MAURY USCG vessel records Sign in
← All vessels

ANGELICA AN

ANGELICA AN is a 1999 tank ship. The Coast Guard has recorded 22 inspections since 2000, most recently in May 2017, along with 5 deficiencies and 3 operational controls.

Records from 2000 to 2017. Most recent: inspection, 18 May 2017.

Built
1999
Last inspected
18 May 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9198290 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
508781
Flag
MALTA
—
Maury page id
psix-508781

Inspections, by type

…with no type recorded7
Years with a record 10 calendar years (2000–2017)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28246 - Convention (Subpart B), Gross Ton
46408 - Dead Weight, Ton
56091 - Displacement, Ton
12481 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

18 May 2017 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6149302
21 April 2017 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6132278
14 April 2017 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6124459
27 March 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3703939
20 March 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3699432
19 March 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3699064
25 March 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3440248
19 January 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3396454
18 July 2008 MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex II Examination · Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3263768
19 March 2008 ILO-147 Exam · Ballast Water Examination · STCW 95 Exam · ISPS II Exam · Loadline Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3162430
22 August 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2751925
31 July 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2731946
3 July 2006 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2700113
6 April 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2618066
14 July 2005 ISPS II Exam · COC-TVE Renew · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2426153
3 February 2003 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1739182
2 February 2002 Certificate of Compliance
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1483485
7 October 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 294521
6 October 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 294566
1 February 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 286581
1 February 2001 Tank Vessel Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1058761
4 February 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 274278

Deficiency record · 5

Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 24 April 2017 Resolved
The inert gas system shall be capable of inerting, purging and gas freeing empty tanks and maintaining the atmosphere in cargo tanks with the required oxygen content. Vessels IGG combustion chamber has pinhole within inner wall at weld sea causing cooling water to enter chamber and prevent system from operating as normal. * ABS issued condition of class (90 Days)
Action required: 705 - Other - as specified
Due 23 July 2017
Resolved 18 May 2017
Resolution: Received a classificartion society report and follow-up email attesting to the satisfactory repair and testing of the IGG system.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 21 April 2017 Resolved
Vessels IGG combustion chamber has pin hole within inner wall at weld seam causing cooling water to enter chamber and preventing system from operating as normal. Vessels secondary system is also not operating as required, oxygen level is at 11%.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2017
Resolution: Vessel's secondary means of producing intert gas is fully operational, via Auxilary Boiler.
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 March 2010 Resolved
The Radar was reported as not operational
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2010
Resolved 27 March 2010
Resolution: Received, reviewed and accepted tech report from Sperry Marine stating the Radar was repaired, tested and found satisfactory.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 3 July 2006 Resolved
OILY CONTENT MONITOR IS OUT OF CALIBRATION DUE TO IMPROPER MAINTENANCE. SUBMIT TECHNICIAN'S REPORT ATTESTING TO SATISFACTORY CALIBRATION AND OPERATION OF THE OILY CONTENT MONITOR PRIOR TO DEPARTURE FROM PORT.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2006
Resolution: Receive technicians report attesting to proper calibration and operation
Engineering › Bilge Water Management System › Piping
Issued 3 July 2006 Resolved
FIRE HOSES ARE BEING USED FOR GRAY WATER DISCHARGE INTO BILGE. REPLACE WITH PERMANENT PIPING TO THE SATISFACTION OF CLASS.
Action required: 705 - Other - as specified
Resolved 22 August 2006
Resolution: Repairs were made to the satisfaction of the classification society.

Ownership record