or all of the propellor shafting to be drawn for examination whenever the condition of the shafting are in question. Draw port side tail shaft entirely for visual inspection.
Action required: 705 - Other - as specified
Resolved 10 May 2022
Resolution: Shaft renewed
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 July 2021 Resolved
Descale areas of corrosion on the deck for further inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 October 2021
Resolution: Pitting on deck was acceptable to not exceed .24". Deck was evaluated and calculations were submitted to MSC for deck allowable wastage.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 January 2017 Resolved
DSC equipped VHF-FM radio was not programmed with vessels MMSI numbers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 1 February 2017
Resolution: Attending Inspector verified programming of MMSI information into DSC equipped radio.
Engineering › Bilge Water Management System › Valve
Issued 31 January 2017 Resolved
Installed check valves in fixed bilge system are frozen/inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2017
Resolved 2 February 2017
Resolution: Attending Inspector witnessed operational test of vessels fixed bilge system from all spaces served. Test sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 31 January 2017 Resolved
Fixed CO2 system was not equipped with proper operating instructions for local/remote stations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 1 February 2017
Resolution: Attending Inspectors verified operating instructions (content/location).