MAURY USCG vessel records Sign in
← All vessels

SOUTHERN CROSS

SOUTHERN CROSS is a 1999 freight ship. The Coast Guard has recorded 26 inspections since 2000, most recently in April 2008, along with 19 deficiencies and 1 operational control.

Records from 2000 to 2008. Most recent: inspection, 3 April 2008.

Built
1999
Last inspected
3 April 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9197014 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
ITALY
—
Maury page id
psix-5076

Inspections, by type

…with no type recorded10
Years with a record 9 calendar years (2000–2008)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4410 - Convention (Subpart B), Gross Ton
4410 - Regulatory (Subpart C or D), Gross Ton
2240 - Convention (Subpart B), Net Ton
2240 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

3 April 2008 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3177143
6 October 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3071147
13 July 2006 Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2716319
1 June 2006 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2668810
4 December 2005 ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2545851
19 September 2005 Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2496675
2 June 2005 PII Safety Exam · Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2378553
10 November 2004 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2243142
4 September 2004 PII Safety Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2188577
14 July 2004 PII Safety Exam · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2136284
26 November 2003 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 1957506
12 November 2003 Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 1953771
14 May 2003 Annual Inspection
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 1797719
7 December 2002 Re-Inspection
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 1716482
30 May 2002 Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 1623822
17 April 2002 Annual Inspection
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 1606046
6 March 2002 Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 1604412
10 November 2001 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 295320
28 September 2001 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 532653
15 August 2001 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 511190
31 May 2001 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 441061
5 April 2001 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 288786
20 March 2001 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 288342
12 January 2001 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 522328
27 October 2000 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 283555
23 March 2000 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 276187

Deficiency record · 19

Electrical › Electric Generation Source (emergency) › Generator
Issued 1 June 2006 Resolved
Replace glass covering for emergency generator fuel shut off.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 1 August 2006
Resolved 13 July 2006
Resolution: Glass covering was replaced for emergency generator fuel shut off.
Construction/Loadline › Structures › Deck Plating
Issued 2 June 2005 Resolved
Replace severely wasted deck plate stbd side bow.
Action required: 15 - Rectify deficiencies by next port
Resolved 19 September 2005
Navigation › Piloting/Steering › Magnetic Compass
Issued 2 June 2005 Resolved
Magnetic compass unreadable, make adjustments to ensure compass is readable.
Action required: 15 - Rectify deficiencies by next port
Resolved 22 June 2005
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 2 June 2005 Resolved
Make proper repairs to MSD piping to the satisfaction of class.
Action required: 705 - Other - as specified
Resolved 19 September 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 June 2005 Resolved
Provide proof of servicing of fixed CO2 system, hose fittings corroded.
Due 2 July 2005
Resolved 22 June 2005
Pollution Prevention/Response › Prevention Equipment › Garbage Grinder/Comminuter
Issued 2 June 2005 Resolved
Prove proper operation of incinerator to the satisfaction of class.
Action required: 705 - Other - as specified
Resolved 19 September 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 July 2004 Resolved
Replace UV sun damaged lifelines on all ring lifebuoys.
Due 15 August 2004
Resolved 4 September 2004
Fire Fighting › Means of Escape › Escape Route Signs
Issued 14 July 2004 Resolved
Properly label all engine room emergency escape routes from within the engine space.
Due 15 August 2004
Resolved 4 September 2004
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 14 July 2004 Resolved
Conduct maintenance to emergency generator diesel prime mover's secondary hydraulic starting system and prove proper operation to the satisfaction of the attending classification society surveyor or U.S. Coast Guard marine inspector.
Condition: Improper/Lack of Maintenance
Due 15 August 2004
Resolved 4 September 2004
Construction/Loadline › Structures
Issued 17 April 2002 Resolved
Weathertight doors leading to superstructure on Poop Deck, CO2 Bottle Room, and Paint Locker were warped and did not seal properly. LEGACY COMPONENT DESC: Door
Condition: Unknown
Due 17 May 2002
Resolved 30 May 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 17 April 2002 Resolved
Missing nozzles on three (3) CO2 Portable Fire Extinguishers in engineroom (2 in Purifier Room and 1 in ECR). LEGACY COMPONENT DESC: Discharge Hose/Tube
Condition: Unknown
Due 17 May 2002
Resolved 30 May 2002
Navigation
Issued 20 March 2001 Resolved
The vessel did not have a Maneuvering Fact Sheet .
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Navigation
Issued 20 March 2001 Resolved
The Pre-arrival tests were not being looged.
Condition: Unknown
Due 14 April 2001
Resolved 19 July 2001
Deck/Cargo
Issued 20 March 2001 Resolved
The explosive cargo (Class 1.1) was not properly segregated from other hazardous materials onboard the vessel (Class 3 & 8).
Condition: Unknown
Due 14 April 2001
Resolved 19 July 2001
Engineering
Issued 20 March 2001 Resolved
The OWS does not have an alarm as indicated on the IOPP Certificate. Correct to the satisfaction of Class IAW MARPOL 73 / 78, Regulation 16.5 and SOLAS amended CH I, Regulation 11, prior to next U.S. Port.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Documentation
Issued 20 March 2001 Resolved
The flag state STCW certificate for some of the officers had expired. Correct IAW STCW 1978 Convention, CH II and CH III.
Condition: Unknown
Due 14 April 2001
Resolved 19 July 2001
Engineering
Issued 27 October 2000 Resolved
The vessel does not have adequate small discharge containment for the bilgeslop and sludge tank piping located on the main deck, port and starboard side forward of the superstructure.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Fire Fighting
Issued 27 October 2000 Resolved
The Fire Screen Doors located on the [name withheld], Boat Deck, and port sideengineroom emergency escape were not self-closing or did not close all the way. SOLAS amended Chapter II-2, Regulation 47.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Fire Fighting
Issued 27 October 2000 Resolved
The Paint Locker does not have adequate fire fighting protection. SOLAS amended Chapter II-2, Regulation 18.7.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000

Ownership record