ANNIE GIRL

ANNIE GIRL is a 2002 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 2002, most recently in July 2026, along with 56 deficiencies and 1 casualty investigation in 2018.

Records from 2002 to 2026. Most recent: inspection, 28 July 2026.

Built
2002
Last inspected
28 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN9100
510303
Flag
UNITED STATES
369112000
Maury page id
psix-510303

Inspections, by type

…with no type recorded4
Years with a record 22 calendar years (2002–2026)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.0 ft × 19.0 ft × 7.6 ft
Registered tonnagegross 59 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRESMONDO BOAT WORKS INC · PERDIDO, AL, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Simplified, Gross Ton
47 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ3437MMSI 369112000 · active · compulsorily equipped · granted 1 May 2025, expires 1 May 2035
WDN9100MMSI 369112000 · cancelled · voluntarily equipped · granted 11 July 2023, cancelled 23 April 2025
WDG7499MMSI 369112000 · terminated · compulsorily equipped · granted 29 March 2013, cancelled 25 May 2023
WDA7755MMSI 369112000 · expired · compulsorily equipped · granted 12 April 2002, cancelled 16 June 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 52

28 July 2026 Type not recorded
No type recorded · USCGC OLIVIA HOOKER (WPC 1161) · USCG Heartland District (CGD-H) · Activity 8455217
9 April 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8345175
19 February 2026 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8302242
10 April 2025 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8109548
24 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7900912
15 March 2024 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7879707
29 February 2024 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7875021
7 November 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7824087
28 June 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7725957
22 May 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7686987
12 July 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7505611
12 May 2022 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7622846
8 March 2022 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7407230
25 January 2022 Hull Examination · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7385359
7 October 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7328330
3 May 2021 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7188392
5 February 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7138726
16 July 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7007625
5 June 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6968714
17 January 2020 Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6891357
5 November 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6849469
17 October 2019 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6835884
6 March 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6637330
12 April 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6390185
12 March 2018 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6370291
16 February 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6379664
23 January 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6342398
9 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6142848
8 March 2017 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6101210
15 January 2016 Administrative Inspection · Deficiency Check · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5798455
20 March 2014 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4815101
10 February 2012 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4242005
23 January 2012 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4229692
25 March 2010 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3694643
26 March 2009 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3430562
1 April 2008 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3303154
27 March 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3167099
30 April 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2919268
22 March 2007 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2883565
26 April 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2616702
28 March 2006 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2610929
14 March 2006 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2564066
16 September 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2494315
14 February 2005 Deficiency Check · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2292486
27 February 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2014410
11 February 2004 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2005013
28 July 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1873142
23 June 2003 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1824812
23 June 2003 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1825892
15 April 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1763713
17 April 2002 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1606866
4 April 2002 Simplified Stability Test
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1605300

