MAURY USCG vessel records Sign in
← All vessels

BALTIC HOLLYHOCK

BALTIC HOLLYHOCK is a 1999 freight ship. The Coast Guard has recorded 15 inspections since 2009, most recently in July 2026, along with 7 deficiencies and 2 operational controls.

Records from 2009 to 2026. Most recent: inspection, 9 July 2026.

Built
1999
Last inspected
9 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9189902 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
508524
Flag
BAHAMAS, THE
—
Maury page id
psix-508524

Inspections, by type

…with no type recorded7
Years with a record 7 calendar years (2009–2026)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it9649 - Convention (Subpart B), Gross Ton
5349 - Convention (Subpart B), Net Ton
11788 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

9 July 2026 PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8433457
12 December 2025 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8282484
27 September 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7799389
26 September 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7797679
12 November 2021 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7349641
4 March 2020 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6920211
6 December 2010 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3906005
16 February 2010 PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3678033
5 April 2009 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3446472
16 March 2009 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3434861
4 February 2009 Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3412154
2 February 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3403702
2 February 2009 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3403704
1 February 2009 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3403703
31 January 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3403335

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 July 2026 Resolved
EVERY FUEL PIPE, WHICH, IF DAMAGED, WOULD ALLOW OIL TO ESCAPE FROM A STORAGE, SETTLING OR DAILY SERVICE TANK SITUATED ABOVE THE DOUBLE BOTTOM, SHALL BE FITTED WITH A COCK OR VALVE DIRECTLY ON THE TANK CAPABLE OF BEING CLOSED FROM A SAFE POSITION OUTSIDE THE SPACE. PSCO OBSERVED QCV BREAK DURING TESTING. 74SOLAS97 II-2 / 15.2.5 17C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2026
Resolved 14 July 2026
Resolution: CREW FIXED THE QCV HOUSING TO THE SPRING THAT BROKE OFF, TESTED MULTIPLE TIMES SATISFACTORLY.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 July 2026 Resolved
DOORS REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD BACK HOOKS. PSCO OBSERVED SELF CLOSING FIRE DOOR LEADING TO ENGINE ROOM WITH NYLON STRING USED TO HOLD THE DOOR OPEN. 74SOLAS97 II-2 / 47.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2026
Resolved 14 July 2026
Resolution: NYLON LINE WAS REMOVED.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 July 2026 Resolved
THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF OTHER FLAMMABLE OILS EMPLOYED UNDER PRESSURE IN POWER TRANSMISSION SYSTEMS, CONTROL AND ACTIVATION SYSTEMS AND HEATING SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO OBSERVED EXCESSIVE OIL ON LAGGING IN THE PURIFIER ROOM. 74SOLAS97 II-2 / 15.4
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2026
Resolved 14 July 2026
Resolution: CREW CLEANED AND REPLACED LAGGING IN AREA AFFECTED.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCOs observed hull damage on the port side, between frames 28 & 29, in vicinity of cascade & inspection tank.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2021
Resolved 7 December 2021
Resolution: Recieved and reviewed report from surveyor. Extension issued until DEC 2022
Engineering › Steam System (auxiliary) › Valve
Issued 2 February 2009 Resolved
STEAM TRACE ROUTE VALVE #5, should be maintained to ensure the valve is fit to proceed to sea without danger to the ship or persons on board. Valve is leaking steam and has insufficient insulation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2009
Resolved 20 February 2009
Resolution: Received a classification society surveyor''''s report attesting to the proper replacement of steam trace valve #5 insulation. Valve is no longer leaking steam.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 2 February 2009 Resolved
Vessel's Non Tank Vessel Response Plan was in a "PENDING" status upon arrival. Vessel is required to have a NTVRP in an "INTERIM OPS" status prior to arrival.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 2 February 2009
Resolved 4 February 2009
Resolution: Vessel received an "IMTERIM OPS STATUS" on the NTVRP prior to departure.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 1 February 2009 Resolved
Validity of COFR could not be verified against the NPFC website. Issued COTP Order requiring proof of compliance with 33 CFR 138.
Action required: 705 - Other - as specified
Resolved 2 February 2009
Resolution: CDO received verification from NPFC.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.