MAURY USCG vessel records Sign in
← All vessels

OCEAN INTREPID

OCEAN INTREPID is a 1983 unclassified. The Coast Guard has recorded 23 inspections since 2002, most recently in February 2025, along with 12 deficiencies and 3 operational controls.

Records from 2002 to 2025. Most recent: inspection, 6 February 2025.

Built
1983
Last inspected
6 February 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8641939 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
507177
Flag
VANUATU
—
Maury page id
psix-507177

Inspections, by type

…with no type recorded6
Years with a record 12 calendar years (2002–2025)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it6818 - Displacement, Ton
7217 - Convention (Subpart B), Gross Ton
7217 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

6 February 2025 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8075587
18 October 2023 PSC A
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7810431
14 July 2023 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7744403
21 May 2021 PSC A
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7202635
16 March 2021 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7159290
17 February 2012 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4245286
11 February 2011 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3943448
7 February 2011 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3937223
22 January 2011 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3938097
14 January 2010 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3663161
23 December 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3383657
10 September 2008 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3321610
12 December 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3114528
23 September 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2499498
20 September 2005 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2496845
17 March 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2312672
17 March 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2312790
3 August 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2160669
23 June 2004 MTSA/ISPS Verification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2109108
29 January 2004 Re-Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1996760
17 June 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1819889
20 June 2002 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1636862
17 May 2002 Uninspected Other
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1618058

Deficiency record · 12

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 October 2023 Resolved
Two MCT's going through A-60 boundaries are missing blocks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2023
Resolved 23 October 2023
Resolution: MCT's were replaced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 October 2023 Resolved
Port side drive room is missing insulation on A-60 bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2023
Resolved 23 October 2023
Resolution: Fire boundary has been corrected
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 21 May 2021 Resolved
EGEN had a fuel leak
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 May 2021
Resolved 26 May 2021
Resolution: Engineer was able to tighten fittings to resolve the fuel leak.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 21 May 2021 Resolved
OWS was inoperable during initial inspection
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 26 May 2021
Resolved 26 May 2021
Resolution: Chief Engineer was able to properly test the OWS prior to departing the vessel.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 January 2010 Resolved
Oil filtering equipment shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. The solenoid valve connected to the overboard discharge pipe does not close when oily mixture exceeds 15ppm, as indicated by the oil content meter, allowing the oily mixture to continually discharge overboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2010
Resolution: Class attended vessel: OWS faulty solenoid valve changed and new valve installed, tested and found satisfactory.
Engineering › Freshwater Generation System › Piping
Issued 14 January 2010 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items, the salt water intake pipe located in the space containing the ows, leading to the reverse osmosis equipment has a soft patch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2025
Resolution: Class attended vessel: Leaking water maker line cropped and renewed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 January 2010 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items. Liquid leaks through the connection securing the probe to the top of the ows.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2025
Resolution: Class attended vessel: Leaking probe on oily water seperator changed and new probe installed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 20 September 2005 Resolved
Automatic door closure in galley not installed properly, Replace/repair door closure to satisfaction of Coast Guard inspector in accordance with SOLAS Chapter 1 REG 11(c).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 October 2005
Resolved 23 September 2005
Resolution: Door closure replaced. Fire door fully operational.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 20 September 2005 Resolved
Master,2nd Eng and 3rd Eng do not have current flagstate licenses. Provide current flagstate licenses or copy of application to flagstate for licenses prior to departure from Port of Pascagoula to the satisfaction of the Coast Guard. SOLAS 74 IX / 3.1
Action required: 705 - Other - as specified
Resolved 23 September 2005
Resolution: Vessel provided applications for flagstate license endoresments.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 June 2002 Resolved
LIFEJACKETS NOT READILY AVAILABLE - STORED IN A LOCKER THAT HAD TO BE OPENED WITH A WRENCH.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2002
Resolved 26 June 2002
Resolution: LIFEJACKETS MOVED TO READILY ACCESSIBLE LOCATION.
Engineering › Sea-water System (primary cooling) › Valve
Issued 20 June 2002 Resolved
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2002
Resolved 26 June 2002
Fire Fighting › Miscellaneous Items
Issued 20 June 2002 Resolved
EXCESSIVE GEAR STORAGE FOUND IN CO2 ROOM. A LARGE LOCKER WITH SPARE FIREMAN'S OUTFITS WAS PLACED IN STORAGE THERE.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2002
Resolved 26 June 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.