Deficiency record · 56

05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 10 April 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2025
Resolution: Received scan of FCC Station License.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 22 May 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's Radio Station and Radio Telephony Certificate were expired. Vessel needs new FCC certificates issued.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 25 July 2023
Resolution: FCC Radiotelephony certificate received.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 June 2020 Resolved
Vessel has a valid radio safety certificate, however vessel is not in full compliance with FCC requirements of 47 CFR 80 Sub part "S". Issues noted, radio log, reserve power source, call sign on emergency placard, remote control at each operating station, documents posted, MMSI number programed on radios, no distress on HF, Part 80 not available, etc. Provide new radio safety certificate and copy of form used to complete inspection, I.E. how to conduct an inspection of a small passenger vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 5 February 2021
Resolution: Vessel had MMSI properly programmed in VHF radio, and provided new FCC registration.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 June 2020 Resolved
Provide charts for operating area. Approaches, Gulf of Mexico, and Inland.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 5 February 2021
Resolution: Vessel procured new charts for op area.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2020 Resolved
Provide means to lock sanitation discharge overboard valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 5 February 2021
Resolution: Vessel placed padlock on MSD discharge overboard valve, securing handle from accidental opening.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 June 2020 Resolved
Each floating water light must be approved in accordance with 33 CFR "Q" specs. Fix broken water light bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 5 February 2021
Resolution: Broken water light bracket was replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 9 June 2020 Resolved
Generator must be derated to 80% of max capacity with placard installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 5 February 2021
Resolution: O/O installed new breakers, rated at 80% max capacity.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 9 June 2020 Resolved
Vessel must have fire detection system serviced annually by certified technician.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 29 February 2024
Resolution: Inspector observed fire detection system service paperwork.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 9 June 2020 Resolved
Engine room bilge alarm was not audible at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 5 February 2021
Resolution: Engine room bilge operation was audible at wheel house.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2020 Resolved
Ensure portable bilge pump is capable of removing water from all watertight compartments. Pump had leak in discharge hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 5 February 2021
Resolution: portable pump was installed with new discharge hose.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 June 2020 Resolved
Emergency hatch missing escape ladder in case of emergency evacuation. All vessels shall have two means of escape from space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 13 August 2020
Resolution: Vessel owner [name withheld] provided objective evidence clearing deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2020 Resolved
Inspect all cable, wiring, and accessories. Test all circuit breakers by manual operation. Breakers at main panel on bridge were broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 5 February 2021
Resolution: Installed new breakers on panel in wheel house. previous ones were broken.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 October 2019 Resolved
The owner or managing operator must be prepared to conduct test and have the vessel ready for inspection including inspection and testing of all smoke and fire detection systems. Noted that operator could not test fire detection system. Provide servicing certificate and test operational.
Action required: 705 - Other - as specified
Due 24 October 2019
Resolved 5 November 2019
Resolution: Fire Detection System tested, all zones identified correctly and all inputs tested satisfactory. The system maintenance by a Technical professional will be witnessed by USCG at annual inspection or the servicing certificate will be provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 17 October 2019 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information. Noted no emergency broadcast placard for SSB radio. Post appropriate placard.
Action required: 705 - Other - as specified
Due 24 October 2019
Resolved 25 October 2019
Resolution: Properly updated and posted the emergency broastcast placard.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 October 2019 Resolved
Machinery, equipment, materials, and arrangements not covered by standards may be inspected with standards acceptable to [name withheld] A/C suction valve handle, replace hose, and install hose clamps on both ends.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2019
Resolution: satisfactorily replaced components and properly installed clamps
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 17 October 2019 Resolved
