Inspection history · 63
31 October 2013
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4744991
2 October 2013
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4727839
1 February 2010
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3673182
29 August 2009
VRP Drill
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3584781
26 August 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3578362
27 May 2009
Annual Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3488336
14 November 2008
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3363999
20 October 2008
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3347909
15 May 2008
Hull Examination · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3240761
3 May 2008
Deficiency Check · MARPOL Annex I Examination · MTSA Verification · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3197800
11 February 2008
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3148174
10 January 2008
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3127969
27 April 2007
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 2917155
15 March 2007
MARPOL Annex I Examination · MTSA Verification · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2888526
28 October 2005
Administrative Inspection · MTSA Verification · Internal Structural Exam · Hull Examination · Annual Inspection · Cargo Tank Internal
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2529203
16 February 2005
MTSA Verification · COI Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2293738
4 March 2004
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2017880
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999711
11 June 2003
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1814787
6 June 2003
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2070701
27 April 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1061860
26 September 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463616
17 February 2000
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1457747
8 February 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 814990
4 February 1999
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1360736
21 July 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 418338
1 June 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 757623
26 May 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 206931
29 April 1998
Re-Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1472333
13 February 1998
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1467966
9 February 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774288
21 March 1997
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1102677
7 February 1997
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1380752
9 February 1996
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407610
3 July 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 881621
27 April 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427046
14 June 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1429897
6 May 1993
Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431217
29 December 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1140058
25 July 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 670797
29 December 1990
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237060
24 April 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1222496
4 October 1989
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1021746
20 March 1989
Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 896708
31 August 1988
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1346656
8 August 1988
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 895776
9 December 1987
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1310485
26 June 1987
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1028937
17 November 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015721
23 July 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315788
14 April 1986
Permit to Proceed
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 999427
14 November 1985
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1302705
21 January 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1284963
10 January 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1284867
6 September 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1286736
22 June 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280750
3 May 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281249
9 March 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278728
2 February 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278699
19 January 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 971811
10 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972234
18 May 1983
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1279240
14 May 1981
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 965294
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 1 February 2010
Resolved
Generator has exhaust leak at the muffler connection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 2 October 2013
Resolution: The vessel has been out of service since 2010 and will require a full COI inspection prior to conducting any operations.
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 1 February 2010
Resolved
Generator exhaust manifold shielding is missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 2 October 2013
Resolution: The vessel has been out of service since 2010 and will require a full COI inspection prior to conducting any operations.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 1 February 2010
Resolved
Port engine pump clutch is slipping, This condition does not allow it to reach operating pressure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 2 October 2013
Resolution: The vessel has been out of service since 2010 and will require a full COI inspection prior to conducting any operations.
Lifesaving › Lifebuoys › Serviceable
Issued 1 February 2010
Resolved
Lifebuoys were in unserviceable condition and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 2 October 2013
Resolution: The vessel has been out of service since 2010 and will require a full COI inspection prior to conducting any operations.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 1 February 2010
No resolution recorded
Main Cargo Transfer Pipe is out of hydro date. Pipe needs to be tested to MAWP prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2010 — due date passed with no resolution recorded
Resolution: Vessel is out service and will need a full COI prior to conducting any operations. Closed deficiencies due to administrative procedures.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 1 February 2010
Resolved
Deck containment drains are frozen.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 2 October 2013
Resolution: Clear deficiency as vessel is out of service and will need a full COI prior to conducting any operations.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 1 February 2010
No resolution recorded
Port cargo valve is leaking product due to bad valve packing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2010 — due date passed with no resolution recorded
Resolution: Vessel is out service and will need a full COI prior to conducting any operations. Closed deficiencies due to administrative procedures.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 1 February 2010
No resolution recorded
Cargo transfer hose needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2010 — due date passed with no resolution recorded
Resolution: Vessel is out service and will need a full COI prior to conducting any operations. Closed deficiencies due to administrative procedures.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 1 February 2010
Resolved
Missing proper amount of extinguishers on board. IAW with COI.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 2 October 2013
Resolution: The vessel has been out of service since 2010 and will require a full COI inspection prior to conducting any operations.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 1 February 2010
No resolution recorded
Inadaquate containment under port quarter manifold IAW CFR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2010 — due date passed with no resolution recorded
Resolution: Vessel is out service and will need a full COI prior to conducting any operations. Closed deficiencies due to administrative procedures.
Deck/Cargo › Mooring/Anchoring › Brake
Issued 1 February 2010
No resolution recorded
Anchor windless brake was frozen.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2010 — due date passed with no resolution recorded
Resolution: Vessel was taken out service in 2010 and it is currently inactive. Closed deficiencies due to an administrative procedure. Also, prior to vessel returning to service it will need to complete a full COI inspection.
