← All vessels
SEA FLOWER
Freight Ship · Ro-Ro Cargo Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named SEA FLOWER
SEA FLOWER is a 1971 freight ship. The Coast Guard has recorded 132 inspections since 2000, most recently in February 2024, along with 191 deficiencies and 66 operational controls.
Records from 2000 to 2024. Most recent: inspection, 29 February 2024.
- Built
- 1971
- Last inspected
- 29 February 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Inspections
- 132
- Deficiencies
- 191 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7053238 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
CPB-855
508970
Flag
BOLIVIA
—
Maury page id
psix-508970
Inspections, by type
…with no type recorded90
Years with a record
13 calendar years (2000–2024)
The 132 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it678 - Regulatory (Subpart C or D), Gross Ton
1817 - Convention (Subpart B), Gross Ton
1368 - Convention (Subpart B), Net Ton
1817 - Convention (Subpart B), Gross Ton
1368 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 132
29 February 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7872002
5 February 2011
PII Safety Exam · Administrative Inspection · ISPS III Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3939763
21 December 2010
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3913608
30 November 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3899749
31 October 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3881604
18 October 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3871107
28 September 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3858687
12 September 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3847935
6 March 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3689442
7 January 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3659017
22 April 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3456536
22 April 2009
ISPS I Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3458266
16 March 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3433708
16 March 2009
ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3434058
26 January 2009
ILO-147 Exam · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3396728
20 October 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3349226
17 October 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3346813
30 September 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3335578
22 September 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3330095
21 September 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3329311
16 August 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3301306
14 August 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3298509
23 June 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3245480
21 June 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3243201
5 May 2008
ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3199022
2 May 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3199100
13 February 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3150488
12 February 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3146461
8 January 2008
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3125860
3 January 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3124270
12 December 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3114129
10 December 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3112903
15 November 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3098929
17 October 2007
ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3081449
30 July 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3011783
27 July 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3008844
8 May 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2924946
19 April 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2910672
10 October 2006
PI Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2797186
21 August 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2755351
20 August 2006
Ballast Water Examination · PI Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2751921
25 June 2006
Type not recorded
No type recorded · Maritime Safety & Security Team Miami (91114) · Activity 2691178
31 May 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2666586
24 May 2006
Random ISPS/MTSA/PSC
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2658075
22 May 2006
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2655751
22 May 2006
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2656065
15 May 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2649506
23 April 2006
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2631318
9 March 2006
ISPS III Exam · PI Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2599443
28 February 2006
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2593125
17 February 2006
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2587151
9 February 2006
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2582302
31 January 2006
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2576664
20 January 2006
ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2570186
10 January 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2584380
8 January 2006
PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2562996
29 November 2005
NPV Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2542846
16 October 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2515577
3 October 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2507191
23 September 2005
PI Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2499271
18 September 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2495143
29 July 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2444149
18 July 2005
Ballast Water Examination · ISPS III Exam · MARPOL Annex I Examination · ISM Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2430490
12 July 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2424582
8 June 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2383505
26 May 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2368978
25 May 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2367741
25 May 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2368019
23 May 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2368637
17 May 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2359976
1 May 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2346626
21 April 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2339418
16 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2335152
5 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2327449
2 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2324972
17 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2313194
4 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2303777
1 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2301156
14 February 2005
PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2291951
11 February 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2292028
8 February 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2288379
22 January 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2279002
