Records from 2010 to 2026. Most recent: inspection, 11 May 2026.
Inspection history · 32
11 May 2026
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8370936
16 March 2026
COI Inspection · Deficiency Check · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8327293
15 April 2025
MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8198651
25 February 2025
Administrative Inspection · DAPI Audit · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8198457
27 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7905491
8 January 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7863465
20 December 2023
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7841071
15 May 2023
COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7681233
8 December 2022
Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7606698
30 November 2022
Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7601979
24 May 2022
COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7449895
19 November 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7370908
26 May 2021
COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7201359
24 November 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7101860
23 September 2020
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7063836
10 September 2020
Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7054909
27 May 2020
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6961903
27 August 2019
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6804202
31 July 2019
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6768357
31 May 2019
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6686267
13 March 2019
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6641880
6 March 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6636532
23 August 2018
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6520363
9 February 2018
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6358980
4 January 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6331064
22 August 2017
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6242522
17 April 2017
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6161168
6 January 2017
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6064581
22 September 2016
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6010474
22 August 2016
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5979898
17 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5910145
22 February 2016
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5819885
14 - Pollution Prevention › 143 - MARPOL Annex III › Other (MARPOL Annex III)
Issued 11 May 2026
No resolution recorded
Key personnel must complete training in 33CFR101.650(d)(2) by January 12, 2026.
Company does not have a CYSO and all key personnel have not yet completed the training as of this inspection.
33 CFR 101.650(d)(4)
705: 60 days
Action required: 705 - Other - as specified
Due 11 May 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to:(a) Provide services necessary for safety under normal and emergency conditions;(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock;(c) Minimize accidental personnel contact with energized parts; and(d) Prevent electrical ignition of flammable vapors.
MI observed multiple locations within the lazarette with exposed wiring, exposed junction boxes, and inoperable battle lanterns (emergency lighting).
Make corrections and maintenance all electrical installations withing the lazarette and make as originally designed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 19 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2026
Resolved
All machinery and equipment must be installed and maintained.
Hydraulic steering pump operated as designed, however, the pump casing and wiring was heavily corroded. Due to apparent lack of maintenance and overall poor material condition of hydraulic pump, replace the pump in kind with new.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2026
Resolved 30 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2026
Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks.
Owner self-reported main engine exhaust leak. Temp repairs were made due to unavailability of parts. No active exhaust leaks were present. Subbase is in process of fabricating a custom section of the exhaust piping. Estimated time of completion is 60 days.
Remove lagging in all suspect areas of exhaust piping in engine room and lazarette and inspect for leaks. Make all necessary repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2026
Resolved 17 June 2026
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 24 May 2022
Resolved
Provide a working radar screen and prove proper operation of the vessel's radar.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 8 December 2022
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 24 May 2022
Resolved
Provide visual indicator for engine compartment bilge high water level alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 8 December 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 May 2022
Resolved
Post COI and Stability Letter where observation by passengers is likely.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 8 December 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 May 2022
Resolved
Provide current FCC Vessel Certificates.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 8 December 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 November 2020
Resolved
Electrical equipment used in a machinery space must be drip proof. Steering control junction box in the steering gear space is wasted and holed. Replace junction box in-kind.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 19 November 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 November 2020
Resolved
Cable support rigging for the tower above the pilot house is not properly tensioned.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 25 November 2020
Resolution: Verified rigging tensioning.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 November 2020
Resolved
Observed 4 inch crack in weld seam of port rudder (inboard side) at the bottom of the rudder post and 5 other corrosion points along the vertical weld seams of the same area. Make proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2020
Resolved 25 November 2020
Resolution: Verified repairs. All cracks were grinded out and clad welded.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 September 2020
Resolved
Vessel's scheduled drydock inspection on was not able to be completed on schedule due to the COVID-19 Pandemic. Vessel movement is restricted to domestic voyages only, per MSIB 09-20. A drydock inspection must be completed prior to carrying passengers on an international voyage. After 27AUG21, and in accordance with 46CFR176.600(c)(1), SUNDANCE BREEZE is prohibited from carrying passengers on any route until a drydock examination is completed.
Action required: 702 - Prior to embarking on international voyage
Resolved 19 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 May 2020
Resolved
The three inflatable buoyant apparatus on board require servicing. All three were last serviced April of 2019, but although brand new, they require annual servicing for the vessel's SOLAS route per 46 CFR 160.151-57(n)(1)(ii) and cannot go 2 years between service. Vessel has an EPIRB and is restricted to a domestic route <3 miles from land until the IBAs are serviced and properly mounted back on the vessel.
