FLOYD J. LUPTON

FLOYD J. LUPTON is a 2000 passenger vessel (inspected). The Coast Guard has recorded 139 inspections since 2000, most recently in June 2026, along with 72 deficiencies and 18 casualty investigations between 2008 and 2026.

Records from 2000 to 2026. Most recent: inspection, 11 June 2026.

Built
2000
Last inspected
11 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ6289
507990
Flag
UNITED STATES
367432470
Maury page id
psix-507990

Inspections, by type

…with no type recorded20
Years with a record 26 calendar years (2000–2026)
The 139 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)167.7 ft × 44.0 ft × 10.5 ft
Registered tonnagegross 374 / net 289
ITC dimensions (L × B × D)167.7 ft × 44.0 ft × 10.5 ft
ITC tonnagegross 437 / net 148
BuilderMOSS POINT MARINE INC · ESCATAWPA MS, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMANNS HARBOR, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it374 - Regulatory (Subpart C or D), Gross Ton
437 - Convention (Subpart B), Gross Ton
289 - Regulatory (Subpart C or D), Net Ton
148 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ6289MMSI 367432470 · active · compulsorily equipped · granted 23 October 2019, expires 20 January 2030
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ALBEMARLE Towing Vessel · MISLE 149837 · 1 July 2012 · activity 4365035

Inspection history · 139

11 June 2026 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8400977
3 June 2026 Re-Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8385442
13 April 2026 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8347200
5 April 2026 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8343172
1 April 2026 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8340653
14 March 2026 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8326186
12 March 2026 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8322863
26 February 2026 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8316821
21 January 2026 Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8299249
21 January 2026 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8299618
13 January 2026 Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8295575
18 December 2025 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8285139
25 November 2025 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8274879
23 November 2025 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8272825
8 November 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8266580
18 September 2025 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8236582
29 July 2025 Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8197584
18 June 2025 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8161773
20 March 2025 COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8088673
31 January 2025 Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8063412
11 December 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8046223
3 December 2024 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8044187
20 September 2024 Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8017812
25 July 2024 Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7969749
1 July 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7947053
18 April 2024 MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7885796
8 November 2023 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7832271
21 September 2023 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7793832
2 September 2023 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7782878
6 July 2023 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7734404
12 June 2023 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7712805
11 June 2023 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7763309
7 May 2023 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7682993
23 March 2023 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7655432
14 December 2022 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7608920
20 October 2022 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7580992
30 September 2022 Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7569169
22 September 2022 MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7557136
1 September 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7548714
11 August 2022 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7530912
14 July 2022 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7503787
16 May 2022 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7452280
24 March 2022 Re-Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7417676
9 December 2021 Re-Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7365088
26 November 2021 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7358390
26 November 2021 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7358647
19 September 2021 MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7317594
16 September 2021 Deadweight Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7316682
19 May 2021 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7219671
9 February 2021 Deficiency Check · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7137803
1 January 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7119461
1 January 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7134013
9 October 2020 Deficiency Check · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7074613
11 September 2020 Damage Survey · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7055842
12 August 2020 Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7025376
22 October 2019 Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6839722
9 August 2019 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6778180
29 April 2019 Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6672496
20 December 2018 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6566403
9 November 2018 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6578134
10 October 2018 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6558664
9 October 2018 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6570613
27 September 2018 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6512562
8 June 2018 Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6437829
16 March 2018 Examination of Repairs · Hull Examination · Damage Survey · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6384268
26 February 2018 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6362542
21 February 2018 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6358523
14 December 2017 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6324026
14 September 2017 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6265043
27 July 2017 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6234061
29 June 2017 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6198289
8 June 2017 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6169483
5 May 2017 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6143230
28 March 2017 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6113738
28 March 2017 Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6123836
13 February 2017 Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6087590
21 December 2016 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6061790
19 September 2016 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6006089
20 June 2016 Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5910305
4 March 2016 MTSA Verification · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5827076
24 August 2015 Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5225409
20 July 2015 Construction Oversight · Internal Structural Exam · Examination of Repairs · Spot Check · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5190112
16 October 2014 Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5017529
1 October 2014 Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4996471
21 August 2014 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4977841
25 June 2014 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4905589
18 June 2014 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4891065
9 June 2014 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4901265
5 June 2014 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4899606
2 June 2014 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4877434
1 July 2012 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4365035
7 June 2012 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4336277
30 May 2012 Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4329959
16 September 2011 Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4145623
25 January 2011 Periodic Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3932416
22 December 2010 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3918273
12 December 2010 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3909824
8 December 2010 Periodic Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3906589
8 December 2010 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3908283
10 December 2009 MARPOL Annex I Examination · MTSA Verification · Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3638299
24 July 2009 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3544231
2 July 2009 Spot Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3521026
5 March 2009 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3431180
18 December 2008 Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3382168
9 September 2008 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3323428
11 June 2008 MTSA Verification · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3227428
3 February 2008 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3147688
1 February 2008 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3147645
24 January 2008 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3136006
21 June 2007 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2969159
22 March 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2892161
27 February 2007 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 2878628
25 October 2006 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2810592
2 May 2006 Excursion Permit
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 2693269
27 April 2006 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2634000
13 October 2005 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 2513511
12 October 2005 Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2513165
10 March 2005 COI Inspection · MTSA Verification · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2302916
23 February 2005 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2297778
15 November 2004 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2241274
1 September 2004 Periodic Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2184079
16 March 2004 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2040039
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961093
10 September 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1918466
18 March 2003 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1762162
31 October 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1699062
7 October 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1685952
2 October 2002 Periodic Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1688412
29 August 2002 Hull Examination · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1666516
21 May 2002 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1619030
20 March 2002 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1485055
30 August 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1420574
28 June 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1465666
22 March 2001 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1418868
11 January 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1450564
22 September 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1449376
30 June 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1403177
12 May 2000 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1049591
26 March 2000 Initial Certification · Initial Construction-Excluding Oversight · Inclining Experiment · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1369468

