MAURY USCG vessel records
← All vessels

PRESIDENT WILSON

Built
Not recorded
Last inspected
5 July 2024
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 July 2024
…with no type recorded19
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9218686
WDG8555
511295
Flag
UNITED STATES
Maury page id
psix-511295

Documentation record

Tonnage as PSIX records it67965 - Dead Weight, Ton
92439 - Displacement, Ton
65792 - Convention (Subpart B), Gross Ton
36412 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 66 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 66

5 July 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8060631
11 March 2024 Annual Inspection · MSP Annual Oversight · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7841456
20 December 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7912889
9 October 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7806036
22 February 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7639901
22 February 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7640405
1 February 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7636734
31 January 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7630168
26 January 2023 Annual Inspection · Deficiency Check · MSP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7616603
21 January 2023 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7625007
21 January 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7626499
19 November 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7597064
7 September 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7553987
30 August 2022 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7546794
11 August 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7531044
5 July 2022 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7510480
4 July 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7496800
30 May 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7522641
2 March 2022 MSP Select Drydock Oversight · MSP Select Additional Oversight – Risk Assessment · Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7404190
15 November 2021 MSP COI Oversight · COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7328396
23 August 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7294239
22 August 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7293815
25 July 2021 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7267729
3 July 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7247367
18 May 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7200755
18 May 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7201041
21 March 2021 Deficiency Check · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7159965
20 March 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7221485
12 December 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7110587
24 October 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7084028
4 September 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7049778
10 June 2020 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6972632
21 May 2020 Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6959700
27 April 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6945222
29 March 2020 Damage Survey
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6932797
8 February 2020 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6911173
28 January 2020 MSP Annual Oversight · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6898287
6 December 2019 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6868420
25 November 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6861690
6 November 2019 Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6850616
17 August 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6786311
22 May 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6691071
11 April 2019 Annual Inspection · MSP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6656687
3 October 2018 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6685323
19 September 2018 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6544365
23 August 2018 MSP Select Additional Oversight – Risk Assessment · MTSA/ISPS Verification
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6521148
21 February 2018 Annual Inspection · MSP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6368430
11 January 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6340501
28 November 2017 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6316464
5 November 2017 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6346724
17 October 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6289740
27 September 2017 Administrative Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6280036
12 September 2017 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6265407
13 June 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6175882
12 June 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6188255
23 March 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6128535
1 February 2017 COI Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6062921
22 November 2016 Drydock Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6045594
6 May 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5870625
13 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5836039
5 April 2016 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5847551
2 March 2016 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5825832
19 February 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5821768
9 February 2016 Administrative Inspection · Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 5811845
8 February 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5812487
5 February 2016 Administrative Inspection · Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 5811821

