Records from 1985 to 2026. Most recent: inspection, 14 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 51
14 April 2026
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8349475
10 September 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8230944
30 May 2024
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7922705
8 January 2024
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7837649
19 October 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7069311
25 July 2019
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6744592
24 May 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6692406
5 October 2018
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6548635
11 October 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6287077
30 May 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6159822
2 September 2016
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5982215
13 July 2015
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5183088
17 September 2010
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3853336
13 March 2009
Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3433026
21 November 2008
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3367011
20 November 2008
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3366564
2 April 2007
Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2899906
20 October 2006
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3366551
14 July 2005
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2418286
30 March 2005
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2311730
24 September 2003
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1911251
13 September 2002
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1675284
10 July 2002
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1644363
25 July 2001
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1470036
18 April 2001
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1437898
20 July 2000
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1470272
30 May 2000
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 819438
12 July 1999
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1411933
18 May 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 213296
18 May 1999
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1455707
21 September 1998
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 800819
20 June 1997
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 776717
22 April 1997
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1097129
24 June 1996
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1089030
29 June 1995
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 872268
24 June 1994
COI Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1353599
15 April 1994
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1359837
4 May 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1144286
27 April 1993
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1417508
27 May 1992
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 954863
19 April 1991
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 915613
18 March 1991
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1239500
16 May 1990
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1238143
15 May 1990
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1238142
21 December 1989
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1221124
19 May 1989
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1045317
16 May 1988
COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1041179
6 December 1985
Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 989190
30 August 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 987833
19 June 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1288972
13 June 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 980140
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 16 September 2025
Resolved
A vessel not required to have a power driven fire pump by §?181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel could not produce the buckets. Provide to the attending USCG MI within 14 days.
46CFR 181.610
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2025
Resolved 23 September 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 16 September 2025
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The Coast Guard will review all information provided and will determine whether— The master was unable to provide medical certificate. Provide to the attending USCG MI within 14 days.
46CFR 10.301
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2025
Resolved 23 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 September 2025
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. Vessel did not have the required clip and attach arrangement, provide to the attending USCG MI within 14 days.
46CFR 180.70.d.3.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2025
Resolved 23 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 September 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. The installed system fails to secure engine during activation. Provide proof of satisfactory operation to the attending USCG MI within 14 days.
46CFR 181.420
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2025
Resolved 13 October 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 September 2025
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. DANCING TURTLE had an anniversary date of 30MAY29. 90 day window expired on 30AUG25. Vessel to conduct a COI exam for renewal prior to carriage of passengers.
46CFR 176.100
46CFR 176.500.b.1.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 September 2025
Resolved 16 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 May 2024
Resolved
The vessel must be equipped with an adult size lifejacket for each person authorized and child size lifejackets for at least 10% of the maximum number of passengers. The vessel was missing 1 adult lifejacket and 2 child lifejackets. Vessel is restricted to 10 adults (9 passengers and 1 crew) and no children until lifejackets are onboard.
46CFR176.808
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 May 2024
Resolution: lifejackets were purchased, marked, and placed aboard the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 October 2020
No resolution recorded
No person may operate a vessel to which this part applies unless it has on board: A valid certificate of number or temporary certificate for that vessel issued by the issuing authority in the State in which the vessel is principally operated. Provide valid certificate with new owner information.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020 — due date passed with no resolution recorded
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 19 October 2020
No resolution recorded
Each officer employed on any vessel subject to this subchapter must have his or her merchant mariner credential (MMC) on board at all times when the vessel is operating. Master does not hold MMC. Provided MMC.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2020
No resolution recorded
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. No established program onboard. Provided.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2020
No resolution recorded
A vessel of not more than 26 feet in length must carry a minimum of one life buoy. Life buoy not fitted with approved waterlight and corrosion-resistant clip, And no retroreflective material.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 October 2020
No resolution recorded
Distress flares. Lakes, bays, and sounds, and rivers routes. Three hand red flare distress signals and Three hand orange smoke distress signals. Each flare carried to meet this section must be stowed in one of the following: A portable watertight container marked as required by §185.614 of this chapter, carried at the operating station. Only 4 red flares onboard. Provide additional flares and provide watertight container.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 October 2020