6 January 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2269746
22 December 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2263468
14 December 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2260712
11 December 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2257315
1 December 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2252952
26 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2248367
11 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2239255
30 October 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2232612
27 October 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2229106
14 October 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2221562
9 October 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2217195
24 September 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2203774
7 September 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2193514
6 September 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2188515
6 September 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2188525
21 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2173114
18 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2169514
7 August 2004
PII Safety Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2158534
6 August 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2159444
4 August 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2155854
23 July 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2143346
21 July 2004
Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2140105
9 July 2004
ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2127585
7 July 2004
Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2124878
7 July 2004
Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2124950
22 June 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2107054
7 June 2004
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2091203
5 June 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2089340
22 May 2004
Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2075154
8 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2062348
26 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2054394
24 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2051525
6 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2037249
21 March 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2028434
20 March 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2027894
27 January 2004
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1994266
10 July 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1841530
8 July 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1839877
29 May 2003
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1804628
4 April 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1768007
18 February 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1746054
3 January 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1725476
19 November 2002
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1707328
22 October 2002
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1693921
23 May 2002
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1619953
29 June 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 291215
18 May 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 290329
11 January 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 285974
3 February 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 110151
28 January 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 274010
Deficiency record · 191
Construction/Loadline › Hull › Transverse Frame
Issued 4 March 2011
Resolved
The administration shall satisfy itself that the general structural strength of the hull is adequate strength. The framing, overhead, and decking in aft steering is severely wasted. ICLL ANNEX I/1 17bc
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 March 2011
Resolved
AFTER ANY SURVEY OF THE SHIP UNDER ARTICLE 14 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURE, EQUIPMENT, ARRANGEMENTS, MATERIAL OR SCANTLINGS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. THE FORWARD WATERTIGHT BULKHEAD IN AFT STEERING HAS TWO HOLES IN THE BOTTOM, A HOLE DRILLED IN THE TOP, AND AN EMPTY STUFFING TUBE NEAR THE OVERHEAD. ILLC Article 15 17bc
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 4 March 2011
Resolved
EACH LIFERAFT SHALL BE STOWED WITH A FLOAT FREE ARRANGEMENT SO THAT EACH FLOATS FREE AND INFLATES AUTOMATICALLY. VESSEL'S STBD LIFERAFT IS NOT STORED PROPERLY. HYDROSTATIC RELEASE WAS NOT CONNECTED PROPERLY. SOLAS 09' ch. 3 Reg 14.4.2 10c
Electrical › Electrical Distribution System (service) › Switchboard
Issued 4 March 2011
Resolved
MAIN AND EMERGENCY SWITCHBOARDS SHALL BE SO ARRANGED TO GIVE EASY ACCESS BACK AND FRONT, WITHOUT DANGER TO ATTENDANTS AND SHALL BE SUITABLY GUARDED. THE BACK OF TWO ELECTRICAL CONTROL PANELS IN THE ENGINE ROOM HAD EXPOSED WIRING. SoLAS 60 ch. 2 reg. 27 a (ii) 10c
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 4 March 2011
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 February 2011
Resolved
OIL FILTERING EQUIPMENT SHALL BE OF A DESIGN APPROVED BY THE ADMINISTRATION AND SHALL BE SUCH AS WILL ENSURE THAT ANY OIL MIXTURE DISCHARGED INTO THE SEA AFTER PASSING THROUGH THE SYSTEM HAS AN OIL CONTENT NOT TO EXCEED 15 PARTS PER MILLION. THE VESSEL'S OIL FILTERING EQUIPMENT PASSED OIL MIXTURE THROUGH THE SYSTEM AFTER 15 PPM WAS DISPLAYED ON THE OIL CONTENT METER. MARPOL 73/78 ANNEX I/3/14.6
Electrical › Electrical Distribution System (emergency) › Cable
Issued 5 February 2011
Resolved
ALL EXPOSED PARTS OF ELECTRICAL EQUIPEMENT WHICH ARE NOT INTENDED TO BE LIVE, BUT ARE LIABLE TO BECOME LIVE UNDER FAULT CONDITIONS SHALL BE SO CONSTRUCTED AND SO INSTALLED THAT DANGER OF INJURT IN ORDINARY HANDLING SHALL NOT EXIST. THE ELECTRICAL SHORE TIE WAS FOUND ON THE DECK WITH THE WIRES WRAPPED IN ELECTRICAL TAPE. SOLAS 60 ch.2 part c reg 27 a (i) 1
Engineering › Steering Gear System › Rudder Stock
Issued 20 December 2010
Resolved
CHANGES AFTER SURVERY. THE RUDDER STOCK IS LEAKING; HOSES RIGGED TO DRAIN STEERING COMPARTMENT. HOSES PENETRATE WATERTIGHT BULKHEAD BETWEEN STEERING FLAT AND ENGINE ROOM. MULTIPLE SOFT PATCHES ON GENERATOR COOLANT LINES, AND MISSING CAPS FOR COOLANT RESERVOIRS. GUARDS ON GENERATORS DO NOT PROVIDE FULL PROTECTION FROM ROTATING MACHINERY. (74 SOLAS CH I/11)
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 December 2010
Resolved
IN ANY CARGO SHIP, THERE SHALL BE PERMANENTLY EXHIBITED PLANS SHOWING CLEARLY FOR EACH DECK THE CONTROL STATIONS, THE VARIOUS FIRE SECTIONS ENCLOSED BY FIRE-RESISTING BULKHEADS, THE SECTIONS ENCLOSED BY FIRE-RETARDING BULKHEADS ETC. VESSEL'S FIRE CONTROL PLAN DOES NOT SHOW CLASS BOUNDARIES. (SOLAS 60 CH II/ REG 70)
Navigation › Piloting/Steering › Gyro Compass
Issued 20 December 2010
Resolved
ALL SHIPS OF 500 GT AND UP SHALL HAVE A GYROCOMPASS COMPASS, OR OTHER MEANS, TO DISPLAY THEIR HEADING BY SHIPBORNE MAGNETIC MEANS. VESSEL'S GYROCOMPASS AND REPEATER ARE INOPERABLE. 33CFR164.35(d)
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 20 December 2010
Resolved
