MAURY USCG vessel records Sign in
← All vessels

SEA-LAND DEFENDER

SEA-LAND DEFENDER is a 1980 freight ship. The Coast Guard has recorded 13 inspections since 2003, most recently in March 2007, along with 6 deficiencies and 1 operational control.

Records from 2003 to 2007. Most recent: inspection, 19 March 2007.

Built
1980
Last inspected
19 March 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

510437
Flag
MARSHALL ISLANDS
—
Maury page id
psix-510437

Inspections, by type

…with no type recorded7
Years with a record 4 calendar years (2003–2007)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it32629 - Convention (Subpart B), Gross Ton
13998 - Convention (Subpart B), Net Ton
35801 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

19 March 2007 Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2867881
6 March 2007 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2882814
3 February 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2866765
19 October 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2803785
30 May 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2664535
28 May 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2662850
27 February 2006 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2592483
2 January 2006 MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2559171
1 March 2005 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2301486
17 December 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1965561
30 July 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1861357
3 May 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1997770
13 March 2003 Type not recorded
No type recorded · GROUP LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1756608

Deficiency record · 6

Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 3 February 2007 Resolved
Missing any matting to prevent shock. SOLAS 1974, Chap II-1, Reg. 27 50A
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2007
Resolved 25 February 2007
Resolution: Electrical panels were insulated with rubber matting with a width of 920 mm along the entire main switchboard and group stater panels and considered satisfactory at this time.
Engineering › Lubricating Oil Service System › Manifold
Issued 3 February 2007 Resolved
Areas of excessive fuel/oil or lube oil leakage at the following locations: #3 fuel oil purifier manifold, #3 & #7 Main diesel engine cylinders (both main generators) SOLAS 1974, Chap II-2, Reg 27, 17A/C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 3 February 2007
Resolution: received photos electronically attesting to proper cleaning of specified areas.
Engineering › Steam System (auxiliary) › Piping
Issued 3 February 2007 Resolved
Sream pipe leaking in engine room, bottom deck, fwd/port corner. SOLAS 2004, Chap 1, reg 11 50A
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2007
Resolved 25 February 2007
Resolution: The above leaking steam pipe was found repaired by replacement of defective flange gasket and considered satisfactory.
Accommodation/Occupational Safety › Messroom › Location
Issued 3 February 2007 Resolved
Permanently mounted rail (tray) interferes with securing ventilation in galley between messroom SOLAS 1974, Chap II-2, Reg 27 50A
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 March 2007
Resolved 25 February 2007
Resolution: The one permanently mounted food tray on the shelf in way of ventilation damper in galley was found removed and then the operation test for ventilation damper carried out and all considered satisfactory.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 October 2006 Resolved
Main stair tower doors have been bent on the hinge side resulting in door hitting frame before completely closed. Repair as original. SOLAS 60/I/II
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 November 2006
Resolution: Stair case doors on deck levels, 1,2,3,4 and Main deck (port and starboard) were repaired and demonstrated to be in proper working condition to the satisfaction of the ABS Class surveyor.
Engineering › Steering Gear System › Hydraulic Hose
Issued 19 October 2006 Resolved
The STBD steering system oil tank leaks (reported 10 liters/day) vessel crew claims 2m3 spare oil. Repair as original SOLAS 60 II/29.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 November 2006
Resolution: STBD steering system oil tank was sealed by steel plate. Tank was examined to be in proper working condition and accepted by the attending ABS Class surveyor.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.