Inspection history · 83
28 July 2025
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8196312
4 October 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7326559
28 April 2020
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6944949
29 September 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6013039
6 May 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5870692
14 March 2016
Deficiency Check · MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5832799
10 November 2015
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5761462
7 November 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5761201
1 June 2015
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5141134
13 April 2015
MTSA Verification · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5101898
25 November 2014
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5029349
12 May 2014
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4856224
18 November 2013
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4754754
4 June 2013
MTSA Verification · Drydock Exam · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4611172
7 November 2012
Drydock Extension · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4480273
23 April 2012
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4293013
1 September 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4132891
6 July 2010
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3782504
6 May 2009
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3467633
10 May 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3204404
28 February 2008
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3155444
18 January 2008
MARPOL Annex I Examination · Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3132886
18 January 2008
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3132975
21 August 2007
Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3034227
30 November 2005
Hull Examination · Internal Structural Exam · COI Inspection · Deficiency Check · Cargo Tank Internal · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2543569
10 November 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2532383
14 June 2005
Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2390021
23 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2365883
9 May 2005
MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2353294
7 September 2004
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2189082
17 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1966053
29 August 2003
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1895029
19 May 2003
Cargo Tank Internal · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1779663
27 June 2002
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1636206
15 June 2001
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 532122
17 May 2001
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1451712
22 May 2000
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1052937
18 May 2000
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1455857
25 May 1999
Hull Examination · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1447965
2 March 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 484424
1 March 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 697859
4 February 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 478461
4 February 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 507850
19 May 1998
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1421513
30 October 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 441383
28 May 1997
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1460089
12 February 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 755386
6 February 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 203415
6 February 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 451748
29 May 1996
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1086278
1 April 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 455329
9 February 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 753540
23 January 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 199185
23 January 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 461038
12 December 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1188202
28 August 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 518511
13 June 1995
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1464595
10 May 1995
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1374214
27 December 1994
Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1389951
26 December 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 43017
5 July 1994
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1175510
22 July 1993
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1151705
29 December 1992
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1139476
6 October 1992
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1248605
15 September 1992
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1264250
30 August 1991
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 938247
14 May 1991
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 901826
1 April 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 457499
10 December 1990
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1228897
27 May 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 505128
6 December 1989
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1238262
12 August 1988
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1349518
19 February 1988
MARPOL Annex II Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1331327
4 January 1988
Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1007127
24 February 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 461045
1 November 1986
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 510657
23 October 1986
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1019931
30 January 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1304844
11 December 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 990401
19 November 1985
Credit Drydock · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1301252
1 October 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 993164
9 July 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 457255
31 October 1984
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 519874
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 28 July 2025
Resolved
An International Load Line Certificate (1966) shall be issued to every ship which has been surveyed and marked in accordance with the present Convention. PSCO unable to verify vessel has been issued required certificate.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 August 2025
Operations/Management › Vessel Activity › Other
Issued 26 August 2016
Resolved
Starting 01OCT2016 this vessel will no longer be allowed to operate until all open deficiencies have been rectified.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2020
Resolution: Vessel is no longer in service cleared deficiency /[name withheld]/
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 14 March 2016
Resolved
Each generator prime mover must have an overspeed device that is independent of the normal operating governor and is adjusted so that the speed cannot exceed the maximum rated speed by more than 15%. Overspeed device was unable to be properly tested at time of periodic inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2016
Resolved 11 April 2016
Resolution: Conducted shutdowns.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 14 March 2016
Resolved
Each prime mover must shut down automaically upon loss of lubricating pressure. Low lube oil shutdown was unable to be properly tested at the time of the inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2016
Resolved 11 April 2016
Resolution: Shutdowns conducted.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 March 2016
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis for crew members on inspected vessels. Employers must maintain records of chemical tests; records shall be sufficient to (1) satisfy the requirements of 46CFR16.210(b) and 46CFR16.220(c) and (2) identify the total number of individuals chemically tested annually.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2016
Resolved 28 March 2016
Resolution: Provided verification of DAPI enrollment
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 March 2016
Resolved
All portable fire extinguishers shall be of an approved type. The portable fire extinguishers shall be installed with an approved manufacturer bracket. Refer to each fire extinguisher to determine the appropriate bracket to use.
