MAURY USCG vessel records Sign in
← All vessels

WAITIN ON 2 EXPRESS

WAITIN ON 2 EXPRESS is a 1999 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1999, most recently in April 2026, along with 67 deficiencies.

Records from 1999 to 2026. Most recent: inspection, 20 April 2026.

Built
1999
Last inspected
20 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ3735
507945
Flag
UNITED STATES
367770850
Maury page id
psix-507945

Inspections, by type

…with no type recorded1
Years with a record 24 calendar years (1999–2026)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 8.0 ft × 4.0 ft
Registered tonnagegross 6 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCWS INC · LAKE HAVASU CITY, AZ, UNITED STATES · built 1999
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portMURRELLS INLET, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ3735MMSI 367770850 · active · compulsorily equipped · granted 1 February 2017, expires 1 February 2027
WDB5753MMSI 366913010 · expired · compulsorily equipped · granted 14 November 2003, cancelled 18 January 2014 · licensed under a name not among this hull’s recorded names (not shown)
WCZ6849MMSI not assigned · expired · compulsorily equipped · granted 2 March 2000, cancelled 8 May 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 55

20 April 2026 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8353520
8 April 2025 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8108722
15 October 2024 Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8019889
15 April 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7895957
24 October 2023 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7814397
24 April 2023 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7674794
26 April 2022 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7438712
15 October 2021 Drydock Exam · Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7332899
3 May 2021 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7185056
26 October 2020 Hull Examination · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7082859
23 June 2020 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6983551
4 October 2019 Examination of Repairs · Plan Review "T" Boat
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6829588
29 April 2019 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6661284
25 February 2019 Examination of Repairs · Plan Review "T" Boat
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6632510
3 December 2018 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6594547
15 October 2018 Hull Examination · Examination of Repairs · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6561806
22 May 2018 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6412068
26 September 2017 Simplified Stability Test
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6275686
29 June 2017 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6208175
21 March 2017 COI Inspection · In-Service Inspection · Examination of Repairs · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6089887
21 October 2016 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6026922
6 October 2016 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6017630
28 October 2015 Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5752650
2 October 2014 Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4997585
12 July 2012 Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4377954
5 June 2012 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4334418
16 December 2011 Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4209287
27 September 2011 Type not recorded
No type recorded · Boat Forces Unit United States Virgin Islands · USCG Southeast District (CGD-SE) · Activity 4156287
28 July 2011 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4096845
14 July 2011 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4080967
26 January 2011 Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3933661
13 December 2010 Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3909775
2 November 2010 Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3937938
14 May 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3474786
19 February 2009 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3420167
12 November 2008 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3361398
9 June 2008 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3231465
6 May 2008 Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3199835
15 February 2007 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2872972
1 June 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2375641
12 April 2005 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2331963
25 February 2005 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2299070
9 August 2004 Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2161873
6 July 2004 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2123258
2 June 2004 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2086392
7 May 2004 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2061566
23 March 2004 MARPOL Annex I Examination · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2030196
6 March 2004 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2019429
27 February 2004 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2026101
9 February 2004 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2009339
28 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996407
15 January 2003 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1730783
11 December 2001 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1716070
31 December 1999 Hull Examination · MARPOL Annex V Examination · Initial Certification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1444283
19 November 1999 Initial Construction-Excluding Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1393279

