MAURY USCG vessel records Sign in
← All vessels

STRETCH DUCK 18

STRETCH DUCK 18 is a passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2002, most recently in August 2019, along with 15 deficiencies — 2 with no resolution recorded —.

Records from 2002 to 2019. Most recent: inspection, 19 August 2019.

Built
Not recorded
Last inspected
19 August 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

511293
Flag
UNITED STATES
—
Maury page id
psix-511293

Inspections, by type

…with no type recorded2
Years with a record 14 calendar years (2002–2019)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 24

19 August 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6788018
15 May 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6680375
8 February 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6622646
22 August 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6519715
13 July 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6478041
16 March 2017 Administrative Inspection · Plan Review "T" Boat · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6108219
18 February 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5825558
13 June 2012 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4343106
21 September 2011 Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4162262
9 December 2009 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3653015
29 April 2009 COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3454394
25 February 2009 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3426493
26 March 2008 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3162965
16 May 2007 Hull Examination · Annual Inspection · Internal Structural Exam · In-Service Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2891477
7 October 2006 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2865923
27 July 2006 Annual Inspection · Examination of Repairs · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2534647
19 April 2005 Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2328695
1 March 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2301512
28 April 2004 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2053986
24 March 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1779098
28 March 2002 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1647067
25 March 2002 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1597249
6 March 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1495240
28 January 2002 COI Inspection · Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1481118

Deficiency record · 15

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 February 2019 No resolution recorded
Prior to resuming vessel operations, company must demonstrate compliance with new Conditions of Operation listed on Amended COI to the satisfaction of attending Coast Guard marine inspector
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 August 2018 No resolution recorded
Prior to oeprating with passengers, an underway operational test to the satisfaction of the Coast Guard marine inspector must be completed.
Action required: 17 - Rectify deficiencies prior to departure
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 April 2017 Resolved
Mid-ship bilge alarm gave a visual alarm but no audible alarm upon activation of float switch.
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 5 April 2017
Resolution: Repaired mid-ship bilge alarm. Upon activation of float switch a visual and audible alarm occurred.
Engineering › Reduction Gearing/Clutches › Bearing, Line Shaft
Issued 13 June 2012 Resolved
Replace seal on pillar block (line shaft bearing). Aft seal is starting to slip away from its designed position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2012
Resolved 22 June 2012
Resolution: The piller block was removed, both grease seals and the bearing were replaced. The piller block was reinstalled and the vessel was tested on Table Rock Lake with satisfactory results.
Engineering › Pressure Vessel › Marking and Stamping
Issued 9 December 2009 Resolved
Prove proper installation of pressure vessels used for axel housing low air pressurization system.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 21 September 2011
Resolution: System modified to reduce maximum pressure to 15 psi or less excluding unfired pressure vessel from requirement.
Construction/Loadline › Hull › Bracket
Issued 26 March 2008 Resolved
Properly repair stern stair brace steel to original
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2008
Resolved 14 April 2008
Construction/Loadline › Hull › Side Shell
Issued 26 March 2008 Resolved
Properly repair stern void exterior wasted steel back to original.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2008
Resolved 14 April 2008
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 22 February 2007 Resolved
Proof test vessels' heat detection system prior to carrying passengers once each day of commercial use. Conduct a visual inspection fore Fire or Smoke on vessels' bilge compartment every 10 minutes while underway with passengers onboard. Upgrade vessels' Heat Detection System to include Electrical Supervision and two sources of power (vital circuit) by dates provided by your company to the OCMI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 25 July 2007
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 14 November 2005 Resolved
Prove proper operation of vessel underway prior to placing back in service.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 May 2006
Engineering › Bilge Water Management System › Pump
Issued 19 April 2005 Resolved
Electrical feed wire to the bilge float in engine compartment, had the insulation melted from being to close to engine headed.
Condition: Improper Installation
Due 19 April 2005
Resolved 19 April 2005
Resolution: Secured wire away from header and replace bad section of wire.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 March 2003 Resolved
Ensure all life jackets and ring buoys are proparly labeled with the vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2003
Communications › Radio Communications
Issued 24 March 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 24 April 2003
Resolved 21 April 2003
Resolution: Vsl is rqd by local BALMS policy to have a VHF radio O/B but is not required by regulation to have an FCC Station License, Safety Certificate or Marine Operators Permit.
Stability
Issued 28 January 2002 Resolved
Properly install reference marks to ensure they are visible from operator's station. LEGACY COMPONENT DESC: Reference Marks
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2002
Resolved 28 January 2002
Electrical › Electrical Distribution System (service)
Issued 28 January 2002 Resolved
Wire electrical panel to approved plans. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 28 January 2002 Resolved
Replace expired items in First Aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.