← All vessels
DMI60
Freight Barge · Barge class · Built 1950s · USCG Northwest District (CGD-NW) · Other hulls named DMI60
DMI60 is a 1959 freight barge. The Coast Guard has recorded 34 inspections since 1985, most recently in January 2005, along with 30 deficiencies.
Records from 1985 to 2005. Most recent: inspection, 26 January 2005.
- Built
- 1959
- Last inspected
- 26 January 2005
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 30 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1051471
50706
Flag
UNITED STATES
—
Maury page id
psix-50706
Inspections, by type
…with no type recorded4
Years with a record
18 calendar years (1985–2005)
The 34 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 24.0 ft × 4.0 ft
Registered tonnagegross 48 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALBINA ENGINE & MACHINE · PORTLAND, OR, UNITED STATES · built 1959
Hull materialSteel
PropulsionElectric Motor
Hull shapeBox
Hull configurationMonohull
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 April 2026 · expires 30 April 2027
Service, as the file records itFreight Barge
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Simplified, Gross Ton
38 - Simplified, Net Ton
38 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 34
26 January 2005
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2281179
31 August 2001
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1458914
3 July 2001
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1067628
17 January 2001
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1061082
25 April 2000
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 816816
1 March 2000
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 816358
18 January 2000
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 814532
29 June 1999
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1081861
6 April 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1369111
24 March 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1414963
10 April 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1096031
4 March 1997
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1390458
8 March 1996
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 884758
30 August 1995
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1407540
7 June 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1185290
15 May 1995
Drydock Extension · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1460789
10 March 1994
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 856542
7 March 1994
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1458142
17 September 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 137142
15 May 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 145921
15 March 1993
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1385031
29 May 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 825953
17 April 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 958307
18 March 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 946671
15 March 1991
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1240402
15 March 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1242164
16 April 1990
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1211512
9 February 1990
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1230604
17 March 1989
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1208435
16 March 1988
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1297733
17 April 1987
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1327117
28 April 1986
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 990326
30 May 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1287371
4 April 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 982593
Deficiency record · 30
Fire Fighting
Issued 1 March 2000
Resolved
Develop training plan, conduct training, and maintain record of training inaccordance with 46 CFR 185.520 and 185.524 for monthly abandon ship, man overboard and fire-fighting drills.
Construction/Loadline
Issued 1 March 2000
Resolved
Pump hull dry, ventilate and obtain Marine Chemist certificate for entry bymarine inspector to complete internal exam.
Lifesaving
Issued 1 March 2000
Resolved
Apply type II retro-reflective tape on new lifering.
Lifesaving
Issued 6 April 1999
Resolved
Properly label crew adult lifejacket(s).
Lifesaving
Issued 6 April 1999
Resolved
Properly label buoy & buoy light with vessel name.
Lifesaving
Issued 6 April 1999
Resolved
Provide asprin in first aid kit.
Fire Fighting
Issued 6 April 1999
Resolved
Properly label location of work shed B-II fire extinguisher.
Construction/Loadline
Issued 6 April 1999
Resolved
Provide a proper portable (manual) bilge pump with a 5 GPM capacity.
Lifesaving
Issued 6 April 1999
Resolved
Provide proper Drug & Alcohol program per USCG Regs - 46 CFR 16.
Electrical
Issued 6 April 1999
Resolved
Repair/replace P.A. system speaker on workshed.
Fire Fighting
Issued 6 April 1999
Resolved
Conduct servicing of B-II extinguisher located in workshed.
Lifesaving
Issued 6 April 1999
Resolved
Replace child lifejacket or change placard to "3 Child Life preservers".
Construction/Loadline
Issued 6 April 1999
Resolved
Replace deck hatch-cover gaskets as needed.
Documentation
Issued 4 March 1997
Resolved
PROVIDE FCC MARINE RADIO OPERATOR'S PERMIT FOR VESSEL MASTER.
Documentation
Issued 4 March 1997
Resolved
PROVIDE FCC SAFETY CERTIFICATE AND STATION LICENSE FOR VESSEL.
Electrical
Issued 4 March 1997
Resolved
PROPERLY LINE BATTERY BOX WITH SUITABLE MATERIAL.
Lifesaving
Issued 4 March 1997
Resolved
REVISE EMERGENCY PROCEDURES TO REFLECT PROPER ACTIONS.
Navigation
Issued 4 March 1997
Resolved
REPLACE OR PROPERLY CLEAN ALL NAVIGATION LIGHT LENS COVERS.
Lifesaving
Issued 4 March 1997
Resolved
PROVIDE ONE ADDITIONAL ADULT PFD TO BRING TOTAL TO 30. VESSEL IS LIMITED TO 28 PASSENGERS WITH ONE MASTER UNTIL COMPLETED.
Electrical
Issued 4 March 1997
Resolved
REPLACE OR REWIRE ALL IMPROPER ELECTRICAL INSTALLATIONS IN WORK CABIN AND PILOT HOUSE. REMOVE ALL IMPROPER SPLICES, LOOSE WIRES, DEADEND WIRES, AND WIRES UNACCEPTABLE FOR MARINE USE. HARDWIRE (WITH ACCEPTABLE CIRCUIT PR0- TECTION & POWER CONVERTERS) ALL EQUIP INTENDED FOR PERMANENT INSTALLATION.
Engineering
Issued 15 May 1995
Resolved
REPLACE PROPELLERS.
Construction/Loadline
Issued 15 May 1995
Resolved
REPAIR FRACTURES AT FOUR RAMP HINGES (TWO ON EACH RAMP END).
Accommodation/Occupational Safety
Issued 7 March 1994
Resolved
MAKE AIR RECEIVER AVAILABLE FOR TANK VISUAL EXAMINATION OR HYDROSTATIC_x001C_ TEST.
Accommodation/Occupational Safety
Issued 7 March 1994
Resolved
SHOW PROPER OPERATION OF AIR RECEIVER SAFETY RELIEF VALVE.
Electrical
Issued 18 March 1992
Resolved
SUBMIT ELECTRICAL ONE-LINE DIAGRAM FOR RECENTLY INSTALLED INCINOLET TOILET AND TWO HOUSE HEATERS.
Construction/Loadline
Issued 16 March 1988
Resolved
PROVIDE ADEQUATE VENTILATION FOR ALL VOID SPACES IN HULL BY MEANS OF GOOSE NECK VENTS WITH CHECK BALL FLOAT IN EACH END OR BY OTHER SUITABLE MEANS OF VENTILATION AT NEXT SCHEDULED DRYDOCKING.
Deck/Cargo
Issued 28 April 1986
Resolved
MODIFY PNEUMATIC GATES TO PROVIDE ADEQUATE VISIBILITY FOR OPERATOR.
Lifesaving
Issued 4 April 1985
Resolved
REPLACE WATERLIGHT FOR RING BUOY.
Unknown
Issued 4 April 1985
Resolved
REPLACE HAND BILGE PUMP.
Fire Fighting
Issued 4 April 1985
Resolved
PROVIDE TWO TYPE B-II PORTABLE FIRE EXTINGUISHERS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.