Deficiency record · 67

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 May 2022 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Racor filters have plastic bowls installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2022
Resolved 18 May 2022
Resolution: replaced with aluminum fuel bowls
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 May 2022 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter. Water light battery is expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2022
Resolved 18 May 2022
Resolution: Replaced the water light battery
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 May 2022 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Wrong placard is posted.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2022
Resolved 18 May 2022
Resolution: placed proper placard in place.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 May 2022 Resolved
Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter. 3 adult and 1 child was removed from service, replacements were brought onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 May 2022
Resolution: replacement life jackets were placed in service.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 October 2021 Resolved
All accessible parts of the vessels underwater body including hull, appendages, and propellors shall be made avaialable for inspection during a drydock inspection. Vessels port inboard sponson was delaminating along the lower seam where it meets the lower track/mounting location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 4 January 2022
Resolution: Sponsons have been removed from the vessel and taken to a third party service facility for repair. A spare set of sponsons have been installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2021 Resolved
All accessible parts of the vessels underwater body including hull, appendages, and propellors shall be made avaialable for inspection during a drydock inspection. The port inboard trim/tilt hydraulic ram assembly seal was damaged/leaking.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 4 January 2022
Resolution: Repair effected by third party repair facility (Marine Service Center).
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 October 2021 Resolved
A complete examination of the vessels main strength members and planking, voids and fuel tanks shall be conducted during an internal structural examination. Vessels weathertight hatches #1 & #3 (from bow)securing hardware were damaged/missing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 4 January 2022
Resolution: O/O installed new hatches IWO voids #1 & #3.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2021 Resolved
Vessel required to carry adult Type I PFD's for each person on board. Existing PFD (x9) were found unserviceable due to UV deterioration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 31 August 2021
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 3 May 2021 Resolved
Installed toilets on board vessels are required to be equipped with operating instructions. Existing installed toilet is not equipped with operating instructions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 31 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 May 2021 Resolved
Vessel required to be fitted with a stern light. Existing stern light bracket was broken/required replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 31 August 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 October 2018 Resolved
Vessels exterior hull IWO port/centerline in the aft 3/4 length of vessel was found delaminated. Affected area to be ground for further inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2018
Resolved 2 November 2018
Resolution: Attending Inspector(s) verified repairs to vessels hull.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 October 2018 Resolved
Vessels exterior hull contained minor nicks & moderate gouges IWO starboard side hull (fwd). Affected area to be ground for further inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2018
Resolved 2 November 2018
Resolution: Attending Inspector(s) verified repairs made to vessels starboard side hull.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 October 2018 Resolved
Vessels main deck IWO starboard side (under bench seating) was found fractured (stress). Affected area to be ground for further inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2018
Resolved 2 November 2018
Resolution: Attending Inspector(s) verified repairs made to vessels main deck (starboard side).
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 June 2017 Resolved
PFD stowage markings did not reflect actual qty of PFD's stowed.
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 29 June 2017
Resolution: Attending Inspector verified PFD stowage markings (type/qty).
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 6 June 2017 Resolved
Vessel not equipped with current/up to date tidal current tables.
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 29 June 2017
Resolution: Attending Inspector verified carriage of current/up to date navigational publications for areas transited.
Engineering › Bilge Water Management System › Valve
Issued 6 June 2017 Resolved
Vessel not equipped with stop valves for bilge discharge lines.
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 29 June 2017
Resolution: Attending Inspector verified installation of stop valves in way of bilge pump discharge piping.
Navigation › Piloting/Steering › Magnetic Compass
Issued 6 June 2017 Resolved
Vessels compass was not illuminated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 29 June 2017