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 28 March 2016
Resolution: All extinguisher have the correct mounts
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 14 March 2016
Resolved
The employer shall provide an Empolyee Assitance Program for all crewmembers. Please provide EAP information.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2016
Resolved 28 March 2016
Resolution: Barge has an EAP in place
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 14 March 2016
Resolved
A tank vessel with a capacity of 250 or more barrels that is carrying oil must have under or around each transfer connection point, a fixed container or enclosed deck area. Either move the attached cargo hoses within the containment area or provide additional containment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2016
Resolved 28 March 2016
Resolution: Hoses have been placed inside containment.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 14 March 2016
Resolved
Solid reach rods must be used in tanks containing liquids and the pipe wall sealed with a nonsoluble to prevent penetration of cargo. Replace packing in all reach rods to ensure pipe is sealed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2016
Resolved 28 March 2016
Resolution: Packing has been added to all valves.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 March 2016
Resolved
Piping conveying vapors, gases, or liquids whose temperature exceeds 150 degrees (F) shall be suitable insulated where necessary to preclude injury to personnel. Place lagging on exposed exhaust piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 28 March 2016
Resolution: Lagging has been added to the cargo pump exhaust pipe
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 14 March 2016
Resolved
Each containment area must have a mechanical means of closing each drain and scupper within the containment or enclosed deck area. Drains/scuppers are missing/corroded. Replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2016
Resolved 28 March 2016
Resolution: Scupper plugs have been fixed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 March 2016
Resolved
Barge is not required to have installed guard rails on the main deck. However, the rails that are onboard are broken, missing, or damage and pose a risk to those who are on board. Either fix all railings or remove from barge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 28 March 2016
Resolution: Rails have been fixed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 14 March 2016
Resolved
Remove all damaged and unused hoses and gear from the cargo deck area.
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 28 March 2016
Resolution: All extra hoses and gear has been removed from the barge
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 March 2016
Resolved
All engines shall be of the marine type and suitable for service in the marine environment Install rain guard on the exhaust piping to the generator to prevent water from entering.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 28 March 2016
Resolution: Rain guard has been installed.
Documentation › Certificates/Documents › Stability Letter
Issued 21 January 2016
Resolved
Barge is missing a stability letter. There is no record in USCG databases of a letter.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2020
Resolution: Vessel is no longer in service cleared deficiency /[name withheld]/
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 November 2015
Resolved
Insulations and pipe lagging must be made of approved incombustible materials. The fuel lines for the generator and cargo pump are insulated in a combustible material.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2015
Resolved 3 December 2015
Resolution: All unapproved insulation has been removed from the barge.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 16 November 2015
Resolved
Each hose shall use suitable material in joints and couplings to ensure a leak-free seal. The starboard side cargo hose's flange is leaking cargo onto the deck. Install new gasket on flange.
