Records from 2006 to 2025. Most recent: inspection, 4 November 2025.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 24.0 ft × 10.0 ft
Registered tonnagegross 96 / net 77
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDOUGLAS J CHIASSON SR · LAROSE, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPASS CHRISTIAN, MS
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Simplified, Gross Ton
77 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
4 November 2025
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8245389
7 August 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8204772
24 October 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8024080
16 January 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7849653
28 November 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7600881
27 January 2022
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7387093
23 August 2020
Examination of Repairs · Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7041010
2 December 2019
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 6905830
30 March 2017
Industry Initiated Exam · MARPOL · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6115395
24 November 2014
MARPOL · Industry Initiated Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5029369
23 June 2013
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4828161
27 January 2010
MARPOL · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3673958
5 February 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3415331
8 December 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3128871
29 August 2006
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2771085
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2025
Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section. Vessels 02 fire hoses were found to be severely leaking from there connection points.
46CFR142.235
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2025
Resolution: Received video evidence of new fire hoses installed and operating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 4 November 2025
Resolved
The following systems must be equipped with gauges at the machinery location. Auxiliary generator engine lubricating oil pressure and auxiliary generator
engine RPM. Vessels port generator tachometer was not working.
46 CFR 143.230
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2025
Resolved 5 November 2025
Resolution: Received video evidence of the generator tachometer(RPM)gauge working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 November 2025
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Vessels stbd side lifebouy waterlight near the operating station failed to operate and did not have the proper battery in it.
46 CFR 141.230
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2025
Resolved 12 November 2025
Resolution: Received evidence of new battery and light operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 January 2024
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be
fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Fuel shutoff valve failed to operate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2024
Resolved 17 January 2024
Resolution: Crew replaced valve and conducted a satisfactory test of the new valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 January 2024
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify
that the system or equipment functions as designed.
During today’s inspection we were not a able to conduct a test of the vessels bilge suction system. Vessel is required to conduct a test of the vessels bilge system in the presence of a marine inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2024
Resolved 17 January 2024
Resolution: Crew was able to conduct a satisfactory test of the bilge system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 January 2024
Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with
the inspection, maintenance procedures. Vessels fire extinguisher in the engine room was found not properly secured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 17 January 2024
Resolution: Crew mounted extinguisher.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 January 2024
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Vessel had 02 motor controllers with no label for the equipment it serves.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 17 January 2024
Resolution: Crew labeled all motor controllers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 January 2022
Resolved
Vessels 160B was not permenantly mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2022
Resolved 1 February 2022
Resolution: Vessel rep. from TBS sent is satisfactory evidence of deficiency correction.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 January 2022
Resolved
Vessel had a 3/4" hole in the port side superstructure, main deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2022
Resolved 1 February 2022
Resolution: Vessel rep. from TBS sent is satisfactory evidence of deficiency correction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2020
Resolved
Vessel did not have a 40:BC fire ectinguisher located near the paint locker.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2020
Resolved 23 November 2020
Resolution: Vessel sent in satisfactory evidence of deficiency correction. Vessel purchased and mounted a 40:BC fire extinguisher outside paint locker.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 November 2020
Resolved
Vessel had multiple fuel leaks on both main diesel engines.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2020
Resolved 23 November 2020
Resolution: Vessel sent in satisfactory evidence of deficiency correction. Vessel surveyor sent in video of new fittings installed with no apparent leaks.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 November 2020
Resolved
Vessel did not have flame screens on any of the fuel vent pipes.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2020
Resolved 23 November 2020
Resolution: Vessel sent in satisfactory evidence of deficiency correction. Vessel surveyor sent in pictures of new bell housings with flame screens installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2020
Resolved
Vessel did not have spanner wrenches located at the fire stations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2020
Resolved 30 November 2020
Resolution: Vessel installed spanner wrenches at all the fire stations.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 November 2020
Resolved
Vessels paint locker had severe wastage on the vent pipes and door.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2020
Resolved 30 November 2020
Resolution: Vessel replaced both wasted vents and repaired the door of the paint locker.