THE HOUSEKEEPING OF DECK, ENGINE AND CATERING DEPARTMENT STOREROOMS, PAINT AND STEERING GEAR ROOMS AND OTHER SUCH SPACES, SHALL ENSURE THE AVOIDANCE OF SITUATIONS PRESENTING A FIRE HAZARD. COMBUSTIBLES (CARDBOARD BOXES) FOUND IN ENGINE SPACE AND STEERING GEAR ROOM. (33 USC 1223 & ILO 147)
Communications › Internal Communications System › Engine Order Telegraph System
Issued 20 December 2010
Resolved
SHIPS SHALL BE FITTED WITH TWO MEANS OF COMMUNICATING ORDERS FROM THE BRIDGE TO THE ENGINE ROOM. ONE MEANS SHALL BE AN ENGINE ROOM TELEGRAPH. STEERING GEAR ROOM TWO-WAY SPEAKER WITH BRIDGE INOPERABLE. (SOLAS 60 CH II/33)
SOLAS 60 CH II/ REG 33
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 December 2010
Resolved
OVERHEAD OF MAIN DECK CARGO HOLD, ABOVE WATERTIGHT DOOR NEAR THE GANGWAY (OPENING TO THE STAIRWELL AND ENGINE ROOM), PORT SIDE IS WASTED. HOLE IN FRONT SIDE OF SUPERSTRUCTURE (TRANSVERSE WATERTIGHT BULKHEAD), FAR STARBOARD SIDE AT DECK LEVEL IN CORNER. TWO HOLES IN AFT BULKHEAD OF ELECTRICAL LOCKER SPACE. (ILLC 1966 ANNEX I/16.4)
Fire Fighting › Fire Main › Condition
Issued 20 December 2010
Resolved
MAIN FIRE PUMP LEAKING AND SEVERELY WASTED. FIRE MAIN BURST ON THE POOP DECK STBD, AND TWO HOSE STATIONS HAD LEAKS, ONE ON THE BRIDGE WING AND ONE ON THE STBD SIDE MAIN DECK FWD. RESULTED IN REDUCED FIRE MAIN PRESSURE SUCH THAT TWO EFFECTIVE STREAMS OF WATER COULD NOT BE MAINTAINED. (SOLAS 60 CH II/66)
Lifesaving › Launching Appliances › Winch
Issued 20 December 2010
Resolved
RESCUE (EMERGENCY) BOATS SHALL BE SERVED BY WIRE ROPE FALLS, TOGETHER WITH WINCHES OF AN APPROVED TYPE WINCH, IN THE CASE OF EMERGENCY BOATS SHALL BE CAPABLE OF QUICK RECOVERY OF THOSE BOATS. IT TOOK 45 MINUTES FOR THE WINCH TO RECOVER THE EMERGENCY BOAT, THUS NOT BEING ABLE TO QUICKLY RECOVER THE BOAT. (SOLAS 60 CH III/36(i))
Lifesaving › Launching Appliances › Lines
Issued 20 December 2010
Resolved
AT LEAST TWO LIFELINES SHALL BE FITTED TO THE DAVIT SPANS. THE LIFELINES WERE DETERIORATED TO THE POINT THAT ONCE WEIGHT WAS ADDED THE LINES PARTED AND FELL INTO THE RESCUE BOAT. (SOLAS 60 CH III/36(J))
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 20 December 2010
Resolved
SHIPS SHALL CARRY A LINE-THROWING APPLIANCE AND IT SHALL INCLUDE NOT LESS THAN FOUR PROJECTILES AND FOUR LINES. ONLY THREE PROJECTILES AND THREE LINES WERE ON THE VESSEL. (SOLAS 60 CH. III/ REG 23)
Fire Fighting › Structural - A Class Divisions › Doors
Issued 20 December 2010
Resolved
THE DOOR LEADING INTO THE GALLEY WAS WARPED AT THE BOTTOM PROVIDING AN APPROXIMATE 1.5 CM GAP WHICH WOULD ALLOW FOR IMMEDIATE PASSAGE OF SMOKE AND FLAME IN THE EVENT OF A FIRE, THUS NOT MEETING THE REQUIREMENT OF THE STANDARD ONE-HOUR FIRE TEST. (SOLAS 60 CH. II/35 (C) (iii))
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 20 December 2010
Resolved
ALL SHIPS 300GT AND UPWARDS SHALL BE FITTED WITH AN ECHO-DEPTH SOUNDING DEVICE. NO ECHO-DEPTH SOUNDING DEVICE WAS ONBOARD AS REQUIRED BY THE SAFETY EQUIPMENT CERTIFICATE AND SOLAS. 33CFR164.35(h)
Engineering › Steering Gear System › Rudder
Issued 20 December 2010
Resolved
THE MAIN STEERING GEAR SHALL BE OF ADEQUATE STRENGTH AND SUFFICIENT TO STEER THE SHIP AT MAXIMUM SERVICE SPEED. THE CREW WAS UNABLE TO MOVE THE RUDDER AT ALL DURING THE STEERING GEAR TEST. SOLAS 60 CH II/29(a)(ii))
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 20 December 2010
Resolved
CERTIFICATES SHALL CEASE TO BE VALID IF THE CERTIFICATE IS NOT ENDORSED IN ACCORDANCE WITH THE PRESENT REGULATIONS. VSL HAS IMPROPER STATUTORY CERTIFICATES WHICH DO NOT FOLLOW STANDARD FORMAT AS REQUIRED BY SOLAS; CERTIFICATES DO NOT PROVIDE THE DATE INITIAL SURVEY WAS CONDUCTED. (74 SOLAS (2009 CONS) CH I/14.i.ii)
Construction/Loadline › Markings › Load Line Mark
Issued 20 December 2010
Resolved
ON FINDING THAT A LOAD LINE SURVEY OF A VSL UNDER THIS CHAPTER IS SATISFACTORY AND THAT THE VSL'S LOAD LINES ARE MARKED CORRECTLY, THE SECRETARY SHALL ISSUE THE VSL A LOAD LINE CERTIFICATE AND DELIVER IT TO THE OWNER, MASTER, OR INDIVIDUAL IN CHARGE OF THE VSL. THE VSL LOAD LINE MARKINGS ON THE HULL DO NOT MATCH THOSE ON THE LOAD LINE CERTIFICATE. (ILLC 66 ARTICLE 16)
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 20 December 2010
Resolved
THE EMERGENCY SOURCE OF POWER MAY BE A GENERATOR DRIVEN BY A SUITABLE PRIME MOVER WITH AN INDEPENDENT FUEL SUPPLY AND WITH STARTING ARRANGEMENTS TO THE SATISFACTION OF THE ADMINISTRATION. THE SHIP WAS UNABLE TO DEMONSTRATE THE PROPER WORKING CONDITION OF THE EMERGENCY GENERATOR (COULD NOT START THE GENERATOR AT ALL). (SOLAS 60 CH II/26(b)(iii))
Construction/Loadline › Structures › Ventilators
Issued 20 December 2010
Resolved
VENTILATOR OPENINGS SHALL BE PROVIDED WITH WEATHERTIGHT CLOSING APPLIANCES. APPROX 10 VENT COVERS ON DECK ARE WASTED, MISSING WIRE MESH COVERS, AND SEVERAL DO NOT HAVE FLOAT BALLS. ADDITIONALLY APPROX 4 CARGO HOLD VENTS ON DECK (PAINTED WHITE AND YELLOW) ARE WASTED AND NOT WATERTIGHT. (ILLC 66 ANNEX 1/19(4))
Communications › Radio Communications › EPIRB
Issued 20 December 2010
Resolved
EVERY SHIP SHALL BE EQUIPPED WITH A SATELLITE EMERGENCY POSITION-INDICATING RADIO BEACON CAPABLE OF TRANSMITTING A DISTRESS ALERT. EPIRB DOES NOT HAVE A FUNCTIONING BATTERY AND THEREFORE CANNOT TRANSMIT. (74 SOLAS (2009 CONS) CH IV/7.6.1)
Electrical › Lighting (service) › Lighting Fixture
Issued 20 December 2010
Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED THAT DANGER OF INJURY IN ORDINARY HANDLING SHALL NOT EXIST. THE SWITCH LOCATED BETWEEN THE GENERATORS IN THE ENGINE ROOM HAS EXPOSED WIRES, CREATING AN ELECTRICAL SAFETY HAZARD. ADDITIONALLY, MULTIPLE LIGHT FIXTURES HAVE BROKEN OR MISSING COVERS IN THE ENGINE ROOM, CARGO HOLD AND BUNKERING STATION ROOM. (SOLAS 60 CH II/27(a)(i)(1))
Electrical › Electrical Distribution System (service) › Panelboard
Issued 20 December 2010
Resolved
SWITCHBOARDS SHALL BE SO ARRANGED AS TO GIVE EASY ACCESS BACK AND FRONT, WITHOUT DANGER TO ATTENDANTS. SIDES, BACK, AND WHERE NECESSARY, THE FRONT OF SWITCHBOARDS SHALL BE SUITABLY GUARDED. CANNOT SECURE DOOR TO ELECTRICAL PANEL OUTSIDE OF EMERGENCY GENERATOR ROOM, DOOR CLOSED WITH ROPE. ELECTRICAL LOCKER, STBD SIDE, DOES NOT HAVE MEANS OF CLOSURE, SECURED WITH A RAG. (SOLAS 60 CH III/27(ii))
Construction/Loadline › Structures › Door
Issued 20 December 2010
Resolved
UPPER WEATHER DECK CARGO RAMP NOT WATERTIGHT, GASKET WASTED AND FLAKING OFF. HOLES IN CARGO RAMP STBD SIDE AT MIDLENGTH, AND BENT FRAMES RUBBING ON RAMP. WATERTIGHT DOORS ON FWD END OF SUPERSTRUCTURE MISSING GASKET MATERIAL AND KNIFE EDGES WASTED. PORT SIDE SHELL BUNKERING STATION DOOR NOT ABLE TO CLOSE. HINGED WATERTIGHT DOOR TO LOWER CARGO HOLD NOT ABLE TO CLOSE. DOOR BY GANGWAY UNABLE TO CLOSE.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 22 April 2009
Resolved
VESSEL IS NOT OPERATING IN ACCORDANCE WITH ISM SAFETY MANAGEMENT SYSTEM. VESSEL CAN NOT SHOW RECORDS OF REPORTS OF NON-CONFORMITIES SINCE JAN08. THE VESSEL CAN NOT PROVIDE ANY FORM OF CORRESPONDENCE BETWEEN VESSEL AND ISM COMPANY
Lifesaving › Rescue Boat › Propulsion Engine
Issued 22 April 2009
Resolved
THE VESSEL'S RESCUE BOAT WAS FOUND TO NOT HAVE AN ENGINE MOUNTED. LEAVING THE VESSEL UNABLE TO MEET THE REQUIREMENT OF BEING READILY AVAILABLE.
