Records from 1999 to 2026. Most recent: inspection, 16 March 2026.
Inspection history · 63
16 March 2026
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8326637
16 September 2025
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8235233
10 March 2025
PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8087657
17 February 2025
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8080316
25 July 2024
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7967047
6 May 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7907194
6 November 2023
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7820679
10 April 2023
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7665557
12 September 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7556776
11 February 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7394955
26 October 2021
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7339738
26 October 2021
Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7340050
3 July 2021
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7242851
4 January 2021
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7119130
22 June 2020
PSC B · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6973782
27 April 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6944378
25 November 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6861771
25 March 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6648355
13 March 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6370864
24 February 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6360808
17 December 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6325590
7 April 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6119648
13 February 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6086478
18 July 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5944429
1 July 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5925620
17 June 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5910301
4 January 2016
PII Safety Exam · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5789997
21 December 2015
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5785284
16 June 2014
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4889907
16 June 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4890594
18 June 2012
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4347481
3 May 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4301069
23 January 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4229778
16 December 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4209749
22 December 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3383674
18 August 2008
Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3301913
20 January 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3133482
10 December 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3112595
6 July 2007
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2985468
4 July 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2982857
23 May 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2937945
30 April 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2918841
30 April 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2926309
1 May 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2637657
29 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2612220
28 November 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2541866
17 October 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2515923
2 May 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2347675
22 March 2005
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2316325
6 February 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2297627
4 October 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2213408
17 May 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2070230
29 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2060614
9 February 2004
Ballast Water Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2002767
27 December 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1969931
2 May 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1784997
13 January 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1729595
20 September 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1678373
7 January 2002
Type not recorded
No type recorded · GROUP PHILADELPHIA · USCG East District (CGD-E) · Activity 1475992
17 December 2001
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1477083
7 May 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 289802
9 March 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 275560
20 December 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 466324
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 26 July 2024
Resolved
Each vessel must have the following: An echo depth sounding device. PSCO was informed by the vessel that its echo depth sounding device was inoperable.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 August 2024
Resolution: Inop echo depth sounder was repaired and class survey completed to reflect.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 60 - Rectify deficiencies prior to movement
Due 26 October 2021
Resolved 26 October 2021
Resolution: Recieved satisfactory class report from DNV.
Engineering › Steam System (auxiliary) › Piping
Issued 13 March 2018
Resolved
1499 - Other (Prop. & Aux. Machinery) - Every steam pipe and every fitting connected thereto through which steam may pass shall be designed, constructed, and installed as to withstand the maximum working stresses to which it may be subjected. Multiple steam lines were found to have leaks. - 74 SOLAS (04) II-1/33.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2018
Resolved 13 March 2018
Resolution: Corrected on the spot to the satisfaction of the Coast Guard.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 13 March 2018
Resolved
0750 - Fire Prevention - All waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Wooden waste receptacles were found near the incinerator. 74 SOLAS (01) II-2/18.5
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 March 2018
Resolved 13 March 2018
Resolution: Corrected on the spot to the satisfaction of the Coast Guard.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 13 February 2017
Resolved
Solas 74(2001) II-2/47.1 0710 Stairways which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions and be protected by self closing doors at all levels. Door leading to stairway was not closing without force.
Action required: 705 - Other - as specified
Resolved 13 February 2017
Resolution: Corrected on the spot
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 January 2016
Resolved
1740 - Oil filtering equipment shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. Oil content motor onboard was inoperable at time of exam. 17 ac MARPOL Annex I/14.6
Action required: 705 - Other - as specified
Resolved 4 January 2016
Resolution: Class Report submitted by DNV-GL. OCM replaced with new unit and tested to satisfaction of class.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Cylinder
Issued 4 January 2016
Resolved
The machinery shall be of a desin and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. Excessive oil observed on, under, and around stbd main engine following localized repairs. SOLAS (O4) II-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 January 2016
Resolution: Class report received from DNV-GL. Crew conducted cleaning of area on and around starboard diesel engine to satisfaction of class.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 4 January 2016
Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions and be protected by self closing doors at all levels. Door number surrounding the stairway on the first deck did not effectively self-close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2016
Resolved 27 January 2016
Resolution: Rcvd video attesting to the proper closing of the door.
Lifesaving › Liferaft Equipment
Issued 17 December 2001
Resolved
DURING COURSE OF EXAM. WE WERE ADVISED THAT THE PORT LIFERAFT'S HYDROSTATIC RELEASES HAD BEEN CUT. AFTER VISUAL INSPECTION BOTH UNITS HAD BEEN ACTUATED.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 December 2001
Resolved 17 December 2001
Resolution: RECEIVED FAXED CLASS REPORT.