Inspection history · 17
2 December 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8243511
21 November 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8017413
16 September 2024
Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8003781
6 December 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7819950
15 September 2022
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7542579
24 May 2022
Deficiency Check · Administrative Inspection · Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7476660
22 October 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7338010
17 December 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7113451
8 December 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7109033
7 November 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6831001
19 September 2019
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6814364
11 October 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6549202
19 September 2017
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6242651
30 August 2017
Hull Examination · Cargo Tank Internal · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6254615
9 February 2017
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6075751
21 October 2016
MTSA/ISPS Verification · Construction Oversight · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6027170
9 October 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6027004
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2025
Resolved
Electrical equipment and installations must be suitable
for the roll, pitch, and vibration of the vessel under
way. Repair Port 24V switchboard cover on bridge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2025
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 December 2025
Resolved
Each hose on the station must have a fire nozzle
approved under subpart 162.027. Marine Inspector observed Fire nozzle in FWD passage way is missing screw on handle allowing water to spray out. Fire nozzle in need of repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2025
Resolved 29 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 December 2025
Resolved
Materials used in Class II vital piping-systems may be
accepted by the cognizant OCMI. Marine Inspector observed leak in Raycor primary filter drain on STBD Main Engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2025
Resolved 29 December 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2025
Resolved
Electric installations on vessels must ensure: protection of crew and the vessel from electrical hazards. Vessel’s wiring over stbd main engine is not adequately bundled and supported via metal hangers.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 28 January 2025
Resolution: MI observed wires properly secured in track ways during dfu.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 January 2025
Resolved
Where in this subchapter an item, or method of construction, or testing is required to meet the standards established by the American Bureau of Shipping, these shall be used. The tightness of tanks and tight boundaries is to be confirmed by test procedures for structures involved in, or affected by, repairs affecting structural integrity. Vessel deck and beams above starboard main diesel engine had been cut out and rewelded. No USCG or class surveyor was in attendance or reviewed a test procedure for this repair.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 28 January 2025
Resolution: MI observed crew demonstrate dye penetrant test of deck plate and engine room overhead.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 January 2025
Resolved
Navigation lights. Each self propelled vessel must have duplicate light sources for the side, masthead and stern lights. During inspection, port secondary running light was inoperable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 28 January 2025
Resolution: Port secondary light engergized during dfu.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 January 2025
Resolved
There shall be at least two means of escape from all general areas where the crew may be normally employed. Emergency escape scuttle to main deck from engine room is not adequately labeled as a means of escape and is capable of being locked from the exterior.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 28 January 2025
Resolution: Scuttle labeled during dfu.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2025
Resolved
Electric installations on vessels must ensure: protection of crew and the vessel from electrical hazards. Battery connections for port generator starting battery were secured to battery terminal via wing nuts.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 24 January 2025
Resolved 24 January 2025
Resolution: Cleared on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 November 2024
Resolved
Fire pumps must be fitted with a pressure gage on the discharge side of the pumps. Fire pump discharge pressure gage was not operational.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 24 January 2025
Resolved 24 January 2025
Resolution: Cleared on the spot.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 21 November 2024
No resolution recorded
The scope of the annual inspection is the same as the inspection for certification specified in § 91.25-10 but in less detail unless the cognizant marine inspector finds deficiencies or determines that a major change has occurred. The inspection shall insure that the vessel, as regards the structure, is in satisfactory condition. During NDT of cargo deck plate and frame replacement over stbd main diesel engine, noted incomplete fusion 1/8"x2" on the aft inboard lower side weld. Grind and re weld to acceptable tolerance next time vessel has welders on board or by next dry dock, whichever comes first.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2027
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 September 2022
Resolved
Each bilge system must comply with 46 CFR 56.50-50 and 56.50-55 of this chapter. During bilge suction test, bilge pump volute dripped water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2022
Resolution: Cleared during machinery follow up.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2022
Resolved
The inspection procedures for marine engineering systems contained in Subchapter F of this chapter apply. During engine room check and operation, noticed red coolant in bilge and fond to be coming from a small leak on an oring seal to metal fitted cooling sytem of starboard MDE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2022
Resolution: During machinery check, condition was rectified.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 October 2018
Resolved
During the inspection it was discovered that the watertight doors in the engine room were difficult to operate and that the door gaskets were not properly installed preventing the door from closing properly. Prove proper operation of the doors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2018
Resolved 12 October 2018
Resolution: Doors were found properly adjusted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2018
Resolved
During the inspection it was discovered that there were no deck coverings (electrical matting) on the deck at the main switchboards. Provide deck coverings
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2018
Resolved 12 October 2018
Resolution: New deck covering was installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2018
Resolved
Discovered the latch intended to hold the generator switchboard panel closed was missing. Provide a means of securing the panel closed.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2018
Resolved 12 October 2018
Resolution: A new latch was installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 October 2018
Resolved
During the inspection it was discovered that the crew was unable to demonstrate automated engine shutdowns. Prove proper operation of the main propulsion and auxiliary machinery shutdowns.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2018
Resolved 12 October 2018
Resolution: Tech reps demonstrated shut downs.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 October 2018
Resolved
Liferaft painters not secured.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2018
Resolution: Painter properly secured to weak link
Communications › Alarms/Indicators › High Water Alarm
Issued 19 September 2017
Resolved
Prove proper operation of high temp alarms on all equipment
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 28 September 2017
Resolution: all tests sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 September 2017
Resolved
Burn cream expired.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 28 September 2017
Resolution: Replaced
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 September 2017
Resolved
Eye wash expired
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 28 September 2017
Resolution: Replaced
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 9 February 2017
Resolved
Prove proper operation of anchor winches.
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 24 February 2017
Resolution: Anchors operated properly
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 February 2017
Resolved
Provide proper batteries for water-lights.
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 24 February 2017
Resolution: Batteries replaced
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 9 February 2017
Resolved
Provide light bulbs and protective lenses for bunk lights.
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 24 February 2017
Resolution: Light bulbs and protective lenses provided
Fire Fighting › Fire Pumps › Power Source
Issued 21 October 2016
Resolved
Fire pump was inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2016
Resolved 21 October 2016
Fire Fighting › Fire Main › Condition
Issued 21 October 2016
Resolved
Fire Main in way of the pump had a leak in the piping that had been attempted to be fixed with bondo.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2016
Resolved 8 December 2016
Resolution: Picture Sent of repair.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 October 2016
Resolved
Amp Meter was inoperable for the No. 1 Genrator
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 9 December 2016
Resolution: Cleared when new generators were installed.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 21 October 2016
Resolved
No fuel oil transfer procedures or line diagram posted at the fuel transfer manifold.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 31 October 2016
Resolution: Procedures posted
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 October 2016
Resolved
Outletr cover busted and missing in Asst. Captain's stateroom
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 31 October 2016
Resolution: Cover installed