Scuppers or freeing ports for the cockpit deck of a cockput vessel must be located to allow rapid clearing of water in all probable conditions of list and trim. Noted that freeing ports on port and starboard deck were covered. Remove freeing port covers. Completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2019
Resolution: Removed freeing port covers.
Communications › Radio Communications › VHF Radiotelephone
Issued 19 March 2018 Resolved
Program MMSI number into radio
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 April 2018
Resolved 2 April 2018
Resolution: MMSI inputed into radio
Documentation › Logs/Records › Logbook (official)
Issued 19 March 2018 Resolved
Properly document drills, management, and maintenance of all safety and fire fighting equipment
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 April 2018
Resolved 23 March 2018
Resolution: Logs have been updated and maintained
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 19 March 2018 Resolved
Install proper UL 217 detectors in accommodation space
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 April 2018
Resolved 23 March 2018
Resolution: Correct detectors installed
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 24 March 2017 Resolved
Update call sign on FCC safety certificate. 47 CFR 80.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 9 May 2017
Resolution: Call Sign updated.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 March 2017 Resolved
Need supervisory training for all supervisory personnel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 9 May 2017
Resolution: Proof of supervisory training provided.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 24 March 2017 Resolved
Replace 02 smoke detectors in accomodation spaces with UL217 type detectors.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 9 May 2017
Resolution: New smoke detectors added.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 24 March 2017 Resolved
Replace batteries in lifejackets lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 9 May 2017
Resolution: All life jacket lights replaced with new.
Communications › Radio Communications › VHF Radiotelephone
Issued 24 March 2017 Resolved
Need radio log IAW 47 CFR 80.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 9 May 2017
Resolution: VHF Radio connected to GPS.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 24 March 2017 Resolved
Need copy of colregs, inland rules on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 9 May 2017
Resolution: Provided updated Inland Navigation Rules.
Communications › Radio Communications › VHF Radiotelephone
Issued 24 March 2017 Resolved
Need GPS installed on VHF radio IAW 47 CFR 80.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 9 May 2017
Resolution: GPS connected to VHF radio.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 22 March 2016 Resolved
Vessel had no emergency instructions on board or posted at operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 22 March 2016
Resolution: Vessel printed and posted emergency instructions at the operating station.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 March 2016 Resolved
Dead ended wires found in tank room on port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 22 March 2016
Resolution: Vessel properly capped and enclosed wires in junction box.
Accommodation/Occupational Safety › Potable Water System › General
Issued 26 January 2016 Resolved
Cap off 03 PVC pipes.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2016
Resolved 22 March 2016
Resolution: Capped pipes
Engineering › Pressure Vessel › Relief Valve
Issued 26 January 2016 Resolved
Vessel had a water heater with a pressure relief valve setting of 150 PSI. Replace with pressure relief valve set at 100PSI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 March 2016
Resolved 22 March 2016
Resolution: Replaced relief valve.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 January 2016 Resolved
Guards over rotating machinery were removed. Replace guards.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2016
Resolved 22 March 2016
Resolution: Replaced guards.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 January 2016 Resolved
White electrical wire was not properly supported. Place a metal hanger at least every 24 inches as needed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2016
Resolved 22 March 2016
Resolution: Installed Adel clamp.
Accommodation/Occupational Safety › Ventilation › General
Issued 26 January 2016 Resolved
Clamp on AC line was damaged. Replace clamp.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2016
Resolved 22 March 2016
Resolution: Replaced clamp
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 March 2014 Resolved
Floating waterlight and lifeline must be attached to life ring buoy in accordance with 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 20 April 2014
Resolved 15 April 2014
Resolution: Floating waterlight and lifeline were properly attached to life ring buoy. Deficency Cleared.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 February 2012 Resolved
Prove the proper operation of the float light provided for the ring buoy IAW 46 CFR 180.70.
Condition: Damaged By Earlier Event
Due 14 April 2012
Resolved 3 April 2012
Engineering › Bilge Water Management System › Pump
Issued 10 February 2012 Resolved
Provide a method of dewatering the space forward of the collision bulkhead IAW 46 CFR 182.520.
Condition: Improper Installation
Due 14 April 2012
Resolved 3 April 2012
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 10 February 2012 Resolved
Provide data in way of the generator set to determine the need of a pre-engineer fix gas fire extinguishing system IAW 46 CFR 182.520.
Due 14 April 2012
Resolved 3 April 2012
