MAURY USCG vessel records Sign in
← All vessels

ISMAEL

ISMAEL is a freight ship. The Coast Guard has recorded 15 inspections since 2000, most recently in February 2024, along with 76 deficiencies and 6 operational controls.

Records from 2000 to 2024. Most recent: inspection, 29 February 2024.

Built
Not recorded
Last inspected
29 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5411137 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
CPB625
509350
Flag
BOLIVIA
—
Maury page id
psix-509350

Inspections, by type

…with no type recorded10
Years with a record 6 calendar years (2000–2024)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it747 - Convention (Subpart B), Gross Ton
423 - Regulatory (Subpart C or D), Gross Ton
441 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

29 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7872331
8 September 2016 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5995538
11 March 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1755921
20 September 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1686001
10 May 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1615272
14 January 2002 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1478794
10 January 2002 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1477491
27 December 2001 Examination of Repairs · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1474342
2 March 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 638082
26 February 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 287579
21 February 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 106861
14 February 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 287181
19 August 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 281207
12 June 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 638081
4 June 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 535704

Deficiency record · 76

Pollution Prevention/Response › Prevention Equipment
Issued 10 May 2002 Resolved
Prove proper operation of the OWS prior to next U.S. Port call. Vsl is not to use the OWS. LEGACY COMPONENT DESC: Oily Water Separator (100 ppm)
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 29 February 2024
Resolution: 29FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2002. vessel returned several times and had numerous insp after. From activity: 1615272
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 10 May 2002 Resolved
Provide medical certificates for Chief Engineer and Oiler proor to next U.S. Port call.
Action required: 705 - Other - as specified
Resolved 29 February 2024
Resolution: 29FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2002. vessel returned several times and had numerous insp after. From activity: 1615272
Pollution Prevention/Response › Prevention Equipment
Issued 10 May 2002 Resolved
Remove excess waste oil from Bilge to an approved shore side facility. Provide receipt to the MSO. LEGACY COMPONENT DESC: Bilge Monitor
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2002
Resolution: Copy of receipt for the removal of 1400 gals of oil water provided to office.
Pollution Prevention/Response › Prevention Equipment › Internal Cargo Transfer Capability
Issued 10 May 2002 Resolved
Retain all oily waste water within vsl. Ensure that Oil Record Book coinsides with xfer of oil wastewater.
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 29 February 2024
Resolution: 29FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2002. vessel returned several times and had numerous insp after. From activity: 1615272
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 May 2002 Resolved
Replace retro-reflective tape for ringbuoy on starboard side fwd.
Action required: 705 - Other - as specified
Due 30 May 2002
Resolved 29 February 2024
Resolution: 29FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2002. vessel returned several times and had numerous insp after. From activity: 1615272
Pollution Prevention/Response › Prevention Equipment
Issued 5 February 2002 Resolved
Person in charge was not immediately available during critical stages(Topping off) of transfer of diesel fuel.
Action required: 703 - Prior to bunkering operations
Resolved 28 March 2002
Pollution Prevention/Response › Prevention Equipment
Issued 5 February 2002 Resolved
Four persons required for transfer operations as posted on transfer procedures. only three persons were performing operations.
Action required: 703 - Prior to bunkering operations
Resolved 28 March 2002
Pollution Prevention/Response › Prevention Equipment
Issued 5 February 2002 Resolved
No declaration of inspection was on board and available for inspection.
Action required: 703 - Prior to bunkering operations
Resolved 28 March 2002
Pollution Prevention/Response
Issued 5 February 2002 Resolved