Deficiency record · 72

09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 June 2026 Resolved
A-End main engine exhaust piping lagging is not suitably insulated. Repair to satisfaction of the marine inspector. 46 CFR 72.03-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 18 June 2026
Resolution: Added new 6' wide strip of lagging all the way around exhaust pipe to completely cover pipe.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2026 Resolved
Light fixture protective cover found cracked and broken on fixture in B-End Voith space. Repair/replace to satisfaction of marine inspector. 46 CFR 111.75-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 18 June 2026
Resolution: Replaced light fixture protective cover with new. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 April 2026 Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery must be at least equivalent to the standards established by the ABS Marine Vessel Rules. Vessel operator reported that the vessel experienced a overspeed alarm on the B-main which resulted in a loss of propulsion. Effective repairs to the satisfaction of the Coast Guard, IAW manufacturer specifications.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2026
Resolved 6 April 2026
Resolution: Replaced with new engine speed switch.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 22 January 2026 Resolved
Nonmetallic flexible hoses installed in fluid powered systems must be in accordance with SAE J1942. The new hydraulic hose installed on the rescue boat davit does not indicate the correct type approval; provide proof of SAE J1942 type approval or replace the hoses with an approved type. 17FEB26 Note: Updated CG835 code to "705: Other" to reflect extension granted pending response from Coast Guard Type Approval Office regaurding the European-Manufactured (Indunorm EN 5832SN) hoses installed on approved Global Boat Davit GMBH System.
Action required: 705 - Other - as specified
Resolved 26 February 2026
Resolution: Installed hoses are part of the "Q" specification type approval and in accordance with the manufacturers original equipment installation.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 8 November 2025 Resolved
Each power-driven steering-gear system must be provided with at least one steering-gear control system. The "B"end number 2 steering system produces a bind alarm and presents with a clicking when actuated. Conduct analysis and repair to the satisfaction of a U.S. Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 8 November 2025
Resolved 10 November 2025
Resolution: Vessel replaced actuator and conducted sea trials.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 March 2025 Resolved
It shall be the duty of the master to see that all watertight doors in subdivision bulkheads that may be opened at sea, and all mechanisms remote controls, and indicators connected therewith, shall be periodically inspected at least once in each week that the vessel is navigated to the be assured that they are in proper operating condition. The watertight door on the weather deck leading to the engine room has an inoperable sensor.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2025
Resolved 24 March 2025
Resolution: MI witnessed operation of the new working sensor.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2025 Resolved
Each vessel must carry lifebuoys approved under approval series 160.150. Lifebuoy located outside the bridge was found to be heavily deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2025
Resolved 24 March 2025
Resolution: MI witnessed the installation of a new ring lifebuoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 December 2024 Resolved
A end voith unit overheated and shutdown.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2024
Resolved 16 December 2024
Resolution: A-end MDE Keel Cooler was found to have a failed drain plug causing coolant loss. Witnessed completion of repairs and operational test
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 September 2023 Resolved
At each annual inspection, the inspector must ensure that the following tests and inspections of fire detection and extinguishing equipment have been conducted: Fixed fire extinguishing systems must be checked as noted in table 71.25–20(a)(2). Annual service not conducted anticipating upcoming dry-dock. 705c-Upon completing upcoming dry-dock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 April 2024
Resolution: Annual servicing has been completed. Witnessed operational test of fixed systems; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 September 2023 Resolved
It shall be the duty of the owner, master, or person in charge to see that the vessel's firefighting equipment is at all times ready for use and that all such equipment required by the regulations in this subchapter is provided, maintained, and replaced as indicated. Found 03 CO2 portable extinguisher brackets on deck wasted. 705c-Upon completing upcoming dry-dock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 April 2024
Resolution: All weathered extinguisher brackets have been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 September 2023 Resolved
Tests and inspections of the lifesaving equipment shall be carried out during each inspection for renewal of certification and periodic inspection, and shall include, as applicable, a demonstration of— The proper condition of flotation equipment such as lifebuoys and associated equipment. B side waterlight for life ring buoy not flashing properly. 705c-Upon completing upcoming dry-dock
Action required: 705 - Other - as specified
Resolved 18 April 2024
Resolution: Conducted test of floating waterlights; all sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 September 2023 Resolved
Vessel must be equipped with dsc VHF radio. Properly integrate VHF radio with GPS and conduct proper radio check. 705c- Upon completing upcoming dry-dock
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 April 2024
Resolution: Inspected newly installed DSC capable radio; sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 September 2023 Resolved
At each annual inspection, the inspector shall conduct the following tests and inspections of hull equipment: (1) All subdivision bulkheads shall be examined to determine that their watertight integrity has not been impaired. Watertight doors in subdivision bulkheads have wrong type of gasket. 705c- Upon completing upcoming dry-dock
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 April 2024
