Inspection history · 106
25 September 2007
Load Line/Change of Employment
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3065824
23 August 2007
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3036432
26 March 2007
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2895140
26 October 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2808517
11 October 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2798501
30 August 2006
Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2764071
2 August 2006
Drydock Extension
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2732806
16 March 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2603729
12 July 2005
MTSA Verification · Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2423620
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2134260
17 August 2004
MTSA Verification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2168354
2 August 2004
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2154345
22 July 2003
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1853711
17 June 2002
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1630892
13 August 2001
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1069174
9 August 2001
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1389503
18 June 2001
Examination of Repairs · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1401534
29 September 2000
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 822091
26 September 2000
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 821368
24 July 2000
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1051719
20 June 2000
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 819471
26 August 1999
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1369292
30 June 1999
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1436233
28 October 1998
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 804213
23 June 1998
COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1406353
2 February 1998
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 785731
10 September 1997
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1375116
8 May 1997
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1098980
25 January 1997
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 694312
22 January 1997
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1098663
11 December 1996
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1091397
11 December 1996
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1363918
25 November 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 202859
19 August 1996
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1087896
1 August 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1390285
26 July 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1435782
1 May 1996
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1083035
8 April 1996
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1078244
25 March 1996
Drydock Extension
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1448749
5 March 1996
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1077447
8 February 1996
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1184607
29 December 1995
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 876532
20 December 1995
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1181097
12 September 1995
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1190858
7 September 1995
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1186124
28 August 1995
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1192153
25 August 1995
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1189532
23 August 1995
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1188552
28 March 1995
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 830778
17 February 1995
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1157810
19 January 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 828781
5 August 1993
Hull Examination · Permit to Proceed · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 840974
7 June 1993
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 829621
2 April 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 357304
29 March 1993
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 647490
16 March 1993
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 471483
13 March 1993
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 106252
23 February 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 675900
22 February 1993
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1145977
20 February 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 99434
20 February 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 228910
20 February 1993
Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1145167
3 February 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 37987
29 December 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 675898
15 December 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 476803
5 September 1992
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 939224
4 September 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 122733
3 August 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 352338
9 June 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 454831
5 May 1992
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 951629
3 January 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 456262
7 October 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 475318
16 May 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1218533
12 April 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 908090
15 February 1991
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 914042
15 February 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 917099
14 December 1990
Permit to Proceed
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1220055
14 November 1990
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 924240
22 May 1990
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1227004
18 May 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 931189
9 May 1990
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1239974
7 April 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1227883
3 April 1990
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 927003
30 August 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 442230
20 July 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 895049
22 June 1989
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 888633
22 March 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899200
17 March 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 480116
29 August 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 449296
26 May 1988
Hull Examination · Examination of Repairs · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 888187
30 March 1988
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 991785
14 December 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 524619
26 June 1987
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1014668
8 June 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 459610
1 May 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1014044
20 April 1987
MARPOL Annex II Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1006629
18 February 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 449455
30 April 1986
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 985599
10 April 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 308108
13 March 1986
Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 996723
1 October 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 988984
29 May 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 977837
26 February 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 466880
8 September 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1271800
13 April 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 972091
13 July 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969772
Electrical › Electric Generation Source (service)
Issued 17 June 2002
Resolved
MAKE PERMANENT REPAIRS TO #2 GENERATOR EMERGENCY SHUTDOWN. LEGACY COMPONENT DESC: Generator
Due 17 July 2002
Resolved 26 June 2002
Resolution: INOPERATIVE SHUTDOWN REPLACED - TESTED SATISFACTORILY.
Electrical
Issued 9 August 2001
Resolved
REPAIR AUTOMATIC VOLTAGE REGULATION
Condition: Unknown
Due 9 September 2001
Resolved 14 November 2001
Electrical
Issued 9 August 2001
Resolved
REPAIR/CALIBRATE CARGO PUMP ENGINE TACHOMETERS
Condition: Unknown
Due 9 August 2001
Resolved 14 November 2001
Electrical
Issued 9 August 2001
Resolved
REPAIR/CALIBRATE ALL GENERATOR METERS, KW, AMPS, CYCLES, VOLTS.
