MAURY USCG vessel records Sign in
← All vessels

ATLANTIC LEVANTIA

ATLANTIC LEVANTIA is a 1999 tank ship. The Coast Guard has recorded 20 inspections since 2004, most recently in January 2012, along with 8 deficiencies and 6 operational controls.

Records from 2004 to 2012. Most recent: inspection, 4 January 2012.

Built
1999
Last inspected
4 January 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9192777 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
509169
Flag
LIBERIA
—
Maury page id
psix-509169

Inspections, by type

…with no type recorded7
Years with a record 8 calendar years (2004–2012)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23843 - Simplified, Gross Ton
23843 - Convention (Subpart B), Gross Ton
8835 - Simplified, Net Ton
8835 - Convention (Subpart B), Net Ton
35928 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

4 January 2012 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4215715
25 August 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4126899
2 December 2010 ISPS II Exam · COC-CHEM Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3900580
9 March 2009 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3428859
25 February 2009 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3423989
14 February 2009 COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3416734
26 December 2008 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3385035
3 June 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2669034
22 May 2006 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2653155
30 September 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2504791
29 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2504358
3 July 2005 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2412453
29 June 2005 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2407748
29 June 2005 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2407773
16 June 2005 ISPS I Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2392853
15 June 2005 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2392884
11 June 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2386996
11 April 2005 MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · COC-TVE Annual
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2331155
19 February 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2009375
18 February 2004 Certificate of Compliance · MTSA/ISPS Verification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2006773

Deficiency record · 8

Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 4 January 2012 Resolved
0730 - Carbon dioxide controls shall be inside a release box. The release control cabinet for the engine room located inside the CO2 room is broken and hanging on by line attached to the copper lines above the cabinet. FSS Code 5/2.2.2.2. 17a
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2012
Resolved 5 January 2012
Resolution: Class attended vessel and approved temporary repairs allowing until 16Feb2012 for permanent repair.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 4 January 2012 Resolved
1740 - ODME automatic monitoring and control system unit shall be made operable as soon as possible. The ODME is not operable in automatic mode. MARPOL Annex I Reg. 31.2. 17a
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2012
Resolved 5 January 2012
Resolution: Class attended vessel and cleared the discrepancy.
Lifesaving › Lifeboat › Propulsion Casing/Protection
Issued 2 December 2010 Resolved
0610 - Lifeboats - The external cutless bearing to the starboard lifeboat's propeller and shaft arrangement will not remain in place, causing excessive vibration to the shaft and propeller. The lifeboat propulsion arrangement must be designed to withstand damage by floating debris. SOLAS 2004 (cons Ed) Ch III Reg 20.2 LSA Code 4.4.6.7 Action 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2010
Resolved 3 December 2010
Resolution: Sec Delaware Bay inspected and reported repaired.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 2 December 2010 Resolved
1099 - Other Alarms - Each cargo tank of a tankship must be equipped with a tank overfill alarm and be visible on cargo deck. Vessel's overfill alarm is not visible from cargo deck area. Flicker light is inoperable. Alarm light must be repaired prior to loading cargo. 46CFR39.20-7(d)(2) Action 15c
Action required: 15 - Rectify deficiencies by next port
Due 6 December 2010
Resolved 3 December 2010
Resolution: Sec. Delaware Bay inspected and reported repaired.
Engineering › Fuel Oil Service System › Piping
Issued 2 December 2010 Resolved
0710 - Fire Prevention - Provisions shall be made to facilitate cleaning, inspection, and maintenance of main propulsion and auxiliary machinery. The purifier room has excessive oil under and around purifiers. The first purifier when entering the purifier room has a catch-can placed underneath to catch leaking fuel oil. SOLAS 04(con ed) Ch II-1 Reg 26.7 Action 70c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 December 2010
Resolved 25 August 2011
Resolution: Received proper documentation from the vessel''s captain satisfying the requirement.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 26 December 2008 Resolved
Span gas was not onboard as required as per Chapter 13.2.1 of the IBC CODE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 7 January 2009
Resolution: On 07JAN09, Sector received invoice attesting to the purchase and delivery of the span gas.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 11 April 2005 Resolved
Mark vapor control piping in accordance with regulations.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 June 2005
Resolution: Vapor control piping has been marked IAW regs.
Navigation › Collision/Grounding Avoidance
Issued 17 February 2004 Resolved
Vessel was granted letter of deviation to enter the Port of Corpus Christi without a properly operating echo depth sounder. 33 CFR 164.35(a) LEGACY COMPONENT DESC: Echo-sounding Device
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2004
Resolution: Vessel''s agent faxed copy of technicians report attesting to repairs.