Records from 2000 to 2022. Most recent: inspection, 23 June 2022.
Inspection history · 25
23 June 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7484729
4 October 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4456795
28 October 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4179656
7 July 2011
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4119209
27 April 2010
Internal Structural Exam · Drydock Exam · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3725524
14 August 2009
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3556938
6 August 2009
DAPI Audit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3601926
29 July 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3551605
4 June 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3495004
20 May 2008
Drydock Exam · MTSA Verification · Periodic Inspection · Internal Structural Exam · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3213341
29 August 2007
MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3041741
24 August 2006
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2758023
18 November 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2538488
18 October 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2519177
2 October 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2509695
22 April 2005
Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2340348
12 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2258079
4 June 2004
Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2088329
3 July 2003
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1833704
15 May 2003
Periodic Inspection · Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1793890
23 July 2002
MARPOL Annex V Examination · Re-Inspection · Deficiency Check · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1651029
18 June 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1472697
10 August 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 823720
5 June 2000
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444368
20 April 2000
Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454797
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 7 July 2011
Resolved
Vessel rep could not demonstrate overspeed protection on the prime mover for the generator onboard. Vessel must demonstrate overspeed shutdown test to the satisfaction of the attending Coast Guard Marine Inspector within 30 days.
Action required: 705 - Other - as specified
Due 6 August 2011
Resolved 17 August 2011
Resolution: Overspeed shutdown was performed to the satisfaction of attending CG Marine Inspector.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 16 June 2010
Resolved
Provide Coast Guard with proof of updated SOPEP approval.
Action required: 705 - Other - as specified
Resolved 21 June 2010
Resolution: Barge Rep emailed current SOPEP Approval Letter.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 April 2010
Resolved
4 Starboard void space, Bay #4 Frame #4 below CTL #1 frame is buckled. C/R to satisfaction of CG Marine Inspector or ABS Surveyor. Must be completed prior to receiving credit for Internal Structural Examination.
Action required: 705 - Other - as specified
Resolved 16 June 2010
Resolution: All repairs were made to the satisfaction of ABS Surveyor.
Construction/Loadline › Hull › Bottom Plating
Issued 27 April 2010
Resolved
Clean out all tanks to remove mud/water from spaces prior to receiving credit for Dry Dock and Internal Structural Examinations.
Action required: 705 - Other - as specified
Resolved 16 June 2010
Resolution: All tanks sat
Lifesaving › Lifefloat › Serviceable
Issued 29 August 2007
Resolved
Vessel's lifefloat is wasted and no longer usuable. Vessel operations are restricted until life float is properly replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 August 2007
Resolution: Vessel replace lifefloat with six man liferaft. Liferaft will remain onboard until new lifefloat is ordered.
Lifesaving › Lifefloat › Serviceable
Issued 24 August 2006
Resolved
Prior to manning barge, provide certificate of life float servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2006
Resolution: Faxed copy of certificate of repair.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 4 June 2004
Resolved
Make anchor ready for testing.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 4 June 2004
Lifesaving › Lifefloat › Not on Board
Issued 4 June 2004
Resolved
Provide boat hook for life float.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 10 June 2004
Construction/Loadline › Hull › Side Shell
Issued 4 June 2004
Resolved
Repair stbd aft ladder handles (above pigeon holes).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 10 June 2004
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 4 June 2004
Resolved
V/W cap rails as marked and discussed.
Condition: Damaged By Earlier Event
Due 14 June 2004
Resolved 10 June 2004
Lifesaving › Lifefloat › Serviceable
Issued 4 June 2004
Resolved
Make proper repairs or replace lifefloat.
Condition: Damaged By Earlier Event
Due 14 June 2004
Resolved 10 June 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 June 2004
Resolved
Install proper lifebuoy light batteries.
Condition: Improper/Lack of Maintenance
Due 14 June 2004
Resolved 10 June 2004
Construction/Loadline › Markings › Load Line Mark
Issued 4 June 2004
Resolved
Repaint loadline marks.
Condition: Damaged By Earlier Event
Due 14 June 2004
Resolved 10 June 2004
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 4 June 2004
Resolved
Repair/replace lifeline stanchions as needed.