Condition: Unknown
Due 9 September 2001
Resolved 14 November 2001
Construction/Loadline
Issued 18 June 2001
Resolved
PROVIDE COPY OF DRYDOCK GAUGING REPORT
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Lifesaving
Issued 18 June 2001
Resolved
PROPERLY INSTALL LIFERAFT PRIOR TO SAILING MANNED
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Deck/Cargo
Issued 18 June 2001
Resolved
CONDUCT THERMAL HEATER TEST INCLUDING ALL TEST RECOMMENDED IN MANUFACTURES INSTRUCTION MANUAL.
Condition: Unknown
Due 16 August 2001
Resolved 16 August 2001
Deck/Cargo
Issued 18 June 2001
Resolved
PROVE PROPER OPERATION OF CARGO PUMP EMERGENCY SHUTDOWN.
Condition: Unknown
Due 16 August 2001
Resolved 16 August 2001
Lifesaving
Issued 18 June 2001
Resolved
PRIOR TO SAILING MANNED, PERFORM HYDROSTATIC TEST OF SCBA BOTTLES.
Condition: Unknown
Due 27 July 2001
Resolved 27 July 2001
Construction/Loadline
Issued 18 June 2001
Resolved
PROPERLY REPAIR ALL INTERNAL DEFECTS AS IDENTIFIED ON WORK LIST.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Deck/Cargo
Issued 18 June 2001
Resolved
PROVE PROPER OPERATION OF HYDRAULIC PUMP EMERGENCY SHUTDOWN
Condition: Unknown
Due 16 August 2001
Resolved 16 August 2001
Electrical
Issued 18 June 2001
Resolved
PROVE PROPER OPERATION OF BOTH SSDG'S.
Condition: Unknown
Due 16 August 2001
Resolved 16 August 2001
Deck/Cargo
Issued 18 June 2001
Resolved
PRIOR TO OPERATING THERMAL HEATER CONDUCT HYDROSTATIC TEST OF FLUID PIPING.
Condition: Unknown
Due 16 August 2001
Resolved 16 August 2001
Deck/Cargo
Issued 20 June 2000
Resolved
RENEW THERMAL FLUID HEATER REAR PEEP SIGHT
Condition: Unknown
Due 20 July 2000
Resolved 28 June 2000
Electrical
Issued 20 June 2000
Resolved
ADJUST NUMBER 1 GENERATOR OVERSPEED TO ACTIVATE BETWEEN 10% AND 15% OF RATED RPM. 1980-2070 RPM.
Condition: Unknown
Due 20 July 2000
Resolved 28 June 2000
Electrical
Issued 20 June 2000
Resolved
RENEW GROUND INDICATING PANEL
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Accommodation/Occupational Safety
Issued 20 June 2000
Resolved
REPAIR AIR RECEIVER DRAIN
Condition: Unknown
Due 20 July 2000
Resolved 28 June 2000
Lifesaving
Issued 20 June 2000
Resolved
RENEW ALL FOUR WATERLIGHT BATTERIES. NEW BATTERIES TO HAVE SCREW ON TERMINALS.