Condition: Improper/Lack of Maintenance
Due 1 December 2015
Resolved 17 November 2015
Resolution: New gasket was installed on the stbd side cargo hose.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 November 2015
Resolved
All lifebuoys must be marked in block capital letters with the name of the vessel and the name of the homeport. Two lifebuoys are not correctly labeled. Please either bring lifebuoys up to standard or remove since they are in excess of reqs.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2015
Resolution: All of the improperly marked lifebuoys were removed from the vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 November 2015
Resolved
All electrical installations need to be approved by the Coast Guard. Please submit electrical plans to the USCG Marine Safety Center (MSC) for approval.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2020
Resolution: Vessel is no longer in service cleared deficiency /[name withheld]/
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 16 November 2015
Resolved
All mechanical installations need to be approved by the Coast Guard. Please submit plans to the Marine Safety Center (MSC) for approval.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2020
Resolution: Vessel is no longer in service cleared deficiency /[name withheld]/
Construction/Loadline › Hull › Hull Plating
Issued 10 November 2015
Resolved
Barge's forward rake was damaged during allision with pier. Submit repair proposal and conduct approved repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2015
Resolved 18 November 2015
Resolution: The repair proposal was submitted and all repairs were properly completed. An air test was satisfactorily completed on the tank as well.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 10 November 2015
Resolved
Each cargo pump relief valve shall be tested at least once each year to determine they function satisfactorily at the pressure at which they are set to open. Provide proof that the cargo pump's relief valve has been tested in the past year.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2015
Resolved 17 November 2015
Resolution: Vessel had a reciept verifying that the cargo pump relief valve has been serviced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 10 November 2015
Resolved
All cargo tank safety relief valves shall be inspected at least once in every two years. Please provide proof that each cargo tanks pressure vacuum valve has been bench tested within the past two years.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2015
Resolved 18 November 2015
Resolution: Recieved a reciept from Garpo Marine stating that they been tested and that they were working properly.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 10 November 2015
Resolved
The packing for the cargo valve reach rods allows open venting of the cargo tanks. Repair/ replace packing to ensure the "resistance to the action of the liquefied flammable gas (cargo)".
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2015
Resolved 17 November 2015
Resolution: Valve body repacked with string to prevent the open venting of the cargo tanks.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 November 2015
Resolved
The barges navigation lights (side lights) located on the stern of the vessel are the incorrect type. Replace with approved navigation lights or remove if not being used.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2015
Resolved 17 November 2015
Resolution: The improper nav lights were removed from the barge.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 November 2015
Resolved
Barge utilizes portable extension cords to tie in towing vessel power to the barge's electrical distribution system using spliced wires. Each flexible cord and cable must be free of splices or taps. Remove all extension cords connecting tug and barge and remove splices from distribution panel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2015
Resolved 17 November 2015
Resolution: Extension cords were propely removed from the distribution panel onboard the vessel.
Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 10 November 2015
Resolved
Barge currently has a grounded distribution system installed which uses a floating neutral. Tank barges with a distribution system of less than 1000 volts must not have a grounded system. Install ungrounded distribution system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2020
Resolution: Vessel is no longer in service cleared deficiency /[name withheld]/
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 November 2015
Resolved
Each ungrounded system must be provided with a suitable sensitive ground detection system. Install active ground detection system on the 240v and 120v systems.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2020
Resolution: Vessel is no longer in service cleared deficiency /[name withheld]/
Engineering › Fuel Oil Service System › Hose
Issued 10 November 2015
Resolved
Nonmetallic flexible hosed used on fuel systems may not be used in lengths greater than 30 inches. Barge's has nonmetallic flexible fuel lines on prime mover that are greater than 30 inches in length.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2015
Resolved 17 March 2016
Resolution: Hoses have been refitted to the correct size.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 10 November 2015
Resolved
Barge has old flamescreens onboard that are wasted and have holes in them. Remove all unused and damaged flame-screens from the deck.
Action required: 705 - Other - as specified
Due 1 December 2015
Resolved 17 November 2015
Resolution: The broken/damaged flame screen was removed from the vessel.
Construction/Loadline › Hull › Transverse Frame
Issued 1 June 2015
Resolved
Refer to worklist items generated from ISE conducted on 14Apr2015, worklist is contained in Activity #5101898. Items YG1 to YG10 are corrected on 01Jun2015.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2020
Resolution: Vessel is no longer in service cleared deficiency /[name withheld]/
Construction/Loadline › Hull › Bottom Plating
Issued 25 November 2014
Resolved
Inspection team could not complete the ISE on 25Nov2014 due to extensive corrosion/ oxidation along the bottom shell within the void spaces of the entire barge. Spaces are to be made available for inspection prior to 01MAY15.
Action required: 705 - Other - as specified
Due 1 May 2015
Resolved 13 April 2015
Resolution: Spaces were made available for inspection. Additional worklist was created and issued to vessel. V/W items due 14MAY2015; all others prior to next drydock, 31OCT17.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 May 2014
Resolved
Markings on all lifebuoys located on deck, markings are faded and not readable. Identification markings need to be repainted.
