Records from 1999 to 2011. Most recent: inspection, 15 July 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
15 July 2011
DAPI Audit · COI Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4093997
8 November 2010
In-Service Inspection · Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3801696
8 November 2010
Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 3896412
2 January 2009
Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3393844
11 October 2007
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3077424
18 January 2007
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2858130
7 September 2005
Annual Inspection · Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2569352
30 August 2005
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2479634
29 November 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2281626
15 January 2004
Hull Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1984572
18 October 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1492878
26 February 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1436518
5 December 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 816526
26 November 1999
Plan Review "T" Boat · Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1361292
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 20 July 2010
Resolved
Dive ladder is loose at the deck connection. Tighten ladder to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2010
Resolution: Owner replaced nuts with locking nuts and washers.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 July 2010
Resolved
Stern light inoperable. Prove proper operation of stern light to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2010
Resolution: Owner proved proper operation of stern light.
Engineering › Gasoline Engine (propulsion) › Spark Plug (4 cycle)
Issued 20 July 2010
Resolved
Vessel's outboard engine failed to operate in "fwd", it would only operate in "reverse". It was also observed that the engine was only operating with two cylinders due to a disconnected spark plug. Prove proper operation of the vessel's outboard engine to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2010
Resolution: Owner provided a receipt/work order attesting to proper repair and operation of outboard engine.
Engineering › Fuel Oil Service System › Hose
Issued 20 July 2010
Resolved
01 fuel hose leading from fuel tank to fuel filter is dry and not of an approved type. Replace 01 fuel hose with SAE J-1942 or Coast Guard approved fuel hose to the satisfaction of the attending marine inspector. (USCG type A1, A2, B1, or B2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2010
Resolution: Owner replaced 02 fuel hoses.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 January 2006
Resolved
Demonstrate proper operation of waterlight prior to operation after dusk.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Properly operating waterlight was placed on vsl.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 19 January 2006
Resolved
Provide proper clip for fire extinguisher mounting bracket.
Due 19 January 2006
Resolved 19 January 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 19 January 2006
Resolved
Renew retroreflective tap on lifepreservers as necessary.
Due 19 January 2006
Resolved 19 January 2006
Accommodation/Occupational Safety
Issued 26 November 1999
Resolved
ADD A SAFETY CHAIN TO RESTRICT PASSENGER ACCESS TO THE BOW WHILE THE VESSELIS MAKING WAY.
Condition: Unknown
Due 26 November 1999
Resolved 26 November 1999
Documentation
Issued 26 November 1999
Resolved
PROVIDE PROOF OF ENROLLMENT IN A DRUG CONSORTIUM OR ACCEPTABLE DRUG TESTINGPROGRAM.
Condition: Unknown
Due 26 November 1999
Resolved 26 November 1999
Engineering
Issued 26 November 1999
Resolved
PROVIDE PROOF THAT THE FUEL TANK MEETS AN ACCEPTABLE CONSTRUCTION STANDARD.
Condition: Unknown
Due 26 November 1999
Resolved 26 November 1999
Fire Fighting
Issued 26 November 1999
Resolved
PROVIDE A B-II FIRE EXTINGUISHER. THE VESSEL HAS A B-I DATED 1999, BUT NEEDS A B-II.
Condition: Unknown
Due 26 November 1999
Resolved 26 November 1999