AWESOME FUN

AWESOME FUN is a 1999 passenger vessel (inspected). The Coast Guard has recorded 41 inspections since 2000, most recently in April 2026, along with 72 deficiencies.

Records from 2000 to 2026. Most recent: inspection, 20 April 2026.

Built
1999
Last inspected
20 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP4566
507138
Flag
UNITED STATES
368248550, 368355580
Maury page id
psix-507138

Inspections, by type

…with no type recorded1
Years with a record 23 calendar years (2000–2026)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 19.0 ft × 10.0 ft
Registered tonnagegross 82 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNAVIGATOR BOATS · ELMORE, AL, UNITED STATES · built 1999
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Simplified, Net Ton
82 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP4916MMSI 368248550 · active · compulsorily equipped · granted 22 March 2024, expires 22 March 2034 · licensed under a name not among this hull’s recorded names (not shown)
WDP4566MMSI 368355580 · active · compulsorily equipped · granted 1 March 2024, expires 1 March 2034 · licensed under a name not among this hull’s recorded names (not shown)
WDM9000MMSI 368248550 · cancelled · compulsorily equipped · granted 7 April 2022, cancelled 28 February 2024 · licensed under a name not among this hull’s recorded names (not shown)
WCZ9747MMSI 367464050 · expired · compulsorily equipped · granted 18 August 2010, cancelled 10 October 2020 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 41

20 April 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8332420
7 April 2025 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8100209
27 November 2024 Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8040856
1 March 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7872889
8 November 2023 Simplified Stability Test · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7822280
22 March 2023 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7654899
8 February 2023 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7634153
19 October 2022 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7588706
6 April 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7424312
16 February 2022 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7397423
4 February 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7136283
8 December 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7107443
21 January 2020 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6892925
1 October 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6825341
15 January 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6611051
6 December 2018 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6593054
19 October 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6565177
1 February 2018 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6344214
29 March 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6113647
6 December 2016 Deficiency Check · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6053558
22 March 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5837599
21 March 2014 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 4821248
14 March 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4816001
9 November 2010 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3879401
16 December 2009 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3646623
24 March 2009 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3436627
6 November 2008 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3354901
20 March 2008 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3163313
13 December 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3115170
17 January 2007 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2910767
7 March 2006 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2613483
14 June 2005 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2399113
27 December 2004 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2268097
8 November 2004 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2235308
6 October 2004 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2215785
18 December 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1965525
2 December 2002 Periodic Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1712968
9 October 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1687127
4 December 2001 Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1458026
5 October 2000 Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1369864
5 October 2000 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1448339