Action required: 705 - Other - as specified
Resolved 24 May 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 March 2019
Resolved
Replace time delay for CO2 system and provide service report.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 25 April 2019
Resolution: New time delay installed and inspected.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 March 2019
Resolved
Provide current EPIRB hydrostatic release.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 25 April 2019
Resolution: New hydrostatic release installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2019
Resolved
Provide proof of random drug testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 13 March 2019
Resolution: Witnessed proof of random drug testing of crew.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 6 March 2019
Resolved
Amend SMS daily check sheet to log monthly EPIRB testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 25 April 2019
Resolution: Provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 March 2019
Resolved
Remove or properly protect bus bars on generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 25 April 2019
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 March 2019
Resolved
Make proper connections on relay on generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 25 April 2019
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 March 2019
Resolved
Degrease breaker panel on center distribution panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 25 April 2019
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 March 2019
Resolved
Replace holed raw water hose outboard starboard main diesel engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 25 April 2019
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 March 2019
Resolved
Make proper connection of wires on center main diesel engine PTO clutch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 25 April 2019
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 6 March 2019
Resolved
Provide watertight seal on aft hatch, main deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 25 April 2019
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2019
Resolved
Repair grinding tiller connection bolt on port rudder post tiller.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 25 April 2019
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 6 March 2019
Resolved
Properly fasten deck hatch forward of bar in main cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 25 April 2019
Resolution: Corrected.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 January 2018
Resolved
Obtain corrected Safety Radiotelephony Certificate with correct MMSI and Call Sign.
Action required: 705 - Other - as specified
Due 4 February 2018
Resolved 9 February 2018
Resolution: Vessel provided updated SRC
Communications › Radio Communications › VHF Radiotelephone
Issued 4 January 2018
Resolved
Demonstrate that correct MMSI is entered into DSC VHF radios and AIS.
Action required: 705 - Other - as specified
Due 4 February 2018
Resolved 9 February 2018
Resolution: Vessel demonstrated that correct info was programmed into VHF and AIS.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 January 2018
Resolved
Demonstrate properly operating emergency lighting in passenger cabin.
Action required: 705 - Other - as specified
Due 4 February 2018
Resolved 9 February 2018
Resolution: Vessel replaced globe.
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 January 2018
Resolved
Mount engine room bilge high level alarm float switch.
Action required: 705 - Other - as specified
Due 4 February 2018
Resolved 9 February 2018
Resolution: Vessel mounted bilge alarm.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 January 2018
Resolved
Provide globe for engine room light.
Action required: 705 - Other - as specified
Due 4 February 2018
Resolved 9 February 2018
Resolution: Vessel replaced globe.
Construction/Loadline › Structures › Deck Plating
Issued 22 August 2017
Resolved
WORK LIST: Deck plating wasted IVO water fill piping on port side. Provide repair proposal and repair.
Action required: 705 - Other - as specified
Resolved 25 August 2017
Resolution: Area cropped and renewed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 January 2017
Resolved
Conduct drills in accordnace with vessel's SMS.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 17 February 2017
Resolution: Vessel provided updated drill log.
Communications › Radio Communications › EPIRB
Issued 6 January 2017
Resolved
Conduct and log EPIRB tests monthly.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 17 February 2017
Resolution: Vessel completed EPIRB tests.
Electrical › Electric Generation Source (service) › Generator
Issued 6 January 2017
Resolved
Clean, diagnose and repair oil leak on service generator.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 17 February 2017
Resolution: Vessel corrected leaks and cleaned generator.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 6 January 2017
Resolved
Ensure complete wrapping on port engine exhaust lagging.
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 23 January 2017
Resolution: Vessel re-wrapped engine exhaust.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 January 2017
Resolved
Provide protective globe for light fixture on starboard side of engine room.
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 23 January 2017
Resolution: Globe and cage provided.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 6 January 2017
Resolved
Replace missing blanks on switchboard breaker panel.
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 23 January 2017
Resolution: Plexiglass covering provided.
Lifesaving › Lifebuoys › Serviceable
Issued 6 January 2017
Resolved
Replace retro-reflective tape on both aft ring buoys.
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 17 February 2017
Resolution: Vessel replaced retro tape.
Communications › Audible Communications › Bell
Issued 6 January 2017
Resolved
Provide 300mm diameter bell.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 17 February 2017
Resolution: Vessel replaced bell.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 January 2017
Resolved
Label PFD storage locations on upper deck.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 17 February 2017
Resolution: PFD storage locations labeled and marked.
Engineering › Sea-water System (primary cooling) › Valve
Issued 23 August 2016
Resolved
Generator and fire pump sea-valves unservicable. Repair or replace sea-valves and make servicable.
Action required: 705 - Other - as specified
Resolved 30 August 2016
Resolution: New sea valves installed.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 23 August 2016
Resolved
Cracked welds found at fuel tank attachment points. Crop and renew cracked welds.
Action required: 705 - Other - as specified
Resolved 30 August 2016
Resolution: All cracked welds cropped and renewed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 February 2016
Resolved
Operator failed to make vessel available for an annual inspection within 3 months of the anniversary date of 08Oct2015. Complete renewal inspection prior to carrying passengers.
Action required: 705 - Other - as specified
Due 23 February 2016
Resolved 23 February 2016
Fire Fighting › Nozzles › Condition
Issued 23 February 2016
Resolved
Replace fire hose nozzle due to stripped threads.
Action required: 705 - Other - as specified
Resolved 23 February 2016
Resolution: Corrected on the spot.
Fire Fighting › Fire Pumps › Pressure
Issued 23 February 2016
Resolved
Replace non-operational fire pump gauge and prove 60psi.
Action required: 705 - Other - as specified
Resolved 23 February 2016
Resolution: Corrected on the spot.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 February 2016
Resolved
Provide proof of compliance with chemical testing requirements. Documentation was not available onboard the vessel at time of inspection.
Action required: 705 - Other - as specified
Resolved 24 February 2016