Resolved
At each subsequent inspection for certification, the owner must have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of portable fire extinguishers, and fixed gas fire extinguishing system. Fire fighting equipment has not been serviced in over a year. Service equipment and provided report.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020
Resolved 3 December 2020
Resolution: FF equipment serviced and report provided. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2020
No resolution recorded
Each vessel must be marked as required by part 67, subpart I, of this chapter. Vessel name and numbers have not been changed. Change vessel name and numbers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2020
No resolution recorded
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. No stowage location markings. Mark location.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2020
No resolution recorded
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. No placards onboard. Provide donning instruction placard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 October 2020
No resolution recorded
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. No up-to-date Chart onboard. Provide.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 October 2020
No resolution recorded
A submersible electric bilge pump may be used provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113. Provided documentation for current pump or replace with pump meeting UL 1113.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 October 2020
No resolution recorded
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. No visual indicator at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2020 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 July 2019
Resolved
Provide a means to close ventilation to engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2019
Resolved 29 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 July 2019
Resolved
Provide chartlet of area of operation onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2019
Resolved 29 August 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 July 2019
Resolved
Provide means for air intake for engine to take air outside the engine compartment or prove proper operation of the automatic shutdown of fireboy system upon actuation of the fixed fire extinguishing system and overide function.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2019
Resolved 29 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 5 October 2018
Resolved
Vessel is required 3 day and 3 night distress signals. Renew VDS.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2018
Resolved 11 October 2018
Resolution: Renewed VDS.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2018
Resolved
All cable and wiring must be properly terminated. Properly terminate or remove exposed electrical connection in shaft alley.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2018
Resolved 11 October 2018
Resolution: Properly terminated wire.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2018
Resolved
Electrical equipment must be installed and maintained to provide services necessary. Engine starter not properly working replace starter.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2018
Resolved 11 October 2018
Resolution: Renewed starter op test sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 September 2016
Resolved
Provid servicing report for fixed and portable fire extinguishing. (Fireboy//Not CO2)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2016
Resolution: Provided servicing report for fixed and portable fire extinguishing.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 2 September 2016
Resolved
Properly mount portable fire extinuisher.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 23 September 2016
Resolution: Properly mounted portable fire extinuisher.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 July 2015
Resolved
Vessel is to provide service report for fixed fire extinguishing system in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2015
Resolved 28 August 2015
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 July 2015
Resolved
Vessel is to clean up wire runs to include proper hanger supports.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 August 2015
Resolved 28 August 2015
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 May 2009
Resolved
Tighten hand rail.
Action required: 705 - Other - as specified
Resolved 14 August 2009
Documentation › Markings/Placards › Certificate of Number (state)
Issued 13 March 2009
Resolved
Replace state registration number on port/stbd bow.
Action required: 705 - Other - as specified
Resolved 9 October 2009
Resolution: Number replaced.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 13 March 2009
Resolved
Properly label life jacket stowage with number and type (adult/child).
Action required: 705 - Other - as specified
Resolved 9 October 2009
Resolution: Adult and child life jacket stowage labeled.
Engineering › Bilge Water Management System › Pump
Issued 13 March 2009
Resolved
Repair portable bilge pump so that hose does not leak during pumping.
Action required: 705 - Other - as specified
Resolved 9 October 2009
Resolution: Satisfatorily tested portable bilge pump.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 13 March 2009
Resolved
Create training and ships log, complete training at least quarterly.
Action required: 705 - Other - as specified
Resolved 9 October 2009
Resolution: Training log complete and up to date.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 March 2009
Resolved
Repair or remove electrical wires that are loose and disconnected.
Action required: 705 - Other - as specified
Resolved 9 October 2009
Resolution: Electrical panel rewired and re-organized.
Lifesaving › Hand Flares › Not on Board
Issued 13 March 2009
Resolved
Procure 3 orange smoke distress signals for distress signal kit or submit a letter requesting a route away from the dock for now more than 30 minutes.
Action required: 705 - Other - as specified
Resolved 9 October 2009
Resolution: Flares obtained.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 March 2009
Resolved
Repair or replace navigation sidelights so that each has an arc of visibility of 112.5 degrees from straight ahead to 22.5 degrees abaft of beam on each side.
Action required: 705 - Other - as specified
Resolved 9 October 2009
Resolution: Navigation ligths replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 March 2009
Resolved
Replace engine exhaust hose.
Action required: 705 - Other - as specified
Resolved 9 October 2009
Resolution: Exhaust piping replaced.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 March 2009
Resolved
Repair or replace Fireboy alarm panel and automatic engine shutdown.
Action required: 705 - Other - as specified
Resolved 9 October 2009
Resolution: Fireboy system tested satisfactorily.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 14 July 2005
Resolved
REPLACE 6 ADULT/2 CHILD LIFE JACKETS (IAW 180.71) AND PLACE NAME OF VSL (IAW 183.604(B)). FIT WITH RETROREFLECTIVE TAPE (PRIOR TO CARRYING MAX NUMBERS OF PAX).
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 15 July 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 14 July 2005
Resolved
RENEW FCC STATION LICENSE PRIOR TO 11 AUG 05.
Action required: 705 - Other - as specified
Due 11 August 2005
Resolved 28 July 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 July 2005
Resolved
COMPLETE VSL BOOKLET WITH COPIES OF COI, STABILITY LETTER, EMERGENCY BROADCAST PLACARD, EMERGENCY INSTRUCTIONS, DONNING PLACARD, AND PLACE ON BOARD VSL (IAW [name withheld] 01-05)
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 6 October 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 July 2005
Resolved
MUST COMPLETE MOB, FIRE, ABANDON SHIP DRILLS IN ACCORDANCE WITH 46 CFR 185.520. PROVIDE LOG BOOK DOCUMENTATION WITH ALL MEMBERS TRAINED.