Deficiency record · 72

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 April 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Masthead navigation light was inoperable. Vessel is restricted to daylight operation only until repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 April 2025
Resolution: Deficiency cleared. Vessel provided video evidence of operational navigation light.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 March 2024 Resolved
At each subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following; all smoke and fire detection systems. Marine Inspector asked crew to test smoke detectors and the crew stated they had no way to test. Test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2024
Resolution: Vessel provided a copy of the fire alarm system inspection report provided by J & J Fire
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 March 2024 Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel. Marine Inspector observed mounting screws holding the railing to the deck to be loose. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2024
Resolution: Vessel was repaired with 1 inch long stainless steel Phillips head screws and tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 February 2023 Resolved
Each battery used in an item of lifesaving equipment, must be replaced during the annual inspection if the expiration of the battery has passed. While both operational, ring life buoy water light battery & port life float battery were expired. Vessel is limited to daylight operations only until batteries are replaced with unexpired batteries.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 24 March 2023
Resolution: lights replaced with LED lights
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 February 2023 Resolved
Each life jacket must be marked with Type 1 retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 14 adult life jackets and 7 children life jackets require renewed retroreflective material. The number of passengers is reduced to 22 adults, 0 children until the retroreflective material has been renewed to the satisfaction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 24 March 2023
Resolution: Retroreflective tape renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 February 2023 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, not limited to, approval series 160.112. 2 life jackets require new lights.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2023
Resolved 24 March 2023
Resolution: New lights installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 February 2023 Resolved
Each ring life buoy must be marked with Type II approved in 46 CFR 164.018 or other standard specified by the Commandant. Retroreflective material on ring life buoy is missing in places and needs to be renewed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2023
Resolved 24 March 2023
Resolution: Retroreflective tape renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 February 2023 Resolved
Each generator must have a nameplate attached to it containing the information required by Article 445 of NFPA 70, and for a generator derated in accordance with paragraph (b)(2) of this sector, the derated capacity. Generator missing derated capacity placard.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2023
Resolved 23 March 2023
Resolution: Received picture of generator derating placard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 February 2023 Resolved
All fiber reinforced plastic (FRP) vessels constructed with general purpose resins must be fitted with a smoke activated fire detection system of an approved type. Smoke detector in accommodation space missing cover and not operating as intended.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2023
Resolved 24 March 2023
Resolution: New smoke detector installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 February 2021 Resolved
Provide proof of valid FCC Station License.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 February 2021
Resolution: Received proof of valid FCC Station license.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 February 2021 Resolved
Make both engine room vent closures air tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2021
Resolution: Recieved proof of air tight vent closures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 February 2021 Resolved
Properly secure stern bilge pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2021
Resolution: Reveived proof of properly secured bilge pump
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 February 2021 Resolved
Provide a total of 3 fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2021
Resolution: Received proof of 3 fire buckets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 February 2021 Resolved
Provide an adequate portable hand pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2021
Resolution: Received proof of adaquate portable hand pump.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 4 February 2021 Resolved
Replace starboard life float water light lanyard.
Action required: 10 - Deficiency Rectified
Resolved 4 February 2021
Resolution: Lanyard renewed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 February 2021 Resolved
Isolate leak in deck bait boxes, identify extent of FRP delamination and provide a repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 February 2021
Resolution: Received repair proposal to repair delamnation to baid box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 January 2020 Resolved
Ensure all connections for newly installed LED Lighting are of the approved type and are housed in junction boxes.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 31 January 2020
Resolution: Received pictures of new installed junction box and installed with crimp style connectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 January 2020 Resolved
