← All vessels
ISMAEL
ISMAEL is a freight ship. The Coast Guard has recorded 15 inspections since 2000, most recently in February 2024, along with 76 deficiencies and 6 operational controls.
Records from 2000 to 2024. Most recent: inspection, 29 February 2024.
- Built
- Not recorded
- Last inspected
- 29 February 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 76 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
5411137 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
CPB625
509350
Flag
BOLIVIA
—
Maury page id
psix-509350
Inspections, by type
…with no type recorded10
Years with a record
6 calendar years (2000–2024)
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it747 - Convention (Subpart B), Gross Ton
423 - Regulatory (Subpart C or D), Gross Ton
441 - Convention (Subpart B), Net Ton
423 - Regulatory (Subpart C or D), Gross Ton
441 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 15
29 February 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7872331
8 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5995538
11 March 2003
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1755921
20 September 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1686001
10 May 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1615272
14 January 2002
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1478794
10 January 2002
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1477491
27 December 2001
Examination of Repairs · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1474342
2 March 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 638082
26 February 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 287579
21 February 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 106861
14 February 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 287181
19 August 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 281207
12 June 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 638081
4 June 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 535704
Deficiency record · 76
Pollution Prevention/Response › Prevention Equipment
Issued 10 May 2002
Resolved
Prove proper operation of the OWS prior to next U.S. Port call. Vsl is not to use the OWS. LEGACY COMPONENT DESC: Oily Water Separator (100 ppm)
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 10 May 2002
Resolved
Provide medical certificates for Chief Engineer and Oiler proor to next U.S. Port call.
Pollution Prevention/Response › Prevention Equipment
Issued 10 May 2002
Resolved
Remove excess waste oil from Bilge to an approved shore side facility. Provide receipt to the MSO. LEGACY COMPONENT DESC: Bilge Monitor
Pollution Prevention/Response › Prevention Equipment › Internal Cargo Transfer Capability
Issued 10 May 2002
Resolved
Retain all oily waste water within vsl. Ensure that Oil Record Book coinsides with xfer of oil wastewater.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 May 2002
Resolved
Replace retro-reflective tape for ringbuoy on starboard side fwd.
Pollution Prevention/Response › Prevention Equipment
Issued 5 February 2002
Resolved
Person in charge was not immediately available during critical stages(Topping off) of transfer of diesel fuel.
Pollution Prevention/Response › Prevention Equipment
Issued 5 February 2002
Resolved
Four persons required for transfer operations as posted on transfer procedures. only three persons were performing operations.
Pollution Prevention/Response › Prevention Equipment
Issued 5 February 2002
Resolved
No declaration of inspection was on board and available for inspection.
Pollution Prevention/Response
Issued 5 February 2002
Resolved
The transfer was performed through an open fuel tank access plate and not through a fixed connection or fill pipe as required.
Pollution Prevention/Response › Prevention Equipment
Issued 5 February 2002
Resolved
Drains to fixed containment were open and not plugged as required. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Deck/Cargo › Ballast
Issued 14 January 2002
Resolved
PERFORM PERMANENT REPAIRS TO WASTED BALLAST PIPING LEGACY COMPONENT DESC: Piping
Deck/Cargo › Ballast
Issued 14 January 2002
Resolved
SEGREGATE BALLAST TANK WITH WATERTIGHT BULKHEAD IN ACCORDANCE WITH CALCULATED STABILITY MANUAL LEGACY COMPONENT DESC: Segregated Ballast Tank
Pollution Prevention/Response › Prevention Equipment
Issued 14 January 2002
Resolved
ELIMINATE POSSIBILITY FOR SEWAGE TO DISCHARGE THROUGH BALLAST SYSTEM LEGACY COMPONENT DESC: Sewage System Piping
Engineering › Fuel Oil Storage/Transfer System
Issued 14 January 2002
Resolved
ELIMINATE POSSIBILITY FOR FUEL DISHARGE OVERBOARD THROUGH BALLAST SYSTEM LEGACY COMPONENT DESC: Piping
Operations/Management › Pollution
Issued 14 January 2002
Resolved
IMMEDIATELY REMOVE STANDING OIL ON DECKS LEGACY COMPONENT DESC: Control of Discharge of Oil
Operations/Management › Pollution
Issued 14 January 2002
Resolved
IMMEDIATELY COVER AND STORE OPEN BARRELS OF OIL LEGACY COMPONENT DESC: Control of Discharge of Oil
Pollution Prevention/Response › Prevention Equipment
Issued 14 January 2002
Resolved
IOPP Certificate indicates that no standard discharge connection was on board the vesses as required, when asked about the standard discharge connection chief engineer stated that none was on board. LEGACY COMPONENT DESC: Standard Discharge Connection
Pollution Prevention/Response › Prevention Equipment
Issued 14 January 2002
Resolved
OWS piping was found not properly piped to allow proper operation of OWS. chief engineer stated that oily mixtures were placed in ballast tanks due to the condition of OWS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Pollution Prevention/Response › Prevention Equipment
Issued 14 January 2002
Resolved
Oily residues were contained in ballast tanks.
