TEEWINOT

TEEWINOT is a 1980 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2002, most recently in May 2026, along with 61 deficiencies.

Records from 2002 to 2026. Most recent: inspection, 27 May 2026.

Built
1980
Last inspected
27 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

508032
Flag
UNITED STATES
—
Maury page id
psix-508032

Inspections, by type

Years with a record 20 calendar years (2002–2026)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.6 ft × 13.2 ft × 6.4 ft
Registered tonnagegross 22 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLACIER PARK BOAT BUILDERS · KALISPELL, MT, UNITED STATES · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMORAN, WY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Gross Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

27 May 2026 DAPI Audit · Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8319441
28 May 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8106646
29 May 2024 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7922801
30 May 2023 Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7684667
12 May 2022 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7449201
9 April 2021 Administrative Inspection · Deficiency Check · Hull Examination · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7172116
8 October 2020 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7073792
3 August 2020 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7023587
7 June 2019 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6690451
7 June 2018 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check · MARPOL Annex VI Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6429944
8 July 2017 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6211891
7 June 2017 MARPOL Annex VI Survey · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6142990
16 May 2016 Deficiency Check · Administrative Inspection · DAPI Audit · Special · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5878659
6 August 2014 Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4946150
9 June 2014 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4874164
25 June 2012 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4358378
10 May 2012 COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4307552
20 July 2009 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3540487
13 May 2009 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3473972
21 November 2008 Drydock Extension
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3367329
22 May 2008 Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3213787
4 June 2007 COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2951149
1 June 2005 Re-Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2375819
3 June 2004 Annual Inspection · Hull Examination
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2092538
4 June 2003 Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1816413
16 July 2002 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1639271