Engineering › Diesel Engine (auxiliary) › Nozzle, Injection (fuel injection)
Issued 22 April 2009
Resolved
#5 HIGH PRESSURE FUEL LINE HOLED AND SPRAYING FUEL.
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 22 April 2009
Resolved
COMMON RAIL FUEL PIPE HOLED AT #1 HIGH PRESSURE FUEL PUMP WITH TEMPORARY REPAIR
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 22 April 2009
Resolved
MAIN ENGINE FRESH WATER COOLER PIPE HOLED BETWEEN CYLINDER 6 & 7 WITH TEMPORARY REPAIR
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 22 April 2009
Resolved
RAW WATER SUPPLY PIPE TO ENGINE HOLED WITH TEMPORARY REPAIR
Engineering › Diesel Engine (auxiliary) › Camshaft
Issued 22 April 2009
Resolved
#2 AFT GENERATOR INOPERABLE FOR PAST 7 MONTHS
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 April 2009
Resolved
OILY WATER SEPARATOR INOPERABLE
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 22 April 2009
Resolved
HIP CAN NOT PROVIDE PROOF OF COMPLETING SAFETY INSPECTION IN ACCORDANCE WITH SAFETY MANAGEMENT MANUAL SINCE APR07 TO PRESENT
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 22 April 2009
Resolved
UPON REVIEW OF THE VSL’S SAFETY MANAGEMENT SYSTEM, COMBINED WITH THE DIRECT OBSERVATIONS AND DEFICIENCIES IDENTIFIED ABOVE, IT IS EVIDENT THAT THE VSL’S CREW HAS ENGAGED IN PRACTICES NOT IN COMPLIANCE WITH THE VSL’S SAFETY MANAGEMENT SYSTEM. IT IS RECOMMENDED THAT THE VSL’S RECOGNIZED CONDUCT AN EXTERNAL AUDIT OF THESE NON-CONFORMITIES AND PROVIDE THE U.S. COAST GUARD WITH A REPORT OF THEIR FINDIN
Personnel › Certificates/Documents/Licenses › License, Second Mate
Issued 26 January 2009
Resolved
Vessel is required to have a 2nd mate as per their Minimun Safe Manning Certificate. As per STCW 95 I/4, National license is to be endorsed by the Flag State. 2nd mate's national license is expired and has no valid flag state endorsement.
Personnel › Certificates/Documents/Licenses › License, Second Assistant Engineer
Issued 26 January 2009
Resolved
Vessel is required to have a 2nd engineer as per their Minimun Safe Manning Certificate. 2nd engineer does not have flag state endorsement.
Personnel › Certificates/Documents/Licenses › License, Second Assistant Engineer
Issued 26 January 2009
Resolved
As per STCW 95 Reg I/9. 2nd engineer does not have valid medical certificate onboard.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 26 January 2009
Resolved
VSL'S FIRE FIGHTING EQUIPMENT MUST BE READILY AVAILABLE FOR IMMEDIATE USE. ALL FIRE EXTINGUISHERS ON BOARD VESSEL ARE PAST THE SERVICING DATE. PROVIDE FLAG STATE SERVICING INTERVALS AND PROOF OF COMPLIANCE.
Personnel › Certificates/Documents/Licenses › License, Second Assistant Engineer
Issued 5 May 2008
Resolved
Observed an expired flag endorsement for 2nd Engineer. 2nd Engineer must provide a valid endorsement certificate or he must be replaced by a fully licensed 2nd Engineer.
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 8 January 2008
Resolved
Vsl required to remove oily waste from aft steering compartment.
Stability › Watertight Integrity › General
Issued 8 January 2008
Resolved
Vsl has a dime size hole in transom allowing water into aft steering compartment.
Electrical › Electric Generation Source (emergency) › Generator
Issued 17 October 2007
Resolved
Class has not approved installation of emergency generator.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 23 April 2007
Resolved
Yellow fire suit on bridge is not SOLAS approved. Does not meet marine standards
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 19 April 2007
Resolved
Emergency fire pump inoperable due to missing exhaust manifold. Form B on vessel cleared because vessel had portable pump. Vessel must still repair fixed system.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 April 2007
Resolved
OWS pipe with multiple temporary patches needs to be replaced.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 19 April 2007
Resolved
01 Extra cylinder needed for firefighting outfit on bridge.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 10 October 2006
Resolved
0669= ANTENNA OF TWO -WAY RADIO VHF RADIOTELEPHONE BROKEN. VESSEL IS REQUIRED TO HAVE ATLEAST 3 TWO-WAY RADIOTELEPHONE ONBOARD AS PER SOLAS 74 (2004) II/2.1.1
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 October 2006
Resolved
0399=VESSEL'S FWD BOSWAIN STORE BEING USED AS A PAINT LOCKER: BOSWAIN STORES NOT EQUIPPED WITH EXPLOSION PROOF LIGHT FIXTURES. VESSEL MUST REMOVE ALL PAINT FROM SPACE AND STORE IN A APPROVED PAINT LOCKER OR ASHORE. AS PER SOLAS 74 (2004) II-2/10.6.3.1
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 10 October 2006
Resolved
2545=PRIOR TO RETURN TO US, VESSEL MUST COMPLETE THE ADDITIONAL ISM/SMS VERIFICATION REQUIRED BY HINSB. THE ISM VERIFICATION MUST BE ACCEPTED BY ADMINISTRATION AS PRE SOLAS 74 (2004) IX/5
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Liner
Issued 10 October 2006
Resolved
1410=PROVIDE CLASS REPORT ATTESTING PROPER OPERATION PRIOR TO VESSEL DEPARTURE AS PER SOALS 74 (2004) II-1/26
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 10 October 2006
Resolved
COFR APPLICANT DOES NOT MATCH THE OWNER, OPERATOR OR CHARTER. PROVIDE ONBOARD A VALID COFR OR LETTER THAT TIES THE CURRENT COFR APPLICANT TO THE CURRENT REGISTERED OWNER/OPERATOR.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 20 August 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Launching Appliances › Davit
Issued 20 August 2006
Resolved
PORT LIFEBOAT NOT ABLE TO BE LOWERED. BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE.