The transfer was performed through an open fuel tank access plate and not through a fixed connection or fill pipe as required.
Action required: 703 - Prior to bunkering operations
Resolved 28 March 2002
Pollution Prevention/Response › Prevention Equipment
Issued 5 February 2002 Resolved
Drains to fixed containment were open and not plugged as required. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Action required: 703 - Prior to bunkering operations
Resolved 28 March 2002
Deck/Cargo › Ballast
Issued 14 January 2002 Resolved
PERFORM PERMANENT REPAIRS TO WASTED BALLAST PIPING LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2002
Resolved 28 March 2002
Deck/Cargo › Ballast
Issued 14 January 2002 Resolved
SEGREGATE BALLAST TANK WITH WATERTIGHT BULKHEAD IN ACCORDANCE WITH CALCULATED STABILITY MANUAL LEGACY COMPONENT DESC: Segregated Ballast Tank
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2002
Resolved 28 March 2002
Pollution Prevention/Response › Prevention Equipment
Issued 14 January 2002 Resolved
ELIMINATE POSSIBILITY FOR SEWAGE TO DISCHARGE THROUGH BALLAST SYSTEM LEGACY COMPONENT DESC: Sewage System Piping
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2002
Resolved 28 March 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 14 January 2002 Resolved
ELIMINATE POSSIBILITY FOR FUEL DISHARGE OVERBOARD THROUGH BALLAST SYSTEM LEGACY COMPONENT DESC: Piping
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2002
Resolved 28 March 2002
Operations/Management › Pollution
Issued 14 January 2002 Resolved
IMMEDIATELY REMOVE STANDING OIL ON DECKS LEGACY COMPONENT DESC: Control of Discharge of Oil
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2002
Resolved 28 March 2002
Operations/Management › Pollution
Issued 14 January 2002 Resolved
IMMEDIATELY COVER AND STORE OPEN BARRELS OF OIL LEGACY COMPONENT DESC: Control of Discharge of Oil
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2002
Resolved 14 January 2002
Pollution Prevention/Response › Prevention Equipment
Issued 14 January 2002 Resolved
IOPP Certificate indicates that no standard discharge connection was on board the vesses as required, when asked about the standard discharge connection chief engineer stated that none was on board. LEGACY COMPONENT DESC: Standard Discharge Connection
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Pollution Prevention/Response › Prevention Equipment
Issued 14 January 2002 Resolved
OWS piping was found not properly piped to allow proper operation of OWS. chief engineer stated that oily mixtures were placed in ballast tanks due to the condition of OWS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 15 - Rectify deficiencies by next port
Due 8 September 2016
Resolved 8 September 2016
Pollution Prevention/Response › Prevention Equipment
Issued 14 January 2002 Resolved
Oily residues were contained in ballast tanks.
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Pollution Prevention/Response › Prevention Equipment
Issued 14 January 2002 Resolved
Overboard valve from MSD was not secured as required. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 28 March 2002
Pollution Prevention/Response
Issued 5 January 2002 Resolved
Vessel entered the Port of Canaveral and docked at a terminal that did not hold the proper Certificate of Adequacy for the vessel.
Action required: 705 - Other - as specified
Resolved 28 March 2002
Accommodation/Occupational Safety › Washroom/Toilet
Issued 27 December 2001 Resolved
Repair non-operating toilet and replace missing wash basin in crew head. LEGACY COMPONENT DESC: Number Per Persons
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 March 2002
Fire Fighting › Fire Hoses
Issued 27 December 2001 Resolved
Replace missing couplings on fire hoses. LEGACY COMPONENT DESC: Connections
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 March 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 27 December 2001 Resolved
Fixed firefighting piping in emergency generator space was found wasted. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 March 2002
Personnel › Manning/Qualifications
Issued 27 December 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 28 March 2002
Lifesaving › Rescue Boat
Issued 27 December 2001 Resolved
Engine was inoperable. LEGACY COMPONENT DESC: Propulsion Engine
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 28 March 2002
Documentation › Certificates/Documents
Issued 27 December 2001 Resolved
WITHDRAWN LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Action required: 705 - Other - as specified
Resolved 28 March 2002
Documentation › Certificates/Documents
Issued 27 December 2001 Resolved
WITHDRAWN LEGACY COMPONENT DESC: International Load Line Certificate
Action required: 705 - Other - as specified
Resolved 28 March 2002
