MAURY USCG vessel records Sign in
← All vessels

ROYAL PROGRESS

ROYAL PROGRESS is a freight ship. The Coast Guard has recorded 12 inspections since 2001, most recently in February 2024, along with 34 deficiencies and 1 operational control.

Records from 2001 to 2024. Most recent: inspection, 2 February 2024.

Built
Not recorded
Last inspected
2 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7369156 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
510028
Flag
PANAMA
—
Maury page id
psix-510028

Inspections, by type

…with no type recorded3
Years with a record 4 calendar years (2001–2024)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it1987 - Convention (Subpart B), Gross Ton
596 - Convention (Subpart B), Net Ton
1801 - Dead Weight, Metric Ton
2810 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

2 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7859771
7 July 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1838709
5 July 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1835876
8 May 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1802461
1 May 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1784170
29 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1764956
29 January 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1736847
30 December 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1724157
3 July 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1640866
18 June 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1632769
18 January 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1479393
28 December 2001 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1474558

Deficiency record · 34

Construction/Loadline › Structures
Issued 1 May 2003 Resolved
Have class attest to the proper use of materials used in the restoration of the deck house. LEGACY COMPONENT DESC: Deck Plating
Due 1 June 2003
Resolved 7 July 2003
Resolution: Cleared during def check.
Deck/Cargo › Mooring/Anchoring
Issued 1 May 2003 Resolved
Make permanent repairs to the hydraulic lines servicing the winch located weather deck, fwd.
Due 1 June 2003
Resolved 7 July 2003
Resolution: Cleared during def check.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 1 May 2003 Resolved
Have flag state rep attest to the proper operation of the CO2 bottles for the engine room including alarm activation. Bottles are not aligned to allow pull cable to activate all cylinders.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2003
Construction/Loadline › Structures
Issued 1 May 2003 Resolved
Replace wasted deck in engineroom portside forward in way off Ballast Water Manifold and Ballast Tank #4 portside (tank cover). Have Flag State Rep provide gauging report of portside engineroom deck. LEGACY COMPONENT DESC: Deck Plating
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 1 May 2003 Resolved
Recharge or replace portable fire extinguisher forward of the #2 generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2003
Electrical › Electrical Distribution System (service)
Issued 1 May 2003 Resolved
Properly terminate the following dead-end wiring: A. #2 Generator outboard side B. Aft rudder post (steering gear) C. Inboard side of #1 generator D. Battery box aft of #2 generator
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 30 December 2002 Resolved
Repair leaking flange leading to port generator. Flange is presently leaking aggressively.
Due 30 January 2003
Resolved 28 January 2003
Engineering › Freshwater System (cylinder head cooling)
Issued 30 December 2002 Resolved
Replace cover to Main Diesel Engine's Fresh Water Heat Exchanger Pump located stbdside forward in engine room. Missed cover is presently allowing for expose wiring and other electrical components.
Due 30 January 2003
Resolved 28 January 2003
Engineering › Freshwater System (intermediary cooling)
Issued 30 December 2002 Resolved
Install coupling guard for fresh water pump located portside forward engine room. LEGACY COMPONENT DESC: Pump
Due 30 January 2003
Resolved 28 January 2003
Engineering
Issued 30 December 2002 Resolved
Remove or flange off open-end piping located in stbdside of Aft Steering Room.
Due 30 January 2003
Resolved 28 January 2003
Engineering › Steering Gear System
Issued 30 December 2002 Resolved
Remove all deadend wiring located stbdside of aft steering room.
Due 30 January 2003
Resolved 28 January 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 30 December 2002 Resolved
Properly secure oxgen acelene cylinders on main deck.
Due 30 January 2003
Resolved 28 January 2003
Construction/Loadline › Penetrations
Issued 30 December 2002 Resolved
Have class address piping penetration on aft starboard side of vestibule leading to engineroom and cargo hatches on weatherdeck. Pipe penetration leaves accessive opening around penetration making for weathertight integrity issues.
Due 30 January 2003
Resolved 19 February 2003
Resolution: Received report from flag state representative to clear outstanding def.
Construction/Loadline › Penetrations
Issued 30 December 2002 Resolved
Make permanent/proper repairs to through hole in bulkhead between top tank deck and engineroom. Bulkhead is a watertight bulkhead.
Due 30 January 2003
Resolved 3 January 2003
Resolution: Class faxed in survey report of repairs.
Personnel › Manning/Qualifications
Issued 3 July 2002 Resolved
Man the vessel IAW the Safe Manning Certificate. Current Chief Engineer and 2 ABs were not qualified/certified under STCW 78/95. LEGACY COMPONENT DESC: Minimum Safe Manning
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 3 July 2002
Resolved 15 July 2002
Lifesaving › Lifeboat
Issued 3 July 2002 Resolved
Owner/operator altered the lifesaving arrangement without class/flag approval. Provide class/flag approval for current installation/arrangement. LEGACY COMPONENT DESC: Carriage Requirement
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 3 July 2002