Deficiency record · 61

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 June 2019 Resolved
Ensure the leaking stbd MDE aft impeller pump raw water hose is replaced. (hose has been temporarily repaired)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 3 July 2019
Resolution: A new two piece hose was installed due to the unavailability of a one piece OEM hose.
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 7 June 2018 Resolved
Clean the stbd MDE air filter and determine the cause of the excessive oil accumulation. Repair as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2018
Resolved 29 June 2018
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 7 June 2018 Resolved
Properly install the new SOS rescue sling and ensure the crew is properly trained on how to deploy the new system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2018
Resolved 29 June 2018
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 June 2017 Resolved
Conduct dockside training with realistic weights to ensure that the crew knows how to operate the life sling davit.
Due 7 July 2017
Resolved 13 July 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 June 2017 Resolved
Ensure the vessel’s emergency procedures reflect now the vessel will actually respond to an emergency and that the drills are conducted as per those procedures.
Due 7 July 2017
Resolved 13 July 2017
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 7 June 2017 Resolved
Manufacture and install a new saddle bracket for the vessel’s life raft to ensure the weight of the life raft is more dispersed to prevent cracking of the fiberglass cabin top.
Action required: 705 - Other - as specified
Due 7 June 2018
Resolved 7 June 2018
Resolution: complete
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2016 Resolved
Ensure the first aid kit has the proper contents and that the items are not expired.
Condition: Improper/Lack of Maintenance
Due 30 June 2016
Resolved 29 June 2016
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 31 May 2016 Resolved
Tighten the port engine throttle cable retaining bracket.
Condition: Improper/Lack of Maintenance
Due 30 June 2016
Resolved 31 May 2016
Engineering › Steering Gear System › Bracket/Clamp
Issued 31 May 2016 Resolved
Tighten the steering ram bracket.
Condition: Improper/Lack of Maintenance
Due 30 June 2016
Resolved 31 May 2016
Construction/Loadline › Structures › Superstructure
Issued 30 May 2016 Resolved
Prior to operating the vessel in 2017, open up the gel coat fracture in the cabin top, stbd side, in vicinity of the life raft, so the internal framing can dry out. Once the framing is dry, repair as necessary. Ensure a fire retardant resin is used and that the Peoria Coast Guard is involved in the repair proposal.
Condition: Design Flaw
Due 22 May 2017
Resolved 7 June 2017
Construction/Loadline › Hull › Side Shell
Issued 30 May 2016 Resolved
Prior to operating the vessel in 2017, repair the two gouges, stbd side, exterior, amidships area, approximately 12 “above the waterline.
Condition: Damaged By Earlier Event
Due 22 May 2017
Resolved 7 June 2017
Engineering › Freshwater System (jacketwater cooling) › Suction Strainer
Issued 30 May 2016 Resolved
Tighten the stbd sea chest raw water strainer.
Condition: Improper/Lack of Maintenance
Due 30 June 2016
Resolved 31 May 2016
Fire Fighting › Ventilation Systems › Operating Controls
Issued 9 June 2014 Resolved
Prove proper operation of the stbd aft vent closure.
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 6 August 2014
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 9 June 2014 Resolved
Replace raw water hose on port MDE.
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 6 August 2014
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 June 2014 Resolved
Repair starboard side main cabin entrance railing.
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 6 August 2014
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 9 June 2014 Resolved
Remove four (4) condemned child life jackets from the vessel.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 9 June 2014
Resolution: Jackets removed and destroyed.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 9 June 2014 Resolved
Conduct and document survival craft weekly & monthly maintenance/inspections as required by 46 CFR 185.720 & 722 (weekly visuals & monthly as per manufactures instructions).
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 6 August 2014
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 June 2012 Resolved
Install a mounting bracket for the accommodation space, B-II, portable fire extinguisher. Do to space limitations, the extinguisher may be mounted in the forward cabin void providing a sign (fire extinguisher inside) is posted on the door.
Due 14 July 2012
Resolved 24 July 2012
Documentation › Markings/Placards › Official Number (US)
Issued 10 May 2012 Resolved
Ensure the vessel's hailing port is displayed on the vessel's stern and the official number is permanently affixed to an internal structural member. Items were already on order.
Due 27 June 2012
Resolved 25 June 2012
Communications › Radio Communications › VHF Radiotelephone
Issued 10 May 2012 Resolved
Ensure the vessel master has an FCC restricted radio operators permit.
Due 27 June 2012
Resolved 25 June 2012
Documentation › Certificates/Documents › Stability Letter
Issued 10 May 2012 Resolved
Post the vessel's new stability letter. USCG will provide a replacement letter.
Due 27 June 2012
Resolved 25 June 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 May 2012 Resolved
Ensure the first aid kit meets the requirements of 33CFR160-041. Item was already on order.
Due 27 June 2012
Resolved 25 June 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2012 Resolved
Repair or replace the missing forward window fan guard located at the operator's station.
Due 27 June 2012
Resolved 25 June 2012
Lifesaving › Lifefloat › Serviceable
Issued 10 May 2012 Resolved
Replace the vessel's life ring. Ring was onboard but starting to show signs of deterioration.
Due 27 June 2012
Resolved 25 June 2012
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 10 May 2012 Resolved
Ensure the company has negative pre employment test results before placing the crew in safety sensitive positions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2012
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 13 May 2009 Resolved
Properly repair the leaking fuel tank, capacity sensor. Remove all residue oil from the bilge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2009
Fire Fighting › Ventilation Systems › Ducts
Issued 13 May 2009 Resolved
Stern engineroom vent closures are not operating properly and the vents can't be secured in case of a fire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2009
Resolved 4 June 2009
Engineering › Bilge Water Management System › Pump
Issued 13 May 2009 Resolved
Prove proper operation of the cabin void bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 May 2009 Resolved
Prior to operating the vessel at night or in reduced visibility, replace the life ring float light battery
Condition: Placed in Improper Service
Due 1 September 2009
Resolved 2 June 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 May 2009 Resolved