Documentation › Certificates/Documents
Issued 27 December 2001 Resolved
WITHDRAWN LEGACY COMPONENT DESC: International Tonnage Certificate
Action required: 705 - Other - as specified
Resolved 28 March 2002
Documentation › Certificates/Documents
Issued 27 December 2001 Resolved
WITHDRAWN LEGACY COMPONENT DESC: IOPP Certificate
Action required: 705 - Other - as specified
Resolved 28 March 2002
Documentation › Certificates/Documents
Issued 27 December 2001 Resolved
WITHDRAWN LEGACY COMPONENT DESC: Cargo Ship Safety Certificate
Action required: 705 - Other - as specified
Resolved 27 December 2001
Operations/Management › Port and Waterways Safety
Issued 27 December 2001 Resolved
Vessel failed to provide required notice of arrival. LEGACY COMPONENT DESC: Notice of Arrival, General
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 28 March 2002
Electrical › Electric Generation Source (service)
Issued 27 December 2001 Resolved
Main Generator was found inoperable. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 December 2001 Resolved
Electrical distribution panel in passageway was found not attached properly. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 December 2001 Resolved
Distribution panels throughout the vessel were found in poor condition, inadequate wiring, improper wiring, missing switches, improper closures. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 March 2002
Construction/Loadline › Hull
Issued 27 December 2001 Resolved
Hull thickness in engine room was found in poor condition, water was observed weeping throught hull. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 March 2002
Construction/Loadline › Hull
Issued 27 December 2001 Resolved
Longitudinal frames were found bent in emergency generators space and paint locker. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 28 March 2002
Lifesaving › Inflatable Liferafts
Issued 27 December 2001 Resolved
Both Liferafts and Hydrostatic releases exceeded the service dates. LEGACY COMPONENT DESC: Carriage Requirement
Action required: 705 - Other - as specified
Resolved 28 March 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 27 December 2001 Resolved
PFD'S were missing personal marker lights. LEGACY COMPONENT DESC: Lights
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 28 March 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 27 December 2001 Resolved
CO2 tank for fixed fire system in paint locker was found empty. LEGACY COMPONENT DESC: Quantity of CO2
Action required: 705 - Other - as specified
Resolved 28 March 2002
Fire Fighting › Emergency Fire Pumps
Issued 27 December 2001 Resolved
Emergency Fire Pump had inadequate pressure. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 March 2002
Lifesaving › Lifejacket/PFD (Type V)
Issued 27 December 2001 Resolved
Lights on ring bouys were inoperable. LEGACY COMPONENT DESC: Lights
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 28 March 2002
Accommodation/Occupational Safety
Issued 27 December 2001 Resolved
Vessel crew was found without adequate food and water.
Action required: 705 - Other - as specified
Resolved 28 March 2002
Documentation
Issued 26 February 2001 Resolved
Provide document stating that the vessel is less the 500 nation gross tons.Prior to entering United States.
Condition: Unknown
Due 26 February 2001
Resolved 28 March 2002
Documentation
Issued 26 February 2001 Resolved
Certificate of registry has an expiration date of April 2000. Provide valid certificate prior to entring United States.
Condition: Unknown
Due 26 February 2001
Resolved 28 March 2002
Unknown
Issued 26 February 2001 Resolved
Vessel issued COTP Order #01-140 on 01 March 2001 to depart U.S. waters by 1700 hours; vsl remained in U.S. waters until 08 March 2001.
Condition: Unknown
Due 1 March 2001
Resolved 14 March 2001
Documentation
Issued 26 February 2001 Resolved
Prove the vessel is properly manned in accordance with the Safe Manning Certificate. Prior to entering United States.
Condition: Unknown
Due 26 February 2001
Resolved 28 March 2002
Documentation
Issued 26 February 2001 Resolved
Vessel had failed to send MSO Miami Advance notice of arrivals in accordance with 33 CFR 160.201. Vessel to send in notice of arrivals priorto entering the United States.
Condition: Unknown
Due 26 February 2001
Resolved 28 March 2002
Unknown
Issued 26 February 2001 Resolved
Vessel remained in U.S. waters on 04 March 2001 after being ordered to depart by 01 March 2001.
Condition: Unknown
Due 1 March 2001
Resolved 12 June 2001
Accommodation/Occupational Safety
Issued 26 February 2001 Resolved
Found Type III MSD overboard discharge open. Toilets were discharging directly overboard. Closed overbaords.
Condition: Unknown
Due 26 February 2001
Resolved 2 March 2001
Unknown
Issued 26 February 2001 Resolved
