Records from 2016 to 2026. Most recent: inspection, 18 March 2026.
Inspection history · 9
18 March 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8328087
27 June 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8168931
22 May 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8132579
2 April 2025
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8097212
6 February 2025
PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8071942
2 September 2020
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7044004
18 July 2020
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7001773
17 April 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6126367
27 June 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5921154
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 February 2025
Resolved
The following basic principles underlie the regulations in the chapter and are embodied in the regulations as appropriate, having regard to the type of ships and the potential fire hazard involved:...protection of means of escape or access for fire fighting. PSCO observed wing-nut release for escape trunk from engine room was seized, preventing means of escape.
74 SOLAS 2001 II-2/2.2.6
17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2025
Resolved 6 February 2025
Resolution: Deficiency was cleared after crew greased wing nut to restore proper function.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 February 2025
Resolved
Fire doors in main vertical zones bulkheads, galley boundaries and stairway enclosures, other than power-operated watertight doors and those which are normally locked, shall satisfy the following requirements: the doors shall be self-closing and be capable of closure against an angle of inclination of up to 3.5 degrees opposing closure. PSCO observed A-0 fire door in main stairway inncapable of closing, on its own.
74 SOLAS 2001 II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 February 2025
Resolved 6 February 2025
Resolution: Crew adjusted door actuator to enable door to fully seat against door frame.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 2 September 2020
Resolved
A food ration as described in paragraph 4.1.5.1.18 totalling not less than 10,000 kj for each person the lifeboat is permitted to accomodate these rations shall be kept in airtight packaging and be stowed in a watertight container. Four of the fourty-six required lifeboat food rations lost their vacuum seal. SOLAS 2014 CH III Sec IV Reg 34 ISA CH IV 4.4.8.12
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 September 2020
Resolution: Vessel received new emergency food rations and provided photo and receipt.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 18 July 2020
Resolved
Every oil fuel pipe, which, if damaged would allow oil to escape from a storage tank shall be fitted with a cock or valve directly on the tank capable of being closed from a safe postion outside the space in the event of a fire. There were wood blocks observed that would prevent the valve from operating.
74 SOLAS II-2/Reg. 15.2.5
Action required: 10 - Deficiency Rectified
Resolved 18 July 2020
Resolution: Crew removed wood block.
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 27 June 2016
Resolved
74SOLAS(14)IX/3.1 ISM CODE PART A/10.1 THE PSCO DISCOVERED BOTH PORT AND STARBOARD LIFEBOATS WERE SHORT 15.5L OF WATER, AS SHIPS 75 500ML WATER PACKETS ONLY AMOUNT TO 37.5L. COMPANY SMS LIFESAVING TRAINING MANUAL ONLY REQUIRES THE 75 WATER PACKETS, BUT DOES NOT PROPERLY INDICATE HOW REMAINING WATER MUST BE SUPPLIED TO SHIP, CREW TEMPORARILY USING BINS. 50B
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 6 July 2016
Resolution: Reviewed safety training manual, ch. 3, with proper water ration capacity for each lifeboat - ship temporarily using water bins for proper water rations, company sending additional water packets to ship. Chief officer further trained with lifesaving SMS.
Fire Fighting › Structural - A Class Divisions › Open Deck Spaces
Issued 27 June 2016
Resolved
74SOLAS(2001CONS.)II-2/9.3.1 WHERE A CLASS DIVISIONS ARE PENETRATED, SUCH PENETRATIONS SHALL BE SUITABLY INSULATED BY EXTENSION OF SAME LEVEL OF DIVISION. PSCO DISCOVERED NUMEROUS SECTIONS OF INSULATION MISSING SURROUNDING ELECTRICAL WIRING IN "A" CLASS FIRE DIVISION OF FOLLOWING SPACES: E DECK AND UPPER DECK ELECTRICAL CABLE TRUNK. 10C
Action required: 705 - Other - as specified
Due 27 June 2016
Resolved 27 June 2016
Resolution: CORRECTED ON THE SPOT. FILLED OPEN SPACES.