Resolution: Attending Inspector verified the illumination of the compass (newly installed).
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 21 October 2016 Resolved
Complete DAPI audit with attending CG marine inspector.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 3 November 2016
Resolution: Completed DAPI Audit.
Lifesaving › Hand Flares › Quantity
Issued 28 October 2015 Resolved
Provide a total of 12 flares. Vessel missing 2 flares.
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 28 October 2015
Resolution: Flares replaced on vessel.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 October 2015 Resolved
Prove proper operation of high water alarm for bilges.
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 19 November 2015
Resolution: High water alarm operationally tested.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 October 2015 Resolved
Make ring buoy water light tether 3-6 feet in length.
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 19 November 2015
Resolution: New tether installed.
Construction/Loadline › Hull › Side Shell
Issued 28 October 2015 Resolved
Make vessel available for collar stress test.
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 19 November 2015
Resolution: Stress test completed. See narative for details.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 October 2015 Resolved
Post radio call sign on Emergency boradcast placard.
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 19 November 2015
Resolution: Placard posted.
Communications › Radio Communications › EPIRB
Issued 2 October 2014 Resolved
Provide current EPIRB registration.
Action required: 705 - Other - as specified
Due 16 October 2014
Resolved 2 October 2014
Resolution: Received EPIRB registration from vessel rep via email.
Engineering › Bilge Water Management System › Not Operational
Issued 12 July 2012 Resolved
Prove operation of audible and visual alarm for bilge system per 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 27 August 2013
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 July 2012 Resolved
Provide unexpired burn gel and eye flush for first aid kit per 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 27 August 2013
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 May 2009 Resolved
Ensure that all portable fire extinguishers are inspected and maintained in accordance with Chapter 4, NFPA 10.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2009
Resolved 25 May 2009
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 14 May 2009 Resolved
Ensure that pre-engineered fire extinguisher located in the fuel tank compartment has been inspected and tested in accordance with 46 CFR 176.810(b)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2009
Resolved 25 May 2009
Fire Fighting › Fire Bucket › Availability
Issued 6 May 2008 Resolved
Provide three 2.5 gallon fire buckets
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 9 June 2008
Resolution: Vessel has three fire buckets onboard
Engineering › Bilge Water Management System › Hose
Issued 6 May 2008 Resolved
Provide hose for portable bilge pump.
Action required: 705 - Other - as specified
Due 6 May 2008
Resolved 6 May 2008
Resolution: New hose was added to portable bilge pump.
Lifesaving › Lifefloat › Serviceable
Issued 6 May 2008 Resolved
Make repairs to holes within the vessel's lifefloat or remove lifefloat.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 9 June 2008
Resolution: Lifefloat has been patched.
Engineering › Bilge Water Management System › Not Operational
Issued 6 May 2008 Resolved
Make high water alarm on the forward bilge pump operable.
Action required: 705 - Other - as specified
Due 6 May 2008
Resolved 6 May 2008
Resolution: Float switch was replaced.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 6 May 2008 Resolved
Company must establish a chemical testing program.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 9 June 2008
Resolution: Company has established a chemical testing program with APCA.
Documentation › Certificates/Documents › Stability Letter
Issued 6 May 2008 Resolved
Vessel used improper stability letter (M/V One Love). Provide proper stability letter.
Action required: 705 - Other - as specified
Due 6 May 2008
Resolved 6 May 2008
Resolution: Vessel has the proper stability letter (M/V Adventure)
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 May 2008 Resolved
Remove and replace expired aspirins.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 6 May 2008
Resolution: Expired aspirins were replaced.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 6 May 2008 Resolved
Replace batteries within inoperable flashlight.
Action required: 705 - Other - as specified
Due 6 May 2008
Resolved 6 May 2008
Resolution: Batteries were replaced, flashlight operable.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 February 2007 Resolved
Renew expired items in first aid kit.
Due 23 February 2007
Resolved 20 February 2007
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 15 February 2007 Resolved
Provide proof of FCC Marine Radio Operator's Permit for at least one person in crew.
Due 16 March 2007
Resolved 20 February 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 15 February 2007 Resolved
Service fixed fire extinguishing system located in fuel tank compartment space. Provide proof of the same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2007
Resolved 20 February 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 February 2007 Resolved
Provide 2 additional adult lifejackets. Until lifejackets are placed on board, vessel is restricted to carrying 24 total persons on board.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2007
