Inspection record

Last inspected 26 September 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC5711
509736
Flag
UNITED STATES
Maury page id
psix-509736

Documentation record

Tonnage as PSIX records it5 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 83 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

26 September 2025 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8240654
19 August 2025 DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8214638
9 July 2025 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8180789
16 August 2024 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7962714
20 January 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7851945
6 September 2023 Drydock Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7716106
14 August 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7744932
6 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7470070
2 September 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7302376
14 July 2021 Drydock Exam · Plan Review "T" Boat
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7256425
23 June 2020 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6986159
14 May 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6953499
27 June 2019 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6753375
1 August 2018 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6498070
25 July 2018 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6490712
15 August 2017 Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6235698
1 September 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6000122
2 August 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5956262
17 June 2016 Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5925535

Deficiency record · 83

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2025 Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs. Program issues: 1) One year negative paperwork not provided; 2) Terminated or ex-employees not dis-enrolled from random testing program; and 3) Missing reasonable cause testing protocols. Provide the above to the satisfaction of the attending marine inspector. 46 CFR 16.113(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2025
Resolved 2 September 2025
Resolution: Received email from vessel DER with the following documents: One year of negative paperwork provided, terminated or ex-employees disenrolled from the random testing program, and reasonable cause testing protocols; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2025 Resolved
A duct must be of rigid permanent construction, which does not allow any appreciable vapor flow except through normal openings, and made of the same material as the hull or of noncombustible material. The duct must lead as directly as possible from its intake opening to its terminus and be securely fastened and supported. Sighted ducting for engine compartment ventilation made of vinyl. Install ducting meeting the regulation described above to the satisfaction of the attending marine inspector. 46 CFR 182.465(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2025
Resolved 23 July 2025
Resolution: Received email from vessel owner with a photograph of metal ducting installed for the engine compartment ventilation.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 11 July 2025 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Compass cable to power the light were cut. Vessel is not limited to daylight operations on the COI. Properly wire compass light and prove operation in the presence of the attending marine inspector. Vessel restricted to daylight operations and resolve by July 14, 2025. 184.402(c)
Action required: 705 - Other - as specified
Due 14 July 2025
Resolved 13 July 2025
Resolution: Received email with photograph of the compass light illuminated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 July 2025 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. The adult life jackets container is incorrectly marked with 18 adult life jackets. Mark adult life jacket container with 14 adult life jackets as described above to the satisfaction of the attending marine inspector. 46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2025
Resolved 23 July 2025
Resolution: Received email from vessel owner with a photograph of the adult life jacket stowage compartment marked with 14 adult life jackets.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 July 2025 Resolved
Except as provided in paragraph (c) of this section, a vessel must be provided with an auxiliary means of steering that is a suitable hand tiller may be acceptable as the auxiliary means of steering where satisfactory to the cognizant OCMI. Vessel is single screw propulsion. Provide an acceptable auxiliary means of steering and prove proper operation in the presence of the attending marine inspector. 46 CFR 182.620(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 7 August 2025
Resolution: Provide an acceptable auxiliary means of steering. However, owner unable to prove operation due to a planned trip. Issued updated CG835V. Refer to narrative for details.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 July 2025 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio Beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. FCC Station license and Safety Radiotelephony Certificate were expired. Provide a valid FCC Station License as prescribed by 47 CFR 80.13 and a valid Safety Radiotelephony Certificate as prescribed by 47 CFR 80. 401 to the satisfaction of the attending marine inspector. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 23 July 2025
Resolution: Received email from vessel owner with valid FCC Station License.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2025 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Life buoy retroreflective material was deteriorating, and name was not legible. Mark as per the regulation to the satisfaction of the attending marine inspector. 46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 11 July 2025
Resolution: Attended vessel and while on board the life buoy retroreflective material was renewed along with the vessel's name to the satisfaction of the marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 July 2025 Resolved
Except when in the judgment of the cognizant OCMI the operation of a vessel does not present one of the hazards listed, the emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in § 185.512. The heavy weather emergency instructions did not include rough weather or flooding as prescribed by 46 CFR 185.512(a)(1). Provide the amended Emergency Instructions to the satisfaction of the attending marine inspector. 46 CFR 185.510(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 23 July 2025
Resolution: Received email from vessel owener with a photograph of the emergency procudures posted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 July 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 19 August 2025
Resolution: Attended vessel and sighted current tide table chart.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2025 Resolved
