Records from 2002 to 2019. Most recent: inspection, 19 August 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
19 August 2019
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6788018
15 May 2019
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6680375
8 February 2019
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6622646
22 August 2018
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6519715
13 July 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6478041
16 March 2017
Administrative Inspection · Plan Review "T" Boat · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6108219
18 February 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5825558
13 June 2012
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4343106
21 September 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4162262
9 December 2009
In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3653015
29 April 2009
COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3454394
25 February 2009
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3426493
26 March 2008
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3162965
16 May 2007
Hull Examination · Annual Inspection · Internal Structural Exam · In-Service Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2891477
7 October 2006
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2865923
27 July 2006
Annual Inspection · Examination of Repairs · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2534647
19 April 2005
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2328695
1 March 2005
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2301512
28 April 2004
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2053986
24 March 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1779098
28 March 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1647067
25 March 2002
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1597249
6 March 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1495240
28 January 2002
COI Inspection · Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1481118
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 February 2019
No resolution recorded
Prior to resuming vessel operations, company must demonstrate compliance with new Conditions of Operation listed on Amended COI to the satisfaction of attending Coast Guard marine inspector
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 August 2018
No resolution recorded
Prior to oeprating with passengers, an underway operational test to the satisfaction of the Coast Guard marine inspector must be completed.
Action required: 17 - Rectify deficiencies prior to departure
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 April 2017
Resolved
Mid-ship bilge alarm gave a visual alarm but no audible alarm upon activation of float switch.
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 5 April 2017
Resolution: Repaired mid-ship bilge alarm. Upon activation of float switch a visual and audible alarm occurred.
Engineering › Reduction Gearing/Clutches › Bearing, Line Shaft
Issued 13 June 2012
Resolved
Replace seal on pillar block (line shaft bearing). Aft seal is starting to slip away from its designed position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2012
Resolved 22 June 2012
Resolution: The piller block was removed, both grease seals and the bearing were
replaced. The piller block was reinstalled and the vessel was tested on
Table Rock Lake with satisfactory results.
Engineering › Pressure Vessel › Marking and Stamping
Issued 9 December 2009
Resolved
Prove proper installation of pressure vessels used for axel housing low air pressurization system.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 21 September 2011
Resolution: System modified to reduce maximum pressure to 15 psi or less excluding unfired pressure vessel from requirement.
Construction/Loadline › Hull › Bracket
Issued 26 March 2008
Resolved
Properly repair stern stair brace steel to original
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2008
Resolved 14 April 2008
Construction/Loadline › Hull › Side Shell
Issued 26 March 2008
Resolved
Properly repair stern void exterior wasted steel back to original.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2008
Resolved 14 April 2008
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 22 February 2007
Resolved
Proof test vessels' heat detection system prior to carrying passengers once each day of commercial use. Conduct a visual inspection fore Fire or Smoke on vessels' bilge compartment every 10 minutes while underway with passengers onboard. Upgrade vessels' Heat Detection System to include Electrical Supervision and two sources of power (vital circuit) by dates provided by your company to the OCMI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 25 July 2007
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 14 November 2005
Resolved
Prove proper operation of vessel underway prior to placing back in service.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 May 2006
Engineering › Bilge Water Management System › Pump
Issued 19 April 2005
Resolved
Electrical feed wire to the bilge float in engine compartment, had the insulation melted from being to close to engine headed.
Condition: Improper Installation
Due 19 April 2005
Resolved 19 April 2005
Resolution: Secured wire away from header and replace bad section of wire.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 March 2003
Resolved
Ensure all life jackets and ring buoys are proparly labeled with the vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2003
Communications › Radio Communications
Issued 24 March 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 24 April 2003
Resolved 21 April 2003
Resolution: Vsl is rqd by local BALMS policy to have a VHF radio O/B but is not required by regulation to have an FCC Station License, Safety Certificate or Marine Operators Permit.
Stability
Issued 28 January 2002
Resolved
Properly install reference marks to ensure they are visible from operator's station. LEGACY COMPONENT DESC: Reference Marks
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2002
Resolved 28 January 2002
Electrical › Electrical Distribution System (service)
Issued 28 January 2002
Resolved
Wire electrical panel to approved plans. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 28 January 2002
Resolved
Replace expired items in First Aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2002