Records from 1999 to 2025. Most recent: inspection, 13 February 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
13 February 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8079374
8 May 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7887978
26 April 2023
Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7674345
26 April 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7438564
26 April 2021
Hull Examination · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7183379
3 June 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6965586
2 May 2019
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6674848
30 April 2018
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6402767
3 May 2017
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6137790
9 May 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5872240
6 May 2014
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4851526
7 May 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4304698
5 December 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4202116
29 April 2009
Hull Examination · Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3464017
7 May 2008
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3199397
14 September 2007
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3065115
23 April 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2914629
11 May 2005
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2355136
26 October 2004
Deficiency Check · MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2228331
26 August 2003
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1888065
30 April 2003
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1783395
6 December 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1077263
25 September 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1443269
12 April 2001
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1428001
28 September 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1406811
24 January 2000
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1438942
2 September 1999
Hull Examination · Initial Certification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 815938
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2024
Resolved
"Each child life size jacket must be stowed in a location that is... separated from adult life jackets." The child life jackets on board were not separated from the adult life jackets. Separate the different life jackets.
46 CFR 180.78(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Vessel's operator provided pictures of labeled compartment for life jackets as well as seperated adult-sized life jackets from child-sized life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2024
Resolved
"Each... ring life buoy must be marked in clearly legible block capital letters with the vessel's name." The writing on the ring life buoy on board was not legible. Ensure writing is legible.
46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Vessel's operator renewed ring life buoy.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2024
Resolved
"A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions." Vessel did not have the appropriate First Aid Kit; several items inside were expired. Ensure First Aid Kit has appropriate items.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Vessel operator replaced full first aid kit. Picture is provided under documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2024
Resolved
"Each ring buoy must have the following information in waterproof lettering:Type IV Personal Flotation Device. Inspected and tested in accordance with U.S. Coast Guard regulations. (Name of buoyant material) buoyant material provides a minimum buoyant force of (32 lb. or 161/2 lb. Approved for use on recreational boats only as a throwable device. U.S. Coast Guard Approval No. 160.050/(assigned manufacturer's No.)/(Revision No.); (Model No.). (Name and address of manufacturer or distributor). (Size). USCG (Marine Inspection Office identification letters). (Lot No.)." The above information was not found on ring life buoy. Ensure information is provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Ring life buoy was renewed to standards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 May 2024
Resolved
"Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation." The label for remote shutoff was unclear. Ensure labeling is clear.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Vessel's operator provided a picture of labeling for remote shutoff.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 April 2018
Resolved
A vessel may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel's COI expired on 4/25/2018 and shall complete required COI inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2018
Resolution: Vessel successfully completed COI inspection.
Engineering › Fuel Oil Service System › Filter
Issued 6 May 2014
Resolved
CW01- Replace fuel strainer bowl with new bowl.
Action required: 705 - Other - as specified
Due 13 May 2014
Resolved 8 May 2014
Resolution: Recieved pictures and reciept of new fuel strainer bowl/deflector installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 May 2014
Resolved
CW02- Replace lightbulb on stern light. Demonstrate proper operation.
Due 6 May 2014
Resolved 6 May 2014
Resolution: Vessel rep replaced the lightbulb. Verified proper operation.
Documentation › Certificates/Documents › Stability Letter
Issued 5 December 2011
Resolved
Owner/Operator failed to submit stability certification compliance by 01DEC11. Issued CG-835 reducing maximum persons allowed to 18 based on the assumed average weight per person of 185 pounds and in accordance with 46 CFR 178.320 amended by FR vol. 75, No. 239, USCG-2007-0030. Reduction will remain in effect until Owner/Operator submits stability certification compliance to Coast Guard.
Action required: 705 - Other - as specified
Resolved 7 May 2012
Resolution: Vessel submitted AAWPP compliance documentation attesting to weight ratio reduction. Passenger count amended, deficiency cleared.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 29 April 2009
Resolved
Properly label lifejacket storage area.
Action required: 705 - Other - as specified
Due 29 May 2009
Resolved 29 April 2009
Construction/Loadline › Structures › Machinery Space Opening
Issued 29 April 2009
Resolved
Make repairs to wasted engine compartment coaming support, port side, engine comparment.
Action required: 705 - Other - as specified
Due 29 May 2009
Resolved 2 November 2009
Resolution: Received photo from vessel representative. Photo shows the repairs made to the wasted hatch coaming support, port side, engine compartment. Deficiency cleared.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 7 May 2008
Resolved
Prove proper operation of the fixed fire fighting system prior to issuance of COI. Vessel is limited to the carraige of 6 passengers or less.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Piping
Issued 26 October 2004
Resolved
Provide documentation of required annual fixed fire extinguishing servicing.
Due 9 November 2004
Resolved 16 November 2004
Resolution: Observed current servicing tag.
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 October 2004
Resolved
Perform drills with all captains and log the same in the vsl's official log book.
Due 24 November 2004
Resolved 2 December 2004
Resolution: [name withheld] provided a written statement that he understands the requirement to conduct drills on a monthly basis and to log these drills.
Operations/Management › Drills/Instruction › Fire
Issued 26 October 2004
Resolved
Provide a copy of vsl specific emergency instructions as required by 46 CFR 185.510.