Resolution: Inspected all watertight door gaskets and witnessed chaulk tests; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 May 2023 Resolved
46 CFR 58.01-35: Auxiliary Machinery vital to the main propulsion system must be provided in duplicate unless the system served is provided in independent duplicate, or otherwise provides continued or restored propulsion capability in the event of failure or malfunction of any single auxiliary component. Propulsion system showed error code on S2 B end, not allowing the operator to switch between S1 and S2. Restore system to working system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2023
Resolution: Component replaced and sea trials conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 September 2022 Resolved
A-End SSDG keel cooler supply and return hose replace due to cracking and deterioration. 46CFR70.20.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2022
Resolved 29 September 2022
Resolution: New hoses installed and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 September 2022 Resolved
Update PSTPs to correct MDS overspeed RPM setting and add over speed testing. 46CFR62
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2022
Resolved 20 October 2022
Resolution: Updated PSTPs submitted to MSC for review.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 September 2022 Resolved
Each machinery space must be ventilated to ensure that, when machinery or boilers are operated at full power in all weather including heavy weather, an adequate supply of air is maintained for the operation of the machinery. Vessel's representative reported that the emergency diesel generator has to operate with the emergency generator space's doors open to prevent the engine from overheating. Troubleshoot and provide adequate ventilation to prevent emergency generator from overheating IAW 46CFR112.05-5.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2022
Resolved 25 July 2024
Resolution: Observed EDG's ability to operate in high ambient temperatures with the space doors closed.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 September 2022 Resolved
The emergency power source must meet table 112.05-5(a)....Passenger vessels other than Ocean, Great Lakes, or coastwise and not on an international voyage must have a final emergency power source capable of operating for a minimum of 8 hours or twice the time of run, which ever is less. Vessel's representative reported the emergency generator overheats causing the engine to shutdown while under a load. Provide a final emergency power source capable of operating for a minimum of 8 hours or twice the time of run, which ever is less IAW 46CFR58.01-45.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2022
Resolved 25 July 2024
Resolution: Observed EDG's ability to operate in high ambient temperatures on two consecutive trips (Hatteras to Ocracoke and Ocracoke to Hatteras).
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 July 2022 Resolved
A end sound powered phone bell is inoperable. Repair/replace in accordance with 46CFR113.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 11 August 2022
Resolution: Phone tested SAT new bell installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2022 Resolved
Permanently mount AC unit and AC electrical panel in engine room in accordance with 46CFR58.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 11 August 2022
Resolution: Ac properly mounted along with electrical panel properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 November 2021 Resolved
Each self-propelled vessel and each mobile offshore drilling unit must have at least two electric generating sources; Vessel's #2 generator suffered a crack in the water cooled exhaust manifold.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 26 November 2021
Resolved 29 November 2021
Resolution: Crew replaced exhaust manifold.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2021 Resolved
B-end thrust actuator on the voith propulsion unit is excessively vibrating. Repair to the satisfaction of the attending CG Marine Inspector iaw 46 CFR 61.40-6.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 September 2021
Resolution: NCDOT shipyard personnel tightened thrust actuator mount.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 September 2021 Resolved
Bilge dewatering control valve for B-end has suction gauge that is inoperable. Gauge is used in normal operation to indicate vaccum, prime, and suction. Repair or replace to the satisfaction of the attending CG Marine Inspector iaw 46 CFR 56.50-50.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 September 2021
Resolution: New suction gauges installed and tested on A-end and B-end
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 23 September 2021 Resolved
Sound powered phone in the B-end Voith Compartment is not loud enough to properly hear and communicate. Repair or replace to the satisfaction of the attending CG Marine Inspector iaw 46 CFR 58.25-15
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 September 2021
Resolution: New sound powered phone provided and tested SAT.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 September 2021 Resolved
Emergency lighting on main deck por side is not installed and/or inoperable. Repair/install new or provide evidence that e-lighting is not required on port side iaw 46 CFR 112.15-1(f).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 December 2021
Resolution: Spoke w/ Vessel Master and determined flood light switches in pilot house to be mislabled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 February 2021 Resolved
B-end MDE emrgency shut down (low oil), prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2021
Resolution: The MDE L/O shutdown was adjusted and tested satisfactory by the NCDOT electrician.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2021 Resolved
#1 SSDG low lube oil shut down not operational. Prove proper operation
Action required: 10 - Deficiency Rectified
Resolved 10 February 2021
Resolution: Proved proper operation of the L/O shutdown on the SSDG
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 10 February 2021 Resolved
Prove merchant mariner credential for engineer. Not onboard
Action required: 705 - Other - as specified
Due 10 February 2021
Resolved 10 February 2021
Resolution: DDE picked up his MMC and presented to the USCG prior to leaving the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 10 February 2021 Resolved
B-end cargo net attachment points worn out. Crop and renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2021
