MAURY USCG vessel records Sign in
← All vessels

MARIE CHERAMIE

MARIE CHERAMIE is a 2000 freight ship. The Coast Guard has recorded 43 inspections since 2000, most recently in December 2025, along with 49 deficiencies — 1 with no resolution recorded — and 5 casualty investigations between 2002 and 2010.

Records from 2000 to 2025. Most recent: inspection, 2 December 2025.

Built
2000
Last inspected
2 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8964862 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG4131
507836
Flag
UNITED STATES
367533290
Maury page id
psix-507836

Inspections, by type

…with no type recorded7
Years with a record 24 calendar years (2000–2025)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)152.7 ft × 44.0 ft × 12.0 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)152.7 ft × 44.0 ft × 12.0 ft
ITC tonnagegross 601 / net 180
BuilderMASTER BOAT BUILDERS, INC · CODEN, AL, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 August 2026 · expires 30 September 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it601 - Convention (Subpart B), Gross Ton
95 - Regulatory (Subpart C or D), Gross Ton
180 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG4131MMSI 367533290 · active · compulsorily equipped · granted 19 May 2022, expires 1 June 2032
WCZ7017MMSI 366778390 · expired · compulsorily equipped · granted 17 February 2010, cancelled 16 May 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS CHRISTINE II Commercial Fishing Vessel · MISLE 463788 · 23 August 2003 · activity 1897784GSF ADRIATIC IV Mobile Offshore Drilling Unit · MISLE 55175 · 20 October 2002 · activity 1694672

Inspection history · 43

2 December 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8243511
21 November 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8017413
16 September 2024 Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8003781
6 December 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7819950
15 September 2022 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7542579
24 May 2022 Deficiency Check · Administrative Inspection · Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7476660
22 October 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7338010
17 December 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7113451
8 December 2020 Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7109033
7 November 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6831001
19 September 2019 Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6814364
11 October 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6549202
19 September 2017 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6242651
30 August 2017 Hull Examination · Cargo Tank Internal · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6254615
9 February 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6075751
21 October 2016 MTSA/ISPS Verification · Construction Oversight · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6027170
9 October 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6027004
12 November 2015 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5762569
8 October 2014 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5000968
28 December 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4214367
14 February 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3945280
8 February 2010 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3676913
17 February 2009 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3435643
3 February 2009 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3400124
30 December 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3630181
27 February 2008 Hull Examination · Re-Inspection · Internal Structural Exam · Examination of Repairs · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3154217
29 May 2007 Ballast Water Examination · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2977554
4 April 2006 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2618002
25 February 2005 Internal Structural Exam · COI Inspection · MTSA Verification · Examination of Repairs · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2299122
2 March 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2016643
9 September 2003 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1900627
23 August 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1897784
8 July 2003 Damage Survey · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1840089
27 June 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1845843
18 February 2003 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1745830
23 October 2002 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1694745
20 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1694672
22 March 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1597816
12 December 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1490011
28 February 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389307
28 August 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1053219
29 March 2000 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1047241
18 February 2000 Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1410245

