Inspection history · 43
29 November 2018
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6589493
30 August 2006
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2766068
16 March 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2603732
8 November 2005
Annual Inspection · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2530909
4 August 2004
Annual Inspection · Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2164043
15 July 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2134272
6 January 2004
MTSA Verification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1976845
17 December 2003
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2053663
17 December 2003
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2054386
2 December 2002
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1713113
30 September 2001
Hull Examination · COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1459747
15 June 2001
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 84564
29 November 2000
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1389248
14 January 2000
Re-Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1469291
30 November 1998
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1402742
13 November 1997
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1439940
27 November 1996
Hull Examination · COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1463281
21 February 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1192056
23 January 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 877593
19 January 1996
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1185112
22 December 1995
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1184179
7 December 1995
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 879563
4 December 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 877869
13 April 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 849389
30 December 1994
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1162678
29 November 1994
Hull Examination · COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 864090
4 October 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 846959
3 August 1993
Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 842615
3 August 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1154131
10 June 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354164
24 March 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 944219
6 May 1991
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 914905
27 March 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906604
20 April 1989
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1039006
25 March 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1302407
20 May 1987
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1337398
8 July 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 523594
3 April 1986
COI Inspection · Credit Drydock
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1305127
25 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303597
20 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290120
13 February 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973437
3 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286583
31 December 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970536
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 8 November 2005
Resolved
Missing Proper ABS signatures, Owner Operator will reslove with ABS
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 21 November 2005
Resolution: Corrected errors !
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 4 August 2004
Resolved
Neck area of fire extinguisher wasted possible leak
Condition: Unknown
Due 6 August 2004
Resolved 6 August 2004
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 4 August 2004
Resolved
flame screens painted over on diesel oil tanks
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 6 August 2004
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 4 August 2004
Resolved
Current COFR on Vessel
Condition: Unknown
Due 6 August 2004
Resolved 6 August 2004
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 4 August 2004
Resolved
P/V valves needed cleaning
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 6 August 2004
Construction/Loadline › Penetrations
Issued 12 December 2002
Resolved
Replace Gasket for tank opening on #4 starboard cargo tank. LEGACY COMPONENT DESC: Gasket
Condition: Improper/Lack of Maintenance
Due 30 December 2002
Resolved 12 December 2002
Resolution: Operator replaced missing gasket.
Deck/Cargo › Vapor Control Systems
Issued 12 December 2002
Resolved
Provide proper flame screens for ullage openings on # 1 port and starboard cargo tanks. LEGACY COMPONENT DESC: Flame Screens
Condition: Damaged By Earlier Event
Due 30 December 2002
Resolved 30 December 2002
Resolution: deficiency corrected
Navigation › Collision/Grounding Avoidance
Issued 12 December 2002
Resolved
Prove proper operation of port side light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Due 30 December 2002
Resolved 30 December 2002
Resolution: deficiency corrected
Navigation › Collision/Grounding Avoidance
Issued 12 December 2002
Resolved
Provide proper black mat background for port side light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Due 30 December 2002
Resolved 30 December 2002
Resolution: deficiency corrected
Lifesaving › Immersion Suits
Issued 12 December 2002
Resolved
Repair air bladder on all immersion suits. Glue fails to hold bladder to immersion suit. Replace immersion suits prior to operating ocean going route. LEGACY COMPONENT DESC: fillable air bladder
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2003
Resolved 3 February 2003
Resolution: replaced all immersions suits all sat.
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 December 2002
Resolved
Replace five (5) Type I PFD's. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 30 December 2002
Resolved 30 December 2002
Resolution: deficiency corrected
Pollution Prevention/Response › Prevention Equipment
Issued 12 December 2002
Resolved
Permanently plug or provide for manual plugging of two holes in port aft manifold fixed oil containment bin. Holes made manually to be able to run hand railing wires/chains straight through containment. LEGACY COMPONENT DESC: Fixed Containment
Condition: Design Flaw
Due 30 December 2002
Resolved 30 December 2002
Resolution: deficiency corrected
Electrical › Lighting (emergency)
Issued 12 December 2002
Resolved
Prove proper operation of emergency lighting in generator room and in office. LEGACY COMPONENT DESC: Battery Operated Lantern
Due 30 December 2002
Resolved 30 December 2002
Resolution: deficiency corrected
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 December 2002
Resolved
Hydrostatic testing of cargo piping is required. Last Test: 09/01 LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 30 December 2002
Resolved 30 December 2002
Resolution: deficiency corrected
Lifesaving › Lifebuoys
Issued 30 September 2001
Resolved
Retro tape & grab lines wasted
Due 30 September 2001
Resolved 30 September 2001
Resolution: renewed
Construction/Loadline › Hull › Hull Plating
Issued 30 September 2001
Resolved
Had to crop & renew plate & stiffeners in various areas, see narrative for details (items 1-6).
