MAURY USCG vessel records Sign in
← All vessels

JACOB

JACOB is a 1999 tank ship. The Coast Guard has recorded 14 inspections since 2000, most recently in October 2015, along with 11 deficiencies and 1 operational control.

Records from 2000 to 2015. Most recent: inspection, 8 October 2015.

Built
1999
Last inspected
8 October 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9191395 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
509734
Flag
LIBERIA
—
Maury page id
psix-509734

Inspections, by type

…with no type recorded5
Years with a record 6 calendar years (2000–2015)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it25202 - Regulatory (Subpart C or D), Gross Ton
11959 - Regulatory (Subpart C or D), Net Ton
43716 - Dead Weight, Ton
53058 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEA SAPPHIRE Tank Ship · MISLE 409569 · 20 September 2004 · activity 2203008

Inspection history · 14

8 October 2015 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5738187
12 September 2015 ISPS II Exam · Ballast Water Examination · COC-TVE Renew · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5717583
6 September 2006 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2771264
2 September 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2766912
15 November 2005 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2534176
15 November 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2534832
30 November 2004 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2250387
20 September 2004 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2203008
12 September 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2193624
11 May 2004 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2064571
19 April 2004 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2047949
6 November 2002 Tank Vessel Examination · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1699270
7 April 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 276502
7 April 2000 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 817491

Deficiency record · 11

Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 12 September 2015 Resolved
A second source of energy shall be provided for additional three starts within 30 minutes unless manual starting can be demonstrated as effective. PSCO's observed 3 failed attempts of manual starting. Vessel does not have secondary means of starting emergency generator. 74 SOLAS (04 cons)II-1/44.2 Action Taken: 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2015
Resolution: The vessel's crew was able to demonstrate proper secondary start of the emergency generator. Action 10c
Engineering › Generator (propulsion/auxiliary-electric) › Charger
Issued 12 September 2015 Resolved
Where automatic starting is not required, manual starting is permissable, such as hydraulic accumulators, where they can be demonstrated as being effective. PSCO's observed 3 failed attempts of the hydraulic accumulator of the emergency generator. 74 SOLAS (04 cons)II-1/44.4.1 Action taken: 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2015
Resolution: The vessel received dispensation from flag and class for a secondary set of batteries to be installed as a temporary back-up start until class can attend the vessel at the next port call.
Engineering › Steering Gear System › Pump
Issued 12 September 2015 Resolved
Hydraulic power operated steering gear shall be provided with arrangements to maintain cleanliness of the hydraulic fluid. The #1 steering pump is leaking causing the rudder to hunt for position. 74 SOLAS (04 cons)II-1/29.12.1 Action Taken 16(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2015
Resolved 3 October 2015
Resolution: Oil seals renewed in way of the shaft. Tested system with the presence of Class Surveyor and no leakages observed and no hunting for position anymore.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 September 2015 Resolved
Electrical installations shall be such that the safety of the crew and ship shall be ensured. PSCO's observed wire splicing to the light fixture behind the day oil settling tank, multiple light fixture covers missing, emergency generator distribution panel indicator light inoperative. 74 SOLAS (04 cons)II-1/45 Action taken: 40(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 October 2015
Resolution: All wire splitting to the light fixtures on board rectified. New covers installed where necessary. Confirmed by Class Surveyor.
Engineering › Steam System (main) › Piping
Issued 12 September 2015 Resolved
Every steam pipe and fitting connected there through which steam may pass shall be designed, constructed, and installed as to withstand maximum working stress to which it may be subjected. PSCO's observed steam leak in the boiler piping running from the boiler to cargo pump room in the engine room. 74 SOLAS (04 cons)II-1/33.1 Action taken 16(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2015
Resolved 3 October 2015
Resolution: All steam leakages rectified; tested system and found with not leakages anymore. Confirmed by Class Surveyor.
Engineering › Fuel Oil Service System › Valve, Control
Issued 12 September 2015 Resolved
Emergency generator fuel shutoff shall be maintained to conform with the provisions of the present regulations to ensure the ship will remain fit to proceed without danger to the ship or persons onboard. PSCO's observed the emergency generator emergency fuel shutoff part from the wire rope due to wastage of the wire rope. 74 SOLAS (04 cons)II-1/33.1 Action taken: 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 September 2015
Resolution: Vessel's crew replaced the wasted wire.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 September 2015 Resolved
Instruction for onboard maintenance of lifesaving appliances complying with regulation 36 shall be provided and maintainence shall be carried out accordingly. PSCO's observed immersion suit and lifejacket in engine control room that were not maintained. No instructions for maintenance and inspection could be provided by the crew. 74 SOLAS (14 cons)III/20.3.2 Action Taken 10c
Action required: 705 - Other - as specified
Due 12 October 2015
Resolved 14 September 2015
Resolution: Vessel's crew provided maintenance instructions.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 12 September 2015 Resolved
A fireman's outfit shall consist of protective clothing or material to protect the skin from heat. 02 fireman's outfits were found to have ripped and degrading protective material. 74 SOLAS (01 cons)II-2/17.1.1 Action taken: 16(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2015
Resolved 3 October 2015
Resolution: New firemens outfit supplied on board and placed at the adecuate position. Confirmed by Class Surveyor.
Lifesaving › Lifebuoys › Immediately Available
Issued 12 September 2015 Resolved
Lifebuoys complying with requirements 2.1.1 of the code shall be so stoew at to be capable of being rapidly cast loose. 02 quick-release lifebuoys were wedged within their cradle. 74 SOLAS (14 cons)III/7.1.2 Action taken: 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 September 2015
Resolution: The lifebuoys were worked lose and put in quick release installations.
Engineering › Fuel Oil Service System
Issued 19 April 2004 Resolved
Provide attestation of satisfactory operation of MOE and primary generators f/o leak detection alarms/ devices to satisfaction of certificate issuing authority.
Condition: Design Flaw
Due 19 May 2004
Resolved 11 May 2004
Resolution: RECEIVED CLASS REPORT ATTESTING TO THE SATISFACTORY OPERATION OF MOE AND PRIMARY GENERATORS F/O LEAK DETECTION ALARMS
Deck/Cargo › Inert Gas System
Issued 19 April 2004 Resolved
Provide attestation of operation of all audible and visual alarms as noted in Solas 74/78 Reg 62.19.1.1 through 19.1.9 to satisfaction of certificate issuing authority and to COTP Port Arthur.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2004
Resolution: Recieved class report stating that all inert gas alarms now repaired by crew and demonstrated satisfactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.