Vessel remained in U.S. waters on 06 March 2001 after being ordered to depart by 01 March 2001.
Condition: Unknown
Due 1 March 2001
Resolved 12 June 2001
Unknown
Issued 26 February 2001 Resolved
Vessel remained in U.S. waters on 05 March 2001 after being ordered to depart on 01 March 2001.
Condition: Unknown
Due 1 March 2001
Resolved 12 June 2001
Unknown
Issued 26 February 2001 Resolved
Vessel remained in U.S. waters on 02 March 2001 after being ordered to depart by 01 March 2001
Condition: Unknown
Due 1 March 2001
Resolved 11 June 2001
Unknown
Issued 26 February 2001 Resolved
Vessel remained in U.S. waters on 03 March 2001 after being ordered to depart by 01 March 2001.
Condition: Unknown
Due 1 March 2001
Resolved 11 June 2001
Unknown
Issued 26 February 2001 Resolved
Vessel remained in U.S. waters on 07 March 2001 after being ordered to depart on 01 March 2001.
Condition: Unknown
Due 1 March 2001
Resolved 12 June 2001
Construction/Loadline
Issued 14 February 2001 Resolved
PRIOR TO DEPARTURE REPAIR WATERTIGHT DOOR TO ENGINEROOM.
Condition: Unknown
Due 14 February 2001
Resolved 20 February 2001
Lifesaving
Issued 14 February 2001 Resolved
PRIOR TO DEPARTURE SECURE ALL OXYGEN/ACETLYENE BOTTLES.
Condition: Unknown
Due 14 February 2001
Resolved 20 February 2001
Construction/Loadline
Issued 14 February 2001 Resolved
PRIOR TO DEPARTURE, PROVIDE FLAG PROPOSAL ON REPAIRS TO BE CONDUCTED ON MAJOR INSET STBD SIDE FOREPEAK.
Condition: Unknown
Due 14 February 2001
Resolved 20 February 2001
Accommodation/Occupational Safety
Issued 14 February 2001 Resolved
PRIOR TO 14MAR01, PROVIDE ADEQUATE VENTILATION IN PAINT LOCKER.
Condition: Unknown
Due 14 March 2001
Resolved 28 March 2002
Fire Fighting
Issued 14 February 2001 Resolved
PROVIDE ACCEPTABLE FIXED FIRE EXTINGUISHING SYSTEM TO PAINT LOCKER AND REMOVE EXISTING ARRANGEMENT.
Condition: Unknown
Due 14 March 2001
Resolved 28 March 2002
Navigation
Issued 14 February 2001 Resolved
PRIOR TO DEPARTURE REPAIR/REPLACE LOSS OF POWER ALARM TO STEERING PUMP.
Condition: Unknown
Due 14 February 2001
Resolved 20 February 2001
Electrical
Issued 14 February 2001 Resolved
PRIOR TO 14MAR01 REMOVE DEAD-END AND EXPOSED WIRING THROUGHOUT SHIP.
Condition: Unknown
Due 14 March 2001
Resolved 20 February 2001
Accommodation/Occupational Safety
Issued 14 February 2001 Resolved
PRIOR TO 14MAR01 REMOVE REEFER AND WIRING TO REEFER ON STARBOARD SIDE.
Condition: Unknown
Due 14 March 2001
Resolved 28 March 2002
Deck/Cargo
Issued 14 February 2001 Resolved
PRIOR TO 14MAR01 REPLACE/REPAIR ALL HOISTING EQUIPMENT.
Condition: Unknown
Due 14 March 2001
Resolved 20 February 2001
Engineering
Issued 14 February 2001 Resolved
PRIOR TO DEPARTURE PROVIDE CLASS REPORT ON THE CONDITION OF THE MAIN AS A RESULT OF LOSS OF PROPULSION WHILE OUTBOUND TAMPA BAY.
Condition: Unknown
Due 22 February 2001
Resolved 23 February 2001
Construction/Loadline
Issued 14 February 2001 Resolved
REPAIR DOG ON WATERTIGHT DOOR TO FORWARD BOSUN HOLE.
Condition: Unknown
Due 14 February 2001
Resolved 20 February 2001
Lifesaving
Issued 14 February 2001 Resolved
PRIOR TO DEPARTURE, REMOVE OIL IN BOSUN HOLE.
Condition: Unknown
Due 14 February 2001
Resolved 20 February 2001
Lifesaving
Issued 14 February 2001 Resolved
PRIOR TO DEPARTURE, REMOVE OIL FROM ENGINE ROOM BILGE.
Condition: Unknown
Due 14 February 2001
Resolved 20 February 2001
Lifesaving
Issued 14 February 2001 Resolved
PRIOR TO DEPARTURE, REMOVE PRESSURE VESSEL'S FROM FORWARD AREA OF SHIP AND SECURE PROPERLY.
Condition: Unknown
Due 14 February 2001
Resolved 20 February 2001
Documentation
Issued 19 August 2000 Resolved
Provide loadline certificate that matches the sideshell markings._x001C_ _x001C_
Condition: Unknown
Due 19 August 2000
Resolved 19 September 2000
Documentation
Issued 19 August 2000 Resolved
provide gaugings of Main deck and side shell above waterline.
Condition: Unknown
Due 19 August 2000
Resolved 19 September 2000
Electrical
Issued 19 August 2000 Resolved
Repair main and emergency generators.
Condition: Unknown
Due 19 August 2000
Resolved 19 September 2000
Accommodation/Occupational Safety
Issued 19 August 2000 Resolved
Crop and renew wasted ladders and gunnels._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 2000
Resolved 6 September 2000
Documentation
Issued 19 August 2000 Resolved
Provide second GMDSS licensed officer.
Condition: Unknown
Due 19 August 2000
Resolved 6 September 2000
Documentation
Issued 19 August 2000 Resolved
provide class report addressing wastage in fore-peak tank, fwd cargo hatches, bended frames fwd stbd bow and aft port quarter.
Condition: Unknown
Due 19 August 2000
Resolved 6 September 2000
Construction/Loadline
Issued 19 August 2000 Resolved
crop and renew wasted tank vents.
Condition: Unknown
Due 19 August 2000
Resolved 6 September 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.