MAURY USCG vessel records Sign in
← All vessels

ALERT

ALERT is a 1979 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1985, most recently in July 2026, along with 32 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 9 July 2026.

Built
1979
Last inspected
9 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-50719

Inspections, by type

…with no type recorded5
Years with a record 39 calendar years (1985–2026)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it2 - Simplified, Gross Ton
2 - Simplified, Net Ton
0 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 66

9 July 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8434963
30 April 2026 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8358755
13 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090940
14 May 2025 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8088642
20 June 2024 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7942728
9 May 2024 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7874328
16 November 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7623066
9 June 2023 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7644967
13 June 2022 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411297
5 November 2021 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7154905
9 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161606
14 May 2020 DAPI Audit · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6908366
5 November 2019 Drydock Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6849561
20 June 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637800
14 June 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375222
30 November 2017 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6307541
16 May 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105415
19 May 2016 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5830682
14 April 2016 Internal Structural Exam · Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5829336
21 March 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4820354
13 May 2012 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4246466
17 February 2012 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4246469
6 December 2011 Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4202626
1 February 2011 Re-Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3937197
23 February 2010 DAPI Audit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3684911
29 April 2009 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3416166
21 May 2008 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3188789
17 April 2008 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3166259
25 May 2006 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2629468
24 March 2006 Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2609073
18 May 2005 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2345068
5 April 2004 Re-Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2035318
20 May 2003 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1798158
30 April 2002 Re-Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1606840
23 May 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1065846
23 May 2000 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1420336
26 April 2000 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1048806
22 June 1999 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1397393
15 May 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1126467
2 April 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1122406
9 October 1997 Excursion Permit
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1108963
13 June 1997 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 774918
22 May 1996 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1099103
9 June 1995 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 883868
4 April 1995 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 881339
24 June 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 867607
30 November 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1419187
13 May 1993 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1370659
13 May 1992 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 962428
24 April 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1262522
11 June 1991 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1324597
27 March 1991 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 907198
25 May 1990 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 920148
10 July 1989 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1035938
20 June 1989 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1347324
2 June 1989 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1351460
12 May 1989 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 893622
12 May 1989 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1347162
2 November 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 889281
22 June 1988 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1347326
22 May 1988 Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1203915
22 May 1987 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1026419
21 May 1986 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 992206
29 October 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1301055
16 May 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1289468
28 March 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1288193