Condition: Unknown
Due 27 June 2000
Resolved 28 June 2000
Deck/Cargo
Issued 20 June 2000
Resolved
RENEW CARGO OIL PUMP BULKHEAD SEAL
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Construction/Loadline
Issued 26 August 1999
Resolved
CLEAN HULL EXTERIOR AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 26 August 1999
Resolved 26 August 1999
Fire Fighting
Issued 23 June 1998
Resolved
Repair CO2 bottle's pull handle on portable fire extinguisher in Thermal Fuid Heater room.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Construction/Loadline
Issued 23 June 1998
Resolved
Repair watertight gasket to cargo pump room.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Navigation
Issued 1 August 1996
Resolved
RECHARGE PORT RUNNING LIGHT BATTERY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Lifesaving
Issued 1 August 1996
Resolved
PROVE PROPER OPERATION OF ANCHOR WINDLASS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Engineering
Issued 1 August 1996
Resolved
PROVIDE AND INSTALL FLAME IMPINGEMENT BOWLS ON RACOR FUEL FILTERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Engineering
Issued 1 August 1996
Resolved
MAKE THERMAL FLUID HEATER OPERATIONAL, AND MAKE AVAILABLE FOR TESTING AS PER USCG APPROVED PROCEDURES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Lifesaving
Issued 1 August 1996
Resolved
PROPERLY SECURE HYDRAULIC LINES TO FORWARD CAPSTAIN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Lifesaving
Issued 1 August 1996
Resolved
PROPERLY MOUNT 15 MAN LIFERAFT HYDROSTATIC RELEASE MECHANISM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Deck/Cargo
Issued 1 August 1996
Resolved
PROVIDE AND INSTALL HIGH SUCTION VALVE, REMOTE VALVE INDICATOR, AND REMOTE OPERATOR FOR C.O.T. #2 PORT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Deck/Cargo
Issued 1 August 1996
Resolved
PROVE PROPER OPERATION OF BOTH ONDECK CRANES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Lifesaving
Issued 1 August 1996
Resolved
REPLACE LIGHTBULBS IN GENERATOR AND CARGO PUMP ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Electrical
Issued 1 August 1996
Resolved
PROVE PROPER OPERATION OF GROUND FAULT INDICATOR IN GENERATOR ROOM CURRENTLY SHOWING DEAD SHORT TO GROUND ON ONE PHASE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Engineering
Issued 1 August 1996
Resolved
LABEL BOTH FUEL OIL TANK SHUT OFF VALVES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Accommodation/Occupational Safety
Issued 1 August 1996
Resolved
COMPLETE REPAIRS TO EXHAUST VENTILATION SYSTEM IN THERMAL FLUID HEATER ROOM_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Lifesaving
Issued 1 August 1996
Resolved
PROVIDE EVIDENCE OF PROPER BENZENE EXPOSURE MONITORING PROGRAM AS PER 46 CFR 197.501._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO MULTIPLE FRACTURES TO MID TANK BAFFLE AT INBOARD, AND SIDE SHELL CONNECTIONS OF COT #2 STBD WHERE MARKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO FRACTURE IN FWD BULKHEAD INBOARD SIDE OF COT #2 PORT WHERE MARKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO HOLED AREA IN BOTTOM PLATE IN CARGO TANK #2 PORT, AND IN FRACTURED BOTTOM PLATE AND ASSOCIATED INTERNALS IN AFTER RAKE, AS OUTLINED AND DISCUSSED WITH MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Deck/Cargo
Issued 26 July 1996
Resolved
PROVE PROPER OPERATION OF ALL CARGO SYSTEM VALVING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Deck/Cargo
Issued 26 July 1996
Resolved
PROVIDE AND INSTALL REMOTE VALVE INDICATORS ON ALL CARGO VALVES, WHICH ARE NOT PRESENTLY FITTED WITH REMOTE INDICATORS, AS PER 46 CFR 56.20.9 (a)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Deck/Cargo
Issued 26 July 1996
Resolved
REMOVE AND PROPERLY BLANK OFF ALL CARGO OIL PIPING LEADING TO AND FROM THEAFTER RAKE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Construction/Loadline
Issued 26 July 1996
Resolved
CLEAN INTERNALS OF AFT RAKE IN WAY OF FRACTURED LONGITUDINAL FRAME, AND ASSOCIATED DOUBLE ON OUTSIDE SHELL PLATE FOR FURTHER INSPECTION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Construction/Loadline
Issued 26 July 1996
Resolved
PROVIDE COPY OF APPROVED PLANS SHOWING DETAILS OF C.O.T.'S #1 CENTER AND #2CENTER TANK TOPS DOUBLER PLATES.