Resolved 17 August 2021
Resolution: New attachments installed while in dry-dock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 February 2021 Resolved
A-end re-mark/properly mark escape hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2021
Resolved 23 September 2021
Resolution: New markings were on all hatches deck hatches.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 February 2021 Resolved
B-end engine room vent not closing 100%. Adjust and prove proper operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2021
Resolved 16 February 2021
Resolution: Maintenance crew made adjustments and will properly close.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 10 February 2021 Resolved
Remove oil from bilges under #2 SSDG.
Action required: 705 - Other - as specified
Resolved 12 February 2021
Resolution: Vessel maintenance removed the oil from the bilges.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 January 2021 Resolved
Complete permanent repair to throttle air controls/ air compressor prior to carring passengers. Once repairs are completed and tested, provide a technicians report and a signed captians attestation of repair and operational test to CG [name withheld].
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 January 2021
Resolution: New check valve installed on air supply compressor air line.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 November 2020 Resolved
Temperature gauge on B end voith is damaged/inoperative.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 November 2020
Resolved 20 November 2020
Resolution: Temperature gauge was replaced and installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 November 2020 Resolved
B fwd (stbd) sound power phone hardware is damaged/missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2020
Resolved 20 November 2020
Resolution: Installed hardware on the sound power phone.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 November 2020 Resolved
B end pilothouse horn handle had loose hardware.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 November 2020
Resolved 4 November 2020
Resolution: Tightened the hardware on the horn handle.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 September 2020 Resolved
During routine testing, the No. 2 generator would not properly maintain electrical load. Make effective repairs and prove proper operation to the attending Marine Inspector. Vessel is restricted from carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2020
Resolution: New #2 gen set installed after unapproved temp repairs failed. MI inspected new install and full load test, ALL SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 12 August 2020 Resolved
A and b end nets replace with new due deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2020
Resolved 25 August 2020
Resolution: A and B end nets were properly renewed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 12 August 2020 Resolved
Deck hatch security marks needs to be painted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 August 2020
Resolved 18 August 2020
Resolution: security marks properly painted.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 August 2020 Resolved
Bridge and engine room first aid kits expired/missing meds
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2020
Resolved 25 August 2020
Resolution: First aid kits were replaced.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 August 2020 Resolved
B end radio antenna bracket broken. Crop and renew.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2020
Resolved 25 August 2020
Resolution: Antenna brackets were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 August 2020 Resolved
B end child life jacket storage box damaged. Top hinge broken and exposed fiberglass.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2020
Resolved 25 August 2020
Resolution: Deck box lid was properly repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 August 2020 Resolved
Rescue boat release hook cotter pin. Wasted replace with new.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 August 2020
Resolution: Release hook cotter pin was renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 12 August 2020 Resolved
B end bilge suction not operating
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 12 August 2020
Resolution: Witnessed satisfactory bilge suction on the 1b void.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2020 Resolved
CO2 Portable #16 tank room, @ FR 25B, cracked hose
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 August 2020
Resolution: Cracked hose was replaced in kind.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 August 2020 Resolved
B end frame #12 stuffing box over WTD missing packing not watertight.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 August 2020
Resolved 18 August 2020
Resolution: Properly made stuffing box watertight.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 August 2020 Resolved
Fixed CO2 stop valve leaking during the test.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 12 August 2020
Resolution: Stop valve was tightened up and retested; all sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 August 2020 Resolved
WTD frame 28B door seal is not water tight, 1/2" gap at the top of the door.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 12 August 2020
Resolution: Filled in the 1/2" gap with gasket material and made the door watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 August 2020 Resolved
Rescue boat aft line needs quick release installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2020
Resolved 18 August 2020
Resolution: New quick release was properly installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2020 Resolved
Portable ext #17 engine room hose cracked
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2020
Resolved 3 September 2020
Resolution: The hose was properly replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 August 2019 Resolved
An indicator light for the #1 watertight door is malfunctioning. Door is watertight but is indicating open from the bridge while door is closed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2019
Resolved 27 August 2019
Resolution: Watertight door indicator now operational.
Electrical › Electric Supply System (service) › Battery Charger
Issued 26 February 2018 Resolved
Found the propulsion control system 2 battery charger faulty and both batteries dead. Replace the charger and both batteries.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2018