Engineering › Bilge Water Management System › Pump
Issued 20 August 2006
Resolved
BILGE PUMP IS INOPERABLE AND NOT REPORTED AS REQUIRED BY SHIP'S SMS. SHIPS SHALL BE PROVIDED WITH AN EFFICIENT BILGE PUMPING PLANT CAPABLE OF PUMPING FROM AND DRAINING ANY WATERTIGHT COMPARTMENT. SOLAS 60 II/18(a)
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 August 2006
Resolved
OIL FILTERING EQUIPMENT IS INOPERABLE AND NOT REPORTED AS REQUIRED BY SHIP'S SMS. ANY SHIP OF 400 GT SHOULD BE FITTED WITH 15ppm OIL FILTERING EQUIPMENT.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 20 August 2006
Resolved
INSTALLED LIGHTS IN STEERING GEAR COMPARTMENT OR FWD BOSUN STORE NOT WORKING IN WAY OF EMERGENCY FIRE PUMP. LIGHTS USED FOR ILLUMINATION IN THOSE SPACES WERE PORTABLE LIGHTS WITH ELECTRICAL CORDS. ELECTRICAL CORDS HAVE ELECTRICAL TAPE IN SEVERAL PLACES. HAVE FLAG ATTEST TO SAFE OPERATION OF SPACES IN REGARDS TO LIGHTING AND ELECTRICAL SAFETY HAZARDS. PRIOR TO NEXT U.S. PORT. SOLAS 60 II/27
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 20 August 2006
Resolved
SEVERAL ACCOMMODATION SPACES AND GALLEY NOT PROVIDED WITH HOT WATER. SPACES SHALL BE REQUIRED TO PROVIDE HOT FRESH WATER IN ALL WASH SPACES. RECTIFY TO THE SATISFACTIONS OF THE ADMINISTRATION. ILO 147
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 August 2006
Resolved
DECK PLATING IN WAY OF ENGINE ROOM NOT PROPERLY SECURED. THE VESSEL SHOULD HAVE PROVISION OF SAFE MEANS OF ACCESS TO AND THROUGHOUT THE SHIP. ILO 147
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 20 August 2006
Resolved
VESSEL TO PROVIDE PROOF OF SUBMISSION OR INTERIM/FINAL APPROVAL OF NON-TANK VESSEL RESPONSE PLAN TO COAST GUARD. PRIOR TO NEXT U.S. PORT.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 20 August 2006
Resolved
VESSEL'S SOPEP ON BOARD IS NOT APPROVED BY THE ADMINISTRATION OR ANY ORGANIZATION ACTING ON BEHALF OF THE ADMINISTRATION. ANY SHIP OTHER THAN AN OIL TANKER OF 400 GT AND ABOVE SHALL CARRY ON BOARD A SHIPBOARD OIL POLLUTION EMERGENCY PLAN APPROVED BY THE ADMINISTRATION.
PRIOR TO NEXT US PORT.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 20 August 2006
Resolved
LOADLINE MARKS NOT CONSISTENT WITH LOADLINE CERTIFICATE. THE INTERNATIONAL LOAD LINE CERTIFICATE (1966) SHALL NOT BE DELIVERED TO THE SHIP UNTIL THE OFFICER OR SURVEYOR ACTING UNDER THE PROVISIONS OF ARTICLE 13 OF THE PRESENT CONVENTION HAS CERTIFIED THAT THE MARKS ARE CORRECTLY AND PERMANENTLY INDICATED ON THE SHIPS.
Deck/Cargo › Cargo Stowage › General
Issued 20 August 2006
Resolved
VEHICLES NOT STOWED IN ACCORDANCE WITH THE CARGO SECURING MANUAL IN RO-RO CARGO AREAS; CARGO SECURING MANUAL REQUIRES THAT TWO LASHINGS BE USED TO SECURE VEHICLES TO THE DECK IN THE FWD AND AFT SECTIONS OF THE VEHICLES. VESSEL ONLY USED ONE LASHING TO TIE DOWN THE FRONT OF THE VEHICLES TO THE DECK. THE AFT SECTIONS ARE SECURED TO THE VEHICLES DIRECTLY BEHIND THE FRONT VEHICLE AND NOT TO THE DECK.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 20 August 2006
Resolved
MARINE SANITATION DEVICE DOES NOT HAVE A TANK LEVEL INDICATOR.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 20 August 2006
Resolved
TOILETS WOULD NOT FLUSH. WATERCLOSETS MUST BE PROVIDED WITH AMPLE FLUSH OF WATER AVAILABLE AT ALL TIMES AND INDEPENDENTLY CONTROLLED. PRIOR TO DEPARTURE. ILO 147
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 20 August 2006
Resolved
PSCO FOUND EXPOSED WIRING ON THE WEATHER DECK IN WAY OF THE LIFEBOAT.
SOLAS 60 II/27(a)(vi)
Lifesaving › Inflatable Liferafts › Capacity
Issued 9 March 2006
Resolved
Vessel must provide 100% capacity of all persons o/b vessel (10) for both port and stbd inflatabel survival crafts. Currently, portside liferaft has capacity for 8 persons; vsl is currently set to sail with 10 pob. To be corrected prior to departure from port, to satisfaction of CG inspector.
Communications › Audible Communications › SPD (Other)
Issued 8 January 2006
Resolved
Emergency steering 2way comms in aft steering not working
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 8 January 2006
Resolved
oily waste in buckets throughout mach. space
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 8 January 2006
Resolved
excessive joil on gen. flat
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 29 November 2005
Resolved
Vessel does not have at least 2 dry docks within the past 5 years. Vessel is not permitted to conduct caro operations.
Deck/Cargo › Cargo Refrigeration › General
Issued 29 July 2005
Resolved
Vehicles on main deck not stowed in accordance with cargo securing manual. Properly stow vehicles.
