MAURY USCG vessel records
← All vessels

STC 2506

STC 2506 is a 1962 tank barge. The Coast Guard has recorded 78 inspections since 1984, most recently in June 1998, along with 20 deficiencies.

Records from 1984 to 1998. Most recent: inspection, 17 June 1998.

Built
1962
Last inspected
17 June 1998
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 17 June 1998
…with no type recorded43
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1984–1998)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-51004

Documentation record

Tonnage as PSIX records it1512 - Regulatory (Subpart C or D), Gross Ton
1512 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 12

Inspection history · 78

17 June 1998 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 89704
14 March 1996 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 885681
8 December 1995 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 463822
1 August 1995 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1189980
26 April 1995 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 484382
4 April 1995 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1156205
17 January 1995 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1142078
3 October 1994 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 642175
28 September 1994 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1176115
21 September 1994 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 96531
21 September 1994 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 370740
21 September 1994 Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1180815
29 June 1994 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 493062
2 June 1994 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1013626
1 June 1994 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 443087
13 January 1994 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1162464
22 July 1993 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 520516
12 May 1993 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 827326
7 May 1993 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1133941
18 November 1992 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 534511
21 September 1992 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 489363
29 July 1992 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 946715
16 March 1992 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1011878
28 February 1992 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 453486
28 February 1992 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1253061
2 January 1992 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 444351
30 December 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 499687
29 May 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 456325
17 May 1991 Hull Examination · Examination of Repairs · COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1230450
6 February 1991 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1219857
26 September 1990 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 927228
21 September 1990 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 931418
16 May 1990 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 931404
5 April 1990 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 927185
4 December 1989 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 444334
29 November 1989 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 522072
6 November 1989 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1018966
4 October 1989 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1322083
7 September 1989 Examination of Repairs · Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1200125
26 May 1989 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 479913
22 December 1988 Damage Survey · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1342514
16 November 1988 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 448736
22 August 1988 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1345471
15 April 1988 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1031604
21 March 1988 Examination of Repairs · Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 985749
5 February 1988 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1326427
14 January 1988 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 462824
16 October 1987 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1323879
7 July 1987 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 473942
2 June 1987 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 531392
1 June 1987 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1335253
3 April 1987 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1329764
30 March 1987 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 491080
13 March 1987 Examination of Repairs · Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1324524
20 February 1987 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 540027
14 January 1987 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1317645
14 December 1986 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1023931
13 November 1986 Type not recorded
No type recorded · MSO CINCINNATI · Activity 437862
28 August 1986 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 466612
8 August 1986 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 998440
17 July 1986 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 988020
30 June 1986 Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1304828
13 March 1986 Re-Inspection · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1300080
20 September 1985 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1301418
13 September 1985 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 535803
6 September 1985 Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1300528
5 September 1985 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 527440
29 August 1985 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 441007
22 March 1985 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1290271
10 January 1985 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 977997
16 November 1984 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 445168
24 October 1984 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 518488
16 October 1984 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 537430
15 October 1984 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 476038
20 August 1984 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 532616
18 August 1984 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 506709
2 August 1984 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 516517
11 July 1984 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 468945

