MAURY USCG vessel records Sign in
← All vessels

STRETCH DUCK 20

STRETCH DUCK 20 is a 1945 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2002, most recently in December 2017, along with 11 deficiencies and 2 operational controls.

Records from 2002 to 2017. Most recent: inspection, 14 December 2017.

Built
1945
Last inspected
14 December 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

511167
Flag
UNITED STATES
—
Maury page id
psix-511167

Inspections, by type

…with no type recorded1
Years with a record 13 calendar years (2002–2017)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

14 December 2017 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6326092
26 June 2017 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6188839
30 January 2017 COI Inspection · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6079909
2 March 2016 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5825318
23 February 2016 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5820309
19 January 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5799833
7 August 2015 Administrative Inspection · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5209576
6 August 2015 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5208619
19 March 2014 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4799878
21 September 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4162291
8 December 2010 Deficiency Check · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3897162
9 December 2009 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3653019
22 October 2008 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3346141
22 February 2007 Deficiency Check · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2891619
17 November 2005 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2536693
25 October 2005 Examination of Repairs · Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2498214
1 March 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2301518
12 October 2004 Deficiency Check · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2216945
16 December 2003 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1965190
17 September 2003 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1876347
25 February 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1739528
26 August 2002 Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1666445
8 May 2002 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1611892
28 January 2002 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1480499

Deficiency record · 11

Engineering › Fuel Oil Service System › Tank
Issued 17 February 2016 Resolved
A gasoline fuel leak was discovered underneath the independent fuel tank. The source of the leak could not be immediately identified.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 March 2016
Resolved 22 March 2016
Resolution: New fuel tank installed in vessel.
Engineering › Steering Gear System › Cable
Issued 8 August 2015 Resolved
Retaining nut that holds steering cable sheathing in place had fallen off allowing the sheating and the cable to move simultaneously previnting steerage of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2015
Resolution: Recieved system failure report. It was determined a loose coupler nut was the cause of the loss of steering. System was repaired and an in/out of water test was satisfactorily completed.
Engineering › Pressure Vessel › Marking and Stamping
Issued 9 December 2009 Resolved
Prove proper installation of pressure vessels used for axel housing low air pressurization system.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 21 September 2011
Resolution: System modified to reduce maximum pressure to 15 psi or less excluding unfired pressure vessel from requirement.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 22 February 2007 Resolved
Proof test vessels' heat detection system prior to carrying passengers once each day of commercial use. Conduct a visual inspection fore Fire or Smoke on vessels' bilge compartment every 10 minutes while underway with passengers onboard. Upgrade vessels' Heat Detection System to include Electrical Supervision and two sources of power (vital circuit) by dates provided by your company to the OCMI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 22 August 2007
Resolution: Company upgraded Heat Detection System to include Electrical Supervision and two sources of power.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 25 October 2005 Resolved
Properly renew FWD drive shaft, bulkhead boot seal for the front wheels. Existing boot is showing early signs of dry rotting, cracking.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2005
Construction/Loadline › Structures › Scuttle
Issued 25 October 2005 Resolved
Properly renew worn FWD void, hatch cover gasket. Existing gasket is worn and not sealing properly.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2005
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 12 October 2004 Resolved
Properly label heat detector alarm box.
Condition: Improper/Lack of Maintenance
Due 12 October 2004
Resolved 12 October 2004
Engineering › Gasoline Engine (propulsion) › Backfire Flame Control
Issued 12 October 2004 Resolved
Properly replace the engine's carburetor's flame arrester.
Condition: Improper/Lack of Maintenance
Due 12 October 2004
Resolved 12 October 2004
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 12 October 2004 Resolved
Prove proper operation of vapor detector audible and visible alarm indicator box on the operator's console panel.
Condition: Unknown
Due 12 October 2004
Resolved 12 October 2004
Resolution: Installed new vapor detector indicator box.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 12 October 2004 Resolved
Prove proper operation of fwd vapor detector.
Condition: Unknown
Due 12 October 2004
Resolved 12 October 2004
Resolution: New vapor detector installed.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 16 December 2003 Resolved
Properly install engine space ventilation blower as per 46 CFR 182.460
Condition: Improper Installation
Due 17 March 2004
Resolved 12 October 2004

Ownership record