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Electrical
Issued 26 July 1996
Resolved
REMOVE OR PROPERLY DEADEND ALL ELECTRICAL WIRING IN FORWARD RAKES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
SUBMIT PROPOSAL TO MAKE PERMANENT REPAIR TO ALL DOUBLED, WASTED, HOLED AREAS ON THE COT #3 TANK TOPS BENEATH THE TWO AFTER HOUSES. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
OPEN FUEL TANK (CURRENTLY NOT IN USE) IN AFTER RAKE FOR FURTHER_x001C_ INSPECTION. (MAKE UNUSABLE BY REMOVE MAN HOLE BOLTS AND CUT ACCESS OPENINGIN TOP AND BOTTOM FOR VENTILATION/INSPECTION._x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Deck/Cargo
Issued 26 July 1996
Resolved
PROVIDE COPY OF SATISFACTORY HYDROSTATIC TEST RESULTS FOR CARGO OIL PIPING AND CARGO PUMP REVIEF VALVE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIRS TO FRACTURES LOCATED IN FRAMES 1,2,3,7 OF CARGO OIL TANK #3 PORT AND STBD SIDE SHELL FRAMES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Deck/Cargo
Issued 26 July 1996
Resolved
PROVIDE AND INSTALL C.O.T. HIGH LEVEL ALARM SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO SID ESHELL LONG IN WAY OF #2 FROM AFT WEB FRAME INCOT #1 PORT (WHERE MARKED) INSERT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO MULTIPLE FRACTURES LOCATED IN SIDE SHELL LONGS_x001C_ AND SIDE WEB FRAME, AT #3 FROM AFT WEB FRAME IN COT #1 PORT (WHERE MARKED)_x001C__x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO FRACTURE IN SIDE LONG (1ST FROM TURN OF BILGE) IN WAY OF 1ST WEB FRAME FROM AFT BLKD IN COT #1 STBD (WHERE MARKED)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO FRACTURES IN SIDE SHELL LONGS BETWEEN SIDE WEB FRAMES #1, AND #2 FROM AFT BLKD IN COT #1 STBD (WHERE MARKED)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO FRACTURES IN SIDE SHELL LONGS BETWEEN SIDE WEB FRAMES 3 + 4, AND 4 + 5, FROM AFT BLKD IN COT #1 STBD WHERE MARKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO FRACTURES IN AFT BULKHEAD (2 EACH) AT CONNECTION TO SIDE LONG IN COT #2 STBD WHERE MARKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO MULTIPLE FRACTURES AT INBOARD BLKD VERTICLE STIFFENERS IN COT #2 STBD WHERE MARKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
PROVIDE/PERFORM GAUGINGS OF HULL PLATE IN PRESENCE OF MARINE INSPECTOR, ENSUR COPY OF ORIGINAL HULL PLATE SCANTLINGS IS MADE AVAILABEL AND PROVIDE COPY OF OFFICIAL GAUGING REPORT._x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Deck/Cargo
Issued 26 July 1996
Resolved
REPLACE TOP OF #1 PORT AND STBD C.O.T. TRUNK WHERE WASTED AND HOLED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO MULTIPLE FRACTURES AT INBOARD BULKHEAD VERTICLE STIFFENERS OF COT #2 PORT WHERE MARKED_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO AFT BULKHEAD WHERE FRACTURED (HIGH) OF COT #2 PORTWHERE MARKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO FWD BULKHEAD PORT LOWER CORNER FRACTURE IN COT #3 STBD WHERE MARKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO FIVE SIDE SHELL LONGS WHERE FRACTURED AND MARKED IN COT #3 STBD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO THIRD FROM AFT SIDE WEB FRAME AT TURN OF BILGE WHERE FRACTURED IN COT #3 STBD WHERE MARKED. (INSERT)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
REMOVE AND REPLACE ONE DIAGONAL STIFFENER WHERE BENT AND FRACTURED AT CENTERLIN BLKD INCOT #3 STBD WHERE MARKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO FRACTURE IN FWD BULKHEAD (UP HIGH BEHIND CRANE PEDESTAL) IN COT#2 STBD WHERE MARKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
