MAURY USCG vessel records Sign in
← All vessels

AOLANI.CC

AOLANI.CC is a 1998 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 1998, most recently in January 2026, along with 74 deficiencies, 1 operational control and 2 casualty investigations between 2005 and 2019.

Records from 1998 to 2026. Most recent: inspection, 26 January 2026.

Built
1998
Last inspected
26 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC3547
507421
Flag
UNITED STATES
367410000
Maury page id
psix-507421

Inspections, by type

…with no type recorded3
Years with a record 20 calendar years (1998–2026)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)58.0 ft × 30.0 ft × 9.0 ft
Registered tonnagegross 54 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUNCHASER CORPORATION · HOQUIAM, WA, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Simplified, Net Ton
54 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC3547MMSI 367410000 · active · compulsorily equipped · granted 21 December 2024, expires 11 January 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 33

26 January 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8302007
16 December 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8284607
6 February 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8076027
29 February 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7872400
3 January 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7844676
9 January 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7618875
4 March 2022 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7404404
15 December 2021 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7368236
25 January 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7130262
6 January 2020 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6883838
3 December 2019 Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6865630
11 September 2019 Deficiency Check · Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6809914
11 September 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6813132
7 January 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6606446
5 December 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6318442
30 October 2017 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6297628
9 January 2017 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6068038
25 January 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5803111
8 December 2015 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5777396
28 December 2010 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3915492
8 January 2010 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3650004
9 December 2008 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3362247
9 December 2008 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3384087
29 October 2007 Hull Examination · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3085608
15 February 2007 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3086831
13 December 2005 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2548416
11 January 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2279816
6 January 2005 Deficiency Check · Annual Inspection · Damage Survey · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2256985
18 March 2004 Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2026995
5 November 2003 Deficiency Check · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1942805
11 September 2002 Hull Examination · Deadweight Survey · Initial Certification · Plan Review "T" Boat
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1676918
8 May 2000 Type not recorded
No type recorded · Station Noyo River · USCG Southwest District (CGD-SW) · Activity 1517465
26 May 1998 Construction Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1378511

