← All vessels
NWM 119
NWM 119 is a 1971 tank barge. The Coast Guard has recorded 86 inspections since 1981, most recently in October 2015, along with 17 deficiencies — 1 with no resolution recorded —.
Records from 1981 to 2015. Most recent: inspection, 5 October 2015.
- Built
- 1971
- Last inspected
- 5 October 2015
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
531695
50789
Flag
UNITED STATES
—
Maury page id
psix-50789
Inspections, by type
…with no type recorded34
…past their stated due date1
Years with a record
33 calendar years (1981–2015)
The 86 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it798 - Regulatory (Subpart C or D), Gross Ton
798 - Regulatory (Subpart C or D), Net Ton
798 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 86
5 October 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5752604
14 January 2015
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5068123
11 December 2014
Annual Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5036717
10 September 2013
Internal Structural Exam · Examination of Repairs · MTSA Verification · COI Inspection · Drydock Exam · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4655094
28 June 2011
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4060582
5 October 2010
COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3863584
4 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3862978
24 August 2010
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3832485
5 May 2009
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3468814
27 March 2009
Damage Survey
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3449089
14 January 2008
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3130849
5 October 2007
Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3073763
25 September 2007
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3066791
21 September 2007
Examination of Repairs · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3062919
3 July 2007
Permit to Proceed
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2985364
29 June 2007
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2977835
22 January 2007
Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2860964
27 October 2006
Examination of Repairs
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2809406
23 June 2006
COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2688994
7 April 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2619410
4 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2450961
11 May 2005
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2356006
25 March 2005
MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2319230
25 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2319423
10 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2238515
26 April 2004
Periodic Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2053187
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1983831
29 April 2003
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1782834
24 June 2002
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1639608
17 May 2002
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1617885
15 January 2002
Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1475962
3 October 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 516801
13 July 2001
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1382332
6 March 2001
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1058190
25 October 2000
Deficiency Check · Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1395552
26 August 1999
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1471875
6 October 1998
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 801203
21 July 1998
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 444839
19 September 1997
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1443913
19 July 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 445060
22 May 1997
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 760170
21 May 1997
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 203462
21 May 1997
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 466594
31 January 1997
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1103848
3 December 1996
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1425823
6 November 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 472617
28 October 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 756347
25 October 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 201239
9 October 1996
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 850149
20 November 1995
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1187874
26 April 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 439488
24 March 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 443114
28 February 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 460023
27 December 1994
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 851922
2 June 1994
Examination of Repairs · Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1321253
13 April 1994
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 494714
17 December 1993
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 853984
17 December 1993
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 853985
12 July 1993
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 642138
7 July 1993
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 45134
14 June 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 446345
13 April 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 460179
21 January 1993
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1139069
9 October 1992
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 483442
4 June 1992
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 441891
6 February 1992
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 957202
28 January 1992
Hull Examination · Examination of Repairs · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1373708
3 May 1991
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 517601
30 October 1990
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1233071
10 July 1990
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 507599
8 December 1989
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1234418
16 November 1989
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 497924
30 March 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1203885
30 January 1989
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 518346
9 June 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 529021
22 January 1988
COI Inspection · MARPOL Annex II Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017052
15 October 1987
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 532870
17 February 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016464
6 October 1986
Type not recorded
No type recorded · MSO NASHVILLE · Activity 467437
28 July 1986
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 447662
22 March 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306575
8 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289375
6 July 1984
Type not recorded
No type recorded · MSO CINCINNATI · Activity 473959
22 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278931
7 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276112
6 January 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971176
Deficiency record · 17
Documentation › Logs/Records › Declaration of Inspection
Issued 11 December 2014
Resolved
Declaration of Inspection for last 30 days should be kept onboard vsl in accordance with 33 CFR 156.150(f). Provide means for stowing DOIs within the vsl.
Pollution Prevention/Response › Response Equipment › Containers
Issued 11 December 2014
Resolved
Starboard containment is full. Containment shall be cleared as required by 33 CFR 156.120(n).
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 11 December 2014
Resolved
All cargo hoses must be properly tested annually as required by 33 CFR 156.170. Hoses onboard shall not be used until properly tested.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 December 2014
Resolved
Provide 2 fully serviced B-II portable fire extinguishers for use during cargo operations in accordance with 46 CFR 31.10-12(a), Prior to cargo ops.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 11 December 2014
Resolved
Prove accuracy of cargo pump pressure gauge in presence of Marine Inspector in accordance with 46 CFR 35.35-7(b), Prior to cargo ops.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 11 December 2014
Resolved
Prove satisfactory test of cargo pump pressure relief valve in presence of Marine Inspector in accordance with 46 CFR 35.35-70(b), Prior to cargo ops.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 11 December 2014
Resolved
Vapor collection flanges have improper stud placement. Correct in accordance with 46 CFR 39.20-1(b).
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 11 December 2014
Resolved
Viewing glass wipers do not work. Replace wipers on tanks 1 & 2 sight glasses. Additionally, ref mark should be placed inside viewing area to provide loading reference in accordance with transfer procedures per 46 CFR 39.20-3
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 11 December 2014
No resolution recorded
Port timberhead is damaged. Repair or replace in accordance with 46 CFR 32.15-15.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 30 September 2013
Resolved
Vessel's VCS approval letter from MSC, Serial#C-020276 is not available in vessel's file. Prior to loading cargoes requiring vapor collection, vessel rep must provide a copy of the original approval letter listing the Sub. D cargoes approved for vapor collection, OR receive a new approval letter from MSC and associated CAA listing sub. D cargoes which are approved for vapor collection.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 27 March 2009
Resolved
Determine source of cargo leak into #2 void and provide a repair proposal to the cognizant [name withheld] approval of proposed repair, make permanent repairs.
Construction/Loadline › Hull › Hull Plating
Issued 27 March 2009
Resolved
Repair as original fractures in the stbd side rake knuckle and deck knuckle. One fracture along deck knuckle stbd side 15' aft of head log and one fracture stbd side along bilge lap at 4' draft mark.
Construction/Loadline › Hull › Bottom Plating
Issued 29 June 2007
Resolved
T/B AO 119 is authorized to transit in loaded condition to Citgo, Inc dock, Lemont, IL (mm 297.5 CSSC), discharge cargo, and prepare bow void for entry by CG inspector to assess condition of botom plating where fractured iwo vertical truss #2, bottom of rake, 6 ft stbd of center. No other operations are permitted until authorized by the cognizant OCMI.
Deck/Cargo
Issued 25 October 2000
Resolved
CLEAN RUST AND SCALE FROM THE VAPOR HEADER PRIOR TO ANY LOADING OF CARGO.
Deck/Cargo
Issued 25 October 2000
Resolved
INSTALL NEW RUBBER GASKET SEAL ON VAPOR CONTROL VALVE ON THE #3 CARGO TANK PRIOR TO LOADING ANY CARGO.
Engineering
Issued 28 January 1992
Resolved
Provide a 2-1/2" vent in the cargo pump engine fuel tank as required by 46CFR56.50-75(b)(7) and 46CFR56.50-85(a)(9) prior to the compliance date.
Deck/Cargo
Issued 7 April 1982
Resolved
RENEWED BOW KNUCKLE PLATE AS REQUIRED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.