MAKE PERMANENT REPAIR TO FRACTURE LOCATED IN AFTER INBOARD LOWER CORNER/SHELF OF COT #1 PORT (WHERE MARKED)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1996
Resolved 11 September 1996
Construction/Loadline
Issued 26 July 1996
Resolved
REMOVE TWO DOUBLERS ON UNDERWATER BODY SHELL PLATE AND MAKE AVAILABLE FOR FURTHER INSPECTION. ONE LOCATED ON AFT RAKE AND THE OTHER ON THE BOTTOM PLATE IN WAY OF COT #2 PORT AT CENTERLINE_x001C_ _x001C_
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Electrical
Issued 8 April 1996
Resolved
RENEW/ADJUST BOTH 6-71 GENERATOR TACHOMETERS, CURRENTLY NOT READING PROPER RPM.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Electrical
Issued 5 March 1996
Resolved
PROVIDE PLANS TO EITHER ABS OR OCMI FOR APPROVAL OF RECENT NAV LIGHT INSTALLATION ON COMM CENTER HOUSE.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Engineering
Issued 5 March 1996
Resolved
PROVIDE A MARINE FUEL FILTER FOR CARGO AND HYDRAULIC ENGINE
Condition: Unknown
Due 6 April 1996
Resolved 8 April 1996
Electrical
Issued 5 March 1996
Resolved
PROVIDE AND TEST GENERATOR OVERSPEEDS, CURRENTLY REMOVED FOR REPAIRS
Condition: Unknown
Due 6 April 1996
Resolved 8 April 1996
Deck/Cargo
Issued 5 March 1996
Resolved
PROVIDE DOCUMENTATION ATTESTING TO ANNUAL HYDROSTATIC TEST OF CARGO PIPING
Condition: Unknown
Due 6 April 1996
Resolved 8 April 1996
Deck/Cargo
Issued 5 March 1996
Resolved
REPLACE RETAINING CLIPS ON P.V. FLAME SCREENS 1S,2C,3P AND 3S
Condition: Unknown
Due 6 April 1996
Resolved 8 April 1996
Deck/Cargo
Issued 5 March 1996
Resolved
REPLACE HOLED FLAME SCREEN ON 2S PV
Condition: Unknown
Due 6 April 1996
Resolved 8 April 1996
Deck/Cargo
Issued 5 March 1996
Resolved
REPLACE MISSING FLANGE BOLT ON 2S P.V.
Condition: Unknown
Due 6 April 1996
Resolved 8 April 1996
Engineering
Issued 5 March 1996
Resolved
SECURE LOOSE FUEL PIPE AT THERMAL FLUID HEATER.
Condition: Unknown
Due 6 April 1996
Resolved 8 April 1996
Fire Fighting
Issued 7 September 1995
Resolved
PROVIDE AN APPROVED FIXED CO2 SYSTEM FOR THE THERMAL HEATER ROOM AS REQUIRED BY 46 CFR 34.05(A)(5). THE THERMAL HEATER SHALL NOT BE USED UNTILINSTALLED.
Condition: Unknown
Due 7 September 1995
Resolved 7 September 1995
Construction/Loadline
Issued 28 August 1995
Resolved
Complete repairs to starboard machinery house support structure as outlinedin repair proposal submitted to comply with def 017 issued on 19 January 95. All repairs shall be made to the satisfaction of the attendingmarine inspector.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Unknown
Issued 19 January 1995
Resolved
PROVIDE A 2 DAY SUPPLY OF RESPIRATOR CARTIDGES FOR ALL CREWMAN AND WORKERS
Condition: Unknown
Due 19 February 1995
Resolved 21 February 1995
Lifesaving
Issued 19 January 1995
Resolved
PROVIDE SUITABLE FLAM. STORES LOCKER FOR FLAMMABLE (PAINTS, CLEANERS, ETC.)CURRENTLY BEING STORED IN WORKSHOP, OR REMOVE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Fire Fighting
Issued 19 January 1995
Resolved
SECURE BV FIRE EXTINGUISHER, FITTED ON STAND UP DOLLY.
Condition: Unknown
Due 19 February 1995
Resolved 21 February 1995
Electrical
Issued 19 January 1995
Resolved
PROVIDE DI-ELECTRIC MAT IN FRONT OF GENERATOR SWITCHBOARD CONTROLS
Condition: Unknown
Due 19 February 1995
Resolved 21 February 1995
Unknown
Issued 19 January 1995
Resolved
SECURED WEATHER DECK WALKWAY GRATES.