Prove proper operation of the vessel’s anchor light. Properly wire and install the vessel’s anchor light.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 2 June 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 May 2009 Resolved
Properly install the search light armored cable and seal the fracture in the search light base plate cover.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 2 June 2010
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 13 May 2009 Resolved
Properly install and support the fuel tank vent line in fore peak and cabin void. (Use metal bands; no plastic bands).
Condition: Placed in Improper Service
Due 1 September 2009
Resolved 2 June 2010
Engineering › Bilge Water Management System › Pump
Issued 13 May 2009 Resolved
Replace the damage engine room bilge pump. Ensure the new pump is U/L approved.
Condition: Unknown
Due 10 July 2009
Resolved 2 June 2010
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 13 May 2009 Resolved
Remove the non-approved cushion foam from beneath the aft bench seat and install CG approved insulation material to isolate the wooden bench seat at the stern of the engine room.
Condition: Placed in Improper Service
Due 1 September 2009
Resolved 2 June 2010
Engineering › Feedwater/Condensate Water System › Piping
Issued 13 May 2009 Resolved
Remove the abandoned rubber heater waterline where they penetrate the engine room forward bulkhead.
Condition: Unknown
Due 1 September 2009
Resolved 2 June 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 May 2009 Resolved
Proper hang the cabin void bilge wires with metal supports where the plastic supports have broken.
Condition: Placed in Improper Service
Due 1 September 2009
Resolved 2 June 2010
Communications › Public Address System › Loudspeaker
Issued 13 May 2009 Resolved
Properly install the P/A system control box wires (currently plastic wire twisted) at the operator station.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 2 June 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 May 2009 Resolved
Ensure first aid kit includes instructions.
Condition: Improper/Lack of Maintenance
Due 1 September 2009
Resolved 2 June 2010
Fire Fighting › Combustible Materials › Draught Stops
Issued 13 May 2009 Resolved
Remove the house hold type foam insulation and install (Fire Stop) or equivalent material in the holes in the forward engine room bulkhead.
Condition: Placed in Improper Service
Due 1 September 2009
Resolved 2 June 2010
Navigation › Piloting/Steering › Magnetic Compass
Issued 13 May 2009 Resolved
Install a marine compass.
Condition: Unknown
Due 1 September 2009
Resolved 2 June 2010
Fire Fighting › Ventilation Systems › Ducts
Issued 13 May 2009 Resolved
Ensure the Port side supply vent requires a non-combustible fixed closure device.
Condition: Unknown
Due 10 July 2009
Resolved 2 June 2010
Navigation › Piloting/Steering › Marine Charts
Issued 13 May 2009 Resolved
Ensure chart of lake on each vessel.
Condition: Improper Installation
Due 1 September 2009
Resolved 2 June 2010
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 13 May 2009 Resolved
Remove residue fuel puddle under fuel tank.
Due 4 July 2009
Resolved 4 June 2009
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 May 2009 Resolved
Update emergency procedures to include throwing of a buoyant object immediately upon man over board.
Condition: Placed in Improper Service
Due 1 September 2009
Resolved 2 June 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 May 2009 Resolved
Port side rear seat, inboard mount is loose.
Condition: Improper/Lack of Maintenance
Due 4 June 2009
Resolved 4 June 2009
Documentation › Certificates/Documents › Stability Letter
Issued 13 May 2009 Resolved
Post Stability Letter & COI
Condition: Unknown
Due 4 June 2009
Resolved 4 June 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 May 2009 Resolved
Make the stern light wiring thru hull watertight.
Condition: Improper/Lack of Maintenance
Due 4 June 2009
Resolved 4 June 2009
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 May 2009 Resolved
Place on board 2 flashlights, one near the engine room and one near the operator's station.
Condition: Improper/Lack of Maintenance
Due 4 June 2009
Resolved 4 June 2009
Lifesaving › Inflatable Liferafts › Markings
Issued 13 May 2009 Resolved
Install the vessel name on life raft shell & on life ring (requires re-stenciling).
Condition: Placed in Improper Service
Due 4 June 2009
Resolved 4 June 2009
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 13 May 2009 Resolved
Post instructions for donning child size PFDs.
Condition: Unknown
Due 4 June 2009
Resolved 4 June 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 13 May 2009 Resolved
Verify fixed firefighting agent capacity is 200 cubic feet or greater.
Condition: Unknown
Due 4 June 2009
Resolved 4 June 2009
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 22 May 2008 Resolved
Amend Company Drug and Alcohol program to seperate requirements for marine crew in regards to preemplyment testing and post casulty testing.
Condition: Unknown
Due 6 July 2008
Resolved 21 June 2008
Resolution: Resolved.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 May 2008 Resolved
Provide CG approved life bouy waterlight. Daylight operations only until complied with.
Action required: 705 - Other - as specified
Due 4 June 2009
Resolved 4 June 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 May 2008 Resolved
Replace 50 foot lofe line with 60 foot iaw with CG requirements.
Due 6 July 2008
Resolved 4 June 2009
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 3 June 2004 Resolved
Both cutlass bearings must be replaced and both motors need re-allignment to within tolerance. LEGACY COMPONENT DESC: Stern Tube Bearing
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2006
Resolved 14 June 2006
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 June 2004 Resolved
Fiberglass exhaust piping on stern to be replaced due to heat and wear. LEGACY COMPONENT DESC: Pipe Flange
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2006
Resolved 5 June 2006
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 3 June 2004 Resolved
Relocate circuit breaker next to battery to shorten length and prevent accidental shorting. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper Installation
Due 3 June 2006
Resolved 12 June 2006
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 3 June 2004 Resolved
Service fixed halon fire extinguishing system prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2006
Resolved 12 June 2006
Engineering › Fuel Oil Service System › Piping
Issued 3 June 2004 Resolved
Fuel line on stbd engine exceeds 30 inches, replace section with rigid piping.
Condition: Improper Installation
Due 3 June 2006
Resolved 28 June 2006
Construction/Loadline › Hull › Side Shell
Issued 3 June 2004 Resolved
Make permanent repairs to temporary patch on port side of hull at waterline approx. 15 feet from bow. Make permanent repairs also to stiffeners at the same area.
Condition: Damaged By Earlier Event
Due 3 June 2006
Resolved 12 June 2007
Construction/Loadline › Hull › Hull Plating
Issued 3 June 2004 Resolved
Repair hull under fuel tank where hull has blistered and stain has shown on hull.
Condition: Design Flaw
Due 3 June 2006
Resolved 3 July 2006

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.