Condition: Damaged By Earlier Event
Due 14 June 2004
Resolved 10 June 2004
Engineering › Lubricating Oil Service System
Issued 3 June 2003
Resolved
Install a minimum of 2 hose clamps on Hydraulic suction line leading to hydraulic pump. LEGACY COMPONENT DESC: Hose
Due 3 July 2003
Resolved 2 July 2003
Engineering › Fuel Oil Service System
Issued 3 June 2003
Resolved
Renew broken bracket on fuel oil return line leading from hydraulic pump engine. LEGACY COMPONENT DESC: Piping
Due 3 July 2003
Resolved 2 July 2003
Engineering › Diesel Engine (auxiliary)
Issued 3 June 2003
Resolved
Repair exhaust leaks on generator exhaust. LEGACY COMPONENT DESC: Silencer (exhaust)
Due 3 July 2003
Resolved 2 July 2003
Electrical › Electrical Distribution System (service)
Issued 3 June 2003
Resolved
Install drip cover on electrical panel located under stairwell in hydraulic space. LEGACY COMPONENT DESC: Switchboard
Due 3 July 2003
Resolved 2 July 2003
Electrical › Electric Generation Source (service)
Issued 24 July 2002
Resolved
Identified 2 open circuit breakers in main circuit breaker panel in hydralic control room. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Unknown
Due 31 July 2002
Resolved 13 August 2002
Resolution: Two blank circuit breakers installed in panel.
Electrical › Electric Generation Source (service)
Issued 24 July 2002
Resolved
Open electrical outlet box in office space. Circular opening at the top of the box. LEGACY COMPONENT DESC: Switch
Condition: Unknown
Due 31 July 2002
Resolved 13 August 2002
Resolution: Open outlet box closed properly.
Electrical › Electric Generation Source (service)
Issued 24 July 2002
Resolved
Identified open hole in bottom of main circuit breaker panel where red wire enters panel. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Unknown
Due 31 July 2002
Resolved 13 August 2002
Resolution: Hole in electrical panel enclosed properly.
Pollution Prevention/Response › Prevention Equipment
Issued 24 July 2002
Resolved
Fixed containment under hydraulic motor oil tank contained significant amt of hydraulic oil from overfill. Required crew to clean it up. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper/Lack of Maintenance
Due 31 July 2002
Resolved 13 August 2002
Resolution: Oil cleaned out of containment.
Navigation › Collision/Grounding Avoidance
Issued 24 July 2002
Resolved
Port and Starboard running lights were inoperable. LEGACY COMPONENT DESC: Navigation Lights
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2002
Resolution: Port/stbd navigation lights repaired and working properly.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 24 July 2002
Resolved
All portable fire extinguishers onboard vessel were beyond their annual service date. Unable to determine if CO2 extinguishers without guages were sat. Service all as required. LEGACY COMPONENT DESC: Service
Condition: Unknown
Due 31 July 2002
Resolved 13 August 2002
Resolution: All portable FE''s serviced.
Lifesaving › Lifejacket/PFD (General)
Issued 24 July 2002
Resolved
Required PFD was missing light and whistle. LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2002
Resolution: Light and whistle supplied for PFD.
Lifesaving › Visual Distress Signals (General)
Issued 24 July 2002
Resolved
Barge was missing 12 required rocket flares. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2002
Resolution: 12 flares on board.
Accommodation/Occupational Safety › Occupational Safety
Issued 24 July 2002
Resolved
Approximately 75% of all deck rails and lifelines were severely damaged (bent completely over, twisted, cracked or missing). LEGACY COMPONENT DESC: Deck Rail
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2002
Resolution: All damaged deck rails replaced or repaired.
Documentation
Issued 5 June 2000
Resolved
PROVIDE COFR PRIOR TO OPERATION.
Condition: Unknown
Due 5 July 2000
Resolved 6 July 2000
Documentation
Issued 5 June 2000
Resolved
PROVIDE APPROVED SOPEP PRIOR TO OPERATION.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Construction/Loadline
Issued 5 June 2000
Resolved
OPERATE REMOTE CONTROL TO THE SATIFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000