PGC STRIDENT FORCE

PGC STRIDENT FORCE is a 1999 tank ship. The Coast Guard has recorded 8 inspections since 2016, most recently in March 2019, along with 9 deficiencies — 1 with no resolution recorded — and 4 operational controls.

Records from 2016 to 2019. Most recent: operational control imposed, 25 March 2019.

Built
1999
Last inspected
25 March 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 March 2019
…with no type recorded2
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9205574
507236
Flag
BAHAMAS, THE
Maury page id
psix-507236

Documentation record

Tonnage as PSIX records it1968 - Convention (Subpart B), Net Ton
8485 - Dead Weight, Metric Ton
12716 - Displacement, Metric Ton
6560 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

25 March 2019 COC-GAS Renew · In-Service Inspection · Administrative Inspection · Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6647458
1 December 2017 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6308890
22 November 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6312793
9 March 2017 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6104502
15 November 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6041698
14 November 2016 Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6038934
15 September 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6001718
11 February 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5813570

Deficiency record · 9

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 March 2019 Resolved
06199 - On ships carrying flammable or toxic products or both, a water-spray system for cooling, fire prevention and crew protection should be installed to cover exposed cargo tank domes and any exposed parts of cargo tanks, cargo liquid and vapour discharge and loading manifolds, and boundaries of superstructures and cargo compressor rooms (facing the cargo area) [11.3.1]. The system should be capable of covering all areas mentioned in 11.3.1 with a uniformly distributed water-spray of at least 10 l/m2 per minute for horizontal projected surfaces and 4 l/m2 per minute for vertical surfaces [11.3.2]. Per Certificate of Fitness, vessel is authorized carriage of multiple flammable and toxic products and has recently carried flammable products. Furthermore, vessel intended to load propylene upon completion of USCG port state control exam. During operational test, PSCOs noted that installed deck water spray system provided inadequate coverage to the following required locations: #1 and #2 cargo tank domes/exposed cargo tank tops, port manifold, starboard manifold, cargo compressor room boundary, and boundary at front of superstructure. 74 SOLAS (14) VII/13.1 REF IGC 93/11.3 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 30 March 2019
Resolution: Received class report and witnessed satisfactory operation after crew aligned fire/G.S. pump to work with deck spray. See activity notes and special note regarding use of both pumps.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 March 2019 No resolution recorded
06199-Electrical installations should be such as to minimize the risk of fire and explosion from flammable products [IGC 10.1.2]. Electrical equipment, cables, and wiring should not be installed in hazardous locations unless it conforms with the standards not inferior to those acceptable to the Organization [IGC 10.1.4, refers to IEC 60092:502]. Cables shall enter an explosion protected enclosure only by means of a gland or equivalent device cable of maintaining the integrity of the enclosure [IEC 7.5.1]. Cable entrance to explosion-proof junction box for #2 cargo pump motor casing found to be missing the appropriate gland or equivalent means, compromising the integrity of the enclosure. Cable entrances to differential pressure switches, level switches for #1 and #2 intercoolers, and level switch for #2 knockout drum within the cargo compressor room found loose and exposed. Both the #2 cargo pump motor casing and the switches in the cargo compressor room are located in hazardous locations (gas-dangerous zones, as defined by IGC 93/1.3.17). 74 SOLAS (14) VII/13.1 REF IGC 93/10.1 30abc
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 March 2019 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Liquefied Gases in Bulk (ICoF/IGC Code)
Issued 25 March 2019 Resolved
01112-An International Certificate of Fitness (COF) for the Carriage of Liquefied Gases in Bulk, should be drawn up in the form corresponding to the model given in the appendix. The appendix for the model form of the International COF for the Carriage of Liquefied Gases in Bulk requires all cargo tanks and their associated numbers to be listed along with their authorized products and conditions of carriage. IGC 93/1.3.11 defines a cargo tank as a liquid tight shell designed to be the primary container of the cargo and includes all such containers whether or not associated with insulation or secondary barriers or both. PSCOs noted the vessel is equipped with port and starboard deck tanks capable of carrying 22.5 m3 of liquefied gases in bulk. Neither deck tank is listed on the COF. 74 SOLAS (14) VII/13.1 REF IGC 93/1.5.4.2 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2019
