Records from 2016 to 2025. Most recent: inspection, 13 February 2025.
Inspection history · 10
13 February 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8079384
8 May 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7887975
26 April 2023
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7674519
27 April 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7438557
26 April 2021
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7183343
3 June 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6965581
2 May 2019
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6674854
30 April 2018
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6402773
3 May 2017
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6137786
9 May 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5872245
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2024
Resolved
"Each child life size jacket must be stowed in a location that is... separated from adult life jackets." The child life jackets on board were not separated from the adult life jackets. Separate the different life jackets.
46 CFR 180.78(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Life jacket compartment was labeled and adult-sized life jackets were seprated from child-sized life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2024
Resolved
"Each... ring life buoy must be marked in clearly legible block capital letters with the vessel's name." The writing on the ring life buoy on board was not legible. Ensure writing is legible.
46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Vessel's operator provide photo of brand new ring life buoy with correct markings.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 May 2024
Resolved
"A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions." Vessel did not have the appropriate First Aid Kit; several items inside were expired. Ensure First Aid Kit has appropriate items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Vessel's operator replaced with approved first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2024
Resolved
"Each ring buoy must have the following information in waterproof lettering:Type IV Personal Flotation Device. Inspected and tested in accordance with U.S. Coast Guard regulations. (Name of buoyant material) buoyant material provides a minimum buoyant force of (32 lb. or 161/2 lb. Approved for use on recreational boats only as a throwable device. U.S. Coast Guard Approval No. 160.050/(assigned manufacturer's No.)/(Revision No.); (Model No.). (Name and address of manufacturer or distributor). (Size). USCG (Marine Inspection Office identification letters). (Lot No.)." The above information was not found on ring life buoy. Ensure information is provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Life ring buoy was replaced and a photo was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 May 2024
Resolved
"Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation." The label for remote shutoff was unclear. Ensure labeling is clear.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2024
Resolution: Vessel's operator label remote fuel shutoff valve on access door leading to valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 May 2024
Resolved
"All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury." Vessel was missing a machinery guard for its engine.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Vessel's operator provide a photo of guard around engine belt drive.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 April 2018
Resolved
A vessel may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel's COI expired on 4/25/2018 and shall complete required COI inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2018
Resolution: Vessel successfully completed COI inspection.