Where a flexible fill pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. The bonding conductor was disconnected. Connect bonding conductor to the tank fill pipe end to the satisfaction of the attending marine inspector. 46 CFR 182.455(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 23 July 2025
Resolution: Received email from vessel owner with a photograph of the fuel fill bonded cable connected to another area of the tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 July 2025 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Approval of bowls of other than steel construction will specify if a flame shield is required. The Racor 500FG primary diesel fuel filter/separator does not have the required flame shield to be marine approved. 1) Provide the approved Racor heat deflector kit for this series fuel filter/water separator; or 2) Install the approved Racor 500MA diesel fuel filter/separator assembly to the satisfaction of the attending marine inspector. 46 CFR 182.455(b)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 23 July 2025
Resolution: Received email from vessel owner with a photograph of the fuel filter with the metal bowl.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 July 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Analgesic medication (aspirin) was found expired and missing 10 application antiseptic preparation. Provide these items to the satisfaction of the attending marine inspector. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 13 July 2025
Resolution: Received email with photograph of the new aspirin and the iodine swabs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected, and all required guards and protective devices must be in satisfactory condition. The reduction gear oil non-metallic hoses to the raw water cooler are outer sheathing is cracked. Replace hoses in-kind to the satisfaction of the attending marine inspector. 46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 23 July 2025
Resolution: Received email from vessel owner with a photograph of the reduction gear cooler hoses replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 July 2025 Resolved
You must submit your written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection, as required in 176.105 of this part. Vessel's COI is expired and must not carry passengers until a new COI is completed. 46 CFR 176.404(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2025
Resolution: Completed satisfactory COI inspection. Issued COI and SPV decal.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 July 2025 Resolved
Except as provided in paragraph (c) of this section, a vessel must be provided with an auxiliary means of steering that is a suitable hand tiller may be acceptable as the auxiliary means of steering where satisfactory to the cognizant OCMI. Vessel is single screw propulsion. Prove proper operation of the emergency tiller in the presence of the attending marine inspector by 18 August 2025, or a 701 no sail will be issued to the vessel. Until operation is proven vessels route is restricted to Lakes, Bays, and Sounds. 46 CFR 182.620(b)
Action required: 705 - Other - as specified
Due 18 August 2025
Resolved 19 August 2025
Resolution: Attended vessel and witnessed satisfactory operation of the emergency tiller while vessel was underway.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 August 2024 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information: date of training, and general description of topics. There were no training records on board. Log and keep records of training to the satisfaction of the attending marine inspector. 46CFR185.420(d)(1),(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2024
Resolved 21 August 2024
Resolution: Drills logged.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 August 2024 Resolved
The required monthly EPIRB test shall be logged or otherwise documented. EPIRB testing is not documented. Document EPIRB testing to the satisfaction of the attending marine inspector. 46CFR185.728(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2024
Resolved 21 August 2024
Resolution: EPIRB test logged.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 August 2024 Resolved
A ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The name labeling is incomplete. Suitably mark life ring to the satisfaction of the attending marine inspector. 46CFR185.604(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2024
Resolved 21 August 2024
Resolution: Life ring stenciled with vessel name.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2023 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. Newly installed battery charger missing AC side circuit breaker. Install a UL 489 circuit breaker described by 46 CFR 183.380(m) of the appropriate size for the model of battery charger installed as per the manufacturers installation instructions. Battery charger use not permitted until the installation is inspected and approved by the attending MI. 46 CFR 183.380
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: Reduced COI passenger count from 13 to 12 so vessel can meet ABYC which does not require an ammeter to be in the circuit. Vessel reinstalled original battery charger that does not have an ammeter.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2023 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. Newly installed battery charger missing fuse(s) for each positive conducter from the charger to the battery/ battery bank. Install the required cartridge type fuse(s) as described by 46 CFR 183.380(k)(1)of the appropriate size for the model of battery charger installed as per the manufacturers installation instructions. Battery charger use not permitted until the installation is inspected and approved by the attending MI. 46 CFR 183.380(k)(1)
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: Reduced COI passenger count from 13 to 12 so vessel can meet ABYC which does not require an ammeter to be in the circuit. Vessel reinstalled original battery charger that does not have an ammeter.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Newly installed battery charger is not grounded or bonded in accordance with the manufacturers installation instructions. Ground and bond the battery charger as described in the manufacturers installation instructions. Battery charger use not permitted until the installation is inspected and approved by the attending MI. 46 CFR 183.200(b)
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: Reduced COI passenger count from 13 to 12 so vessel can meet ABYC which does not require an ammeter to be in the circuit. Vessel reinstalled original battery charger that does not have an ammeter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 September 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Fuel line is leaking at connection point, on the supply fuel line to secondary fuel filter. Make repairs to stop the fuel leak to the satisfaction of the Marine Inspector. 46 CFR 176.830(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2023