Deficiency record · 49

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2025 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel under way. Repair Port 24V switchboard cover on bridge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2025
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 December 2025 Resolved
Each hose on the station must have a fire nozzle approved under subpart 162.027. Marine Inspector observed Fire nozzle in FWD passage way is missing screw on handle allowing water to spray out. Fire nozzle in need of repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2025
Resolved 29 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 December 2025 Resolved
Materials used in Class II vital piping-systems may be accepted by the cognizant OCMI. Marine Inspector observed leak in Raycor primary filter drain on STBD Main Engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2025
Resolved 29 December 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2025 Resolved
Electric installations on vessels must ensure: protection of crew and the vessel from electrical hazards. Vessel’s wiring over stbd main engine is not adequately bundled and supported via metal hangers.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 28 January 2025
Resolution: MI observed wires properly secured in track ways during dfu.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 January 2025 Resolved
Where in this subchapter an item, or method of construction, or testing is required to meet the standards established by the American Bureau of Shipping, these shall be used. The tightness of tanks and tight boundaries is to be confirmed by test procedures for structures involved in, or affected by, repairs affecting structural integrity. Vessel deck and beams above starboard main diesel engine had been cut out and rewelded. No USCG or class surveyor was in attendance or reviewed a test procedure for this repair.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 28 January 2025
Resolution: MI observed crew demonstrate dye penetrant test of deck plate and engine room overhead.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 January 2025 Resolved
Navigation lights. Each self propelled vessel must have duplicate light sources for the side, masthead and stern lights. During inspection, port secondary running light was inoperable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 28 January 2025
Resolution: Port secondary light engergized during dfu.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 January 2025 Resolved
There shall be at least two means of escape from all general areas where the crew may be normally employed. Emergency escape scuttle to main deck from engine room is not adequately labeled as a means of escape and is capable of being locked from the exterior.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 28 January 2025
Resolution: Scuttle labeled during dfu.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2025 Resolved
Electric installations on vessels must ensure: protection of crew and the vessel from electrical hazards. Battery connections for port generator starting battery were secured to battery terminal via wing nuts.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 24 January 2025
Resolved 24 January 2025
Resolution: Cleared on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 November 2024 Resolved
Fire pumps must be fitted with a pressure gage on the discharge side of the pumps. Fire pump discharge pressure gage was not operational.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 24 January 2025
Resolved 24 January 2025
Resolution: Cleared on the spot.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 21 November 2024 No resolution recorded
The scope of the annual inspection is the same as the inspection for certification specified in § 91.25-10 but in less detail unless the cognizant marine inspector finds deficiencies or determines that a major change has occurred. The inspection shall insure that the vessel, as regards the structure, is in satisfactory condition. During NDT of cargo deck plate and frame replacement over stbd main diesel engine, noted incomplete fusion 1/8"x2" on the aft inboard lower side weld. Grind and re weld to acceptable tolerance next time vessel has welders on board or by next dry dock, whichever comes first.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2027
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 September 2022 Resolved
Each bilge system must comply with 46 CFR 56.50-50 and 56.50-55 of this chapter. During bilge suction test, bilge pump volute dripped water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2022
Resolution: Cleared during machinery follow up.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2022 Resolved
The inspection procedures for marine engineering systems contained in Subchapter F of this chapter apply. During engine room check and operation, noticed red coolant in bilge and fond to be coming from a small leak on an oring seal to metal fitted cooling sytem of starboard MDE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2022
Resolution: During machinery check, condition was rectified.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 October 2018 Resolved
During the inspection it was discovered that the watertight doors in the engine room were difficult to operate and that the door gaskets were not properly installed preventing the door from closing properly. Prove proper operation of the doors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2018
Resolved 12 October 2018
Resolution: Doors were found properly adjusted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2018 Resolved
During the inspection it was discovered that there were no deck coverings (electrical matting) on the deck at the main switchboards. Provide deck coverings
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2018
Resolved 12 October 2018
Resolution: New deck covering was installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2018 Resolved
Discovered the latch intended to hold the generator switchboard panel closed was missing. Provide a means of securing the panel closed.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2018
Resolved 12 October 2018
Resolution: A new latch was installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 October 2018 Resolved
During the inspection it was discovered that the crew was unable to demonstrate automated engine shutdowns. Prove proper operation of the main propulsion and auxiliary machinery shutdowns.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2018
Resolved 12 October 2018
Resolution: Tech reps demonstrated shut downs.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 October 2018 Resolved
Liferaft painters not secured.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2018
Resolution: Painter properly secured to weak link
Communications › Alarms/Indicators › High Water Alarm
Issued 19 September 2017 Resolved
Prove proper operation of high temp alarms on all equipment
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 28 September 2017
Resolution: all tests sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 September 2017 Resolved
Burn cream expired.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 28 September 2017
Resolution: Replaced
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 September 2017 Resolved
Eye wash expired
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 28 September 2017
Resolution: Replaced
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 9 February 2017 Resolved
Prove proper operation of anchor winches.
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 24 February 2017
Resolution: Anchors operated properly
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 February 2017 Resolved
Provide proper batteries for water-lights.