Resolution: Received class report that tanks are isolated and not to be used. Annotated COC to reflect that tanks are not to be used in US waters.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 March 2019 Resolved
06199-Each cargo tank with a volume exceeding 20 m3 should be fitted with at least two pressure relief valves [8.2.1]. Pressure relief valves should be set and sealed by a competent authority acceptable to the Administration [8.2.5]. Deck tanks are 22.5 m3 in size. Pressure relief valve on port deck tank found to not be properly sealed, allowing for adjustment of the valve's set pressure without breaking of the seal. Furthermore, the relief valves on both deck tanks are sealed in various conditions and would not prevent tampering. 74 SOLAS (14) VII/13.1 REF IGC 93/8.2 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2019
Resolution: Received class report that tanks are isolated and not to be used. Annotated COC to reflect that tanks are not to be used in US waters.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 March 2019 Resolved
06109-An International Certificate of Fitness for the Carriage of Liquefied Gases in Bulk should be drawn up in the form corresponding to the model given in the appendix. Vessel's Certificate of Fitness, No. 18BC0394-GAS, has 6.1, 6.2, and 6.3 (different options pertaining to how the ship shall be loaded) lined out. The only verbiage not lined out is "where it is required to load in the ship other than in accordance with the above instructions, then the necessary calculations to justify the proposed loading condition shall be communicated to the certifying Administration who may authorize in writing the adoption of the proposed loading condition." There is no objective evidence of communication with the certifying Administration, and all three regular options for how the ship shall be loaded are lined out. 74 SOLAS (14) VII/13.1 REF IGC 93/1.5.4 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 March 2019
Resolution: Received class report. A new COF will be issued after dry dock to reflect correct loading instrument arrangement.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 25 March 2019 Resolved
15109- The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company [10.1]. In meeting these requirements, the Company should ensure that any non-conformity is reported [10.2.2] and appropriate corrective action is taken [10.2.3]. As detailed in deficiency #1, objective evidence exists that the deck water spray system has not been maintained in conformity with the provisions of the relevant rules (IGC Code 11.3). PSCOs noted records of periodical / pre-cargo testing of deck water spray system as in acceptable condition. This is directly contradicted by the condition of the system observed by the attending PSCOs. As detailed in deficiency #2, objective evidence exists that the electrical systems, specifically within the cargo area, has not been maintained in conformity with the provisions of the relevant rules (IGC Code 10.1.2). *Based on the above, an internal ISM audit, focusing on cargo specific requirements, is required. 74 SOLAS (14) IX/3.1 REF ISM 10 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2019
Resolution: Recieved Internal ISM audit results from vessel's company.
Engineering › Steering Gear System › Rudder Stock
Issued 1 December 2017 Resolved
1499- Steerling Gear- Steerling gear control shall be provided for the main steering gear, both on the navigational bridge and in the steering gear compartment; where the main steering gear is arranged in accordance with paragraph 6, by two independent control systems both operable from the navigational bridge. Vessel experienced a steering failure while conducting test of the steering gear. Vessel is to provide class and tec report prior to vessel movement. SOLAS (14) II-1/29.7, 60a
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2017
Resolution: Reviewed and accepted class report from NKK. The report stated the vessel experienced asteering failure while conducting fest of the # 2 steering gear. Some contamination was found and removed. Steerling gear was then retested and found satisfactory.
Lifesaving › Lifeboat › Handholds/Handrails
Issued 14 November 2016 Resolved
0610 - Starboard side lifeboat entry door handrail was wasted. 74SOLAS(1997cons.)IIII/44.2.6 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2016
Resolution: PSC HOU/GAL received a class report from NKK satisfying the requirement.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 14 November 2016 Resolved
0750 - 3 self closing fire doors in galley were found to be non self closing. 74SOLAS(14)II-2/14-2.1.1.1 10C
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 November 2016
Resolution: Crew members installed self closing hinges prior to end of the exam, deficiency rectified to satisfaction of CG inspector.