Records from 1981 to 1993. Most recent: inspection, 26 May 1993.
Documentation record
Registered dimensions (L × B × D)95.9 ft × 21.5 ft × 6.8 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · JEAN LAFITTE, LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 23 September 1988
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 29
26 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 656137
22 March 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 692272
22 March 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 692273
4 January 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1142095
25 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 40198
25 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214897
25 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 227702
24 September 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410750
23 March 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1256108
15 March 1991
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 908199
20 August 1990
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225206
16 March 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238265
9 March 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915979
27 May 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1209375
16 March 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890567
2 November 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1201135
21 October 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 889078
31 March 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036977
24 March 1987
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019208
19 February 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322910
6 January 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004807
17 December 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318455
15 September 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327539
29 April 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293414
29 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983538
30 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972510
30 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966546
15 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963956
9 April 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964756
Electrical
Issued 9 March 1990
Resolved
PROVIDE APPROVED ELECTRICAL MAT FOR SWITCHBOARD.
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Electrical
Issued 9 March 1990
Resolved
INSTALL LENS COVER FOR LIGHT IN GENERATOR SPACE.
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Navigation
Issued 9 March 1990
Resolved
PROVE PROPER OPERATION OF SINGLE SIDE BAND RADIO
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Navigation
Issued 9 March 1990
Resolved
PROVIDE APPROVED/PROPER SIZE BELL.
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Accommodation/Occupational Safety
Issued 9 March 1990
Resolved
REPAIR STOVE LIGHT AND EXHAUST FAN.
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Electrical
Issued 16 March 1989
Resolved
MAKE OPERABLE THE OVERSPEED TRIP ON THE STARBOARD GENERATOR TO COMPLY WITH 46 CFR 183.10-35(G).
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Electrical
Issued 16 March 1989
Resolved
MAKE OPERABLE THE PORT, CENTER, STARBOARD ENGINE AND GENERATOR ALARM PANEL TO COMPLY WITH 46 CFR 176.30-1.
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Lifesaving
Issued 17 December 1986
Resolved
REPAIR BROKEN HOOK ON LIFE LINE ON 25 MAN LIFE BOAT.
Condition: Unknown
Due 17 December 1986
Resolved 17 December 1986
Lifesaving
Issued 17 December 1986
Resolved
ENSURE WATERLIGHT FOR LIFE FLOAT IS OPERABLE.
Condition: Unknown
Due 17 December 1986
Resolved 17 December 1986
Engineering
Issued 17 December 1986
Resolved
PROVIDE FLAME SCREEN FOR LUBE OIL VENT ON PORT SIDE AFT DECK.
Condition: Unknown
Due 17 December 1986
Resolved 17 December 1986
Engineering
Issued 17 December 1986
Resolved
FREE UP ENGINE ROOM VENT AND BLOWN DAMPERS LOCATED ON AFT DECK AREA.
Condition: Unknown
Due 17 December 1986
Resolved 17 December 1986
Fire Fighting
Issued 17 December 1986
Resolved
PRIOR TO PLACING VESSEL INTO SERVICE RECHARGE OR REPLACE DISCHARGED ABCII DRY CHEMICAL FIRE EXTINGUISHER LOCATED IN UPPER PASSENGER ACCOMODATION SPACE.
Condition: Unknown
Due 17 December 1986
Resolved 17 December 1986
Fire Fighting
Issued 17 December 1986
Resolved
PRIOR TO PLACING VESSEL INTO SERVICE PROVIDE SERVICEABLE 50 FOOT FIRE HOSE TO REPLACE EXISTING HOLED HOSE.
Condition: Unknown
Due 17 December 1986
Resolved 17 December 1986
Fire Fighting
Issued 17 December 1986
Resolved
PRIOR TO PLACING VESSEL INTO SERVICE REPAIR OR REPLACE BROKEN VALVE WHEEL FOR DECK FIRE STATION.
Condition: Unknown
Due 17 December 1986
Resolved 17 December 1986
Engineering
Issued 17 December 1986
Resolved
REPAIR OR REPLACE MISSING VALVE WHEEL FOR PORT SIDE DECK EMERGENCY FUEL SHUT OFF.
Condition: Unknown
Due 17 December 1986
Resolved 17 December 1986
Documentation
Issued 17 December 1986
Resolved
PROVIDE COPY OF VALID CERFIFICATE OF INSPECTION ABOARD VESSEL.
Condition: Unknown
Due 17 December 1986
Resolved 17 December 1986
Lifesaving
Issued 17 December 1986
Resolved
STOW WORK VESTS SEPARATELY FROM LIFE JACKETS.
Condition: Unknown
Due 17 December 1986
Resolved 17 December 1986