9 July 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8434963
30 April 2026
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8358755
13 November 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090940
14 May 2025
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8088642
20 June 2024
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7942728
9 May 2024
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7874328
16 November 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7623066
9 June 2023
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7644967
13 June 2022
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411297
5 November 2021
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7154905
9 August 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161606
14 May 2020
DAPI Audit · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6908366
5 November 2019
Drydock Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6849561
20 June 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637800
14 June 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375222
30 November 2017
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6307541
16 May 2017
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105415
19 May 2016
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5830682
14 April 2016
Internal Structural Exam · Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5829336
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Remove old/unused wires identified on the port side of the engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2026
Resolved 15 July 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2026
Resolved
A space containing diesel machinery must be fitted with at least two ducts to furnish natural supply and exhaust ventilation. Caulk or renew the port side engine room ventilation ducting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2026
Resolved 15 July 2026
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 November 2025
Resolved
A shutoff valve must be located where the cooler piping penetrates the shell, as near the shell as practicable, except where the penetration is forward of the collision bulkhead. Shutoff valve in engine space not able to open/close. Repair or replace valve.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 April 2026
Resolved 30 April 2026
Resolution: Inspected shutoff valve. All sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 June 2022
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Audible alarm is difficult to hear.
Action required: 10 - Deficiency Rectified
Due 13 June 2022
Resolved 13 June 2022
Resolution: New high water alarm installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 August 2021
Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Rails shall consist of evenly spaced courses and the spacing between courses shall not be greater than 12 inches. No lifelines at embarkation point.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2021
Resolution: Vessel has installed lifelines at the embarkation point.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 May 2017
Resolved
Forward white light is hanging by its wires, properly install.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 19 May 2017
Engineering › Fuel Oil Service System › Valve
Issued 16 May 2017
Resolved
Relabel emergency fuel shutoff, label is torn and unreadable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 19 May 2017
Engineering › Bilge Water Management System › Pump
Issued 16 May 2017
Resolved
Bilge pump is not functioning, repair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2017
Resolved 19 May 2017
Construction/Loadline › Hull › Bottom Plating
Issued 19 May 2016
Resolved
Repair fiberglass delamination fwd. of engine on bottom of bilge.
Condition: Design Flaw
Due 19 June 2016
Resolved 16 June 2016
Resolution: Repairs adequately made to fiberglass
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 May 2016
Resolved
Repair or replace stern light to provide proper illumination.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2016
Resolution: Repaired stern light.
Engineering › Bilge Water Management System › Pump
Issued 19 May 2016
Resolved
repair/ replace bilge pump in engine room and prove proper operation.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2016
Resolution: Repaired bilge pump.
Engineering › Steering Gear System › Pin
Issued 19 May 2016
Resolved
Provide proper tools for emergency steering.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2016
Resolution: Provided two box end wrenches
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 April 2016
Resolved
Top of caprail port side was cracked and presented a danger to passengers and crew.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 25 April 2016
Resolution: Cap rail was filled, repaired, and sanded, then recoated. Repair satisfactory.