MAURY USCG vessel records Sign in
← All vessels

MICHELE

MICHELE is a 2002 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2002, most recently in January 2010, along with 7 deficiencies — 2 with no resolution recorded — and 2 casualty investigations in 2004.

Records from 2002 to 2010. Most recent: inspection, 29 January 2010.

Built
2002
Last inspected
29 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

511345
Flag
UNITED STATES
—
Maury page id
psix-511345

Inspections, by type

…with no type recorded2
…past their stated due date2
Years with a record 6 calendar years (2002–2010)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it47 - Simplified, Gross Ton
37 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

29 January 2010 Hull Examination · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3672235
22 March 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2608724
2 May 2005 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2347481
4 August 2004 In-Service Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2155655
10 May 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2063608
18 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2056204
24 March 2004 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2029758
22 February 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2011987
30 April 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1783375
27 September 2002 In-Service Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1680923
29 May 2002 Initial Certification · Simplified Stability Test
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1622863
28 May 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1621743
4 April 2002 Construction Oversight
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1492605

Deficiency record · 7

Engineering › Bilge Water Management System › Valve
Issued 22 March 2006 No resolution recorded
Install positive control valves at the hull for all electric submersible pumps.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2006 — due date passed with no resolution recorded
Engineering › Electric Propulsion System › Battery
Issued 22 March 2006 No resolution recorded
Complete removal of batteries and associated equipment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2006 — due date passed with no resolution recorded
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 August 2004 Resolved
Vsl failed Simpilified Sub-Division, provide a proposal to bring all the vessels in compliance. The proposal is due no later than 01 September 2004 for work to be completed on all vessels no later than 01 January 2005
Condition: Improper Installation
Due 31 August 2004
Resolved 3 May 2005
Resolution: Foam installed and new stability letter issued.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 March 2004 Resolved
Provide containment around all batteries.
Due 24 May 2004
Resolved 1 May 2005
Electrical
Issued 27 September 2002 Resolved
Provide generator with 50 deg Centergrade ambient temp rating or derate to 80% or demonstrate ambient temp does not exceed 40 deg Centergrade
Action required: 705 - Other - as specified
Due 5 November 2002
Resolved 12 December 2002
Resolution: Generator manufacturer provide additional ambient temperature rating specification information. Generator does meet required ambient temperature rating. New information plate reflecting this rating has been attached to generator.
Fire Fighting › Fixed Fire Detection System
Issued 29 May 2002 Resolved
Auxillary equipment room requires heat detection, general purpose resin was used for machinery space boundary. 177.410) LEGACY COMPONENT DESC: Heat Detectors
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2002
Engineering › Fuel Oil Service System › Valve
Issued 29 May 2002 Resolved
Fuel shut-off valve at the engine is missing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2002

Casualty record · 2

22 February 2004Routine · role: Involved in a Marine Casualty · activity 2011987
18 April 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2056204
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.