Resolution: Attended vessel and ran engine. Fuel line replaced with A1-15 fuel line and doubled hose clamped. No active fuel sighted; all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 September 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Observe the ingress of water from the stbd aft void into the steering compartment and water in the port void. Drain water from all spaces for observation while underway by the attending MI. 46 CFR 176.830(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2023
Resolution: Attended vessel and sighted new stbd cover installed. Inspected port and stbd void spaces for water; all sat. Conducted underway trial with both aft void spaces covers removed. No water ingress was observed; all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 29 September 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel has boogie board blocking primary aft drainage scupper area. Remove boogie board from current location upon receipt of this CG-835V form. 46 CFR 176.700(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2023
Resolution: Attended vessel and sighted the boogie board was removed from primary aft drainage scupper area.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 September 2023 Resolved
Each hatch exposed to the weather must be watertight. Each hatch cover must have securing devices; and be attached to the hatch frame or coaming by hinges,captive chains, or to other devices to prevent its loss. Steering gear compartment hatch is not watertight and does not have any hinges or attachment devices to prevent its loss. Replace and install gasket on hatch to make watertight and install lanyard attaching hatch to frame to the satisfaction of the attending MI. 46 CFR 171.124
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2023
Resolved 5 October 2023
Resolution: Attended vessel and sighted new gasket and captive lanyard installed on steering gear compartment hatch; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2023 Resolved
Battery charger must have an ammeter connect in the charging circuit. Vessel battery charging circuit does not have an ammeter installed. Install ammeter into vessel battery charging circuit or remove battery charger. 46 CFR 183.350(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2023
Resolved 5 October 2023
Resolution: Attended vessel and sighted the battery charger with built-in ammeter.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 August 2023 Resolved
A space containing diesel machinery must be fitted with at least two ducts of rigid construction to furnish natural or powered supply and exhaust. Ventilation ducts leaving engine room were wasted & disconnected. Replace wasted ventilation ducts with new ventilation ducts. 46 CFR 182.465(c)&(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2023
Resolution: New ventilation ducts were installed and connected at both ends.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 August 2023 Resolved
Vessel required to have one 20" or 24" ring lifebuoy fitted with 60' lifeline and floating water light attached with a corrosion resistant clip to allow quick disconnect. Ring lifebuoy was damaged on one side. Replace with new ring lifebuoy. 46 CFR 180.70(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2023
Resolution: Brand new USCG approved lifebuoy was onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 August 2023 Resolved
Vessel must carry one floating water light, unless it is limited to daytime operations. Vessel's water light was inoperable. Demonstrate proper operation of water light. 46 CFR 180.70(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2023
Resolution: Waterlight was found to be operational and float tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 August 2023 Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Float switch in engine compartment was inoperable. Demonstrate proper operation of bilge float switch. 46 CFR 182.520(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2023
Resolution: New float switch was installed and tested satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 August 2023 Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Vessel did not have vent closures on-board. Provide vent closures for engine room space. 46 CFR 182.465(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2023
Resolution: Ventilation closure was onboard and fit into place.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 August 2023 Resolved
A vessel not required to have a power driven fire pump must have at least three 2 1/2 gallon buckets, with an attached lanyard. The word "fire bucket" must be stenciled in a contrasting color on each bucket. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 August 2023
Resolution: Vessel has three 5 gallon buckets onboard and properly marked with lanyards. Drilled holes at the halfway marks to meet 2.5 gallons.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 August 2023 Resolved
A submersible electric bilge pump may be used as a power bilge pump, provided that the pump is permanently mounted. The aft bilge pump was not mounted in compartment. Permanently mount aft bilge pump. 46 CFR 182.520(e)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 August 2023
Resolution: Bilge pump was found mounted in compartment.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 14 August 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers and the vessel from electrical hazards, including fire, caused by or originating in electrical shock. Black wires attached to fireboy had exposed wiring and several butt connectors. Replace entire run of wire leading to fireboy. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 August 2023
Resolution: New marine grade wiring was ran to the fireboy and secured in place.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 14 August 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers and the vessel from electrical hazards, including fire, caused by or originating in electrical shock. Electrical tape was used on wiring behind the operating station. Remove electrical tape and ensure a proper connection is made. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 August 2023
Resolution: Electrical tape was removed and dead end wiring.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 14 August 2023 Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. Flexible hose leading to fuel filter had one clamp. Provide additional hose clamp on specified fuel line. 46 CFR 182.720(e)(3)(v)(B)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 August 2023
Resolution: Additional hose clamp was installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 August 2023 Resolved
Gauges to indicate engine revolutions per minute, jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. Jacket water temperature gauge was inoperable. 46 CFR 182.410(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 August 2023
Resolution: Gauge was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 August 2023 Resolved