Deficiency record · 37

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 March 2024 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that appropriate corrective action is taken. During annual inspection, MI discovered 95 overdue engineering maintenance items and 26 active alarms that were reposed. A Safety Management Audit carried out by the RO is required within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2024
Resolved 12 April 2024
Resolution: Vessel conducted satisfactory Safety Management Audit in Busan on 12APR.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2024 Resolved
Electrical installation in safety lights on stern of vessel need to be installed properly.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 March 2024
Resolved 13 March 2024
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 11 March 2024 Resolved
Ceased capstans and rollers as indicated throughout the vessel. USCG identified these to the [name withheld].
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 March 2024
Resolved 13 March 2024
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 11 March 2024 Resolved
Gangway railing missing eyelets on 2 stanchions for safety line.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 March 2024
Resolved 13 March 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 January 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported a loss of propulsion due to lube oil pump failure. Vessel is required to have repairs approved to the satisfaction of an attending CLASS and Coast Guard inspector prior to movement from berth. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 February 2023
Resolution: Vessel provided satisfactory class report of repair and subsequent operational tests.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 January 2023 Resolved
Doors provided to ensure the watertight integrity of internal openings which are used while at sea are to be sliding watertight doors capable of being operable locally from each side of the bulkhead. MI found class 3 water tight door in (in engine room near the stern tube) to have an inoperable local closure control.74 SOLAS (04) II-1 / 25-9.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 January 2023
Resolution: Accepted by Class as a CC
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship is fit to proceed to sea. 0-4 Deck WTD found with hole through door. 74 Solas ('01) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 November 2021
Resolved 15 November 2021
Resolution: Bolt installed in hole.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 November 2021 Resolved
Hydraulic power operated steering gear shall be provided with arrangements to maintain the cleanliness of the hydraulic fluid. Steering gear #1 and #2 leaking hydraulic fluid. 74 Solas (01) II-1/29.12.1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 November 2021
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 November 2021 Resolved
Means shall be provided to close all openings which may admit air to or allow gas to escape from a protected space. #4, 5, 6 dampers not closuing during fire test of CO2. Filter in valve preventing closure. 74 SOLAS (01) II-2/5.1.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 November 2021
Resolved 18 November 2021
Resolution: Cleaned out during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 November 2021 Resolved
Machinery and associated piping systems shall be so installed and protected as to reduce to a minimum any danger to persons onboard, due regard being paid to hot surfaces and other hazards. HFO piping had leaked previously, causing lagging to be fuel saturated. 744 SOLAS (01) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 November 2021 Resolved
Ships shall be designed, constructed and maintained in accordance with the structural, mechanical and electrical requirements of a classification society recognized by the administration. P/S Upper Louvers in Fiddley had air leak on actuator. 74 SOLAS (01) II-1/3-1
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 November 2021
Resolved 18 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 November 2021 Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the code. Port lifeboat with damage to stbd rubrail underside. SOLAS 74 (14) III/34
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 November 2021
Resolution: Accepted as condition of class.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 15 November 2021 Resolved
A minimum of two two-way portable radiotelephone apparatus for each fire party for fire-fighters' communication shall be carried on board. Two radios for fire team not present. SOLAS 74 (14) II-2/10.4
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 November 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 November 2021 Resolved
Ships shall be designed, constructed and maintained in accordance with the structural, mechanical and electrical requirements of a classification society recognized by the administration. Deck beam on MDE platform missing bolt. 74 SOLAS (01) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 November 2021
Resolved 18 November 2021
Resolution: Accepted as condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 November 2021 Resolved
Each life raft shall be stowed with a float free arrangement complying with the requirements of paragraph 4.1.6 of the code. Hydrostatic releases for life rafts did not have expiry date.SOLAS 74 (14) III/13.4.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 18 November 2021
Resolved 18 November 2021
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 November 2021 Resolved
Ships shall be designed, constructed and maintained in accordance with the structural, mechanical and electrical requirements of a classification society recognized by the administration. Temporary MSD repairs for air line. 74 SOLAS (01) II-1/3-1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 18 November 2021
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2021 Resolved
The electrical power available shall be sufficient to supply all those service that are essential for safety in an emergency, due regard being paid to such services as may be operated simultaneously. The vessels emergency generator is non operational and will not supply the required electrical power to essential equipment in an emergency. The vessel must either, 1. bring the emergency generator back into full operational service or, 2. Test the #1 generator to full load proving proper operation prior to movement. 74SOLAS II-2/43.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 18 May 2021
Resolved 19 May 2021
Resolution: Vessel made proper repairs to their emergency generator and proved functionality of their #1 generator to the satisfaction of the Coast Guard.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 21 March 2021 Resolved
The International Shore Connection shall be kept on board with a gasket. Crew repalced gasket on the spot.
Action required: 10 - Deficiency Rectified
Due 21 March 2021
Resolved 21 March 2021
Resolution: Def cleared
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 21 March 2021 Resolved
Before the ship leaves port the medical chest shall be stocked and readily accessible. Medicine cabinet needs to be reorganized to provide easy access to needed medicines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2021
Resolved 6 April 2021
Resolution: def cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 March 2021 Resolved
