OCEAN INTREPID is a 1983 unclassified. The Coast Guard has recorded 5 inspections since 2021, most recently in February 2025, along with 4 deficiencies.
Records from 2021 to 2025. Most recent: inspection, 6 February 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it6818 - Displacement, Ton 7217 - Convention (Subpart B), Gross Ton 7217 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
6 February 2025Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8075587
18 October 2023PSC A
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7810431
14 July 2023In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7744403
21 May 2021PSC A
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7202635
16 March 2021Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7159290
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 October 2023Resolved
Two MCT's going through A-60 boundaries are missing blocks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2023
Resolved 23 October 2023
Resolution: MCT's were replaced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 October 2023Resolved
Port side drive room is missing insulation on A-60 bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2023
Resolved 23 October 2023
Resolution: Fire boundary has been corrected
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 21 May 2021Resolved
EGEN had a fuel leak
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 May 2021
Resolved 26 May 2021
Resolution: Engineer was able to tighten fittings to resolve the fuel leak.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 26 May 2021
Resolved 26 May 2021
Resolution: Chief Engineer was able to properly test the OWS prior to departing the vessel.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.