Due 14 June 2014
Resolved 19 May 2014
Resolution: Received email with picture showing the markings on the life ring to be legible and satisfactory.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 May 2014
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Balico Marine Service needs to be enrolled in a credited Drug testing program.
Due 2 June 2014
Resolved 27 May 2014
Resolution: Received email from vessel representative with the attached documentation showing that the company Balico Marine Services employees are enrolled with HealthCor Corporate Medical Services a Random Drug and Alcohol testing Program.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 12 May 2014
Resolved
Non-self-propelled barge over 300 GRT that carries hazardous substance as cargo, need to have a valid COFR. COFR on board needs to be under the current owner and operator.
Due 23 June 2014
Resolved 3 June 2014
Resolution: Received email from vessel representative with the attached documentation showing that the company Balico Marine Services COFR is valid and documentation is in order.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 4 June 2013
Resolved
Vessel generator safety trips were not tested, (over speed and lube oil pressure) vessel crewmemeber didnt not know how to properly test safety devices.
Due 6 December 2013
Resolved 13 November 2013
Resolution: Satisfactorily tested lube oil shutdowns and overspeed shutdowns of generators.
Construction/Loadline › Structures › Deck Plating
Issued 7 November 2012
Resolved
# 2 STBD: Aft most bay from fwd, has a pin hole on the very top weld connecting the deck plate and cargo side shell. Needs to be "v" and re-welded.
Action required: 705 - Other - as specified
Resolved 11 December 2012
Resolution: Pin hole has been "v" and welded. Satisfactorily repaired.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 November 2012
Resolved
#1 P - Aft most bay, 3rd long from bottom, totally fractured weld. C/R long and vert SS stiff as marked.
Action required: 705 - Other - as specified
Resolved 11 December 2012
Resolution: SS stiffener and long have been C/R and properly repaired.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 July 2010
Resolved
Vessel operated outside COI expiration period. COI anniversary date is 29 Feb 2008, request for COI annual exam was for 6 July 2010. Request for COI annual exam should have been no later than the 29 May 2010.
Action required: 705 - Other - as specified
Due 6 July 2010
Resolved 6 July 2010
Resolution: Informed/oriented [name withheld] (barge rep) of proper COI inspection intervals.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 18 January 2008
Resolved
33 C.F.R. 155.1070(e) The Coast Guard may require a vessel owner or operator to revise a response plan at any time if it is determined that the response plan does not meet the requirements of this subpart. Notification was faxed within one month of the original submission that the plan was insufficient.
Action required: 705 - Other - as specified
Due 4 February 2008
Resolved 29 February 2008
Resolution: VRP found satisfactory for port of NY, this is a harbor barge.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 18 January 2008
Resolved
Obtain approval from MSC of vessel response plan.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 February 2008
Resolution: Approval provided.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 January 2008
Resolved
Replace / install missing cargo tank cover locking pins.
Condition: Unknown
Due 22 February 2008
Resolved 11 March 2008
Resolution: Pins replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 18 January 2008
Resolved
[name withheld] on all transfer hoses.
Condition: Unknown
Due 22 February 2008
Resolved 29 February 2008
Resolution: Hoses marked.
Construction/Loadline › Hull › Hull Plating
Issued 30 November 2005
Resolved
Bottom has extensive corrison, discovered by mulitple pinholes. Gauging reports show many weak areas in the bottom exceeding 25% WASTAGE. The most critcal areas were cropped and renewed to orginal but the remaing areas shall be cropped as per the agreed 18 month Dry - Dock date of 31 MAY 2007.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 10 October 2007
Resolution: Majority of hull replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 7 September 2004
Resolved
SHOW PROOF OF HYDRO TESTING OF ALL LINES AND HOSES.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2004
Engineering › Fuel Oil Service System
Issued 27 June 2002
Resolved
Properly secure fuel hose from diesel tank to diesel engine. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 15 July 2002
Resolved 2 July 2002
Fire Fighting
Issued 19 May 1998
Resolved
1 of barge's 2 portable CO2 fire extinguishers was overdue to be hydrostatically tested - last tested Mar of 93.