Deficiency record · 74

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 January 2026 Resolved
Bring areas identified by the MI back to bare metal for inspection by MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2026
Resolution: MI inspected mast.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 26 January 2026 Resolved
Vessel Captain was operating required VHF-FM radio equipment without holding a valid FCC radio operator permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2026
Resolution: All sat
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 26 January 2026 Resolved
Credentialed mariner serving on board without evidence of a valid medical certificate as required by 46 CFR 10.301. Provide proof of medical certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2026
Resolution: All sat
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 February 2024 Resolved
Observed all three life boat hanks are bounded and individually taped together. Vessel is to remove tape and utilize an easier method that allows a user to quickly deploy hanks.
Action required: 705 - Other - as specified
Resolved 1 March 2024
Resolution: Received pic of replaced twine on hanks
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 March 2022 Resolved
Alcohol testing of each individual must be conducted within 2 hours of when an incident occurs. Vessel found to have expired alcohol test strips. Replace alcohol tests with new.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2022
Resolved 5 March 2022
Resolution: Provided proof of test strips.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 March 2022 Resolved
Port rudder post missing roller, and cotter pin on rod securing post in place. Install IAW manufacturer's instruction. Corrected on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 March 2022
Resolution: Corrected on the spot
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 4 March 2022 Resolved
Access hatch for port aft space found to be loose with missing hardware. Replace hardware and make secure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2022
Resolved 21 March 2022
Resolution: POC replaced hardware.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 March 2022 Resolved
Absorbent rags soaked in hydraulic fluid found in port engine room bilge space. Remove rags.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2022
Resolved 21 March 2022
Resolution: POC removed soaked rags from bilge.
01 - Certificates & Documentation › 011 - Ships Certificates › Liability of carriage of passengers certificate
Issued 4 March 2022 Resolved
Vessel does not keep the passenger count with a shore entity prior to each voyage. Provide a system for the vessel’s master to keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore with a representative of the owner, and shall be available to the Coast Guard upon request.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2022
Resolved 21 March 2022
Resolution: POC provided plans to pass passenger information to vessel representative on shore before each departure.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 March 2022 Resolved
Vessel’s stability letter was not readily available for the vessel’s crew. Provide a copy of the vessel’s stability letter for the vessel’s master at all times while operating the vessel. Corrected on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 March 2022
Resolution: corrected on the spot
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 March 2022 Resolved
Vessel does not have a written garbage management plan posted. Provide a written garbage management plan for the vessel and post on the vessel where it can readily be seen by crew and passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2022
Resolved 21 March 2022
Resolution: POC Provided new garbage management plan.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 March 2022 Resolved
VHF DSC equipped radio found to be installed without MMSI number programmed. Program VHF DSC radio with vessel's MMSI number.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2022
Resolved 21 March 2022
Resolution: POC programmed MMSI number to DSC radio.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 December 2021 Resolved
Roller furler requires internal inspection by rigging expert.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2022
Resolved 11 January 2022
Resolution: Roller Furler serviced by Casey at Offshore Rigging.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 January 2021 Resolved
"On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level... A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating." All visual indicators for the high water alarms and automatic bilge pumps in the starboard hull are inoperable. Enact repairs on the visual indicators for the starboard hull.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2021
Resolved 10 February 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 January 2020 Resolved
Provide proof of valid FCC Radio Safety Telephony Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2020
Resolved 8 January 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 6 January 2020 Resolved
Provide proof that all licensed crewmembers have a Marine Radio Operator Permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2020
Resolved 13 January 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 January 2020 Resolved
Provide DOT approved alcohol test strips.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2020
Resolution: Vessel acquired valid ALCO Screen test strips.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2019 Resolved
Replace standing rigging as needed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2019
Resolution: Received rigging replacement report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2019 Resolved
Provide rigging report and full component inventory.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2019
Resolution: Received Rigging Itemization report.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 11 September 2019 Resolved
Make permanent repairs to deck and hull spreader bar and conduct sea trials prior to carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2019
Engineering › Fuel Oil Service System › Valve
Issued 30 October 2017 Resolved
Provide proper mechanism to be able to be fuel shut-off valve manual operable from outside the space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 5 December 2017
Resolution: The fuel shut-off valve is now operable outside the space
Engineering › Fuel Oil Service System › Hose
Issued 30 October 2017 Resolved
Make flexible hose for vital sytems not to exceed 30 inches and hose clamps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 5 December 2017
Resolution: Hoses installed proper fittings to exceed 30"
Lifesaving › Buoyant Apparatus › Painter
Issued 9 January 2017 Resolved
Provide proper arragement for the lifefloat sea painter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 13 January 2017
Resolution: Provided proper arragement for the lifefloat sea painter
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 9 January 2017 Resolved
Provide proper labling for PFDs
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 13 January 2017
Fire Fighting › Means of Escape › Escape Route Signs
Issued 9 January 2017 Resolved
Provide labels for escape hatches
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 13 January 2017
Resolution: Provided labels for escape hatches
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 January 2017 Resolved
Provide name of vessel on Lifebouy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 13 January 2017
Resolution: Provided name of vessel on lifebouy
Engineering › Bilge Water Management System › Valve
Issued 25 January 2016 Resolved
Provide positive shutoff valves at each hull penetration of submersible bilge pump discharge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 23 February 2016
Resolution: Attended vessel and verified install of Positive shut off valves for every submersible bilge pump.
Engineering › Bilge Water Management System › Pump
Issued 14 December 2009 Resolved
Provide portable hand pump.
Due 8 February 2010
Resolved 13 January 2010
Resolution: Provided hand pump.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 December 2009 Resolved
Provide updated chart and nav pubs
Due 8 February 2010
Resolved 13 January 2010
Resolution: Provided new charts and pubs.
Electrical › Electric Supply System (service) › Cable
Issued 14 December 2009 Resolved
Provide covers for battery terminal blocks located in battery room.
Condition: Improper/Lack of Maintenance
Due 8 February 2010
Resolved 13 January 2010
Resolution: Provided new plasticcovers for terminal blocks.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 December 2009 Resolved
Provide new alcohol swabs
Due 8 February 2010
Resolved 13 January 2010
Resolution: Provided 2 new alcohol test kits.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 14 December 2009 Resolved
Provide B/C II fire extinguisher in way of each engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2010
Resolved 13 January 2010
Resolution: Provided 2 new BCII extinguishers in way of eng room.
Documentation › Markings/Placards › Lifejacket Placard
Issued 14 December 2009 Resolved
Provide donning placard for safeguard type 1 lifejackets.
Due 8 February 2010
Resolved 13 January 2010
Resolution: Provided donning placard.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 December 2008 Resolved