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 February 2012 Resolved
Replace deteriorated hoses on both main engines in way of the exhaust cooling IAW 46 CFR 176.800.
Condition: Damaged By Earlier Event
Due 14 April 2012
Resolved 3 April 2012
Navigation › Piloting/Steering › Magnetic Compass
Issued 22 March 2007 Resolved
Provide and install a illuminated magnetic compass as required by 46 CFR 184.402
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 17 April 2007
Resolution: Provided a illuminated magnetic compass as required by 46 CFR 184.402.
Documentation › Logs/Records › Logbook (official)
Issued 22 March 2007 Resolved
Provide for review a lifesaving equipment maintenance record as required by 46 CFR 185.702
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 17 April 2007
Resolution: Provided an appropriate lifesaving equipment maintenance record as required by 46 CFR 185.702.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 March 2007 Resolved
Provide and place on board vessel a first aid kit as required by 46 CFR 184.710
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 17 April 2007
Resolution: Provided a Coast Guard approved first aid kit as required by 46 CFR 184.710.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 22 March 2007 Resolved
Derate the ships service generators as required by 46 CFR 183.320(b)(2)
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 17 April 2007
Resolution: Derated the ships service generator as required by 46 CFR 183.320(b)(2).
Lifesaving › Lifefloat › Painter
Issued 22 March 2007 Resolved
Properly run the painter line for a float free arrangement as required by 46 CFR 180.130
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2007
Resolved 22 March 2007
Resolution: Properly ran the painter line for a float free arrangement
Lifesaving › Lifebuoys › Serviceable
Issued 28 March 2006 Resolved
Replace the grabline on the lifering in accordance with 46CFR180.70
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 26 April 2006
Resolution: Replaced the grabline on the lifering
Construction/Loadline › Penetrations › Pipe Flange
Issued 28 March 2006 Resolved
Make repairs to the check valve that drains the icemaker cooling water. 46CFR179.350
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 26 April 2006
Resolution: Made repairs to the check valve
Stability › Watertight Integrity › General
Issued 14 March 2006 Resolved
Renew ball valve for live well tank raw water sea suction as required by 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 14 March 2006
Resolution: Replaced ball valve for live well tank and found satisfactory.
Engineering › Steering Gear System › Ram
Issued 14 March 2006 Resolved
Repair hydraulic leak on the steering ram and prove satisfactory operation of system as required by 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 14 March 2006
Resolution: Witnessed satisfactory repair and operation of hydraulic system for steering ram.
Personnel › Training › First Aid/CPR
Issued 15 February 2005 Resolved
Provide proof of CPR/First Aid training for 50% of crew IAW NVIC 1-91
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2005
Resolved 23 February 2005
Resolution: Valid cards were provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 14 February 2005 Resolved
Repair electrical propulsion controls from tuna tower IAW 46 CFR 176.804
Action required: 705 - Other - as specified
Due 16 March 2005
Resolved 16 February 2005
Resolution: Controls were repaired and operationally tested...SAT.
Engineering › Steering Gear System
Issued 23 June 2003 Resolved
Provide documentation attesting to proper operation of electronic propulsion control. Documentation shall address failure of propulsion control on 6/23/03 & steps taken to remedy potential problem.
Due 24 July 2003
Resolved 28 July 2003
Resolution: Documentation provided.
Engineering › Steering Gear System
Issued 23 June 2003 Resolved
Demonstrate satisfactory operation of electronic propulsion control from all conning stations.
Due 24 July 2003
Resolved 28 July 2003
Resolution: Op test completed. Test satisfactory.
Fire Fighting › Means of Escape
Issued 23 June 2003 Resolved
Repair and/or replace damaged handrail on the port bow in accordance with 46 CFR 177.900. LEGACY COMPONENT DESC: Handrails/Handholds
Due 24 July 2003
Resolved 24 June 2003
Resolution: Handrail damaged repaired to as original.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 April 2002 Resolved
Provide railing around cockpit that is thirty six inches high. as required by 46 CFR 177.900 (d) (3) (4). LEGACY COMPONENT DESC: Deck Rail
Due 26 April 2002
Resolved 19 April 2002
Resolution: Stainless steel cable installed on 1" aluminum tubes stantions at a height of thirty six inches.
Navigation › Collision/Grounding Avoidance
Issued 18 April 2002 Resolved
Properly install anchor light so that it is visible for 360 degrees. As required by 33 CFR part 81. LEGACY COMPONENT DESC: Navigation Lights
Due 26 April 2002
Resolved 20 April 2002
Construction/Loadline › Structures
Issued 18 April 2002 Resolved
Arrange freeing ports to allow rapid draining "flush with main deck" as required by 46 CFR 178.420 LEGACY COMPONENT DESC: Scupper
Condition: Design Flaw
Due 26 April 2002
Resolved 20 April 2002
Communications › Visual Communication
Issued 18 April 2002 Resolved
Mark area forward of Cockpit port and starboard side with signs indicating no passengers beyond this point as required by 46 CFR 177.900. LEGACY COMPONENT DESC: Warning Sign (gangway)
Due 26 April 2002
Resolved 20 April 2002

Casualty record · 1

16 February 2018Routine · role: Involved in a Marine Casualty · activity 6379664
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.