Deck/Cargo › Cargo Stowage › General
Issued 29 July 2005
Resolved
Cargo stowed in main Ro/Ro hold not secured. All mattresses, buckets, tires ect.. must be secured so as to prevent blocking the only path to the emergency generator if cargo shifts.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 29 July 2005
Resolved
Smoke was found by CG Inspectors in engine room. Cause of smoke unknown, but main generator only machine operating at time. Deteremine cause of smoke and correct.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 18 July 2005
Resolved
Paint locker CO2 system nozzles are only located by the door and may not provide protection to the entire space. Have flag state representative attest to proper arrangement.
Lifesaving › Launching Appliances › Davit
Issued 18 July 2005
Resolved
Port side deck and davit support are wasted. The deck under the davit support is wood. The wood is rotting and the steel under the wood is wasted.
Construction/Loadline › Penetrations › Gasket
Issued 18 July 2005
Resolved
Both cargo ramp gaskets are wasted and leaking. Ship used expandable foam as a temporary fix to prevent leaking.
Accommodation/Occupational Safety › Messroom › Location
Issued 18 July 2005
Resolved
Vessel's galley and food stores are infested with roaches. Provide receipt from extermination company.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 18 July 2005
Resolved
Vessel has excessive oil in the bilge. Provide reciept for discharge.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 18 July 2005
Resolved
SOLAS Safety Equipment Cert. expired July, 16, 2005.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 18 July 2005
Resolved
Vessel as not logged non-conformities as required by ISM. Log all existing non-conformities.
Engineering › Bilge Water Management System › Piping
Issued 18 July 2005
Resolved
Bilge piping under shaft turning gear holed. Make proper repairs.
Engineering › Diesel Engine (auxiliary) › Charge Air Cooling
Issued 18 July 2005
Resolved
Raw water cooling line to aft generator in split.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 18 July 2005
Resolved
Remove all flammables improperly stored in forward compartment. Store all flammables in an approved space.
Electrical › Electrical Distribution System (emergency) › Cable
Issued 18 July 2005
Resolved
Emergency generator batteries are missing covers. Provide covers.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 18 July 2005
Resolved
Emergency generator fuel oil tank is empty. Maintain required fuel for emergency operations.
Lifesaving › Rocket Parachute Flares › General
Issued 18 July 2005
Resolved
Vessel does not have required amount of distress flares on bridge.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 18 July 2005
Resolved
Vessel does not ave required amount of line throwing apparatus onboard (missing one).
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 June 2005
Resolved
Remove electrical cable from open 380 volt power panel in engine room leading to air compressor and install power cable correctly.
Engineering › Freshwater System (cylinder head cooling) › Valve
Issued 8 June 2005
Resolved
Vsl experienced a problem with the cylinder head while departing the Port of Miami on 07 June 05. The vsl returned to its original berth on the Miami River to repair the problem. A report will be sent to this office once the repairs have been done and prior to the vsl departing.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 June 2005
Resolved
Have flag attest to the integrity of 380 vt power panels in engine room. Panels wired open and have ventilation routed over them to cool. verify that panels are not overheating.
Deck/Cargo › Cargo Stowage › General
Issued 25 May 2005
Resolved
Numerous vechiles have been loaded with more than 1/4 tank of gas, batteries connected and keys in ignition. Remove al cargo and load IAW 49CFR176.905
Electrical › Lighting (service) › Lighting Fixture
Issued 14 February 2005
Resolved
Numerous lighting fixtures in cargo hold are missing covers and light bulbs causing an electrical fire hazard with the cargo.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 14 February 2005
Resolved
Vsl's second officer and Chief mate are missing there STCW flag state endorsements.
Deck/Cargo › Cargo Stowage › General
Issued 14 February 2005
Resolved
Vehicles found onboard Vsl with fuel in tanks of the motor vehicles above a querter of a tank. There is no fixed fire fighting system nor explosion proof lighting.
Construction/Loadline › Structures › Superstructure
Issued 14 February 2005
Resolved
All exterior windows into cabins have window type AC units. Windows are not able to properly secure for weather tight integrity.
Construction/Loadline › Structures › Deck Plating
Issued 14 February 2005
Resolved
The deck of the second mates cabin is wasted and holed.
Construction/Loadline › Structures › Deck Plating
Issued 14 February 2005
Resolved
The deck under the sink in the galley is wasted and worn.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 August 2004
Resolved
Remove or properly repair the following electrical hazards: Improper splice on outboard side of #2 generator, deadend wire IWO #3 switchboard (overhead), unprotected light penetrating deck plates of bildge space in engine room and improper splices IWO steering gear post. SOLAS 60 Reg 27(a)
Engineering › Steering Gear System › Actuator
Issued 7 August 2004
Resolved
Prove proper operation of the main steering gear from within the steering gear compartment. Auxiliary steering gear is not operational. SOLAS 60 Reg29(a)(iii)
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 August 2004
Resolved
Prove proper operation of oil sample disply (meter) on oily-water separaating equipment.
Engineering › Bilge Water Management System
Issued 7 June 2004
Resolved
Have accumulated oily waste in bilges pump out from the fore peak area. Provide receipts as evidence of offloading transfer from an approved reception facilty to MSO Miami. Prior to conducting cargo operations. LEGACY COMPONENT DESC: Piping
Construction/Loadline › Structures
Issued 7 June 2004
Resolved
Have class address bilge system condition, below deck cargo holds aft area, fuel tank/piping in the forepeak area, forward below deck piping on both sides and overall below deck condition. Provide report from Class Surveyor to this office. All items are not inclusive. LEGACY COMPONENT DESC: Overall bulkhead and piping below deck
Personnel › Certificates/Documents/Licenses
Issued 27 January 2004
Resolved
Provide endorsements for 2nd deck/engineer officers, IAW STCW 95, via fax to USCG. LEGACY COMPONENT DESC: STCW Endorsement
Fire Fighting › Fire Main
Issued 10 July 2003
Resolved
Doubler plate on fire main piping in cargo hold between frames 58 & 59 near overhead. Properly and permanently repair piping. LEGACY COMPONENT DESC: Condition
Electrical › Electrical Distribution System (service)
Issued 10 July 2003
Resolved
Dead-end cable in overhead in cargo hold near emergency generator. LEGACY COMPONENT DESC: Wiring
Documentation › Certificates/Documents
Issued 10 July 2003
Resolved
Provide valid Safety Radio Certificate. LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Personnel › Manning/Qualifications
Issued 29 May 2003
Resolved
A/B (Mercedez Diaz) dioes not have valid medical certificate. Provide valid medical certificate for A/B. LEGACY COMPONENT DESC: Medical Fitness
Electrical › Lighting (service)
Issued 29 May 2003
Resolved
Light fixture in steering flat is missing cover. Provide cover for light fixture. LEGACY COMPONENT DESC: Lighting Fixture
Electrical › Electrical Distribution System (service)
Issued 29 May 2003
Resolved
Back sise of switchboard is missing panel/cover. Provide cover for exposed back side of switchboard. LEGACY COMPONENT DESC: Switchboard
Stability › Watertight Integrity
Issued 29 May 2003
Resolved
Ramp in cargo hold is severely leaking from the weather deck. Have flag state provide report of recommended repairs and attestation of such repairs.
