Records from 1985 to 2026. Most recent: inspection, 9 June 2026.
Documentation record
Registered dimensions (L × B × D)32.1 ft × 10.0 ft × 3.2 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPAYNE & FRANKLIN, INC. · N. KINGSTOWN, RI, UNITED STATES · built 1980
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Regulatory (Subpart C or D), Gross Ton
6 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 48
9 June 2026
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8368584
5 June 2024
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7887039
24 April 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7887032
28 March 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7886402
12 May 2022
Administrative Inspection · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7419718
18 August 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7036161
13 June 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6712123
6 May 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6677668
19 June 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6448296
13 June 2017
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6174251
14 June 2016
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5906869
18 June 2014
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4892434
12 June 2012
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4341896
3 May 2012
Deficiency Check · Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4302064
9 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4205224
14 April 2009
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3452379
10 June 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3232942
13 June 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2960190
14 June 2006
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2679412
15 June 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2391150
16 June 2004
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2098005
26 April 2004
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2048108
11 June 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1814080
1 May 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1611172
24 April 2002
Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1608596
12 June 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1066677
2 May 2001
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1410547
21 June 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1395483
25 May 1999
Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 799732
10 June 1998
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126093
4 June 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1109658
12 June 1996
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1088511
7 June 1995
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 876948
8 June 1994
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1019420
16 May 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1169928
17 June 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1135203
9 July 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 944685
10 June 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 957998
11 June 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 912946
31 May 1990
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1236148
13 September 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1194973
13 September 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1342308
22 May 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1041273
17 May 1988
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1351266
14 May 1987
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1024454
16 May 1986
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 996109
21 May 1985
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1297378
15 March 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1288693
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 June 2026
No resolution recorded
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in § 176.500(b)(1) and your Certificate of Inspection must be endorsed. Vessel did not conduct an annual inspection within the allowed timeframe so COI is now invalid. Complete a COI inspection prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 June 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel was missing 02 fire buckets and their associated lanyards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 13 June 2024
Resolution: Vessel representative sent picture of 03 fire buckets for vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 March 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel missed its annual inspection. Vessel must undergo an inspection for certification prior to operations.
46 CFR 176.500(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2024
Resolved 5 June 2024
Resolution: Conducted satisfactory COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 May 2022
Resolved
Submersible electric bilge pump shall have a positive control valve installed at the hull penetration. The vessel's two bilge pump discharges have a check valve installed. Install a positive control valve for both lines, at the hull penetration.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 29 June 2022
Resolution: Vessel granted special consideration to use check valve instead of positive control valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 May 2022
Resolved
A vessel must be provided with bilge pumps. The aft pump did not operate in automatic mode and the fwd pump was not operable at all. Ensure both pumps are operable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 21 June 2022
Resolution: Both bilge pumps fully operational. Test:SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2022
Resolved
The watertight on a vessel carrying only one ring buoy must be attached to the lanyard with a corrosion resistant clip. The vessel is currently using a twisting attachment for the watertight. Replace this with a corrosion resistant clip.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 21 June 2022
Resolution: O/O installed new corrosion resistant clip.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 June 2019
Resolved
A submersible electric bilge pump may be used provided a positive shutoff valve is installed at the hull penetration. No valve is installed at the hull penetration.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2019
Resolved 25 June 2019
Resolution: Valve was installed at thru hull.
Documentation › Certificates/Documents › Stability Letter
Issued 9 December 2011
Resolved
The vessel's owner/operator has not requested an initial or updated stability letter or h as not certified compliance with the revised stability criteria for assumed average weight per person (AAWPP) of 185 pounds. Based upon a weight ratio calculation, the vessel's capacity is therefore limited to: nn persons (passengers and crew). 46 CFR 170.090
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 3 May 2012
Resolution: Stability test completed on PATRICK TRACY JACKSON, ON D634854. Vessel''s COI changed to 27 persons.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 16 June 2004
Resolved
Install PFD donning placards for both types of jackets.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 16 June 2004
Resolved
Provide flashlight and mount by operator.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Electrical › Electrical Distribution System (service) › Switch
Issued 16 June 2004
Resolved
Label bilge alarm switch to be "ON" while operating.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Lifesaving › Lifebuoys › Serviceable
Issued 16 June 2004
Resolved
Prior to carrying passengers provide ring buoy.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 16 June 2004
Resolved
Provide Emergency Instructions.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Lifesaving › Lifebuoys
Issued 11 June 2003
Resolved
Vessel is limited to daytime ops until water light is repaired. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 30 June 2003
Engineering › Bilge Water Management System
Issued 11 June 2003
Resolved
Prove proper operation of electric bilge pump prior to carrying passengers. LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2003
Resolved 30 June 2003
Navigation › Collision/Grounding Avoidance
Issued 11 June 2003
Resolved
Vessel is limited to daytime until anchor light is repaired. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 30 June 2003
Lifesaving › Lifebuoys
Issued 11 June 2003
Resolved
Install retro reflective tape on ring buoy.
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 30 June 2003
Lifesaving
Issued 25 May 1999
Resolved
REPLACE WORN RING BUOY.
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Engineering
Issued 25 May 1999
Resolved
INSTALL FLAME SCREEN ON BOTH FUEL TANK VENTS.
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Lifesaving
Issued 10 June 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Lifesaving
Issued 11 June 1991
Resolved
PRIOR TO CARRYING PASSENGERS CONDUCT EMERGENCY DRILLS WITH OPERATORS AND DECKHANDS AS OUTLINED IN NAVIC 1-91 DTD 20 FEB 91 IN PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991