Due 30 September 2001
Resolved 30 September 2001
Resolution: Cropped & renewed.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 30 September 2001
Resolved
E-light in Generator Room inop.
Due 30 September 2001
Resolved 30 September 2001
Resolution: corrected
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 30 September 2001
Resolved
Retroreflective Material - Wasted
Due 30 September 2001
Resolved 30 September 2001
Resolution: renewed
Engineering › Fuel Oil Service System › Filter
Issued 30 September 2001
Resolved
Fuel filter on generator prime mover leaking
Due 30 September 2001
Resolved 30 September 2001
Resolution: corrected
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 30 September 2001
Resolved
#4 stbd COT P/V flame screen missing; #2 stbd COT sounding flame screen holed
Due 30 September 2001
Resolved 30 September 2001
Resolution: replaced
Lifesaving
Issued 27 November 1996
Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR THE KVICHAK BOAT LIFERINGS.
Condition: Unknown
Due 27 December 1996
Resolved 18 December 1996
Engineering
Issued 27 November 1996
Resolved
PROVE PROPER OPERATION OF THE HYDRAULIC PUMP ENGINE.
Condition: Unknown
Due 27 December 1996
Resolved 18 December 1996
Navigation
Issued 27 November 1996
Resolved
PROVE PROPER OPERATION OF SPARE VHF-FM AND SSB RADIOS.
Condition: Unknown
Due 27 December 1996
Resolved 18 December 1996
Electrical
Issued 22 December 1995
Resolved
INSTALL EMERGENCY LIGHTING FOR LIFERAFT IN ACCORDANCE WITH 46 CFR 33.20-3.
Condition: Unknown
Due 22 December 1995
Resolved 22 December 1995
Lifesaving
Issued 7 December 1995
Resolved
VESSEL IS RESTRICTED TO CARRYING TEN PERSONNEL UNTIL VESSEL'S SIXTEEN PERSON LIFERAFT IS SERVICED AND RETURNED TO THE VESSEL. (TEN PERSON LIFERAFT IS ON BOARD-ON LOAN FROM SERVICING FACILITY).
Condition: Unknown
Due 7 December 1995
Resolved 7 December 1995
Electrical
Issued 7 December 1995
Resolved
PROVIDE TRIP GUARD FOR 22OV ELECTRICAL CABLE ON WEATHER DECK AFT.
Condition: Unknown
Due 28 December 1995
Resolved 28 December 1995
Deck/Cargo
Issued 7 December 1995
Resolved
REWORK CARGO PUMP ENGINE AND EMERGENCY GENERATOR REMOTE SHUTDOWNS AND PROVEPROPER OPERATION TO USCG MARINE INSPECTOR.
Condition: Unknown
Due 28 December 1995
Resolved 28 December 1995
Deck/Cargo
Issued 29 November 1994
Resolved
PROVIDE PLUGS FOR FISH PLATE DRAIN HOLES.
Condition: Unknown
Due 30 December 1994
Resolved 3 January 1995
Lifesaving
Issued 29 November 1994
Resolved
REMOVE ALL FLAMMABLES (PAINTS AND VARNISH) FROM VESSEL OR PROVIDE NFPA APPROVED FLAMMABLE STORAGE LOCKER.
Condition: Unknown
Due 30 December 1994
Resolved 3 January 1995
Lifesaving
Issued 29 November 1994
Resolved
PROVIDE WATERTIGHT BOX FOR PYROTECHNICS.
Condition: Unknown
Due 30 December 1994
Resolved 3 January 1995
Lifesaving
Issued 29 November 1994
Resolved
PROVIDE BATTERY FOR ONE DISTRESS MARKER LIGHT.
Condition: Unknown
Due 30 December 1994
Resolved 3 January 1995
Unknown
Issued 20 May 1987
Resolved
VESSEL IS RESTRICTED FROM OCEAN OR COASTWISE ROUTE UNTIL SUCH TIME A VALID LOADLINE CERTIFICATE IS ISSUED TO THE VESSEL.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Documentation
Issued 3 April 1986
Resolved
PROVIDE A VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 3 April 1986
Resolved 3 April 1986
Documentation
Issued 3 April 1986
Resolved
PROVIDE A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY (WATER POLLUTION) ORIGINAL OR CERTIFIED COPY.
Condition: Unknown
Due 3 April 1986
Resolved 3 April 1986