Main deck life ring buoy plug was missing. Replace life ring buoy with approved type
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 31 January 2020
Resolution: Received picture with new life ring buoy installed
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 January 2020 Resolved
Update light list, coast pilot, tide tables, and charts to ensure 2020 copies are on-board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 31 January 2020
Resolution: All new light lists, coast pilot, tide tables and charts were verified to be updated and on-board.
Construction/Loadline › Penetrations › Valve Flange
Issued 6 December 2016 Resolved
Generator through hull fitting handle broke off.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 5 January 2017
Resolution: Repaired handle.
Construction/Loadline › Hull › Side Shell
Issued 6 December 2016 Resolved
Bow has fiberglass damage called tabbing near bow showing cracks.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 5 January 2017
Resolution: Damage was repaired.
Construction/Loadline › Structures › Scupper
Issued 6 December 2016 Resolved
Bow bolts are replaced.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 5 January 2017
Resolution: Bolts were replaced.
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 6 December 2016 Resolved
Strut bearing worn down below 50 percent.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 5 January 2017
Resolution: Shaft was replaced.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 March 2014 Resolved
Ensure the original certificate of documentation is kept onbaord the vessel.
Action required: 705 - Other - as specified
Resolved 14 March 2014
Construction/Loadline › Hull › Side Shell
Issued 9 November 2010 Resolved
Repair 22 blisters in hull.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2010
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 9 November 2010 Resolved
Replace all shaft bearings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2010
Engineering › Steering Gear System › Rudder Bearing
Issued 9 November 2010 Resolved
Replace port rudder bearing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2010
Construction/Loadline › Penetrations › Valve Flange
Issued 16 December 2009 Resolved
Provide a suitable handle for closure of live well thru-hull located in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Lifesaving › Lifefloat › Float-free Link
Issued 16 December 2009 Resolved
Properly rig lifefloat weak links and line and provide 18 ft. on lifefloat light lanyard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 16 December 2009 Resolved
Repair leaks as marked in both the starboard and port main diesel engine exhausts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Stability › Unintentional Flooding › General
Issued 16 December 2009 Resolved
Repair damage to engine room hatch coaming.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Operations/Management › Drills/Instruction › Abandon Ship
Issued 16 December 2009 Resolved
Deckhands to demonstrate knowledge of making distress calls on VHF and SSB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 December 2009 Resolved
Tighten port and starboard foward rails.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 16 December 2009 Resolved
Replace (2) B-II devices noted to be perforated into the main shell structure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 6 November 2008 Resolved
Replace cutlass bearings on the port shaft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2008
Construction/Loadline › Hull › Side Shell
Issued 6 November 2008 Resolved
Repair marked fiberglass sections on port and starboard side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2008
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 6 November 2008 Resolved
Remove water in forward bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2008
Engineering › Steering Gear System › Rudder
Issued 6 November 2008 Resolved
Repack rudder posts on port and starboard rudders.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2008
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 20 March 2008 Resolved
Replace sign for maximum number of passengers allowed on upper deck.
Due 15 April 2008
Resolved 20 April 2008
Lifesaving › Lifefloat › Float-free Link
Issued 20 March 2008 Resolved
Replace weak link on forward life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 20 March 2008 Resolved
Recharge portable fire extinguisher in aft berthing area.
Due 15 April 2008
Resolved 20 April 2008
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 20 March 2008 Resolved
Repair smoke alarms for berthing area, and passenger compartment.
Due 15 April 2008
Resolved 20 April 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 January 2007 Resolved
Clean all battery terminals, noted to have heavy deposits of corrosion. 46CFR183
Action required: 705 - Other - as specified
Due 17 February 2007
Resolved 29 March 2007
Lifesaving › Lifefloat › Serviceable
Issued 17 January 2007 Resolved
(10 pax life float) Replace retroflective tape, grab lines and repair rips to outer cover. 46CFR180
Action required: 705 - Other - as specified
Due 17 February 2007
Resolved 29 March 2007
Communications › Public Address System › Loudspeaker
Issued 17 January 2007 Resolved
Repair PA system, noted heavy breakup during testing. 46CFR184
Action required: 705 - Other - as specified
Due 17 February 2007
Resolved 29 March 2007
Lifesaving › Lifefloat › Serviceable
Issued 17 January 2007 Resolved
Provide safe access to lifesaving equipment stowed on roof of bridge. 46CFR180
Action required: 705 - Other - as specified
Due 17 February 2007
Resolved 29 March 2007
Communications › Radio Communications › EPIRB
Issued 17 January 2007 Resolved
Replace broken EPIRB antennae and update expired registration. 46CFR185
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2007
Resolution: Rcvd fax showing proof of registration and purchase of new antennae.
Lifesaving › Hand Flares › Storage
