04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 September 2025
Resolved
Master shall conduct sufficient drills that all crew members are familiar with his or her duties..." Crew is new to operating on this vessel as it has been out of service. Conduct familiarization training with new crew.
46 CFR 185.524
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 September 2025
Resolved
"The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be... made watertight." Penetration for electrical cable above the engine room door was not watertight. Ensure penetration is made watertight.
46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2025
Resolved 12 September 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 September 2025
Resolved
"A hinged watertight bulkhead door must be fitted with quick action closing device operable from both sides of the door..." Hinged watertight door for engine room was not able to be secured. Ensure dogs for engine room watertight door can be tightened.
46 CFR 179.330(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2025
Resolved 12 September 2025
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 8 September 2025
Resolved
"At each inspection for certification... all observed unsafe practices, fire hazards, and other hazardous situations must be corrected..." Manual ventilation opening flaps for engine room was observed to be not operational. Ensure ventilation flaps are operational.
46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2025
Resolved 12 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2025
No resolution recorded
"Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced." 11 lifejackets on top deck were observed to be cracked and not in serviceable condition. Replace the lifejackets not in serviceable condition prior to operating with more than 133 passengers.
46 CFR 176.808(b)
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 July 2025
Resolved
"A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years." Vessel exceeded 2 year dry dock requirement. Prior to carriage of passengers, vessel must receive credit drydock. 46 CFR 115.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2025
Resolution: Vsl completed Hull/ISE.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 March 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel missed dry-dock inspection due 31MAR25.
46 CFR 176.600(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2025
Resolution: Vsl completed Hull/ISE.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 March 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Owner/Operator could not produce evidence of servicing the fixed CO2 fire suppression system.
46 CFR 176.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2025
Resolution: Fixed CO2 system inspected by 3rd party June 2025.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 March 2025
Resolved
The Rules concerning lights (§§ 83.20 through 83.31) shall be complied with from sunset to sunrise, and during such times no other lights shall be exhibited, except such lights as cannot be mistaken for the lights specified in these Rules or do not impair their visibility or distinctive character, or interfere with the keeping of a proper lookout.
33 CFR 83.20(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 March 2025
Resolved
Shutoff valves shall be fitted in the fuel supply lines to stop fuel flow. Fuel shutoff for auxiliary fuel tank is inoperable.
46 CFR 182.20-40(b)(3)
"Old-T"
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2025
Resolution: Completed SAT test for emergency fuel shutoff aux tank.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 31 March 2025
Resolved
Employers must maintain records of chemical tests and must make these records available to Coast Guard officials upon request. Owner/Operator failed to provide Drug and Alcohol Program records.
46 CFR 16.260
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 31 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. 1.) Generator Room transformer bank needs cover. 2.) Alarm Light in generator room needs mounting. 3.) Breaker panel in generator room needs blanks installed. 4.) multiple open wires, open junction boxes, and electrical hazards in the generator room, main engine room, bridge, top deck. Repair to satisfaction of OCMI.
46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2025
Resolution: Transformer in generator room is obsolete and has been removed. Alarm light is mounted in the overhead. No empty spots in breaker panels, blank installed. Mulitple open wires, junction boxes, and electrical hazards in mentioned locations have been removed
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 31 March 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replace. Multiple lifejackets on upper deck were found without retro-reflective tape, and not in serviceable condition. Replace life jackets or remove lifejackets not apart of the official COI Lifejacket count.
46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 March 2025
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engine room bilge had excessive oil accumulation and forepeak had excessive water and debris.
46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 29 July 2025
Resolution: Oily water removed amd imspected engine room for Hull/ISE.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 March 2025
Resolved
Inspection of all accessible parts of the interior of the hull. Forepeak longitudinal has cracked weld, and transverse frame vertical deck stiffener requires weld. Submit repair plan.
46 CFR 176.802(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 29 July 2025
Resolution: Repairs for frame vertical deck stiffener.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 March 2025
Resolved
Installation of diesel engine exhaust pipe shall be in accordance with 182.15-20. Exhaust piping shall be gas tight. Inspector found exhaust leak on the starboard main engine.
46 CFR 182.20-20
"Old T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 12 September 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 31 March 2025
Resolved
At each vessel inspection all observed fire hazards and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. 1.) Vessel has hardwired installed unapproved heater on main deck. 2.) Guard must be installed around alternator on Centerline Diesel Propulsion engine. 3.) Gate or chain to prevent unauthorized passenger access to Bow, and subsequently mark area as Crew Only.
46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 23 July 2025
Resolution: Heater has been removed and centerline engine guard has been installed for the alternator.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 31 March 2025
Resolved
Special attention shall be paid to insure that guards or protective devices are provided in all hazardous places. No lagging on port and starboard main engine exhaust.
46 CFR 176.25-10(b)
"Old T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 23 July 2025
Resolution: Exhaust lagging has been installed on Port and STBD exhaust.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 March 2025
Resolved
All electrical installations shall be to the satisfaction of the [name withheld] wiring was not mounted.
46 CFR 183.01-15
"Old T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 23 July 2025
Resolution: Radar wires have been properly mounted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 March 2025
Resolved
Batteries shall be secured against shifting with motion of the boat. Starboard generator battery and battery under helm in the bridge were not secured.
46 CFR 183.05-20(a)
"Old T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 23 July 2025
Resolution: Batteries have been installed in battery boxes and secured to the deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 March 2025
Resolved
Remote fuel shutoff stations shall be marked in at least 1 inch letters indicating purpose of the valve and the direction of operation. Fuel shutoff valves had no labeling.