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 4 September 2009
Resolved
Vessel had large amounts of water and oil mixture with in coaming during exercise due to rains that day and the fact the vessel had a spill the previous night. Vessel had no means to remove the oily mixture from the deck. The oily water continued to spill over the coaming and created a sheen the entire time of the inspection.
Condition: Unknown
Due 4 September 2009
Resolved 4 September 2009
Resolution: Barge had to be brought back to the doc to be drained by a vac truck.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 27 May 2009
No resolution recorded
Relocate the cargo pressure gauges to a location that can be seen and read from the operating station.
Action required: 705 - Other - as specified
Due 3 June 2009 — due date passed with no resolution recorded
Resolution: Vessel is out service and will need a full COI prior to conducting any operations. Closed deficiencies due to administrative procedures.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 27 May 2009
Resolved
Repair wasted ladder attached to the cargo pump prime mover fuel tank.
Action required: 705 - Other - as specified
Due 10 June 2009
Resolved 2 October 2013
Resolution: The vessel has been out of service since 2010 and will require a full COI inspection prior to conducting any operations.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 January 2008
Resolved
Deficiency issued: 33 C.F.R. 1070 (b)(1) The owner or operator of a vessel must submit a the entire plan to the Coast Guard fro re-approval 6 months before the end of the approval period identified by subpart 155.1060(c). The VRP Control #00228 for (multiple vessels) including STATIA TRADER is due to expire 2/22/2008. To date, no resubmission has been received at by the USCG VRP Program.
Action required: 705 - Other - as specified
Due 10 July 2008
Resolved 10 July 2008
Resolution: VRP approval letter for STATIA TRADER was issued on 07/10/2008.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 27 April 2007
Resolved
33 C.F.R. 151.28(b) The owner or operator shall submit any plan amendments to Commandant (CG-3PCV-1)) for information or approval. Plan holder could not be contacted based on current information listed in SOPEP.
Action required: 705 - Other - as specified
Due 16 October 2007
Resolved 16 October 2007
Resolution: The SOPEP was approved on 10/16/2007.
Deck/Cargo
Issued 13 February 1998
Resolved
REPAIR AFT BULKHEAD OF NO. 5 STBD CARGO TANK AT SIDESHELL CONNECTION. REPAIR TO SATISFACTION OF CG/ABS._x001C_
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Deck/Cargo
Issued 13 February 1998
Resolved
SERVICE AND SET CARGO PUMP RELIEF DEVICES.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Electrical
Issued 13 February 1998
Resolved
MAKE ALL ELECTRICAL INSTALLATIONS IN HAZARDOUS LOCATIONS, SUITABLE FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Electrical
Issued 13 February 1998
Resolved
PROVE PROPER OPERATION OF AIR RECEIVER RELIEF VALVE._x001C_
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Deck/Cargo
Issued 7 February 1997
Resolved
RE PACK CARGO VALVE REACH RODS.
Condition: Unknown
Due 7 March 1997
Resolved 21 March 1997
Deck/Cargo
Issued 7 February 1997
Resolved
SUPPLY AND INSTALL BRAVO FLAG/PENNANT.
Condition: Unknown
Due 7 March 1997
Resolved 21 March 1997
Deck/Cargo
Issued 7 February 1997
Resolved
MAKE REMOTE SHUT DOWN ON PORT ENGINE OPERABLE.
Condition: Unknown
Due 7 March 1997
Resolved 21 March 1997
Documentation
Issued 27 April 1995
Resolved
PROVIDE ON BOARD A U.S. COAST GUARD APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP). SOPEP MUST BE VESSEL SPECIFIC.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Electrical
Issued 29 December 1992
Resolved
Install cover on elbow to electrical conduit located outside on starboard side of deck container before next cargo operation. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Unknown
Issued 29 December 1992
Resolved
Remove 55 gallon drums mounted on top of cargo header pipes, located aft._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Engineering
Issued 29 December 1992
Resolved
Replace or remove wasted drainline on diesel day tank located aft between cargo pump engine._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Deck/Cargo
Issued 29 December 1992
Resolved
Before carrying freight for hire, clean forward rake and gas free if possible. Install flame screen on vent._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Deck/Cargo
Issued 29 December 1992
Resolved
Replace fuel supply hose from day tank to primary filter on port cargo engine._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Deck/Cargo
Issued 29 December 1992
Resolved
Install protective guards on cargo engines vertical exhaust. Both port andstarboard engines._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Electrical
Issued 29 December 1992
Resolved
Before next cargo operation. Install cover on wiring conduit elbow locatedabove circuit breakers in starboard deck container._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Electrical
Issued 29 December 1992
Resolved
Install covers on electrical outlet, install globe over light and replace cover on electrical outlet in port deck container prior to next cargo operation._x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Deck/Cargo
Issued 29 December 1992
Resolved
Before carrying freight for hire, empty number 1 starboard cargo tank. Do not load this tank until permanent repairs are made to forward bulkhead._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Deck/Cargo
Issued 29 December 1992
Resolved
Remove doubler plate. Make permanent repairs to #1 starboard cargo tank. Audio gauge bulkhead to determine overall thickness. Provide report to attending Coast Guard marine inspector. _x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Unknown
Issued 29 December 1992
Resolved
Make both pressure vessels available for internal inspection. Provide USCG numbers, service data, manufacturer, working pressure information. On deckmounted peressure vessel, renew unapproved hoses with approved hoses. Pressure vessels are located on deck and in deck mounted container.