Deficiency record · 32

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Remove old/unused wires identified on the port side of the engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2026
Resolved 15 July 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2026 Resolved
A space containing diesel machinery must be fitted with at least two ducts to furnish natural supply and exhaust ventilation. Caulk or renew the port side engine room ventilation ducting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2026
Resolved 15 July 2026
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 November 2025 Resolved
A shutoff valve must be located where the cooler piping penetrates the shell, as near the shell as practicable, except where the penetration is forward of the collision bulkhead. Shutoff valve in engine space not able to open/close. Repair or replace valve.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 April 2026
Resolved 30 April 2026
Resolution: Inspected shutoff valve. All sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 June 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Audible alarm is difficult to hear.
Action required: 10 - Deficiency Rectified
Due 13 June 2022
Resolved 13 June 2022
Resolution: New high water alarm installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 August 2021 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Rails shall consist of evenly spaced courses and the spacing between courses shall not be greater than 12 inches. No lifelines at embarkation point.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2021
Resolution: Vessel has installed lifelines at the embarkation point.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 May 2017 Resolved
Forward white light is hanging by its wires, properly install.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 19 May 2017
Engineering › Fuel Oil Service System › Valve
Issued 16 May 2017 Resolved
Relabel emergency fuel shutoff, label is torn and unreadable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 19 May 2017
Engineering › Bilge Water Management System › Pump
Issued 16 May 2017 Resolved
Bilge pump is not functioning, repair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2017
Resolved 19 May 2017
Construction/Loadline › Hull › Bottom Plating
Issued 19 May 2016 Resolved
Repair fiberglass delamination fwd. of engine on bottom of bilge.
Condition: Design Flaw
Due 19 June 2016
Resolved 16 June 2016
Resolution: Repairs adequately made to fiberglass
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 May 2016 Resolved
Repair or replace stern light to provide proper illumination.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2016
Resolution: Repaired stern light.
Engineering › Bilge Water Management System › Pump
Issued 19 May 2016 Resolved
repair/ replace bilge pump in engine room and prove proper operation.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2016
Resolution: Repaired bilge pump.
Engineering › Steering Gear System › Pin
Issued 19 May 2016 Resolved
Provide proper tools for emergency steering.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2016
Resolution: Provided two box end wrenches
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 April 2016 Resolved
Top of caprail port side was cracked and presented a danger to passengers and crew.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 25 April 2016
Resolution: Cap rail was filled, repaired, and sanded, then recoated. Repair satisfactory.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 14 May 2012 Resolved
Replace Fireboy cylinder which was manufactured in 1999 is over 12 years old.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2012
Resolved 21 May 2012
Lifesaving › Lifebuoys › Serviceable
Issued 10 May 2011 Resolved
Life ring is unserviceable. Renew prior to carrying passengers. To include renewing life line.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2011
Resolved 28 June 2011
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 February 2010 Resolved
Company does not have a written program or policy IAW 46 CFR 16.401 (a), create a written company policy and ensure display and distribution.
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 22 March 2010
Resolution: Policy e-mailed and attached in MISLE.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 23 February 2010 Resolved
Company does not complete background checks on employees IAW 49 CFR 40.25, create a form for employees to fill out background information and request information on all new employees and all employees that have been working for less than 2 years.
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 25 March 2010
Resolution: Rcvd background check from DER, attached to MISLE.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 February 2010 Resolved
Company does not have a Designated Employer Representative (DER) designated in writing IAW 49 CFR 40.3 & 40.35, designate DER in writing.
Action required: 705 - Other - as specified
Due 26 March 2010
Resolved 22 March 2010
Resolution: Policy specifies DER as [name withheld].
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 April 2009 Resolved
Remove temporary extension cords used for lighting fixtures or replace with permanent installed approved boat cable.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 19 May 2009
Resolution: A power distribution panel was installed and the lighting fixtures were hard wired to the panel.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 21 May 2008 Resolved
Repair or replace fixed fire bottle due to corrosion.
Action required: 705 - Other - as specified
Due 28 May 2008
Resolved 27 May 2008
Resolution: Removed corrosion and re-painted fire bottle.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 21 May 2008 Resolved
Repair or replace shutoff valve in way of MDE suction.
Action required: 705 - Other - as specified
Due 28 May 2008
Resolved 27 May 2008
Resolution: Cleaned shutoff valve and made operable.
Engineering › Fuel Oil Service System › Piping
Issued 21 May 2008 Resolved
Provide hose clamp for return line to fuel filter.
Action required: 705 - Other - as specified
Due 28 May 2008
Resolved 27 May 2008
Resolution: Provided clamp for return line.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 April 2004 Resolved
Address the loose rails
Due 11 June 2004
Resolved 11 June 2004
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 5 April 2004 Resolved
Secure the anchor shackles so that they wont back off
Due 11 June 2004
Resolved 11 June 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 20 May 2003 Resolved
INSTALL PFD DONNING PLACARD FOR PASSENGERS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2003
Resolved 5 June 2003
Resolution: DONNING PLACARD POSTED.
Lifesaving › Lifejacket/PFD (Type V)
Issued 20 May 2003 Resolved
RELABEL VESSELS NAME ON RING BUOY, VESSEL NAME IS FADED AND UNREADABLE. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2003
Resolved 5 June 2003
Resolution: VESSEL NAME STENCILED ON RING BUOY.
Engineering › Bilge Water Management System
Issued 20 May 2003 Resolved
MAKE INSTALLED BILGE PUMP OPERATIONAL. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 May 2003
Resolved 5 June 2003
Resolution: BILGE PUMP OPERATIONAL, FLOAT SWITCH REPLACED.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 20 May 2003 Resolved
INSTALL MISSING B-1 FIRE EXTINGUSHER LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2003
Resolved 5 June 2003
Resolution: B-1 INSTALLED AND PROPERLY MOUNTED
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 May 2002 Resolved
01 jacket found defective
Due 12 June 2002
Resolved 12 June 2002
Lifesaving › Buoyant Apparatus
Issued 22 May 2002 Resolved
Provide reflective tape on the life ring
Due 12 June 2002
Resolved 12 June 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 30 April 2002 Resolved
Provide proof of testing and servicing for the fixed fire fighting system
Action required: 705 - Other - as specified
Resolved 7 August 2002
Resolution: Owner to complete monthly testing of FFF system.
Unknown
Issued 22 June 1999 Resolved
PROVIDE ADEQUATE VENTILATION ARRANGEMENT IWO E/R.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.