46 cfr 185.30-20
"Old T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 23 July 2025
Resolution: Remote shutoffs have been labelled and direction to off as well.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 31 March 2025
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel’s stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25millimeters (1 inch) numbers and letters at the entrance way to that deck. Aft Stairwell leading up to upper deck is not marked with maximum passengers.
46 CFR 185.602(g)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 23 July 2025
Resolution: Access to upper deck has signage posted with max capacity of upper deck.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 31 March 2025
Resolved
Master shall conduct sufficient drills that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard or in case of a fire. These items shall be logged or otherwise documented for review by the coast guard upon request. Vessel has not been operating and has not been conducting drills, prior to re-completing the COI vessel shall conduct drills prior to USCG arrival.
46 CFR 185.524
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2025
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 31 March 2025
Resolved
The stability letter must be posted under glass or other suitable transparent material that all pages are visible at the operating station of the vessel. If impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request.
46 CFR 178.306
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 23 July 2025
Resolution: Stability letter is posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 March 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station emergency instructions containing actions to be taken in the event of Fire, Heavy Weather, or Man overboard conditions. Vessel does not have emergency instructions posted at the operating station.
46 CFR 185.510
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 23 July 2025
Resolution: Crew emergency stations posted at the operating station.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 March 2025
Resolved
Vessel must carry a first aid kit approved under approval series or a kit with equivalent contents and instructions. Vessel’s first aid kit had expired items. Replace expired items.
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 8 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2024
Resolved
No pressure vessel need be hydrostatically tested except when a defect is found that, in the marine inspector's opinion, may affect the safety of the pressure vessel. No records present of both pressure vessels last inspection date and pressure vessels showing signs of corrosion internally. Hydrostatically test both pressure vessels at 1.5xMAWP through a 3rd party and provide record of testing to marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2024
Resolution: 3rd party sat test on 02FEB24
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 January 2024
Resolved
This term means that the operator of the vessel may start and stop the engines and control the direction and
speed of the propeller from the principal station from which the vessel is steered. Repair malfunctioning remote, emergency stops for main propulsion machinery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2024
Resolution: Resolved electrical issue.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 31 January 2024
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment
that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Restore all malfunctioning gauges on electrical switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 25 March 2024
Resolution: Objective photographic and video evidence obtained.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 31 January 2024
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include—
(1) Closing each valve leading to an overboard discharge and removing the handle;
(2) Padlocking each valve leading to an overboard discharge in the closed position; or
(3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position.
Type III device was not secured in an acceptable manner to prevent accidental discharge of sewage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 25 March 2024
Resolution: Objective photographic evidence obtained.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 January 2024
Resolved
At least one ring life buoy must be fitted with a lifeline... Each lifeline on a ring life buoy must: (1) Be buoyant; (2) Be of at least 18.3 meters (60 feet) in length; (3) Be non-kinking; (4) Have a diameter of at least 7.9 millimeters (5/16 inch); (5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and (6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. No lifeline observed on vessel's life buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 25 March 2024
Resolution: Objective photographic evidence obtained.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2024
Resolved
(1) On passenger decks of a ferry...the following must be installed: (i) Bulwarks; (ii) Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter; or (iii) Bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches). Insufficient rail courses or equivalent installations on the Main Dk access the rescue boat deck (aft quarter of port side).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 25 March 2024
Resolution: Objective photographic evidence obtained.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 January 2024
Resolved
At each inspection for certification...the bilges...may be examined to see that there is no excessive accumulation of oil... that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Excessive oil accumulation under port generator's bilge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 25 March 2024
Resolution: Objective photographic evidence obtained.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2024
Resolved
(a)Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels...
(d)Marine employers may... use sponsoring organizations, or may use contractors, to conduct the random chemical testing programs required by this part. Operator did not have proof of crew enrollment in Drug and Alcohol Consortium agency. Email a copy/objective evidence of all crew mbr's enrollment and designated testing crew mbr.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 5 April 2024
Resolution: Copy of DAP enrollment sent in.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 January 2024
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. Operator will install dual-point mounting brackets for all required fire extinguishers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 25 March 2024
Resolution: Objective photographic evidence obtained.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 31 January 2024
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the following:
Discharge of Oil Prohibited
The Federal Water Pollution Control Act prohibits the discharge of oil or oily waste into or upon the navigable waters of the United States, or the waters of the contiguous zone, or which may affect natural resources belonging to, appertaining to, or under the exclusive management authority of the United States, if such discharge causes a film or discoloration of the surface of the water or causes a sludge or emulsion beneath the surface of the water. Violators are subject to substantial civil penalties and/or criminal sanctions including fines and imprisonment.
Operator will obtain the specified placard and post.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 25 March 2024
Resolution: Objective photographic evidence obtained.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 31 January 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel...giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places...Pending a structural review of upper deck support, Passenger limit of 60 imposed on upper deck.
Action required: 705 - Other - as specified
Resolved 15 April 2024
Resolution: Ongoing. Captured in routes and conditions as well as special note.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 10 January 2024
Resolved
Every ship of 12 m or more in length overall and fixed or floating platforms shall display placards which notify the crew and passengers of the discharge requirements of regulations 3, 4, 5 and 6 of this Annex...A placard must be posted in a prominent location, durable make, and at least 5in x 8in prohibiting the discharge of garbage into the sea.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 25 March 2024
Resolution: Objective photographic evidence obtained.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 10 January 2024
Resolved
Each [marine sanitation] device must have a placard suitable for posting on which is printed the operating instructions, safety precautions, and warnings pertinent to the device. The size of the letters printed on the placard must be one-eighth of an inch or larger. A placard must be posted in a prominent location, durable make, and at least 5in x 8in prohibiting the discharge of sewage into the sea.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 25 March 2024