Resolved 15 July 2002
Pollution Prevention/Response › Prevention Equipment
Issued 3 July 2002 Resolved
Make repairs to OWS and provide manufacturer information attesting to the installed device's sensor. The pump is broken and the acting chief engineer stated that he thought that the installation was a 100ppm device. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 3 July 2002
Resolved 15 July 2002
Resolution: Replaced entire OWS system.
Electrical › Electrical Distribution System (service)
Issued 3 July 2002 Resolved
Provide non-conductive matting for the Main Distribution Panel. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 July 2002
Resolved 15 July 2002
Fire Fighting › Fire Hoses
Issued 3 July 2002 Resolved
Provide a fully equipped fire station in the engine room as indicated on the Fire Control Plan. There is currently no hose, nozzle, or spanner. LEGACY COMPONENT DESC: Number
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 July 2002
Resolved 15 July 2002
Fire Fighting › Structural - B Class Divisions
Issued 3 July 2002 Resolved
Repair the class B accomodation bulkheads where the AC control lines penetrate the bulkheads. LEGACY COMPONENT DESC: Bulkheads - Accommodation Spaces
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 3 July 2002
Resolved 15 July 2002
Pollution Prevention/Response › Prevention Equipment
Issued 3 July 2002 Resolved
Install an approved sanitation device IWO the chief mate's and chief engineer's toilets. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 3 July 2002
Resolved 15 July 2002
Documentation › Logs/Records
Issued 3 July 2002 Resolved
Provide proof of the vessel's last drydock survey. LEGACY COMPONENT DESC: Enhanced Survey Report File
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 July 2002
Resolved 15 July 2002
Deck/Cargo › Cargo Stowage
Issued 3 July 2002 Resolved
Properly prepare vehicles for transportation IAW 49 CFR 176.905, or 49 CFR 173.220.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 3 July 2002
Resolved 15 July 2002
Resolution: Received HAZMAT training and is now in compliance.
Personnel › Training
Issued 3 July 2002 Resolved
Provide training of HAZMAT Employees IAW 49 CFR 172.704. LEGACY COMPONENT DESC: Familiarization Training
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 July 2002
Resolved 15 July 2002
Engineering
Issued 31 December 2001 Resolved
Remove oil from deck and bilges in all machinery spaces in accordance with SOLAS 74/78 II-2/15. LEGACY COMPONENT DESC: Bilges
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2002
Resolved 18 January 2002
Resolution: Vessel removed all oil from deck and bilges in machinery spaces.
Electrical › Electric Generation Source (service)
Issued 31 December 2001 Resolved
Provide missing safety guards on rotating parts for #1 ship service generator in accordance with SOLAS 74.78 II-1/26.1. LEGACY COMPONENT DESC: Safety Guards
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2002
Resolved 18 January 2002
Resolution: Vessel replaced missing guards for rotating parts on #1 shis servive generator.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 31 December 2001 Resolved
Properly repair fuel drains on main diesel engine in accordance with SOLAS 74/78 II-2/33. LEGACY COMPONENT DESC: Fuel Return Line
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 18 June 2002
Resolution: Piping repaired with new fittings
Navigation › Piloting/Steering
Issued 31 December 2001 Resolved
Provide a rudder indicator in the steering compartment in accordance with SOLAS 74/78 II-1/29.12. LEGACY COMPONENT DESC: Rudder Angle Indicator
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2002
Resolved 18 January 2002
Resolution: Vessel provided Rudder Angle Indicator in Aft Steering.
Navigation › Piloting/Steering
Issued 31 December 2001 Resolved
Provide emergency steering instructions in the steering compartment in accordance with SOLAS 74/78 II-1/19.2(c). LEGACY COMPONENT DESC: Emergency Steering Instructions
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2002
Resolved 18 January 2002
Resolution: Vessel provided Emergency Steering Instructionsin Aft Steering.
Navigation › Piloting/Steering
Issued 31 December 2001 Resolved
Prove proper operation of control of steering gear from the steering gear compartment in accordance with SOLAS 74/78 II-1/7.3. LEGACY COMPONENT DESC: Steering Gear Controls
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2002
Resolved 18 January 2002
Resolution: Vessel demonstrated Steering Gear control from Aft Steering compartment.
Electrical › Electrical Distribution System (service)
Issued 31 December 2001 Resolved
Repair broken electrical panel door in main deck compartment, port side aft in accordance with SOLAS 74/78 II-1/45.1. LEGACY COMPONENT DESC: Panel Door
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2002
Resolved 18 January 2002
Resolution: Vessel made repairs to and installed electrical panel door.
Deck/Cargo › Holds/Tanks
Issued 31 December 2001 Resolved
At next drydock, repair & ensure that all cargo deck hatchs are watertight in accordance with ILLC 66, Annex 15. LEGACY COMPONENT DESC: Hatch Cover
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 18 June 2002
Resolution: New cargo deck hatch latches installed.
Electrical › Lighting (service)
Issued 31 December 2001 Resolved
At the next drydock, replace or repair all broken light fixtures throughout the vessel in accordance with SOLAS 74/78 II-1/54.1 LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 18 June 2002
Resolution: All broken light fixtures throughout vessel were repaired.
Construction/Loadline › Structures
Issued 31 December 2001 Resolved
At next drydock, repair all weather deck doors to ensure watertightness in accordance with ILLC 66, Annex 15. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 18 June 2002
Resolution: Doors and gaskets renewed.

Ownership record