Each EPIRB must be tested monthly. The EPIRB test shall be logged or other wise documented as applicable. Vessel did not have previous logs of EPIRB testing. Provide continuous monthly logs of EPIRB tests going forward. 46 CFR 185.728(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 August 2023
Resolution: Conducted a test of the EPIRB and logged.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 August 2023 Resolved
A vessel is inspected for compliance with the standards require by this subchapter. Machinery, equipment, and materials may be inspected in accordance with standards accepted by the [name withheld] cover found on main deck and SCUBA bottle holdback frayed on port side. Repair cover and replace holdback line on port side. 46 CFR 176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 August 2023
Resolution: New elastic holdback line was installed on the port side to match the stbd side. Broken deck cover was removed and blanked off flush with the deck.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 June 2022 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system in compliance with 181.410: A space containing propulsion machinery. Fireboy for engine room inoperable due to service pin installed. Demonstrate all shutdowns, alarms, and overrides to the attending USCG marine inspector. 46 CFR 181.420(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2022
Resolution: Attended vessel and operationally tested Fireboy operation; all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 June 2022 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Navigation lights were inoperable. Provide navigation lights that are in compliance with the Navigation Rules and prove operation to the USCG marine inspector. 46 CFR 183.420
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2022
Resolution: Onwer proved navigation lights are in compliance with the Navigation Rules and proved operation to the USCG marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2022 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The 40-B:C portable extinguisher nozzle was broken off from the discharge hose. Replace extinguisher with the correct size and type on COI. 46 CFR 181.500(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2022
Resolution: Owner replaced extinguisher with the correct size and type on COI.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 6 June 2022 Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, compass must be illuminated or restricted to daytime operation. Provide light for the compass and prove operation to the USCG marine inspector. 46 CFR 184.402(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner purchased and installed new compass and proved the compass light illuminated to the USCG marine inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 June 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked "First-Aid Kit". A first-aid kit must be easily visible and readily available to the crew. First aid kit is incomplete. Provide USCG-approved kit or a kit that complies with the list in 46 CFR 160.041. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Operator purchased a new USCG-approved kit that complies with the list in 46 CFR 160.041.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 June 2022 Resolved
Each vessel must be equipment with at least two operable portable battery lights. Vessels missing required portable lights. Provide. 46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner provided the two required portable lights.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 June 2022 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. No log or tag proving monthly inspections occurred. 46 CFR 176.810(b)(1)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner purchased new portable fire extinguishers and affixed tags to prove monthly inspections.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 June 2022 Resolved
The master of the vessel shall ensure that: Each EPIRB, other than an EPIRB in an inflatable life-raft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. No record of monthly EPIRB test. 46 CFR 185.728
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner established an EPIRB monthly testing log and tested the EPIRB in the presence of the USCG marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 6 June 2022 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Establish drill program and record for abandon ship and man overboard drills and training. 46 CFR 185.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner establish drill program and record for abandon ship and man overboard drills and training to the satisfaction of the USCG marine inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 June 2022 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Establish drill program and record for fire fighting drills and training. 46 CFR 185.524
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner establish drill program and record for fire fighting drills and training to the satisfaction of the USCG marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2022 Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. Flexible fill pipe section missing conductor protecting against generation of a static charge when filling with fuel. 46 CFR 182.445(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 5 July 2022
Resolution: Flexible fill pipe section conductor protecting against generation of a static charge when filling with fuel properly bonded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2022 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Remote fuel shut off not clearly marked and missing direction of operation. [name withheld] the above to the satisfaction of the attending USCG marine inspector. 46 CFR 185.068
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner clearly marked fuel shut off and its direction of operation to the satisfaction of the attending USCG marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2022 Resolved
Each life jacket kept in a stowage container must be readily available. Vessel storing supplies and engine fluids in child size life jacket stowage container. Remove all stores/supplies to make child size life jackets readily available. 46 CFR 180.78(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2022
Resolution: Owner removed all stores/supplies to make child size life jackets readily available to the satisfaction of the USCG marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2022 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Brackets for fire extinguishers are unapproved. Replace with USCG approved brackets as referenced on each label. 46 CFR 181.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner provided purchased new portable fire extinguishers and installed with the USCG approved brackets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 June 2022 Resolved
A hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Provide hatch cover securing device. 46 CFR 179.360(3)(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner provided hatch cover securing device to the satisfaction of the USCG marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 6 June 2022 Resolved