The boilers shall be of a design and construction adequate for the service intended. Following a fire in Auxiliary Boiler crew must make repairs to refractory on the burner and clean firetubes.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
Resolution: Vessel made repairs and DNV-GL verified proper operation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 March 2021 Resolved
In spaces where penetration of oil products is possible, the surface or insulation shall be impervious to oil. Insultation on NO1 generator fuel supply is damage and needs repair and replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2021
Resolved 26 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2020 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. Identified fuel or oil leaks on the following equipment: EDG fuel return line, Fuel service pump for boiler, Lub oil leak on main engine camshaft lub oil inlet valve, Lube oil leak on EDG oil pressure sender & inboard section of oil pan.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2020
Resolution: All leaks repaired with exception: A condition is issued for leaking inlet valve for Lub. ol cooler (ref. DNV GL survey report no.1411861)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 January 2020 Resolved
The condition of the ship & its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Identified water leak on the ballast ejector pump shaft seal & coolant leak on EDG radiator.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 January 2020
Resolution: Repaired / Rectified: Ballast Ejector Pump :As reported by Chief Engineer, the leak was from sealing water line. The damged sealing water line is now replaced and inspected the pump when working and found no leaks. Coolant leak is addressed by a condition
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 28 January 2020 Resolved
The company should establish procedures, plans & instructions, including checklist as appropriate, for the key shipboard operations concerning the safety of the personnel, ship & protection of the environment. The various task should be defined & assigned to qualified personnel. Identified improper completion, filling out, signing of daily & Pre-UMS checklist Doc# T141. Recommend internal audit.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 June 2020
Resolution: Vessel supplied a completed an audit and spot check of check sheet over a period of time. Chief to review T141 daily & Captain weekly for proper completion.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 January 2020 Resolved
Vessel had an open condition of class for the ventilation dampeners #3 & #4. MI operationally tested all engine room ventilation dampeners from remote station and discovered dampener #4 & #5 did not fully close.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 January 2020
Resolved 28 January 2020
Resolution: It was identified the venting of the air valves to be partially blocked thus not allowing the full bleed off of air pressure which resulted in the dampeners not fully closing. Vessel was able to have shoreside support attend the vessel and complete repair
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 January 2020 Resolved
Identified fuel leak on the boiler fuel return line.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 January 2020
Resolved 28 January 2020
Resolution: Vessel was able to repair and clean area.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 January 2020 Resolved
Identified residual lube oil accumulation in the vicinity of the #3 generator.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 January 2020
Resolved 28 January 2020
Resolution: Vessel was able to clean the area.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 January 2020 Resolved
Vessel had hold backs (rope) holding both of the purifier doors open.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 January 2020
Resolved 28 January 2020
Resolution: Vessel removed rope from holding doors open.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 November 2019 Resolved
Measures shall be taken to the satisfaction of the administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. Received report of failure to #1 DG HFO Circulation Pump, and auto changeover automation failure resulting in temporary loss of power. Demonstrate proper operation of SSDGs including automatic changeover between on line and standby SSDGs functions as designed. SOLAS 74 a (2004 Cons)II-1/46.2 --16a
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2019
Resolution: Received DNV-GL survey statement that fuel circulating pump was repaired after bearing damage was discovered in the pump. Also, the "over current relay" was set to "manual" mode rather than "auto". These were rectified and system tested satisfactorily.
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Drum Safety
Issued 21 February 2018 Resolved
Remove paint from both safety valves and make legible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2018
Resolved 21 February 2018
Resolution: Crew removed paint from both safeties and made legible.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 21 February 2018 Resolved
Prove proper operation of all engine room supply/exhaust fire dampers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2018
Resolved 21 February 2018
Resolution: Witnessed proper operation of all engine room supply/exhaust dampers.
Engineering › Pressure Vessel › Relief Valve
Issued 21 February 2018 Resolved
Prove proper operation of all pressure vessel relief valve hand relieving devices.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 February 2018
Resolved 21 February 2018
Resolution: Witnessed proper operation of all relief valve hand relieving devices.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 28 November 2017 Resolved
Insulation damaged by exterior fire
Action required: 705 - Other - as specified
Resolved 21 February 2018
Resolution: Found insulation installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 November 2017 Resolved
Lighting fixture damaged by exterior fire
Action required: 705 - Other - as specified
Resolved 21 February 2018
Resolution: Light was replaced and operational.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 22 September 2017 Resolved
Vessel is to operate a fully manned e/r until the remaining MDE main bearings (1-10) are inspected for damage/failure. The ACCU notation was removed on the Interim Class Certificate.
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 17 October 2017
Resolution: EO notation reinstated by DNV.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 14 June 2017 Resolved
Determine cause of fuel injector failure and conduct required repairs. Provide technical report to the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 June 2017
Resolved 15 June 2017
Resolution: Repairs completed and verified.
Engineering › Lubricating Oil Service System › Pump
Issued 9 February 2016 Resolved
Vessel must have means to restore propulsion after the failure of an essential auxiliary. Following failure of #1 Main cylinder L.O. pump, vessel does not have redundancy of cylinder lubrication system. SOLAS(74) II-2 REG 26.3.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2016
Resolved 9 February 2016
Resolution: Upon issuance of CG-835 vessel captain called stating that the Cheng had taken the pump apart, re-assembled, and tested sat numerous times. Requested Cheng/Captain provide written/signed statement of actions taken to rectify problem. Class notified.

Recorded names · 1

APL BELGIUM (2013–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record