Condition: Unknown
Due 20 May 1998
Resolved 27 May 1998
Accommodation/Occupational Safety
Issued 19 May 1998
Resolved
Bottom of handrail by catwalk in way of Remote Engine Shutdown sign has cracked weld.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Construction/Loadline
Issued 27 December 1994
Resolved
EFFECT PERMANENT REPAIRS WITHIN THE #1 PORT VOID, REPAIRS TO BE IN ACCORDANCE WITH SUBMITTED PROPOSAL AND TO THE STAISFACTION OF THE ATTENDINGOCMI.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Engineering
Issued 15 September 1992
Resolved
INSTALL GUARD OVER V-BELTS ON CARGO PUMP ENGINE.
Condition: Unknown
Due 15 September 1992
Resolved 15 September 1992
Deck/Cargo
Issued 6 December 1989
Resolved
PROVE PROPER OPERATION OF THE CARGO PUMP RELIEF VALVE AND THE CARGO PUMP DISCHARGE PRESSURE GAUGE.
Condition: Unknown
Due 6 December 1989
Resolved 6 December 1989
Construction/Loadline
Issued 6 December 1989
Resolved
REPAINT THE DRAFT MARKINGS FORE AND AFT ON THE STARBOARD SIDE.
Condition: Unknown
Due 6 December 1989
Resolved 6 December 1989
Deck/Cargo
Issued 6 December 1989
Resolved
INSTALL FUEL OIL CONTAINMENT AROUND THE DIESEL PRIME MOVER FUEL OIL TANK.
Condition: Unknown
Due 6 December 1989
Resolved 6 December 1989
Deck/Cargo
Issued 4 January 1988
Resolved
PROVE PROPER OPERATION OF CARGO PUMP SAFETY RELIEF VALVE ON FIRST OFF-LOAD-ING OPERATION.
Condition: Unknown
Due 4 January 1988
Resolved 4 January 1988
Deck/Cargo
Issued 4 January 1988
Resolved
INSTALL SAFETY GUARD AT CARGO PUMP COOLING FAN.
Condition: Unknown
Due 4 January 1988
Resolved 4 January 1988
Construction/Loadline
Issued 19 November 1985
Resolved
GOUGE AND WELD 8" FRACTURE IN NUMBER TWO PORT WING BULKHEAD, TWO FEET BELOW THE DECK.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Construction/Loadline
Issued 19 November 1985
Resolved
CROP AND RENEW SEVEN (7) VERTICAL FRAMES IN NUMBER THREE STARBOARD WING VOID.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Construction/Loadline
Issued 19 November 1985
Resolved
CROP AND RENEW FOUR (4) VERTICAL FRAMES IN NUMBER TWO STARBOARD WING VOID.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Deck/Cargo
Issued 19 November 1985
Resolved
REPLACE MISSING BOLTS AND TIGHTEN ALL BOLTS IN BUTTERWORTH HATCHES.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Deck/Cargo
Issued 19 November 1985
Resolved
REPACK THREE (3) VALVE REACH RODS AT STERN RAKE DECK.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Construction/Loadline
Issued 19 November 1985
Resolved
CROP AND RENEW THREE VERTICAL FRAMES IN NUMBER THREE PORT WING VOID.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Deck/Cargo
Issued 19 November 1985
Resolved
OPEN ALL PRESSURE-VACUUM VALVES FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Deck/Cargo
Issued 19 November 1985
Resolved
REPAIR OR REPLACE PUMP PACKING AS REQUIRED TO STOP LEAKAGE AROUND PUMP SHAFT.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Deck/Cargo
Issued 19 November 1985
Resolved
CLEAN STERN DECK AND CARGO CONTAINMENT AREA OF CARGO RESIDUES.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Construction/Loadline
Issued 19 November 1985
Resolved
CLEAN, GAS FREE AND MAKE AVAILABLE FOR COAST GUARD INSPECTION THE STERN RAKE.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985