Each hatch exposed to the weather must be watertight. aft steering ram compartment deck hatch cover not watertight. Provide gasket to make aft steering ram compartment deck hatch cover watertight. 46 CFR 179.360(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner installed gasket toto make aft steering ram compartment deck hatch cover watertight to the satisfaction of the USCG marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Negative and positive single studs under console and at engine room battery have more than four terminals attached. To prevent heat build up and a possible fire limit the number of terminals attached to a stud at four. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner installed a negative and a positive bus bar under the console. Also, the owner installed a battery terminal mount bus bar on the engine room battery positive post.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2022 Resolved
Battery chargers must have an ammeter connected in the charging circuit. Vessel installed battery charger missing an ammeter. Provide an ammeter to the satisfaction of the attending USCG marine inspector. 46 CFR 183.350(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner removed battery charger.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Multiple wires under console spliced together by twisting of conductors together and are not insulated. Splice wires together using pressure type solderless crimp on connectors. 46 CFR 183.200(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Owner spliced wires together using pressure type solderless crimp on connectors to the satisfaction of the USCG marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 21 June 2022
Resolution: Owner purchased new oxygen bottle.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found in engine compartment and under operator console. Properly terminate all dead end wires to the satisfaction of the attending USCG Marine Inspector. 46 CFR 183.200(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 27 June 2022
Resolution: Owner properly terminated all dead end wires to the satisfaction of the attending USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 September 2021 Resolved
A pre-engineered fixed gas fire extinguishing system must: be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector. Manual actuation cable had completely severed and worn away. Replace manual actuation cable. 46 CFR 181.420 (a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2021
Resolution: Manual actuation cable replaced with new cable.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 September 2021 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Holes in engine room ventilation duct creates opening between engine space and STBD compartment allowing fixed fire extinguishing medium to communicate through bulkhead. Renew ventilation duct to ensure quantity of extinguisher is sufficient. 46 CFR 181.420 (a)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2021
Resolution: Old ventilation duct sealed off. Current ventilation duct in good condition and able to be closed in the event of a fire.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 September 2021 Resolved
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018. Five life jackets were not marked with appropriate retro-reflective material. Provide appropriate markings to the satisfaction of the attending marine inspector. Passenger count reduced to 8. 46 CFR 185.604
Action required: 705 - Other - as specified
Resolved 9 September 2021
Resolution: Lifejacket retro renewed.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 2 September 2021 Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, compass must be illuminated or restricted to daytime operation. Provide light for the compass. 46 CFR 184.402
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 September 2021
Resolution: Magnetic compass adequately illuminates.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2021 Resolved
Electrical equipment must be installed to protect passengers and crew from electrical hazards. Electrical wires are exposed at the battery terminals posing an electrical shock hazard. Cover exposed wiring to the satisfaction of attending Marine Inspector. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 September 2021
Resolution: Vessel rep adequately covered the exposed portion of wires connecting to the battery terminal.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 September 2021 Resolved
Each vessel must be equipped with at least two operable portable battery lights. Provide two operational portable battery lights. 46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 September 2021
Resolution: Vessel rep purchased and placed two portable lights on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 September 2021 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant [name withheld] of vessels fire buckets was missing lanyard. Attach lanyard that reaches water when onboard. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 September 2021
Resolution: Firebucket lanyard replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 July 2019 Resolved
Vessel required to have one 20" or 24" ring lifebuoy fitted with 60' lifeline and floating water light attached with a corrosion resistant clip to allow quick disconnect. Ring lifebouy did not have waterlight attached. Provide proper arrangement of ring lifebuoy, lifeline, and waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 24 July 2019
Resolution: Verified proper arrangement of life buoy, lifeline, and waterlight. //s// [name withheld]
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 July 2019 Resolved
A vessel less than 36' is required to have means of making an efficient sound signal. Vessel does not have an adequate means of producing sound signal. Provide a proper sound signaling device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 24 July 2019
Resolution: Verified means of making a proper sound signal. Vessel purchased an appropriate air horn device from West Marine. //s// [name withheld], LT
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 17 July 2019 Resolved
An emergency fuel shut off valve located inside a machinery space must be located so operator does not have to reach more than 12 inches into the space and must be shielded from flames. Vessel's fuel shutoff valve is not properly shielded. Provide an appropriate means of shielding the valve from heat or flames.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 24 July 2019
Resolution: Vessel installed an appropriate heat shield in the engineroom space. //s// [name withheld], LT
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 July 2019 Resolved
Waterlights should be serviceable and batteries replaced annually if not marked with an expiration date. Waterlight was inoperable with an unmarked battery. Provide serviceable waterlight and replace battery.