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 24 February 2017
Resolution: Batteries replaced
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 9 February 2017 Resolved
Provide light bulbs and protective lenses for bunk lights.
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 24 February 2017
Resolution: Light bulbs and protective lenses provided
Fire Fighting › Fire Pumps › Power Source
Issued 21 October 2016 Resolved
Fire pump was inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2016
Resolved 21 October 2016
Fire Fighting › Fire Main › Condition
Issued 21 October 2016 Resolved
Fire Main in way of the pump had a leak in the piping that had been attempted to be fixed with bondo.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2016
Resolved 8 December 2016
Resolution: Picture Sent of repair.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 October 2016 Resolved
Amp Meter was inoperable for the No. 1 Genrator
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 9 December 2016
Resolution: Cleared when new generators were installed.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 21 October 2016 Resolved
No fuel oil transfer procedures or line diagram posted at the fuel transfer manifold.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 31 October 2016
Resolution: Procedures posted
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 October 2016 Resolved
Outletr cover busted and missing in Asst. Captain's stateroom
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 31 October 2016
Resolution: Cover installed
Lifesaving › Rocket Parachute Flares › General
Issued 8 October 2014 Resolved
46 CFR 133.60- Vessel required 12 parachute flares. Vessel only had 06 parachute and 6 orange flares onboard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2014
Resolution: Verified 12 parachute flares onboard.
Communications › Audible Communications › Horn/Whistle
Issued 8 October 2014 Resolved
33 CFR 83.33- Vessels of 12 meters or more in length shall be provided with a whistle. Whistle would not operate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2014
Resolution: Witnessed test, all sat.
Construction/Loadline › Structures › Door
Issued 8 October 2014 Resolved
46 CFR 170.270- Each Class 1 watertight door must have a quick action closing device operative from both sides of the door. Forward engine room door could not be operated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2014
Resolution: WTD repair and tested, Sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 8 October 2014 Resolved
33 CFR 155.780- Means to stop flow of cargo must be operable from the cargo deck. The emergency stop for the liquid mud pumps did not work during tests.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2014
Resolution: Master was not familar with the proper test proceedures. During retest on 09OCT2014 the stop start button on the deck was used, test sat.
Construction/Loadline › Structures › Ventilators
Issued 8 October 2014 Resolved
46 CFR 127.250- Means must be provided for closing a vent which serves a machinery space in case of fire. Machinery space intake vent STBD side was removed to change fan motor and was not in place for inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2017
Resolution: Intake vent STBD side was placed back in position.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 8 October 2014 Resolved
46 CFR 174.195- The bulkhead in each machinery space of each OSV must watertight to the bulkhead deck. Each penetration needs a means to make watertight. The ROX installation in the E/R and the Bow Thruster space had modifications which were not IAW manufactures installation procedures. Multiple wires passing through single blocks and holes drilled through solid spacers, which failed tests.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2014
Resolution: Rox installations corrected and tested sat.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 October 2014 Resolved
33 CFR 155 5015 Vessel measured 601 ITC required and require to have a NTVRP. Vessel does not does not have an approved NTVRP. Submit plan and provide documentation from the NTVRP help desk.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2014
Resolution: Received Salvage and OSRO contracts and QI and ALT identified.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 October 2014 Resolved
Vessel does not have an approved NTVRP. Vessel did secure an OSRO, Salvor and identified a QI and ALT. Plan has been submitted awaiting approval.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 November 2014
Resolved 27 October 2014
Resolution: Received a copy of the approval letter for the NTVRP.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 28 December 2011 Resolved
Data plate was painted over and unreadable
Due 28 January 2012
Resolved 28 December 2011
Resolution: removed paint
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 28 December 2011 Resolved
Liquid mud tank vent screen and float ball were severely corroded with part of the screen missing
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2011
Resolution: Replaced vent
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 3 February 2009 Resolved
Repair leak at fuel transfer pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2009
Lifesaving › Lifebuoys
Issued 18 February 2003 Resolved
Repair or replace broken light on ring buouy, 02 deck stbd. side. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2003
Resolved 26 February 2003
Electrical › Electrical Distribution System (service)
Issued 18 February 2003 Resolved
Repair lights on the main switchboard. LEGACY COMPONENT DESC: Switchboard
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 26 February 2003
Construction/Loadline › Markings
Issued 18 February 2003 Resolved
Paint draft marks. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 26 February 2003
Construction/Loadline › Markings
Issued 18 February 2003 Resolved
Paint loadline marks. LEGACY COMPONENT DESC: Load Line Mark
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 26 February 2003
Construction/Loadline › Markings
Issued 18 February 2003 Resolved
Paint vessel name and homeport. LEGACY COMPONENT DESC: Vessel Name/Home Port
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 26 February 2003
Lifesaving › Line-Throwing Appliances
Issued 18 February 2003 Resolved
Proved (1) coil of line for line throwing gun. LEGACY COMPONENT DESC: Lines
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2003
Resolved 26 February 2003
Operations/Management › Drills/Instruction
Issued 18 February 2003 Resolved
Provide Life Saving Signals & Helicopter Recovery Placard. LEGACY COMPONENT DESC: Life Saving Signals & Helicopter Recovery Placard
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 26 February 2003
Communications › Alarms/Indicators
Issued 18 February 2003 Resolved
Provide shaft tachometers in the pilot house as per 46 CFR 113.37. LEGACY COMPONENT DESC: Propeller Speed Indicator
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 2 March 2004
Documentation
Issued 18 February 2000 Resolved
PROVIDE COPY OF WASTE MGT PLAN & TRASH LOG.
Condition: Unknown
Due 22 February 2000
Resolved 23 February 2000
Documentation
Issued 18 February 2000 Resolved
PROVIDE COPY OF PERM. RADIO CALL SIGN
Condition: Unknown
Due 18 February 2000
Resolved 18 February 2000

Casualty record · 5

20 October 2002Routine · role: Involved in a Marine Casualty · activity 1694672
27 June 2003Routine · role: Involved in a Marine Casualty · activity 1845843
23 August 2003Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1897784
30 December 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3630181
8 February 2010Routine · role: Involved in a Marine Casualty · activity 3676913
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

RACHEL CALLAIS (2002–2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.