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Construction/Loadline
Issued 29 December 1992
Resolved
Repair/renew broken dog on number 1 port cargo hatch cover and number 2 starboard cargo hatch cover._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Deck/Cargo
Issued 29 December 1992
Resolved
Open all PV valves and make available for inspection by attending Coast Guard marine inspector._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Deck/Cargo
Issued 29 December 1992
Resolved
Replace pipeline bracket on forward starboard header prior to loading cargo._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Deck/Cargo
Issued 29 December 1992
Resolved
Install flange bolts where missing on blending loop, port side between number 4 and 5 port side cargo tanks._x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Documentation
Issued 29 December 1992
Resolved
Provide evidence that certificate of financial responsibility has been reissued._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 January 1993
Resolved 22 January 1993
Construction/Loadline
Issued 20 March 1989
Resolved
COMPLETE PERMENT REPAIRS TO HULL PLATING AND INTERNAL FRAMES, FWD RAKE AREA, STBD SIDE, AT NEXT DRYDOCK OR PRIOR TO 31JUL90.
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Deck/Cargo
Issued 26 June 1987
Resolved
ALL FLAME SCREENS BADLY RUSTED AND BLOCKED. NEEDED REPLACEMENT.
Condition: Unknown
Due 26 June 1987
Resolved 26 June 1987
Deck/Cargo
Issued 26 June 1987
Resolved
MUFFLER ON STARBOARD DIESEL ENGINE FOR CARGO PUMP BADLY WASTED, NEEDED RE- PLACEMENT.
Condition: Unknown
Due 26 June 1987
Resolved 26 June 1987
Construction/Loadline
Issued 26 June 1987
Resolved
CRACKS IN THE FWD RAKE IN WAY OF #1 CARGO TANK AT 2ND AND 4TH TRANSVERSE STIFFENER FROM THE HATCH, ALSO ALONG SIDE SHELL AND BULKHEAD IN SAME COM- PARTMENT.
Condition: Unknown
Due 26 June 1987
Resolved 26 June 1987
Fire Fighting
Issued 26 June 1987
Resolved
NO EVIDENCE THAT FIRE EXTINGUISHERS HAD BEEN SERVICED.
Condition: Unknown
Due 26 June 1987
Resolved 26 June 1987
Navigation
Issued 14 April 1986
Resolved
MAKE NAVIGATION LIGHTS OPERATIONAL.
Condition: Unknown
Due 14 April 1986
Resolved 14 April 1986
Navigation
Issued 14 November 1985
Resolved
PROVE SATISFACTORY OPERATION OF ANCHOR LIGHT
Condition: Unknown
Due 14 November 1985
Resolved 14 November 1985
Deck/Cargo
Issued 14 November 1985
Resolved
REPAIR CRACKED WELD BETWEEN #1 STBD CARGO TANK AND FWD RAKE
Condition: Unknown
Due 14 November 1985
Resolved 14 November 1985
Construction/Loadline
Issued 14 November 1985
Resolved
CROP AND RENEW DECK PLATING ON MAIN DECK IN WAY OF #5 PORT CARGO TANK WHEREHOLED (2 LOCATIONS)
Condition: Unknown
Due 14 November 1985
Resolved 14 November 1985
Documentation
Issued 14 November 1985
Resolved
HAVE DOCUMENT ENDORSED FOR REGISTRY
Condition: Unknown
Due 14 November 1985
Resolved 14 November 1985
Deck/Cargo
Issued 14 November 1985
Resolved
PROVE SATISFACTORY OPERATION OF EMERGENCY SHUTDOWNS ON CARGO PUMPS.
Condition: Unknown
Due 14 November 1985
Resolved 14 November 1985
Deck/Cargo
Issued 14 November 1985
Resolved
REPLACE ALL FLAME SCREENS ON CARGO TANK VENTS
Condition: Unknown
Due 14 November 1985
Resolved 14 November 1985
Unknown
Issued 22 June 1984
Resolved
ISSUED PERMIT TO PROCEED TO HOUSTON, TEXAS; ENTER CARGO TANKS & GUAGE LONG-ITUDINAL & TRANSVERSE BULKHEAD IN WAY OF DECK TO DETERMINE WASTAGE & REPAIR
Condition: Unknown
Due 22 June 1984
Resolved 22 June 1984