Deficiency record · 20

Construction/Loadline
Issued 21 September 1994 Resolved
PRIOR TO NEXT LOADING MAKE PERMANENT REPAIRS TO THE SIDE OF 2S TANK 6 FT FROM DECK LEVEL, 8 FT FWD OF AFT BHD.
Condition: Unknown
Due 21 October 1994
Resolved 28 September 1994
Deck/Cargo
Issued 28 February 1992 Resolved
Replace broken dog on ullage hatch cover to #5 port cargo tank prior to compliance date.
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992
Deck/Cargo
Issued 28 February 1992 Resolved
Replace missing gasket on ullage opening to #3 port cargo tank prior to thecompliance date.
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992
Construction/Loadline
Issued 17 May 1991 Resolved
MANY SIDE VERTICAL CHORD MEMBERS AND RELATED FRAMING WAS BUCKLED IN ALL CARGO TANKS. ALL DAMAGED FRAMING WAS REPAIRED TO THE SATISFACTION OF THE COGNIZANT O.C.M.I._x001C_
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Deck/Cargo
Issued 26 September 1990 Resolved
PRIOR TO LOADING CARGO, PRESENT VESSEL FOR COMPLETE COAST GUARD INTERNAL STRUCTURAL AND CARGO TANK INTERNAL EXAMINATION.
Condition: Unknown
Due 26 September 1990
Resolved 26 September 1990
Deck/Cargo
Issued 26 September 1990 Resolved
PRIOR TO LOADING CARGO, CONDUCT THE ANNUAL CARGO PIPING TEST.
Condition: Unknown
Due 26 September 1990
Resolved 26 September 1990
Deck/Cargo
Issued 26 September 1990 Resolved
PRIOR TO LOADING CARGO, OPEN THE VESSEL'S PV VALVES FOR INSPECTION BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 26 September 1990
Resolved 26 September 1990
Construction/Loadline
Issued 5 April 1990 Resolved
PRIOR TO CARRYING CARGO CROP AND RENEW BACK TO ORIGINAL BOTTOM HULL PLATING AS INDICATED TO OWNER REP. IN WAY OF SEVERELY PITTED AREAS.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Deck/Cargo
Issued 4 October 1989 Resolved
MAKE PERMANENT REPAIRS TO THE FRACTURE IN WAY OF THE #3 CARGO TANK BILGE KNUCKLE APPROX 1FT AFT OF #3 BLKHD.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 3 April 1987 Resolved
PERMANENTLY REPAIR PORT BOW TIMBERHEAD AT NEXT GAS-FREE AVAILABILITY BUT NOT LATER THAN 03 OCT 87.
Condition: Unknown
Due 3 April 1987
Resolved 3 April 1987
Construction/Loadline
Issued 14 December 1986 Resolved
PERMANENTLY REPAIR CARGO LEAK IN WAY OF #3 PORT CARGO TANK, PRIOR TO LOAD- ING CARGO IN THAT TANK, BUT NOT LATER THAN 14JAN87.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Construction/Loadline
Issued 30 June 1986 Resolved
MAKE PERMANENT REPAIRS TO STBD. SIDE SHELL IN WAY OF #5 CARGO TANK.SIDE SHELL IS FRACTURED APPROX.5 FEET ABOVE THE LIGHTSHIP WATERLINE.REPAIRS ARE TO BE COMPLETED PRIOR TO THE CARRIAGE OF CARGO AND TO THE SATISFACTION OF THER COGNIZANT OCMI.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Construction/Loadline
Issued 6 September 1985 Resolved
MAINTAIN TEMPORARY REPAIRS TO THE RIPPED TIMBERHEAD ON THE STARBOARD BOW. MAKE PERMANENT REPAIRS NOT LATER THAN 06OCT85.
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Construction/Loadline
Issued 22 March 1985 Resolved
MADE PERMANENT REPAIRS TO PORT STERN SIDE SHELL WITH A 4'X1/2"X3' AND A 1'X3/4"X7' INSERTS. AIR TESTED FOR SOUNDNESS.
Condition: Unknown
Due 22 March 1985
Resolved 22 March 1985
Construction/Loadline
Issued 10 January 1985 Resolved
LOCATE AND MAKE PERMANENT REPAIR(S) TO LEAK IN COFFERDAM.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Construction/Loadline
Issued 10 January 1985 Resolved
MAKE PERMANENT REPAIR TO 4 INCH PUNCTURE IN SIDE SHELL(STBD) NEAR HEADLOG IN FWD RAKE.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Deck/Cargo
Issued 10 January 1985 Resolved
INSTALL NEW EXHAUST PIPE ON CARGO PUMP ENGINE. EXISTING PIPE IS FRACTURED.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Construction/Loadline
Issued 10 January 1985 Resolved
AFFIX DRAFT MARKS TO HULL.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Deck/Cargo
Issued 10 January 1985 Resolved
PROVE OPERATION OF CARGO PUMP RELIEF VALVE AND ACCURACY OF CARGO PUMP DISCHARGE GAUGE.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Deck/Cargo
Issued 10 January 1985 Resolved
TEST CARGO PIPING TO 100PSI.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985

Ownership record