Resolution: Inspected installation of new battery charger and batteries; all sat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 June 2017 Resolved
Found a leak in the A/C cooling water overboard discharge pipe at the flow meter. During discussion/ research a comment, dated 11/28/2016, was found on file stating that repairs had been made using putty but it still leaked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 27 July 2017
Resolution: Flow meter was replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 May 2017 Resolved
Wire connection was loose and casued shipboard electrical failure. Repair loose wire connection to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 5 May 2017
Resolution: Loose connection was replaced with a tightly crimped replacement connection.
Fire Fighting › Fire Main › Condition
Issued 2 June 2014 Resolved
Repair/replace hole found in fire main as original and test as required by 46 CFR 56.97-40(a)(7) once complete to ensure there are no other areas of concern.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2014
Resolution: System was hydro tested to at least 150psi with no leaks noticed as required. System appears to be satisfactory.
Lifesaving › Inflatable Liferafts › Float Free
Issued 7 June 2012 Resolved
Life rafts must be kept in a float free arrangement.
Action required: 705 - Other - as specified
Due 7 July 2012
Resolved 8 June 2012
Resolution: Inspector visually verified proper arrangement
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 7 June 2012 Resolved
Davit cable for the rescue boat must be replaced or proof of replacement be provided.
Action required: 705 - Other - as specified
Due 7 July 2012
Resolved 7 September 2012
Resolution: Attending inspectors verified operation of rescue boat davit/cable assembly during inspection.
Operations/Management › Drills/Instruction › Fire
Issued 7 June 2012 Resolved
Vessel must conduct a fire and man over board drill in the presence of a Marine Inspector
Action required: 705 - Other - as specified
Due 7 July 2012
Resolved 6 September 2012
Resolution: Attending inspectors witnessed required drills with vessels crew.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 7 June 2012 Resolved
Communication for A&B end steering system does not communicate as desinged, repair communication link orchange design & submit for approval.
Action required: 705 - Other - as specified
Due 7 July 2012
Resolved 7 September 2012
Resolution: Attending inspectors verified operation of portable communications devices (Peltor''s) at each steering station. Unit''s are kept in Engineers [name withheld] (ECC).
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 June 2012 Resolved
Provide approved QFA analysis for new steering system.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 8 June 2012
Resolution: Inspector RCVD a copy of the approved QFA
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 June 2012 Resolved
Provide approved PSTP with current revisions for new steering system.
Action required: 705 - Other - as specified
Due 7 July 2012
Resolved 7 September 2012
Resolution: MSD Fort Macon received approved DVT''s & PSTP''s. See MSC letter dated 07AUG2012.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 June 2012 Resolved
Passenger count is reduced to 296 until 04 new life jackets are provided
Action required: 705 - Other - as specified
Due 7 July 2012
Resolved 8 June 2012
Resolution: Inspector saw new life jackets
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 7 June 2012 Resolved
demonstrate proper operation of steering system without alarms
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2012
Resolution: Attending inspectors performed static and operational test of each proplusion control unit/pod in the presence of vessels crew and manufacturers technical representative upon installing new actuators on each propulsion unit/pod.
Operations/Management › Vessel Safety Management › Designated Person(s)
Issued 16 September 2011 Resolved
Designate senior AB in writing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2011
Resolution: Senior AB designated in writing.
Navigation › Piloting/Steering › Magnetic Compass
Issued 16 September 2011 Resolved
Provide equivalency letter to use digital compass in lieu of magnetic compass.
Action required: 705 - Other - as specified
Due 16 October 2011
Resolved 7 October 2011
Resolution: Entered in error. Vessel is not "ocean-going" and therefore is not required to have a compass.
Fire Fighting › Ventilation Systems › Ducts
Issued 16 September 2011 Resolved
Demonstrate proper operation of all emergency engine room ventilation shut downs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2011
Resolution: Proper operation of all emergency engine room ventilation shut downs demonstrated.
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 September 2011 Resolved
Label emergency F.O. shut off valves with direction of closure.
Action required: 705 - Other - as specified
Due 16 October 2011
Resolved 4 October 2011
Resolution: Marked F.O. shut off valves with emergency label with direction of closure.
Lifesaving › Launching Appliances › Davit
Issued 16 September 2011 Resolved
Label rescue boat davit with cable change out date.
Action required: 705 - Other - as specified
Due 16 October 2011
Resolved 6 October 2011
Resolution: Rescue boat davit labeled.
Lifesaving › Inflatable Liferafts › Servicing
Issued 27 February 2007 Resolved
L/R expiration date is 28 Feb 07. Replacement L/R's are scheduled to arrive Mar 09, 2007. Issued a two week extension on expiration of L/R servicing.
Action required: 705 - Other - as specified
Due 17 March 2007
Resolved 8 May 2007
Resolution: Life rafts serviced
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 27 April 2006 Resolved
Vessel needs to restencil lifejacket storage box on bridge deck with quantity and size of lifejackets stored. 46 CFR 180.78.
Condition: Improper/Lack of Maintenance
Due 27 May 2006
Resolved 27 April 2006
Resolution: Vessel restencil lifejacket storage box on bridge.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 27 April 2006 Resolved
Bowline cleat for rescue boat needs to be moved further away from the lauching area to provide better support for the rescue boat.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 7 June 2007
Resolution: Corrected.
Fire Fighting
Issued 26 March 2000 Resolved
Demonstrate proficiency of crew drills prior to placing vessel into intended service.
Condition: Unknown
Due 26 March 2000
Resolved 26 March 2000