Due 24 November 2004
Resolved 2 December 2004
Resolution: [name withheld] provided vsl specific procedures via e-mail that he will make available on board the vessel and use as the basis of training he conducts with his other captains. I copy was filed in the vsl file.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 October 2004
Resolved
Provide a means for leaving the passenger count ashore as required by 46 CFR 185.604.
Due 24 November 2004
Resolved 2 December 2004
Resolution: [name withheld] stated he will attach a weatherproof writing surface on the steps where pax board. The master will record departure time and pax count.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 October 2004
Resolved
Provide means to segregate adult and child lifejackets as required by 46 CFR 180.78(a)(5).
Due 9 November 2004
Resolved 16 November 2004
Resolution: Vsl rep. put lifejackets in garbage bag and installed under fwd, starboard bench.
Fire Fighting › Fire Bucket › Availability
Issued 26 October 2004
Resolved
Provide 3, 2.5 gallon fire buckets with an attached lanyard and labelled in accordance with 46 CFR 181.610.
Due 9 November 2004
Resolved 16 November 2004
Resolution: Observed 3, 2.5 gallon buckets appropriately labelled.
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 26 October 2004
Resolved
Make rudder post watertight.
Due 30 April 2005
Resolved 24 April 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 October 2004
Resolved
Replace flexible hose for the engine raw water cooling system IWO the through hull fitting and the filter. The replacement hose must meet the standard SAE J-1942.
Due 9 November 2004
Resolved 16 November 2004
Resolution: Vsl rep replaced hose with new flexible hose meeting SAE J-1942.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 October 2004
Resolved
Remove or properly terminate dead end wires IVO engine transmission.
Due 9 November 2004
Resolved 23 November 2004
Resolution: Removed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 October 2004
Resolved
Provide a copy of the stability letter and COI on board the vsl while carrying passengers.
Due 9 November 2004
Resolved 16 November 2004
Resolution: Observed laminated copies of the stability letter and COI posted at pier side work house.
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 26 October 2004
Resolved
Provide at least one portable light as required by 46 CFR 183.430 for the operating station.
Due 9 November 2004
Resolved 16 November 2004
Resolution: One flashlight installed at the operating station.
Documentation › Certificates/Documents
Issued 26 August 2003
Resolved
Post (have onboard) the vessels COI and Stability Letter.
Due 9 September 2003
Resolved 25 September 2003
Operations/Management › Drug and Alcohol Testing
Issued 26 August 2003
Resolved
Post Hotline numbers and prove that supervisor has attended required training.
Due 9 September 2003
Resolved 23 September 2003
Operations/Management › Drills/Instruction
Issued 26 August 2003
Resolved
Provide up to date training records.
Due 9 September 2003
Resolved 23 September 2003
Documentation › Manuals/Policy Documentation
Issued 26 August 2003
Resolved
Post emergency instructions LEGACY COMPONENT DESC: Emergency Instructions
Due 9 September 2003
Resolved 25 September 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 26 August 2003
Resolved
Mount portable fire extinguishers LEGACY COMPONENT DESC: Mounting Bracket
Due 28 August 2003
Resolved 26 August 2003
Lifesaving › Lifebuoys
Issued 26 August 2003
Resolved
Prove proper operation of lifebuoy waterlight (in the water) LEGACY COMPONENT DESC: Self-igniting Lights
Due 28 August 2003
Resolved 26 August 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 26 August 2003
Resolved
Install electrical grounding wire for use with flex fuel hoses. LEGACY COMPONENT DESC: Hose
Due 9 September 2003
Resolved 23 September 2003
Lifesaving
Issued 25 September 2001
Resolved
Provide 3 red flares vessel is required to have 3 red flares and 3 orange flares
Condition: Unknown
Due 22 October 2001
Resolved 22 October 2001
Navigation
Issued 25 September 2001
Resolved
Provide Emergency intructions IAW 46CFR185.510
Condition: Unknown
Due 25 September 2001
Resolved 25 September 2001
Lifesaving
Issued 25 September 2001
Resolved
provide 3 foot lanyard with corrosion resistant clip for waterlight.
Condition: Unknown
Due 25 September 2001
Resolved 25 September 2001
Lifesaving
Issued 25 September 2001
Resolved
Install retroreflective tape to Life Ring. 4 evenly spaced distances around circumference of L/R.
Condition: Unknown
Due 25 September 2001
Resolved 25 September 2001
Lifesaving
Issued 25 September 2001
Resolved
Provide 60 foot life line to ring bouy
Condition: Unknown
Due 25 September 2001
Resolved 25 September 2001
Construction/Loadline
Issued 28 September 2000
Resolved
Provide a retention line for the engine hatch.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Construction/Loadline
Issued 28 September 2000
Resolved
Prove proper operation of bilge pump visual indicator at operator's consoleand properly supply power to alarm circuit from fused battery bus.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Electrical
Issued 28 September 2000
Resolved
Provide a battery box/cover.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Lifesaving
Issued 28 September 2000
Resolved
Provide 60' of black or UV resistant, floating line for life ring buoy.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Lifesaving
Issued 28 September 2000
Resolved
Provide a 3' lanyard with a corrosion resistant clip for attachment of floating water light to life ring buoy.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Construction/Loadline
Issued 28 September 2000
Resolved
Prove proper operation of bilge high level alarm.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Electrical
Issued 28 September 2000
Resolved
Provide portable lights/emergency lights.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Lifesaving
Issued 28 September 2000
Resolved
Provide retroreflective tape on life ring buoy.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000