Pollution Prevention/Response › Prevention Equipment
Issued 14 January 2002
Resolved
Overboard valve from MSD was not secured as required. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Pollution Prevention/Response
Issued 5 January 2002
Resolved
Vessel entered the Port of Canaveral and docked at a terminal that did not hold the proper Certificate of Adequacy for the vessel.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 27 December 2001
Resolved
Repair non-operating toilet and replace missing wash basin in crew head. LEGACY COMPONENT DESC: Number Per Persons
Fire Fighting › Fire Hoses
Issued 27 December 2001
Resolved
Replace missing couplings on fire hoses. LEGACY COMPONENT DESC: Connections
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 27 December 2001
Resolved
Fixed firefighting piping in emergency generator space was found wasted. LEGACY COMPONENT DESC: Piping
Personnel › Manning/Qualifications
Issued 27 December 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Rescue Boat
Issued 27 December 2001
Resolved
Engine was inoperable. LEGACY COMPONENT DESC: Propulsion Engine
Documentation › Certificates/Documents
Issued 27 December 2001
Resolved
WITHDRAWN LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Documentation › Certificates/Documents
Issued 27 December 2001
Resolved
WITHDRAWN LEGACY COMPONENT DESC: International Load Line Certificate
Documentation › Certificates/Documents
Issued 27 December 2001
Resolved
WITHDRAWN LEGACY COMPONENT DESC: International Tonnage Certificate
Documentation › Certificates/Documents
Issued 27 December 2001
Resolved
WITHDRAWN LEGACY COMPONENT DESC: IOPP Certificate
Documentation › Certificates/Documents
Issued 27 December 2001
Resolved
WITHDRAWN LEGACY COMPONENT DESC: Cargo Ship Safety Certificate
Operations/Management › Port and Waterways Safety
Issued 27 December 2001
Resolved
Vessel failed to provide required notice of arrival. LEGACY COMPONENT DESC: Notice of Arrival, General
Electrical › Electric Generation Source (service)
Issued 27 December 2001
Resolved
Main Generator was found inoperable. LEGACY COMPONENT DESC: Generator
Electrical › Electrical Distribution System (service)
Issued 27 December 2001
Resolved
Electrical distribution panel in passageway was found not attached properly. LEGACY COMPONENT DESC: Distribution Panel Bus
Electrical › Electrical Distribution System (service)
Issued 27 December 2001
Resolved
Distribution panels throughout the vessel were found in poor condition, inadequate wiring, improper wiring, missing switches, improper closures. LEGACY COMPONENT DESC: Wiring
Construction/Loadline › Hull
Issued 27 December 2001
Resolved
Hull thickness in engine room was found in poor condition, water was observed weeping throught hull. LEGACY COMPONENT DESC: Bottom Plating
Construction/Loadline › Hull
Issued 27 December 2001
Resolved
Longitudinal frames were found bent in emergency generators space and paint locker. LEGACY COMPONENT DESC: Longitudinal Frame
Lifesaving › Inflatable Liferafts
Issued 27 December 2001
Resolved
Both Liferafts and Hydrostatic releases exceeded the service dates. LEGACY COMPONENT DESC: Carriage Requirement
Lifesaving › Lifejacket/PFD (Type I)
Issued 27 December 2001
Resolved
PFD'S were missing personal marker lights. LEGACY COMPONENT DESC: Lights
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 27 December 2001
Resolved
CO2 tank for fixed fire system in paint locker was found empty. LEGACY COMPONENT DESC: Quantity of CO2
Fire Fighting › Emergency Fire Pumps
Issued 27 December 2001
Resolved
Emergency Fire Pump had inadequate pressure. LEGACY COMPONENT DESC: Pressure
Lifesaving › Lifejacket/PFD (Type V)
Issued 27 December 2001
Resolved
Lights on ring bouys were inoperable. LEGACY COMPONENT DESC: Lights
Accommodation/Occupational Safety
Issued 27 December 2001
Resolved
Vessel crew was found without adequate food and water.
Documentation
Issued 26 February 2001
Resolved
Provide document stating that the vessel is less the 500 nation gross tons.Prior to entering United States.
Documentation
Issued 26 February 2001
Resolved
Certificate of registry has an expiration date of April 2000. Provide valid certificate prior to entring United States.
Unknown
Issued 26 February 2001
Resolved
Vessel issued COTP Order #01-140 on 01 March 2001 to depart U.S. waters by 1700 hours; vsl remained in U.S. waters until 08 March 2001.
Documentation
Issued 26 February 2001
Resolved
Prove the vessel is properly manned in accordance with the Safe Manning Certificate. Prior to entering United States.