Condition: Unknown
Due 19 February 1995
Resolved 21 February 1995
Electrical
Issued 19 January 1995
Resolved
PROVIDE EMERGENCY LIGHTING TO ILLUMINATE LIFERAFT OPERATIONS AS REQUIRED BY46 CFR 33.20-1(C)(3) AND 112.43
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Lifesaving
Issued 19 January 1995
Resolved
PROVIDE DETAILS REGARDING THE SUITABILITY OF THE STANDBY VESSEL, IT'S ACCOMMODATIONS, GALLEY, AND BERTHING AREA, AND PERSONNEL TRANSFER AT SEA DETAILS
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Unknown
Issued 19 January 1995
Resolved
PROVE OPERATION OF GENERATOR ROOM VENTILATION SHUT DOWN DEVICE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 February 1995
Resolved 21 February 1995
Engineering
Issued 19 January 1995
Resolved
CLEAN/REPLACE BOTH FUEL TANK VENT SCREENS.
Condition: Unknown
Due 19 March 1995
Resolved 21 February 1995
Navigation
Issued 19 January 1995
Resolved
PROVIDE DOCUMENTATION ATTESTING THAT DAY LIGHT CONTROLLS ON NAVIGATION LIGHTS COMPLY WITH COL REGS, VESSEL RESTRICTED FROM OPERATION IN REDUCED VISIBILITY._x001C_ _x001C_
Condition: Unknown
Due 19 February 1995
Resolved 21 February 1995
Construction/Loadline
Issued 19 January 1995
Resolved
PROVIDE DETAILED REPAIR PLAN ADDRESSING CORROSION OF STRUCTURAL MEMBERS UNDER STARBOARD MACHINERY HOUSE.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Construction/Loadline
Issued 19 January 1995
Resolved
MAKE REPAIRS TO THE FOLLOWING AREAS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR: A. WELD REPAIR P.RAKE 1ST FRAME AT INTERSECTION WITH LONGS 1,2,5; 3RD FRAME AND LONG 1; 2ND FRAME AND LONG 5. IN STBD. RAKE FRAME 3 AT INTERSECTION WITH CENTERLINE BHD WHERE TORN AND BUCKLED.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Deck/Cargo
Issued 19 January 1995
Resolved
REPAIR CORRODED KNIFE EDGE OF THE 6 INCH 3P AND 3S ULLAGE OPENINGS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1995
Resolved 2 May 1995
Construction/Loadline
Issued 19 January 1995
Resolved
REPLACE GASKETTING IN WATERTIGHT DOOR ON GENERATOR ROOM.
Condition: Unknown
Due 19 February 1995
Resolved 2 May 1995
Construction/Loadline
Issued 19 January 1995
Resolved
MAKE BOTH WATERTIGHT DOORS FOR ENGINEROOM AND THE WATERTIGHT DOOR FOR THE WORKSHOP WATERTIGHT, ALL CURRENTLY BOWED, TOTAL OF 3 DOORS.
Condition: Unknown
Due 19 March 1995
Resolved 2 May 1995
Fire Fighting
Issued 19 January 1995
Resolved
HYDRO TEST 15 POUND CO2 EXTINGUISHERS LOCATED IN GENERATOR ROOM, ENGINEROOM, AND THERMAL HEATER ROOM. _x001C_
Condition: Unknown
Due 19 March 1995
Resolved 2 May 1995
Lifesaving
Issued 19 January 1995
Resolved
PROVIDE SAFETY RAILS AROUND BOW AREA AS PER 46 CFR 32.02-10(C)
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Construction/Loadline
Issued 19 January 1995
Resolved
PROVIDE BILGE SYSTEM TO COMPLY WITH 46 CFR 32.52-1 AND 56.50-50
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Lifesaving
Issued 19 January 1995
Resolved
PROVIDE EMERGENCY OUTFIT FOR CARGO TANK ENTRY AS REQUIRED BY _x001C_ 46 CFR 35.30-20
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Navigation
Issued 19 January 1995
Resolved
PROVIDE NAVIGATION LIGHTS AND SYSTEM MEETING 46 CFR 111.75-17
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Navigation
Issued 19 January 1995
Resolved
REPAIR CORRODED BATTERY BOX FOUNDATIONS ON PORT AND STARBOARD NAVIGATION LIGHTS.
Condition: Unknown
Due 19 February 1995
Resolved 2 May 1995
Fire Fighting
Issued 19 January 1995
Resolved
PROVIDE AN APPROVED FIXED CO2 SYSTEM FOR THE THERMAL HEATER ROOM AS REQUIRED BY 46 CFR 34.05-5(A)(5). THE THERMAL HEATER SHALL NOT BE OPERATEDUNTIL INSTALLED
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Deck/Cargo
Issued 19 January 1995
Resolved
PROVIDE PROPERLY FITTING FLAME SCREEN ON 2S ULLAGE OPENING, CURRENT SCREEN IS OF IMPROPER SIZE.