Action required: 10 - Deficiency Rectified
Due 17 July 2019
Resolved 17 July 2019
Resolution: Vessel master replaced battery. Proved proper operation of serviceable waterlight. //s// [name withheld], LT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 July 2019 Resolved
Battery installations must be mounted too protect against shifting of the vessel and free from exposure to water splash or spray. Vessel's battery covers are warped and do not adequately cover the existing battery configuration. Provide suitable protection against exposure to water or spray.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 24 July 2019
Resolution: Verified proper installation of battery covers. Vessel installed new battery cases and covers. Photo attached in MISLE documents. //s// [name withheld], LT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2018 Resolved
Vent pipes terminating on the hull exterior must be installed or equipped to prevent the accidental contamination of the fuel by water under normal operating conditions; Fuel vent pipe cover was broken off. Reattach fuel vent pipe cover. 46 CFR 182.450 (e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2018
Resolution: Attending MI verified repair made to fuel vent cover. New cover was attached.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 1 August 2018 Resolved
A vessel on which a pre-engineered fixed gas fire extingushing system is installed must have: an audible alarm that sounds upon discharge; Audible alarm did not sound while testing pre-engineered system. Prove proper operation of audible alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2018
Resolution: Attending MI verified functionality of alarm for pre-engineered system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2018 Resolved
All cable and wire must be installed as to avoid chafing and other damage; Vessel wiring behind steering console is bundled together. rearrange so as to minimize chafing and other damage to wires.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2018
Resolution: Vessel Rep submitted picture of cable wiring behind steering console. Wires were rearranged to minimize chafing and damage to wiring.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 15 August 2017 Resolved
Include conditions for flooding in the vessel's emergency instructions. 46 CFR 185.512(a)
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 31 August 2017
Resolution: Emergency instructions updated with flooding.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 15 August 2017 Resolved
Replace wasted portable fire extinguisher bracket in forward compartment. 46 CFR 181.520
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 31 August 2017
Resolution: New extinguisher and bracket purchased and installed in fwd compartment.
Engineering › Fuel Oil Service System › Piping
Issued 15 August 2017 Resolved
Flexible hose fuel piping found with unapproved connection to metallic piping using one hose clamp. Flexible hose approved in fuel systems must be connected to fuel piping using a SAE-J-1475 fitting. 46 CFR 182.720
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 31 August 2017
Resolution: Flexible piping removed and replaced with stainless steel piping.
Engineering › Fuel Oil Service System › Valve, Control
Issued 15 August 2017 Resolved
Replace wasted fuel shutoff valve handle in kind. 46 CFR 182.455
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 31 August 2017
Resolution: New fuel shutoff valve replaced in kind.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 15 August 2017 Resolved
Provide valid FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 31 August 2017
Resolution: Valid FCC Safety Certificate onboard.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 August 2016 Resolved
Tears in lifejacket coatings
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 15 August 2017
Resolution: All lifejackets inspected and appeared satisfactory.
Engineering › Steering Gear System › Bracket/Clamp
Issued 2 August 2016 Resolved
Provide tiller arm or other arrangement to provide means of auxilliary steering safe for operating personnel
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 15 August 2017
Resolution: Auxiliary steering tiller arm constructed by operator and tested while underway; all sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 2 August 2016 Resolved
Install insulation over exhaust pipe elbow forward of the cooling water injection point and on exhaust side of the turbocharger
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 15 August 2017
Resolution: Exhaust pipe elbow forward of the cooling water injection port found with insulation.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.