Documentation
Issued 26 February 2001
Resolved
Vessel had failed to send MSO Miami Advance notice of arrivals in accordance with 33 CFR 160.201. Vessel to send in notice of arrivals priorto entering the United States.
Unknown
Issued 26 February 2001
Resolved
Vessel remained in U.S. waters on 04 March 2001 after being ordered to depart by 01 March 2001.
Accommodation/Occupational Safety
Issued 26 February 2001
Resolved
Found Type III MSD overboard discharge open. Toilets were discharging directly overboard. Closed overbaords.
Unknown
Issued 26 February 2001
Resolved
Vessel remained in U.S. waters on 06 March 2001 after being ordered to depart by 01 March 2001.
Unknown
Issued 26 February 2001
Resolved
Vessel remained in U.S. waters on 05 March 2001 after being ordered to depart on 01 March 2001.
Unknown
Issued 26 February 2001
Resolved
Vessel remained in U.S. waters on 02 March 2001 after being ordered to depart by 01 March 2001
Unknown
Issued 26 February 2001
Resolved
Vessel remained in U.S. waters on 03 March 2001 after being ordered to depart by 01 March 2001.
Unknown
Issued 26 February 2001
Resolved
Vessel remained in U.S. waters on 07 March 2001 after being ordered to depart on 01 March 2001.
Construction/Loadline
Issued 14 February 2001
Resolved
PRIOR TO DEPARTURE REPAIR WATERTIGHT DOOR TO ENGINEROOM.
Lifesaving
Issued 14 February 2001
Resolved
PRIOR TO DEPARTURE SECURE ALL OXYGEN/ACETLYENE BOTTLES.
Construction/Loadline
Issued 14 February 2001
Resolved
PRIOR TO DEPARTURE, PROVIDE FLAG PROPOSAL ON REPAIRS TO BE CONDUCTED ON MAJOR INSET STBD SIDE FOREPEAK.
Accommodation/Occupational Safety
Issued 14 February 2001
Resolved
PRIOR TO 14MAR01, PROVIDE ADEQUATE VENTILATION IN PAINT LOCKER.
Fire Fighting
Issued 14 February 2001
Resolved
PROVIDE ACCEPTABLE FIXED FIRE EXTINGUISHING SYSTEM TO PAINT LOCKER AND REMOVE EXISTING ARRANGEMENT.
Navigation
Issued 14 February 2001
Resolved
PRIOR TO DEPARTURE REPAIR/REPLACE LOSS OF POWER ALARM TO STEERING PUMP.
Electrical
Issued 14 February 2001
Resolved
PRIOR TO 14MAR01 REMOVE DEAD-END AND EXPOSED WIRING THROUGHOUT SHIP.
Accommodation/Occupational Safety
Issued 14 February 2001
Resolved
PRIOR TO 14MAR01 REMOVE REEFER AND WIRING TO REEFER ON STARBOARD SIDE.
Deck/Cargo
Issued 14 February 2001
Resolved
PRIOR TO 14MAR01 REPLACE/REPAIR ALL HOISTING EQUIPMENT.
Engineering
Issued 14 February 2001
Resolved
PRIOR TO DEPARTURE PROVIDE CLASS REPORT ON THE CONDITION OF THE MAIN AS A RESULT OF LOSS OF PROPULSION WHILE OUTBOUND TAMPA BAY.
Construction/Loadline
Issued 14 February 2001
Resolved
REPAIR DOG ON WATERTIGHT DOOR TO FORWARD BOSUN HOLE.
Lifesaving
Issued 14 February 2001
Resolved
PRIOR TO DEPARTURE, REMOVE OIL IN BOSUN HOLE.
Lifesaving
Issued 14 February 2001
Resolved
PRIOR TO DEPARTURE, REMOVE OIL FROM ENGINE ROOM BILGE.
Lifesaving
Issued 14 February 2001
Resolved
PRIOR TO DEPARTURE, REMOVE PRESSURE VESSEL'S FROM FORWARD AREA OF SHIP AND SECURE PROPERLY.
Documentation
Issued 19 August 2000
Resolved
Provide loadline certificate that matches the sideshell markings._x001C_ _x001C_
Documentation
Issued 19 August 2000
Resolved
provide gaugings of Main deck and side shell above waterline.
Electrical
Issued 19 August 2000
Resolved
Repair main and emergency generators.
Accommodation/Occupational Safety
Issued 19 August 2000
Resolved
Crop and renew wasted ladders and gunnels._x001C_ _x001C_ _x001C_
Documentation
Issued 19 August 2000
Resolved
Provide second GMDSS licensed officer.
Documentation
Issued 19 August 2000
Resolved
provide class report addressing wastage in fore-peak tank, fwd cargo hatches, bended frames fwd stbd bow and aft port quarter.
Construction/Loadline
Issued 19 August 2000
Resolved
crop and renew wasted tank vents.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.