This record may be incomplete: the most recent inspection recorded for this vessel was 39 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it1228 - Regulatory (Subpart C or D), Gross Ton 1228 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 8 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
10 December 1987Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006648
13 November 1986Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327158
4 November 1986Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1012309
10 September 1986Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1311029
18 August 1986COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 989245
10 May 1985Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 983475
25 February 1985Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 978705
27 January 1985Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979122
INSTALL GUARDS ON BOTH ENDS OF GENERATORS DRIVE DIESEL.
Condition: Unknown
Due 18 August 1986
Resolved 18 August 1986
Electrical
Issued 18 August 1986Resolved
REMOVE FROM VESSEL OR PERMANENTLY INSTALL ELECTRICAL STOVE.
Condition: Unknown
Due 18 August 1986
Resolved 18 August 1986
Electrical
Issued 18 August 1986Resolved
REMOVE TEMPORARY WIRING FROM BATTERIES AND REINSTALL PROPERLY. PROVIDE PROPER CIRCUIT BREAKER, CABLING AND STUFFING TUBES.
Condition: Unknown
Due 18 August 1986
Resolved 18 August 1986
Electrical
Issued 18 August 1986Resolved
INSTALL PROPER METHOD OF SUPPORTING ELECTRICAL CABLING TO GENERATOR AND SECURE STUFFING TUBES ON GENERATOR.
Condition: Unknown
Due 18 August 1986
Resolved 18 August 1986
Engineering
Issued 18 August 1986Resolved
SANDBLAST AND GUAGE THICKNESS OF AIR RECEIVER. DEMONSTRATE PRIOR COAST GUARD APPROVAL OF SAME, PRIOR TO COMPLETION OF NEXT DRYDOCKING.
Condition: Unknown
Due 18 August 1986
Resolved 18 August 1986
Construction/Loadline
Issued 18 August 1986Resolved
PAINT DRAFT MARKS AND VESSEL NAME ON HULL.
Condition: Unknown
Due 18 August 1986
Resolved 18 August 1986
Engineering
Issued 18 August 1986Resolved
HYDROTEST AIR RECEIVERS TO 1 1/4 MAWP.
Condition: Unknown
Due 18 August 1986
Resolved 18 August 1986
Deck/Cargo
Issued 18 August 1986Resolved
HYDROTEST AND LOG ALL CARGO PIPING AND HOSES TO 225 PSIG.
Condition: Unknown
Due 18 August 1986
Resolved 18 August 1986
Fire Fighting
Issued 10 May 1985Resolved
PROVIDE ONE BV SEMI-PORTABLE FIRE EXTINGUISHER (DOUBLE IF CO2 OR DRY CHEMICAL) FOR USE ON MAIN DECK.
Condition: Unknown
Due 31 May 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 27 January 1985Resolved
VESSEL IS NOT PERMITTED TO CARRY CARGO IN #3 STARBOARD CARGO TANK OR #2 PORT CARGO TANK.
Condition: Unknown
Due 27 January 1985
Resolved 27 January 1985
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.