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 6 October 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 July 2005
Resolved
REPLACE/REPAIR WATERLIGHT WITH FUNCTIONING WATERLIGHT (IAW 46 CFR 180.70). LIMITED TO DAYLIGHT OPS UNTIL REPAIRED OR REPLACED.
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 15 July 2005
Engineering › Steering Gear System › Rudder
Issued 14 July 2005
Resolved
AFFIX INSTRUCTIONS AND TOOLS TO AUX STEERING AREA (IAW [name withheld] LETTER 01-05).
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 15 July 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 July 2005
Resolved
REPLACE RING LIFEBUOY LIFE LINE (IAW 46 CFR 180.70(C))--MUST BE BUOYANT AND UV RESISTANT.
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 15 July 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 14 July 2005
Resolved
INSTALL PRE-ENGINEERED FIXED GAS FIRE EXTINGUISHING SYSTEM IAW 181.420 PRIOR TO CARRIAGE OF PASSENGERS.
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 6 October 2005
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 24 September 2003
Resolved
Provide manual pull for manually actuating fixed fire extinguisher from outside the space. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Due 10 October 2003
Resolved 14 October 2003
Resolution: Issued new deficiency.
Lifesaving › Lifebuoys
Issued 24 September 2003
Resolved
Connect working waterlight to ringbuoy with 3-foot lanyard & corrosion-resistant clip, also mount water in area of ringbuoy.
Condition: Improper Installation
Due 10 October 2003
Resolved 14 October 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 24 September 2003
Resolved
Replace expired items in first aid kit. (aspirin, seasickness pills, etc.)
Due 10 October 2003
Resolved 14 October 2003
Documentation › Certificates/Documents
Issued 24 September 2003
Resolved
Provide proof of all launch operators being enrolled in drug & alcohol testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2003
Documentation › Certificates/Documents
Issued 24 September 2003
Resolved
Provide proof of fixed fire fighting system being tested/serviced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2003
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 24 September 2003
Resolved
Provide and install fixed fire fighting system. (Prior to next operating season.)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 30 March 2005
Resolution: verified that this vessel is incompliance
Fire Fighting › Miscellaneous Items
Issued 13 September 2002
Resolved
Provide three 2.5 gallon firebuckets with laniards attached.
Due 30 September 2002
Resolved 30 September 2002
Lifesaving › Lifebuoys
Issued 13 September 2002
Resolved
Provide and stow light for ring buoy LEGACY COMPONENT DESC: Self-igniting Lights
Due 30 September 2002
Resolved 30 September 2002
Lifesaving › Lifejacket/PFD (General)
Issued 13 September 2002
Resolved
Stencil vessel name on 2 child and 2 adult lifejackets.
Due 30 September 2002
Resolved 30 September 2002
Engineering
Issued 13 September 2002
Resolved
Mount and secure batteries
Due 30 September 2002
Resolved 30 September 2002
Lifesaving
Issued 13 September 2002
Resolved
Provide a portable light.
Due 30 September 2002
Resolved 30 September 2002
Fire Fighting
Issued 25 July 2001
Resolved
INSTALL FIXED FIRE EXTINGUSHING SYSTEM IN ACCORDANCE WITH 46CFR181.420.
Condition: Unknown
Due 1 April 2002
Resolved 10 July 2002
Unknown
Issued 18 April 2001
Resolved
REPLACE BILGE HOSE (GARDEN HOSE) WITH AN APPROVED MARINE GRADE HOSE.
Condition: Unknown
Due 20 July 2001
Resolved 30 July 2001
Fire Fighting
Issued 24 June 1994
Resolved
RECHARGE/SERVICE THE B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Lifesaving
Issued 24 June 1994
Resolved
REPLACE LIFERING DUE TO PERIMETER LINE BEING BRITTLE. STENCIL NAME OF VESSEL ON REPLACEMENT RING.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Construction/Loadline
Issued 24 June 1994
Resolved
RENEW BOTH PORT AND STBD AFT BILGE VENT DUCTS.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Construction/Loadline
Issued 24 June 1994
Resolved
REPAIR/REPLACE KINKED BILGE HOSE AT OVERBOARD CONNECTION.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Engineering
Issued 24 June 1994
Resolved
CORRECT SOURCE OF FUEL LEAK, VICINITY OF THE FUEL FILTER.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Unknown
Issued 27 April 1993
Resolved
PROVIDE PROOF OF ENROLLMENT IN PRE-EMPLOYMENT AND RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Fire Fighting
Issued 27 April 1993
Resolved
SERVICE OR REPLACE WITH NEW ONE DISCHARGED B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 4 May 1993
Resolved 12 May 1993
Lifesaving
Issued 27 April 1993
Resolved
REPLACE ONE (1) ADULT PFD.
Condition: Unknown
Due 4 May 1993
Resolved 12 May 1993
Navigation
Issued 13 June 1985
Resolved
REPAIR HORN AND MAKE AVAILABLE FOR TEST.
Condition: Unknown
Due 13 June 1985
Resolved 13 June 1985