Casualty record · 18

1 February 2008Routine · role: Involved in a Marine Casualty · activity 3147645
3 February 2008Routine · role: Involved in a Marine Casualty · activity 3147688
4 October 2009Routine · role: Involved in a Marine Casualty · activity 3609869
8 December 2010Routine · role: Involved in a Marine Casualty · activity 3908283
12 December 2010Routine · role: Involved in a Marine Casualty · activity 3909824
22 December 2010Routine · role: Involved in a Marine Casualty · activity 3918273
6 March 2011Routine · role: Involved in a Marine Casualty · activity 3959069
5 October 2011Routine · role: Involved in a Marine Casualty · activity 4161382
1 July 2012Routine · role: Involved in a Marine Casualty · activity 4365035
6 February 2013Routine · role: Involved in a Marine Casualty · activity 4532519
24 March 2013Routine · role: Involved in a Marine Casualty · activity 4556957
8 July 2013Routine · role: Involved in a Marine Casualty · activity 4807163
9 October 2018Routine · role: Involved in a Marine Casualty · activity 6570613
9 November 2018Routine · role: Involved in a Marine Casualty · activity 6578134
1 January 2021Routine · role: Involved in a Marine Casualty · activity 7134013
26 November 2021Routine · role: Involved in a Marine Casualty · activity 7358647
11 June 2023Routine · role: Involved in a Marine Casualty · activity 7763309
21 January 2026Routine · role: Involved in a Marine Casualty · activity 8299618
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.