MAURY USCG vessel records
← All vessels

MARIE CHERAMIE

Built
2000
Last inspected
2 December 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 December 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8964862
WDG4131
507836
Flag
UNITED STATES
Maury page id
psix-507836

Documentation record

Registered dimensions (L × B × D)152.7 ft × 44.0 ft × 12.0 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)152.7 ft × 44.0 ft × 12.0 ft
ITC tonnagegross 601 / net 180
BuilderMASTER BOAT BUILDERS, INC · CODEN, AL, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 30 September 2025 · expires 30 September 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it601 - Convention (Subpart B), Gross Ton
95 - Regulatory (Subpart C or D), Gross Ton
180 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

2 December 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8243511
21 November 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8017413
16 September 2024 Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8003781
6 December 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7819950
15 September 2022 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7542579
24 May 2022 Deficiency Check · Administrative Inspection · Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7476660
22 October 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7338010
17 December 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7113451
8 December 2020 Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7109033
7 November 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6831001
19 September 2019 Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6814364
11 October 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6549202
19 September 2017 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6242651
30 August 2017 Hull Examination · Cargo Tank Internal · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6254615
9 February 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6075751
21 October 2016 MTSA/ISPS Verification · Construction Oversight · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6027170
9 October 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6027004

Deficiency record · 28

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2025 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel under way. Repair Port 24V switchboard cover on bridge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2025
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 December 2025 Resolved
Each hose on the station must have a fire nozzle approved under subpart 162.027. Marine Inspector observed Fire nozzle in FWD passage way is missing screw on handle allowing water to spray out. Fire nozzle in need of repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2025
Resolved 29 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 December 2025 Resolved
Materials used in Class II vital piping-systems may be accepted by the cognizant OCMI. Marine Inspector observed leak in Raycor primary filter drain on STBD Main Engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2025
Resolved 29 December 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2025 Resolved
Electric installations on vessels must ensure: protection of crew and the vessel from electrical hazards. Vessel’s wiring over stbd main engine is not adequately bundled and supported via metal hangers.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 28 January 2025
Resolution: MI observed wires properly secured in track ways during dfu.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 January 2025 Resolved
Where in this subchapter an item, or method of construction, or testing is required to meet the standards established by the American Bureau of Shipping, these shall be used. The tightness of tanks and tight boundaries is to be confirmed by test procedures for structures involved in, or affected by, repairs affecting structural integrity. Vessel deck and beams above starboard main diesel engine had been cut out and rewelded. No USCG or class surveyor was in attendance or reviewed a test procedure for this repair.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 28 January 2025
Resolution: MI observed crew demonstrate dye penetrant test of deck plate and engine room overhead.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 January 2025 Resolved
Navigation lights. Each self propelled vessel must have duplicate light sources for the side, masthead and stern lights. During inspection, port secondary running light was inoperable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 28 January 2025
Resolution: Port secondary light engergized during dfu.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 January 2025 Resolved
There shall be at least two means of escape from all general areas where the crew may be normally employed. Emergency escape scuttle to main deck from engine room is not adequately labeled as a means of escape and is capable of being locked from the exterior.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 28 January 2025
Resolution: Scuttle labeled during dfu.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2025 Resolved
Electric installations on vessels must ensure: protection of crew and the vessel from electrical hazards. Battery connections for port generator starting battery were secured to battery terminal via wing nuts.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 24 January 2025
Resolved 24 January 2025
Resolution: Cleared on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 November 2024 Resolved
Fire pumps must be fitted with a pressure gage on the discharge side of the pumps. Fire pump discharge pressure gage was not operational.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 24 January 2025
Resolved 24 January 2025
Resolution: Cleared on the spot.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 21 November 2024 No resolution recorded
The scope of the annual inspection is the same as the inspection for certification specified in § 91.25-10 but in less detail unless the cognizant marine inspector finds deficiencies or determines that a major change has occurred. The inspection shall insure that the vessel, as regards the structure, is in satisfactory condition. During NDT of cargo deck plate and frame replacement over stbd main diesel engine, noted incomplete fusion 1/8"x2" on the aft inboard lower side weld. Grind and re weld to acceptable tolerance next time vessel has welders on board or by next dry dock, whichever comes first.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2027
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 September 2022 Resolved
Each bilge system must comply with 46 CFR 56.50-50 and 56.50-55 of this chapter. During bilge suction test, bilge pump volute dripped water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2022
Resolution: Cleared during machinery follow up.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2022 Resolved
The inspection procedures for marine engineering systems contained in Subchapter F of this chapter apply. During engine room check and operation, noticed red coolant in bilge and fond to be coming from a small leak on an oring seal to metal fitted cooling sytem of starboard MDE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2022
Resolution: During machinery check, condition was rectified.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 October 2018 Resolved
During the inspection it was discovered that the watertight doors in the engine room were difficult to operate and that the door gaskets were not properly installed preventing the door from closing properly. Prove proper operation of the doors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2018
Resolved 12 October 2018
Resolution: Doors were found properly adjusted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2018 Resolved
During the inspection it was discovered that there were no deck coverings (electrical matting) on the deck at the main switchboards. Provide deck coverings
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2018
Resolved 12 October 2018
Resolution: New deck covering was installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2018 Resolved
Discovered the latch intended to hold the generator switchboard panel closed was missing. Provide a means of securing the panel closed.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2018
Resolved 12 October 2018
Resolution: A new latch was installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 October 2018 Resolved
During the inspection it was discovered that the crew was unable to demonstrate automated engine shutdowns. Prove proper operation of the main propulsion and auxiliary machinery shutdowns.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2018
Resolved 12 October 2018
Resolution: Tech reps demonstrated shut downs.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 October 2018 Resolved
Liferaft painters not secured.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2018
Resolution: Painter properly secured to weak link
Communications › Alarms/Indicators › High Water Alarm
Issued 19 September 2017 Resolved
Prove proper operation of high temp alarms on all equipment
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 28 September 2017
Resolution: all tests sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 September 2017 Resolved
Burn cream expired.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 28 September 2017
Resolution: Replaced
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 September 2017 Resolved
Eye wash expired
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 28 September 2017
Resolution: Replaced
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 9 February 2017 Resolved
Prove proper operation of anchor winches.
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 24 February 2017
Resolution: Anchors operated properly
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 February 2017 Resolved
Provide proper batteries for water-lights.
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 24 February 2017
Resolution: Batteries replaced
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 9 February 2017 Resolved
Provide light bulbs and protective lenses for bunk lights.
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 24 February 2017
Resolution: Light bulbs and protective lenses provided
Fire Fighting › Fire Pumps › Power Source
Issued 21 October 2016 Resolved
Fire pump was inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2016
Resolved 21 October 2016
Fire Fighting › Fire Main › Condition
Issued 21 October 2016 Resolved
Fire Main in way of the pump had a leak in the piping that had been attempted to be fixed with bondo.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2016
Resolved 8 December 2016
Resolution: Picture Sent of repair.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 October 2016 Resolved
Amp Meter was inoperable for the No. 1 Genrator
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 9 December 2016
Resolution: Cleared when new generators were installed.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 21 October 2016 Resolved
No fuel oil transfer procedures or line diagram posted at the fuel transfer manifold.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 31 October 2016
Resolution: Procedures posted
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 October 2016 Resolved
Outletr cover busted and missing in Asst. Captain's stateroom
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 31 October 2016
Resolution: Cover installed

Recorded names · 1

RACHEL CALLAIS (2002–2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.