Stability › Water on Deck
Issued 29 May 2003
Resolved
Four inch hole located on deck of focsle, just starboard and aft of chain box. Have class attest to permanent/proper repairs of hole.
Construction/Loadline › Markings
Issued 19 November 2002
Resolved
Permanently mark on both sides the load line markings IAW the Int'l Conference on load lines,1966 and Load line certificate. LEGACY COMPONENT DESC: Load Line Mark
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 19 November 2002
Resolved
Permanently mount fire extinguisher IWO main deck at enterence to engine room. LEGACY COMPONENT DESC: Mounting Bracket
Lifesaving › Lifebuoys
Issued 19 November 2002
Resolved
Replace lifebuoy IWO rescue boat.
Personnel › Manning/Qualifications
Issued 23 May 2002
Resolved
Provide manning in accordance with vessel's Minimum Safe Manning Document. LEGACY COMPONENT DESC: Minimum Safe Manning
Documentation › Safety/Response Plans/Programs
Issued 23 May 2002
Resolved
Update Fire Control Plan with proper IMO symbology. LEGACY COMPONENT DESC: Fire Control Plans
Operations/Management › Navigation Safety
Issued 23 May 2002
Resolved
Commence logging of Pre-arrival tests in accordance with 33 CFR 164.25. LEGACY COMPONENT DESC: Arrival/Departure Tests
Lifesaving › Lifeboat
Issued 23 May 2002
Resolved
Replace, as needed, retro-reflective tape on starboard lifeboat. LEGACY COMPONENT DESC: Markings
Lifesaving › Inflatable Liferafts
Issued 23 May 2002
Resolved
Provide onboard two liferafts with servicing certificates.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 May 2002
Resolved
Remove motor oil drums from CO2/Emergency generator room.
Engineering › Steering Gear System
Issued 23 May 2002
Resolved
Provide block diagram of steering gear on bridge and in steering gear room as per SOLAS V/19-2(c)(i).
Electrical › Electrical Distribution System (service)
Issued 23 May 2002
Resolved
Provide panels for back side of Main Switchboard. LEGACY COMPONENT DESC: Panelboard
Accommodation/Occupational Safety › Occupational Safety
Issued 23 May 2002
Resolved
Replace deck grating in front of Main Switchboard. LEGACY COMPONENT DESC: deck grating
Electrical › Electrical Distribution System (service)
Issued 23 May 2002
Resolved
Provide non-conductive mat to cover full area in front of main switchboard. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Navigation › Piloting/Steering
Issued 23 May 2002
Resolved
Provide new compass deviation table that does not referance gyro compass since vessel does not have operable gyro. LEGACY COMPONENT DESC: Deviation Table/Graph
Accommodation/Occupational Safety › Occupational Safety
Issued 23 May 2002
Resolved
Remove paint cans blocking passage on boat deck aft.
Lifesaving › Lifebuoys
Issued 23 May 2002
Resolved
Replace lifebuoy in way of pilot boarding area.
Operations/Management › Drills/Instruction
Issued 23 May 2002
Resolved
Conduct Fire drill in presence of USCG Inspector. LEGACY COMPONENT DESC: Fire
Operations/Management › Drills/Instruction
Issued 23 May 2002
Resolved
Conduct abandon ship drill in presence of USCG inspector. LEGACY COMPONENT DESC: Abandon Ship
Deck/Cargo › Cargo Stowage
Issued 23 May 2002
Resolved
Remove cargo from cargo hold IAW of stbd reefer generator, from blocking access to fire fighting equipment. Removed cargo stowed IAW of cargo hatch winch space.
Fire Fighting
Issued 29 June 2001
Resolved
Provide fix sprinkler system for cargo hold (vehicles shipped as hazmat) IAW 49 CFR 176, prior to loading vehicles on it.
Documentation
Issued 29 June 2001
Resolved
Provide shipping papers and dangerous cargo manifest IAW 49 CFR for all cargo being shipped as HAZMAT prior to departure.
Documentation
Issued 29 June 2001
Resolved
Proivide HAZMAT training for the Master of the vessel prior to loading any hazmat.
Documentation
Issued 29 June 2001
Resolved
Provide safe manning certificate for vessel's route prior to departure.
Documentation
Issued 29 June 2001
Resolved
Provide GMDSS licenses for deck officers in charge of a watch.
Documentation
Issued 29 June 2001
Resolved
Correct all deficiencies issued by MSO Tampa prior to departure.
Documentation
Issued 29 June 2001
Resolved
Vessel is to have adequate number of licensed officers for trading route.
Documentation
Issued 29 June 2001
Resolved
Prior to departure vessel must provide a surveyor's report addressing all outstanding deficiencies and must undergo a re-examination by MSO Miami personnel.
Documentation
Issued 29 June 2001
Resolved
Provide safety equipment certificate that reflects the equipment on board and provide all equipment required by it prior to departure.
Lifesaving
Issued 18 May 2001
Resolved
MAKE PREMINATE REPAIRS TO BOTH LIFEBOAT DAVIT FOUNDATIONS.
Lifesaving
Issued 18 May 2001
Resolved
PERFORM SATISFACTORY ABANDON SHIP DRILL IN PRESENCE OF USCG INSPECTOR.
Lifesaving
Issued 18 May 2001
Resolved
MAKE PROPER REPAIRS TO COUPLING SYSTEM FOR LIFEBOAT WENCH SYSTEM ON PORT SIDE.
Construction/Loadline
Issued 18 May 2001
Resolved
REPLACE MANHOLE COVER FROM COMPARTMENT IN AFT SEERING.
Construction/Loadline
Issued 18 May 2001
Resolved
REPAIR IN KIND LARGE MANHOLE COVER 3RD RO/RO DECK PORT SIDE AFT.