Ring Buoy missing retro-reflective tap. Install retro-reflective tape iaw 46 CFR 185.604
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2008
Resolution: Installed Retro-Reflective tape on Ring buoy
Lifesaving › Liferaft Equipment › Batteries (electric torch spares)
Issued 9 December 2008 Resolved
Replace batteries with non-expired batteries iaw 46 CFR 180.75
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2008
Resolution: Replaced (3) float light batteries.
Communications › Radio Communications › EPIRB
Issued 9 December 2008 Resolved
Expired EPIRB Battery (9/08 exp). Replace EPIRB Battery IAW 46 CFR 180.64
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2008
Resolution: EPIRB Battery replaced.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 9 December 2008 Resolved
Provide current Master's License iaw 46 CFR 185.402.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2008
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2008 Resolved
Company policy missing as required by 46 CFR 16.401.
Due 9 January 2009
Resolved 10 December 2008
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2008 Resolved
Company currently does not receive result/exemptions for pre-employment testing prior to an individual working in a safety sensitive position, as required by 46 CFR 16.210.
Due 9 January 2009
Resolved 9 January 2009
Resolution: Two missing Pre-Employments were faxed in by the company.
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2008 Resolved
Arrangements not made for post-casualty testing as required by 46 CFR 16.240.
Due 9 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2008 Resolved
Alcohol testing devices not onboard as required by 46 CFR part 4.
Due 9 January 2009
Resolved 10 December 2008
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2008 Resolved
Arrangements not made for reasonable cause testing as required by 46 CFR 16.240.
Due 9 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2008 Resolved
Employee assistance program statement not posted as required by 46 CFR 16.401.
Due 9 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2008 Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 9 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2008 Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company’s drug and alcohol policy in accordance with 46 CFR 16.401.
Due 9 January 2009
Resolved 9 January 2009
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2008 Resolved
Employee assistance program policy not in place as required by 46 CFR 16.401.
Due 9 January 2009
Resolved 9 January 2009
Lifesaving › Lifefloat › Quantity
Issued 29 October 2007 Resolved
Provide lifefloats for 100% of persons on-board. Vessel had buoyant apparatus vice lifefloats. Vessel restricted to LBS route nmt 1 mile from shore until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 October 2007
Resolved 14 November 2007
Resolution: Vessel operator installed authorized LF retrofit kit from JimBuoy (manufacturer) and paddles.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 29 October 2007 Resolved
Repair/replace kinked fuel line to generator fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 6 November 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 October 2007 Resolved
Provide proper pressure-type connectors vice wire nuts for specified wires in galley cabinet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 6 November 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 October 2007 Resolved
Provide emergency lighting in accomodation spaces below deck in accordance with 46 CFR 183.432. Vessel restricted from carrying overnight passengers until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 October 2007
Resolved 14 November 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 October 2007 Resolved
Secure microwave in galley from free movement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 6 November 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 October 2007 Resolved
Mark number of life jackets on stowage locations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 14 November 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 October 2007 Resolved
Provide full current first aid kit; missing splint ammonia inhalant, & iodine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 1 November 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 29 October 2007 Resolved
Provide currently corrected CG Light List for areas vessel transits (excerpts are acceptable).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 14 November 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 29 October 2007 Resolved
Install emergency fuel shut-off for generator fuel tank; mark shutoff in at least 1" letters indicating purpose & direction of operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 November 2007
Resolved 6 November 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 February 2007 Resolved
Conduct annual inspection IAW 46 CFR 176.500. Vessel exceeded 3-month window for re-inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2007
Resolved 15 February 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 February 2007 Resolved
Prove proper operation of starboard aft bilge alarm (both audible & visual).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2007
Resolved 16 February 2007
Communications › Radio Communications › EPIRB
Issued 15 February 2007 Resolved
Replace expired hydrostatic release for EPIRB. Vessel restricted to nmt 3 miles from shore until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2007
Resolved 16 February 2007
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 15 February 2007 Resolved
Provide proper weak link for 1 buoyant apparatus (18 person). Vessel restricted to nmt 34 persons (31 pax) until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2007
Resolved 16 February 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 15 February 2007 Resolved
Provide proper mounting bracket for portable fire extinguisher at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 13 March 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 February 2007 Resolved
Provide proper battery tray and protective shielding over or around batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 13 March 2007
Resolution: New battery tray and shield installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 February 2007 Resolved
Properly stow loose gear & tools in battery storage space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 13 March 2007
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 15 February 2007 Resolved
Provide updated charts & publications (U.S. Coast Pilot & CG Light List) for areas vessel transits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 16 February 2007
Lifesaving › Buoyant Apparatus › Marking
Issued 15 February 2007 Resolved
Renew vessel name on buoyant apparatus.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 13 March 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 February 2007 Resolved
Provide original certificate of documentation (COD). COD is valid, but not on-board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 13 March 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 December 2005 Resolved
Service portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2005
Resolution: Had portable fire extinguishers serviced.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 December 2005 Resolved
Service gas fixed systems
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2005
Resolution: Had gas fixed systems serviced.
Fire Fighting › Fire Bucket › Availability
Issued 13 December 2005 Resolved
Provide three (3) labeled fire buckets
Action required: 705 - Other - as specified
Due 27 December 2005
Resolved 15 December 2005
Resolution: Provide three (3) labeled fire buckets.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 13 December 2005 Resolved
Produce FCC radio safety certificate
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2005
Resolution: FCC radio safety certificate was renewed 14 Dec 05, expires 14 Dec 2010.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 January 2005 Resolved
COI not posted with all pages visible IAW 46 CFR 176.302.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2005
Resolved 1 May 2005
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 6 January 2005 Resolved
Raise and properly fasten (support) bilge pump and bilge alarm cables/wiring higher in compartments IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 6 February 2005
Resolved 1 May 2005
Communications › Radio Communications › EPIRB
Issued 5 November 2003 Resolved
Install new battery in EPIRB. Route restricted to lakes, bays and sounds until complete.
Due 19 December 2003
Resolved 19 December 2003
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 5 November 2003 Resolved
Install smoke detectors in berthing areas. Carry no passengers for hire until completed. LEGACY COMPONENT DESC: Berth
Due 19 December 2003
Resolved 2 December 2003
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 5 November 2003 Resolved
Stencil escape hatches. LEGACY COMPONENT DESC: Berth
Due 19 December 2003
Resolved 2 December 2003

Casualty record · 2

11 January 2005Routine · role: Involved in a Marine Casualty · activity 2279816
11 September 2019Routine · role: Involved in a Marine Casualty · activity 6813132
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.