Resolved 20 February 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 15 February 2007 Resolved
Repair bulb for magnetic compass. Until bulb is repaired, vessel is restricted to daylight operations only.
Due 23 February 2007
Resolved 20 February 2007
Communications › Radio Communications › EPIRB
Issued 15 February 2007 Resolved
Renew hydrostatic release. Renew EPIRB antennae.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2007
Resolved 20 February 2007
Documentation › Certificates/Documents › FCC SSL
Issued 12 April 2005 Resolved
PROVIDE VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE REFLECTING PROPER CALL SIGN.
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 20 April 2005
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 April 2005 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2005
Resolved 20 April 2005
Engineering › Fuel Oil Service System › Filter
Issued 12 April 2005 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND INSTALL HEAT DEFLECTOR SHIELD FOR EACH RACOR FUEL FILTER ASSEMBLY.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2005
Resolved 20 April 2005
Resolution: WITHDRAWN
Communications › Audible Communications › Horn/Whistle
Issued 12 April 2005 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE HORN ON BOARD VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2005
Resolved 20 April 2005
Lifesaving › Hand Flares
Issued 23 March 2004 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVIDE 3 ADDITIONAL DAY FLARES AND 3 ADDITIONAL NIGHT FLARES LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2004
Resolved 6 April 2004
Electrical › Lighting (emergency)
Issued 23 March 2004 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVIDE 1 ADDITIONAL HAND HELD FLASHLIGHT LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2004
Resolved 6 April 2004
Navigation › Collision/Grounding Avoidance
Issued 23 March 2004 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVIDE SOUND PRODUCING DEVICE
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2004
Resolved 6 April 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 23 March 2004 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, RENEW/RECHARGE FIRE EXTINGUISHER AT OPERATORS STATION. LEGACY COMPONENT DESC: Pressure
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2004
Resolved 6 April 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 23 March 2004 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVIDE SECURING TIE FOR FIXED GAS EXTINGUISHING SYSTEM ACTIVATING HANDLE. LEGACY COMPONENT DESC: Operating Controls
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2004
Resolved 6 April 2004
Pollution Prevention/Response › Prevention Equipment
Issued 23 March 2004 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, REPAIR/RENEW FWD COMPARTMENT BILGE ALARM. LEGACY COMPONENT DESC: Bilge Monitor
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2004
Resolved 6 April 2004
Lifesaving › Lifejacket/PFD (General)
Issued 23 March 2004 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, POSITION WHISTLES ON LIFEJACKETS SO THAT THEY MAY BE USED WHILE BEING WORN.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2004
Resolved 6 April 2004
Lifesaving › Buoyant Apparatus
Issued 23 March 2004 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, POSITION LIFEFLOAT WEAK LINK SO THAT IT WILL RELEASE CORRECTLY DURING AUTOMATIC OPERATION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2004
Resolved 6 April 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 15 January 2003 Resolved
PROVIDE EVIDENCE THAT FIXED FIRE EXTINGUISHING SYSTEM HAS BEEN SERVICED WITHIN THE PREVIOUS YEAR
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 January 2003
Resolved 30 January 2003
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 15 January 2003 Resolved
PROVIDE A SAFETY RADIO CERTIFICATE
Due 15 January 2003
Resolved 30 January 2003
Documentation › Logs/Records › Drug Test Records
Issued 15 January 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 15 January 2003
Resolved 30 January 2003
Lifesaving › Hand Flares › Quantity
Issued 15 January 2003 Resolved
PROVIDE 3 ADDITIONAL DAY, AND 3 ADDITIONAL NIGHT FLARES
Due 15 January 2003
Resolved 30 January 2003
Navigation › Piloting/Steering › Magnetic Compass
Issued 15 January 2003 Resolved
MAKE COMPASS LIGHT OPERATIONAL
Due 15 January 2003
Resolved 30 January 2003
Lifesaving › Buoyant Apparatus
Issued 15 January 2003 Resolved
RENEW/REPAIR LIFEFLOAT PAINTER CAN
Due 15 January 2003
Resolved 30 January 2003
Lifesaving › Buoyant Apparatus
Issued 15 January 2003 Resolved
STOW LIFEFLOAT AS TO INCORPORATE ONLY ONE WEAK LINK FOR AUTOMATIC RELEASING
Due 15 January 2003
Resolved 30 January 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 January 2003 Resolved
UPDATE FIRST AID KIT IAW 46 CFR 184.710
Due 15 January 2003
Resolved 30 January 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 15 January 2003 Resolved
MAKE FUME DETECTOR IN FUEL TANK COMPARTMENT OPERATIONAL
Due 15 January 2003
Resolved 30 January 2003
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 15 January 2003 Resolved
PROVIDE 2 PORTABLE EMERGENCY LIGHTS
Due 15 January 2003
Resolved 30 January 2003
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 15 January 2003 Resolved
PROVIDE 1 ADDITIONAL ADULT PFD
Due 15 January 2003
Resolved 30 January 2003
Communications › Radio Communications › EPIRB
Issued 11 December 2001 Resolved
Replace the hydrostatic release on the EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2001
Documentation
Issued 31 December 1999 Resolved
Provide a valid FCC Radio Safety Certificate.
Condition: Unknown
Due 31 December 1999
Resolved 31 December 1999

Ownership record