Issued 7 March 2006 Resolved
Replace the Distress Signal container w/a brightly colored one marked "Distress Signals."
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2006
Resolved 23 March 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 March 2006 Resolved
Provide properly stocked First Aid Kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2006
Resolved 23 March 2006
Construction/Loadline › Penetrations › Valve Flange
Issued 7 March 2006 Resolved
Replace handle on the starboard raw water valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2006
Resolved 23 March 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 7 March 2006 Resolved
Demonstrate proper operation of SSB radio.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 March 2006
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 14 June 2005 Resolved
Two deck hands on board failed to have proof of consortium enrollment.
Condition: Improper/Lack of Maintenance
Due 22 June 2005
Resolved 20 June 2005
Resolution: Faxed proof of enrollment to MSFO Panama City.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 27 December 2004 Resolved
Replace all non-operating, water activated life jacket lights (50). 46 CFR 180.75.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 December 2004
Resolved 29 December 2004
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 27 December 2004 Resolved
Found 5 adult type I PFDs unserviceable (rotted thread in straps). Replace in kind. 46 CFR 180.71.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2005
Resolved 29 December 2004
Engineering › Fuel Oil Service System › Hose
Issued 27 December 2004 Resolved
Replace spring tension clamps on generator fuel system flexible hoses. 46 CFR 182.410(d)(3).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2005
Resolved 29 December 2004
Electrical › Electric Supply System (service) › Cable
Issued 27 December 2004 Resolved
Clean starting battery terminals and cables, port/starboard. 46 CFR 176.806.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2005
Resolved 29 December 2004
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 December 2004 Resolved
Label emergency fuel shutoff valves. 46 CFR 185.608.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2005
Resolved 29 December 2004
Fire Fighting › Fire Bucket › Quantity
Issued 27 December 2004 Resolved
Provide 1 additional suitable 2.5 gallon bucket with lanyard. 46 CFR 181.610.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2005
Resolved 29 December 2004
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 December 2004 Resolved
Install emergency lighting in accomodation space below main deck. 46 CFR 183.430.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2005
Resolved 29 December 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 27 December 2004 Resolved
Install smoke activated fire detection system in main passenger accommodation and overnight passenger accommodation. 46 CFR 177.500(c)(3).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 December 2004
Resolved 29 December 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 27 December 2004 Resolved
Mark alarm for smoke detector "SMOKE DETECTION ALARM". 46 CFR 185.612(e).
Action required: 705 - Other - as specified
Due 27 January 2005
Resolved 29 December 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 27 December 2004 Resolved
Provide evidence of annual service and testing of installed smoke detecting system upon completion of item #8. 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 December 2004
Resolved 29 December 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 27 December 2004 Resolved
Mount 1 B-II portable fire extinguisher in vicinity of machinery space exit (just outside). 46 CFR 181.500(a).
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2005
Resolved 29 December 2004
Construction/Loadline › Hull › Stiffener
Issued 6 October 2004 Resolved
Repair de-laminated tab in fore peak compartment, starboard side in way of deck to hull joint.
Action required: 705 - Other - as specified
Due 6 November 2004
Resolved 8 November 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 October 2004 Resolved
Properly mount/refasten deck rail as needed.
Action required: 705 - Other - as specified
Due 6 November 2004
Resolved 8 November 2004
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 6 October 2004 Resolved
Replace port and starboard propulsion shaft strut bearings.
Action required: 705 - Other - as specified
Due 6 November 2004
Resolved 8 November 2004
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 October 2004 Resolved
Clean port and starboard propulsion shafts and make available for inspection.
Action required: 705 - Other - as specified
Due 6 November 2004
Resolved 8 November 2004
Resolution: Both shaft drawn, examined and found satisfactory.
Construction/Loadline › Structures › Machinery Space Opening
Issued 6 October 2004 Resolved
Replace gasket on machinery space hatch.
Action required: 705 - Other - as specified
Due 6 November 2004
Resolved 8 November 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 October 2004 Resolved
Properly mount and secure non-vital (bait well) piping system.
Action required: 705 - Other - as specified
Due 6 November 2004
Resolved 8 November 2004
Construction/Loadline › Hull › Stringer
Issued 6 October 2004 Resolved
Repair de-laminated stringer tabs in steering compartment.
Action required: 705 - Other - as specified
Due 6 November 2004
Resolved 8 November 2004
Engineering › Bilge Water Management System › Pump
Issued 6 October 2004 Resolved
Properly mount and secure bilge pump in steering compartment.
Action required: 705 - Other - as specified
Due 6 November 2004
Resolved 8 November 2004
Unknown
Issued 5 October 2000 Resolved
Provide electrical, machinery and piping plans for review and approval in accordance 46 CFR 177.202.
Condition: Unknown
Due 5 December 2000
Resolved 28 August 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.