MAURY USCG vessel records Sign in
← All vessels

STAR KAPPA

STAR KAPPA is a 2001 freight ship. The Coast Guard has recorded 12 inspections since 2002, most recently in March 2017, along with 6 deficiencies and 3 operational controls.

Records from 2002 to 2017. Most recent: inspection, 11 March 2017.

Built
2001
Last inspected
11 March 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9221126 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
511162
Flag
MARSHALL ISLANDS
—
Maury page id
psix-511162

Inspections, by type

…with no type recorded5
Years with a record 7 calendar years (2002–2017)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it50678 - Dead Weight, Ton
69154 - Displacement, Ton
29499 - Convention (Subpart B), Gross Ton
17889 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

11 March 2017 Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6102920
9 March 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6102121
9 March 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6102135
12 May 2014 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4856262
5 May 2014 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4851215
5 May 2014 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4851348
17 September 2010 ISPS III Exam · Ballast Water Examination · PII Safety Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3851597
10 December 2009 ISPS I Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3645934
10 December 2009 Type not recorded
No type recorded · USCGC LONG ISLAND (WPB 1342) · USCG Arctic District (CGD-A) · Activity 3650163
12 November 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3361792
12 February 2006 PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2583825
28 January 2002 Security Inspection · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1481923

Deficiency record · 6

Fire Fighting › Emergency Fire Pumps › Pressure
Issued 11 March 2017 Resolved
0740 - THE EMERGENCY FIRE PUMP PRIMER RUPTURED, RESULTED IN PUMP NOT BEING ABLE TO SUPPLY WATER TO THE FIRE MAIN. 74SOLAS(2001)II-2/4.3.3.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2017
Resolved 13 March 2017
Resolution: Received class report and attended vessel to witness satisfactory operation of the emergency fire pump.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 March 2017 Resolved
0660 - BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING VOYAGE, ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. 24 OF THE 35 LIFEJACKETS WERE IN COMPLETE DISREPAIR AND WOULD NOT MAINTAIN FLOTATION IN THE EVENT OF AN EMERGENCY. THERE ARE CURRENTLY 22 CREW MEMBERS ABOARD WITH ONLY 11 SERVICEABLE LIFE JACKETS. 74SOLAS(2014)III/20.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2017
Resolved 13 March 2017
Resolution: Received class report and attended vessel to confirm presence of new life jackets.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 March 2017 Resolved
2550 - The company should establish procedures, plans & instructions for key shipboard operations concerning the safety of the personnel, ship & protection of the environment. The various tasks should be defined and assigned to qualified personnel. In reference to deficiency 2, ISM implementation of critical lifesaving equipment maintenance is in question. 74SOLAS(2014) IX/3.1 ISM CODE 7 17ac
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 March 2017
Resolved 13 March 2017
Resolution: Received ISM audit report. See attached documents.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 11 March 2017 Resolved
0799 - STAIRWAYS AND LIFT TRUNKS WHICH PENETRATE MORE THAN A SINGLE DECK SHALL BE SURROUNDED BY AT LEAST "A-0" CLASS DIVISIONS AND BE PROTECTED BY SELF-CLOSING DOORS AT ALL LEVELS. THE FOLLOWING A-CLASS FIRE DOORS WOULD NOT LATCH PROPERLY: A-DECK MAIN STAIRWAY, B-DECK MAIN STAIRWAY, AND THE EMERGENCY ESCAPE DOOR BEHIND THE MAIN SWITCH BOARD IN THE ENGINE CONTROL ROOM. 74SOLAS(2001)II-2/46.1 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2017
Resolved 11 March 2017
Resolution: Doors were repaired by the crew.
Documentation › Certificates/Documents › IOPP Certificate
Issued 17 September 2010 Resolved
Vessel required to have a valid international oil pollution prevention certificate, including a supplemental Form A. The maximum throughput for the oily water separator is not included on the supplemental Form A.
Action required: 705 - Other - as specified
Due 21 October 2010
Resolved 22 September 2010
Resolution: Received copy of IOPP with correct maximum throughput for OWS.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 29 November 2006 Resolved
33U.S.C.1321(j)(5)(D)(i)-The NTVRP does not identify the volume and type of fuel oil that would be involved in a worst case discharge 33U.S.C.1321(j)(5)(D)(iii)-The NTVRP does not identify a classified oil spill removal organization (OSRO) or provide an OSRO contract for the remote Guam COTP zone.
Due 29 December 2006
Resolved 15 January 2009
Resolution: NTVRP plan #04831 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.

Ownership record