Condition: Unknown
Due 19 April 1995
Resolved 2 May 1995
Electrical
Issued 19 January 1995
Resolved
PROVIDE DRIP TRAY OVERBATTERY CHARGER IN GENERATOR ROOM.
Condition: Unknown
Due 19 February 1995
Resolved 21 February 1995
Construction/Loadline
Issued 19 January 1995
Resolved
REPAIR/REPLACE WATERTIGHT DOOR (AFT) FOR THERMAL HEATER ROOM, CORRODED AT BOTTOM.
Condition: Unknown
Due 19 March 1995
Resolved 2 May 1995
Deck/Cargo
Issued 20 February 1993
Resolved
VESSEL AUTHORIZED TO PROCEED EMPTY TO BLUDWORTH'S, CORPUS CHRISTI SHIP CHANNEL. UPON ARRIVAL, CERTIFY NO. 3 STARBOARD CARGO TANK GAS FREE AND CONDUCT APPORPRIATE PRESSURE TEST OF CARGO LINE IN THAT TANK TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR._x001C_
Condition: Unknown
Due 20 February 1993
Resolved 20 February 1993
Engineering
Issued 5 May 1992
Resolved
Properly install exhaust lagging for both ss generators.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Engineering
Issued 5 May 1992
Resolved
Test steps 1, 2, 4 of fluid thermal heaters; starboard heater 1 & 2.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Electrical
Issued 5 May 1992
Resolved
Label all electrical power panels with voltage adn load supplied.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Engineering
Issued 5 May 1992
Resolved
Provide exhaust lagging for port cargo pump.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Construction/Loadline
Issued 5 May 1992
Resolved
Free dogs on all watertight doors.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Engineering
Issued 5 May 1992
Resolved
Clean or replace fuel oil vent screens for D. O. tanks.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Unknown
Issued 5 May 1992
Resolved
Repair vent duct outlet in aft stbd fluid termal heater space overhead outboard side.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Construction/Loadline
Issued 3 April 1990
Resolved
PROCEED TO NEXT PORT OF CALL(TAMPA,FL.), DISCHARGE CARGO AND CONDUCT INTERNAL STRUCTURAL EXAMINATION OF ALL VOIDS(BOW&STERN) AND CARGO TANKS TO COMPLETE DAMAGE SURVEY TO THE SATISFACTION OF THE [name withheld].
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Deck/Cargo
Issued 22 June 1989
Resolved
CLEAN OR RENEW FLAME SCREENS FOR NO. 3 PORT AND STARBOARD CARGO TANKS.
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Deck/Cargo
Issued 22 June 1989
Resolved
HYDROSTATICALLY TEST CARGO DECK PIPING.
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Documentation
Issued 22 June 1989
Resolved
PROVIDE FOR ANNUAL ENDORSEMENT OF LOADLINE CERTIFICATE.
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Deck/Cargo
Issued 22 June 1989
Resolved
STENCIL EMERGENCY SHUT DOWN FOR CARGO PUMP ENGINES.
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Engineering
Issued 26 May 1988
Resolved
SUBMIT FOR APPROVAL, THE TEST PROCEDURES FOR THE PORT AND STARBOARD THERMALFLUID HEATERS TO [name withheld], TX.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Documentation
Issued 26 May 1988
Resolved
PLACE ONBOARD A COPY OF THE STABILITY LETTER ISSUED 15JUN78.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Engineering
Issued 26 May 1988
Resolved
INSTALL HEAT DEFLECTOR BOWLS ON ALL RACOR FUEL OIL FILTERS.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Electrical
Issued 8 September 1983
Resolved
REPAIR STARBOARD GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 8 September 1983
Resolved 8 September 1983
Electrical
Issued 8 September 1983
Resolved
REPAIR LAGGING ON STARBOARD GENERATOR EXHAUST.
Condition: Unknown
Due 8 September 1983
Resolved 8 September 1983