MAURY USCG vessel records
← All vessels

AO B 206

AO B 206 is a 1951 tank barge. The Coast Guard has recorded 87 inspections since 1984, most recently in July 2017, along with 15 deficiencies.

Records from 1984 to 2017. Most recent: inspection, 3 July 2017.

Built
1951
Last inspected
3 July 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 3 July 2017
…with no type recorded37
Operational controls None recorded without a removal date
Years with a record 26 calendar years (1984–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-50817

Documentation record

Tonnage as PSIX records it1370 - Regulatory (Subpart C or D), Net Ton
1370 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 87

3 July 2017 Uninspected Other
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6212082
30 June 2017 Uninspected Other
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6201346
10 September 2008 Periodic Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3322331
18 December 2007 Damage Survey
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3118544
13 August 2007 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3027720
26 October 2006 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2808633
25 September 2006 Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2786497
7 April 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2619430
14 October 2005 Internal Structural Exam · Hull Examination · Cargo Tank Internal · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2514342
4 August 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2450965
25 March 2005 MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2319239
25 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2319445
10 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2238519
29 July 2004 Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2149273
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1983837
13 December 2003 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1963738
3 September 2003 Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1896057
1 October 2002 Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1683672
25 July 2002 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1652073
11 October 2001 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1075556
9 October 2001 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 478981
23 May 2001 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 504341
7 May 2001 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 482904
9 October 2000 Hull Examination · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1361699
12 April 2000 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 472648
7 December 1999 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 812761
25 March 1999 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1114464
28 January 1999 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1406429
13 November 1998 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 537098
24 September 1998 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 799499
26 February 1998 Re-Inspection · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 780804
13 February 1997 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1456440
13 December 1996 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1091870
14 August 1996 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1085011
10 May 1996 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 486344
12 April 1996 Examination of Repairs · Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1082640
24 March 1996 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 389096
9 February 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 492798
20 October 1995 Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1417830
4 May 1995 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1180780
17 March 1995 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 866054
30 September 1994 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1183034
21 April 1994 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 857994
14 April 1994 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 496396
30 June 1993 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 470448
16 April 1993 COI Inspection · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 841145
22 December 1992 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 438416
4 December 1992 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1136235
30 July 1992 Examination of Repairs · Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 829820
28 January 1992 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 944580
10 December 1991 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 444063
24 May 1991 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1035338
24 May 1991 Deficiency Check · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1341688
25 April 1991 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 524724
25 April 1991 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 930299
25 February 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 501975
22 August 1990 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 490105
19 July 1990 Re-Inspection · Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1230268
15 January 1990 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 515621
6 November 1989 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1022934
21 June 1989 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 444429
15 May 1989 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 889932
19 November 1988 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 502636
2 November 1988 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 889248
28 April 1988 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1346442
2 February 1988 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 450483
14 July 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 464568
14 July 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1329331
8 July 1987 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1016728
21 May 1987 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1333997
13 May 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 525319
23 April 1987 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1007815
6 April 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1326776
3 March 1987 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 451029
20 February 1987 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1322118
19 August 1986 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 521958
19 August 1986 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1294102
14 August 1986 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 998586
13 August 1986 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 440861
20 April 1986 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 538539
5 March 1986 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 502601
5 March 1986 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 986616
7 October 1985 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 532274
18 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285974
8 February 1985 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 534887
25 January 1985 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 536174
28 December 1984 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 976791