Lifesaving
Issued 18 May 2001
Resolved
SERVICE ALL LIFERAFTS
Accommodation/Occupational Safety
Issued 18 May 2001
Resolved
INSTALL GALLEY WATERTIGHT WINDOW.
Documentation
Issued 18 May 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 18 May 2001
Resolved
PROVIDE A TOTAL OF 12 PARACHUTE FLARES FOR THE BRIDGE.
Lifesaving
Issued 18 May 2001
Resolved
PROVIDE SMOKE FLOAT FOR PORT SIDE LIFEBOAT.
Lifesaving
Issued 18 May 2001
Resolved
PROVIDE LADDER FOR BOTH LIFEBOATS.
Lifesaving
Issued 18 May 2001
Resolved
PROVIDE WATER FOR LIFEBOATS.
Electrical
Issued 18 May 2001
Resolved
INSTALL EXPLOSION PROOF LIGHTING ON RAMP TO #3.
Navigation
Issued 18 May 2001
Resolved
PROVIDE PERMANENT COMMUNICATIONS BETWEEN STEERING ROOM AND BRIDGE.
Fire Fighting
Issued 18 May 2001
Resolved
PROVIDE PROPER OPERATION OF EMERGENCY FIRE PUMP.
Accommodation/Occupational Safety
Issued 18 May 2001
Resolved
ENSURE ALL ACCOMODATION LIGHTING IS PROPERLY COVERED AND IN GOOD WORKING CONDITION.
Construction/Loadline
Issued 18 May 2001
Resolved
IWO RAMP LEAKING TO #2 RO-RO DECK AT FRAME #6 THE TOP BRACKET IS TRIPED.
Electrical
Issued 18 May 2001
Resolved
REMOVE WIRE ON TOP OF RECTIFIER LOCATED ON THE BRIDGE DECK.
Construction/Loadline
Issued 18 May 2001
Resolved
MAKE NECESSARY REPAIRS TO CROP AND RENEW WASTED AREAS AROUND HOUSE.
Electrical
Issued 18 May 2001
Resolved
SECURE BATTERY IN CO2 ROOM AND REPLACE CAP ON THE BATTERY.
Electrical
Issued 18 May 2001
Resolved
ENSURE THAT ALL ELECTRICAL CONNECTION BOXES AND CABLES ARE MADE EXPLOSION PROOF ON RO/RO DECKS IN WORK 380/220 VOLT TRANSFORMER AND PROVIDE CLASS REPORT ON SAME.
Engineering
Issued 11 January 2001
Resolved
PRIOR TO NEXT U.S. PORT CALL, REPAIR OILY WATER SEPARATER ALARM AND PROVIDECLASS REPORT OF SAME.
Electrical
Issued 11 January 2001
Resolved
PRIOR TO NEXT U.S. PORT CALL, REPAIR/ REPLACE ALL FIXTURES ON RO/RO DECKS TO ENSURE EXPLOSION PROOF STATUS.
Navigation
Issued 11 January 2001
Resolved
PRIOR TO NEXT U.S. PORT CALL, PROVIDE LOG ENTRIES OF PRE-ARRIVAL TESTS AS PER SOLAS 74.
Fire Fighting
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, REPLACE WITH A NEWLY RECHARGED ABC FIRE EXTINGUISHER LOCATED ON LOWEST RO/RO DECK AS PER SOLAS 74 CH II-2/6.5.
Documentation
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVIDE A GARBAGE LOG AS PER MARPOL 74/78 AND 33 CFR 151.65.
Fire Fighting
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVE PROPER OPERATION OF MAIN FIRE PUMP.
Construction/Loadline
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVE PROPER OPERATION OF BILGE PUMP.
Lifesaving
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVIDE SMOKE SIGNAL CANISTERS IN EACH LIFEBOAT AS PER SOLAS 60 CH III REG II(XV).
Lifesaving
Issued 11 January 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVIDE OIL RECORD BOOK AS PER 33 CFR 151.25.
Documentation
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVIDE SHIPBOARD OIL POLLUTION EMERGENCY PLAN(SOPEP) AS PER 33 CFR 151.26. VESSEL HAD STAMPED AND DATED LETTER APPROVING THE VESSEL'S SOPEP, BUT MISSING ACTUAL PLAN.
Lifesaving
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVIDE CURRENT LINE-THROWING APPARATUS. ORIGINAL HAVEEXPIRED.
Lifesaving
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVIDE CORRECT NUMBER OF ROCKET FLARES ON BRIDGE AS PER SOLAS 60 CH III REG 24.
Lifesaving
Issued 11 January 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, REPLACE STARBOARD RING BUOY LIGHT ON BRIDGE DECK NEAR LIFEBOAT AS PER SOLAS 74 CH III/7.
Accommodation/Occupational Safety
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVIDE ADEQUATE FOOD SUPPLY FOR VOYAGE AS PER ILO 147.
Fire Fighting
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVE PROPER OPERATION OF FIXED FIRE DETECTION AS PER SOLAS 74 CH II-2/53.2.1.
Lifesaving
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, CONDUCT SATISFACTORY FIRE AND ABANDON SHIP DRILLS.
Navigation
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVIDE EMERGENCY/OPERATING INSTRUCTIONS FOR STEERING AS PER 33 CFR 164.35.
Navigation
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVIDE AUXILIARY STEERING PUMP FOR STEERING ROOM AS PER SOLAS 74 CH II-1/29.
Electrical
Issued 11 January 2001
Resolved
PRIOR TO 11FEB01, REPAIR/REPLACE LIGHTS IN STEERING ROOM AS PER SOLAS 74 CHII-1/45.1.
Navigation
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVIDE LOSS OF POWER ALARM TO BRIDGE FOR STEERING MOTOR AS PER SOLAS 74 CH II-2/29.
Navigation
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVIDE FIXED COMMUNICATIONS BETWEEN STEERING ROOM AND BRIDGE AS PER SOLAS 74 CH II-1/29.
Navigation
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVE PROPER OPERATION OF EMERGENCY STEERING AS PER SOLAS 60 CH II REG 29a(i).
Construction/Loadline
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, POST PROHIBITION OF OIL DISCHAGE PLACARDS THROUGHOUT ENGINE ROOM AS PER 33 CFR 154.
Engineering
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVE PROPER OPERATION OF OILY WATER SEPARATOR AS PER MARPOL 74/78.
Fire Fighting
Issued 11 January 2001
Resolved
PRIOR TO DEPARTURE, PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.