Deficiency record · 15

Construction/Loadline › Hull › Hull Plating
Issued 18 December 2007 Resolved
Repair as original 6" fracture at 11' draft in way of #1 port void aft bulkhead in sideshell prior to loading cargo.
Action required: 705 - Other - as specified
Resolved 10 September 2008
Construction/Loadline › Hull › Hull Plating
Issued 25 September 2006 Resolved
#2 Port wing void holding water at level slightly above cargo. Drain void and investigate cause.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 26 October 2006
Deck/Cargo › Holds/Tanks
Issued 1 October 2002 Resolved
Broken dog on hatch to bow void. LEGACY COMPONENT DESC: Hatch Cover
Condition: Unknown
Due 1 November 2002
Resolved 8 October 2002
Resolution: Replaced
Deck/Cargo › Holds/Tanks
Issued 1 October 2002 Resolved
19 wing void covers unsecured and missing dogs
Condition: Unknown
Due 15 October 2002
Resolved 8 October 2002
Resolution: All dogs in place.
Construction/Loadline
Issued 25 April 1991 Resolved
GAS FREE, AND MAKE PROPER REPAIR TO 8 INCH FRACTURE IN GUNNEL, IN WAY OF_x001C_ NUMBER 1 PORT VOID. REPAIRS TO BE COORDINATED WITH LOCAL OCMI AND_x001C_ COMPLETED NO LATER THAN 17MAY91.
Condition: Unknown
Due 25 April 1991
Resolved 25 April 1991
Construction/Loadline
Issued 15 May 1989 Resolved
PERMANENTLY REPAIR 8" DECK KNUCKLE FRACTURE ON STERN AT CENTERLINE AT NEXT GAS FREE AVAILABILITY BUT NOT LATER THAN 15NOV89.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Construction/Loadline
Issued 15 May 1989 Resolved
PERMANENTLY REPAIR 12" DECK KNUCKLE FRACTURE IN WAY OF #7 PORT CAVEL AT NEXT GAS FREE AVAILABILITY BUT NOT LATER THAN 15NOV89.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Deck/Cargo
Issued 14 July 1987 Resolved
REPLACE THE CRACKED SIGHTGLASS ON THE CARGO PUMP GEAR BOX HOUSING.THE PROPER LEVEL OF LUBRICATION OIL CAN NOT BE MAINTAINED,AS OIL SEEPS FROM CRACK ONTO THE DECK.THIS IS TO BE COMPLETED PRIOR TO THE LOADING OF ANY CARGO AND NO LATER THAN 16 AUGUST,1987
Condition: Unknown
Due 14 July 1987
Resolved 14 July 1987
Deck/Cargo
Issued 14 July 1987 Resolved
REPLACE THE WASTED SECTION OF DIESEL FUEL OIL RETURN PIPE LOCATED ON THE DECK DIRECTLY BENEATH THE CARGO HEADER RISER.THIS ITEM IS TO BE COMPLETED PRIOR TO THE LOADING OF ANY CARGO AND NO LATER THAN 16 AUGUST,1987
Condition: Unknown
Due 14 July 1987
Resolved 14 July 1987
Deck/Cargo
Issued 21 May 1987 Resolved
REPLACE MISSING LAGGING ON PUMP ENGINE EXHAUST MANIFOLD.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Construction/Loadline
Issued 21 May 1987 Resolved
PERMANENTLY REPAIR 10" FRACTURE IN BASE WELD OF FORWARD PORTION OF #1 STBD CAVEL
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Construction/Loadline
Issued 6 April 1987 Resolved
MAKE PERMANENT REPAIRS TO A HOLE IN THE STERNBOX THAT IS LOCATED APPROX.3 FEET ABOVE THE WATER PORT SIDE OF AMIDSHIPS,THIS ITEM IS TO BE COMPLETED PRIOR TO THE CARRIAGE OF ANY CARGO.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Construction/Loadline
Issued 14 August 1986 Resolved
MAKE PERMANENT REPAIRS TO 4" VERTICLE FRACTURE ON PORT STERN CORNER WRAPPERIN WAY OF 11' DRAFT AT NEXT GAS FREE AVAILABILITY BUT NOT LATER THAN 14FEB87.
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Deck/Cargo
Issued 14 August 1986 Resolved
RENEW ALL MISSING BUTTERWORTH PLATE BOLTS PRIOR TO LOADING CARGO BUT NOT LATER THAN 31AUG86.
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Deck/Cargo
Issued 5 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE PACKING GLAND RETENTION RING ON THE PORT SIDEAFT HEADER VALVE.THESE REPAIRS ARE TO BE COMPLETED PRIOR TO THE LOADING OF CARGO.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986

Ownership record