MAURY USCG vessel records
← All vessels

DULUTH

DULUTH is a 1954 towing vessel. The Coast Guard has recorded 18 inspections since 2005, most recently in June 2026, along with 38 deficiencies and 1 operational control.

Records from 2005 to 2026. Most recent: inspection, 23 June 2026.

Built
1954
Last inspected
23 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDM4925
511585
Flag
UNITED STATES
Maury page id
psix-511585

Inspections, by type

Years with a record 10 calendar years (2005–2026)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)70.1 ft × 19.5 ft × 9.6 ft
Registered tonnagegross 87 / net 70
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMISSOURI VALLEY STEEL INC · LEVENWORTH, KS, UNITED STATES · built 1954
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMUSKEGON, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 March 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Simplified, Gross Ton
70 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 18

23 June 2026 COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8405344
22 December 2025 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8286313
27 October 2025 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8259349
8 November 2024 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8033353
27 October 2023 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7815330
19 September 2022 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7562190
31 March 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7422269
21 September 2021 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7333685
16 August 2021 Initial Certification · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7288142
2 June 2015 Industry Initiated Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5141517
11 May 2012 Deficiency Check
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4308362
4 May 2012 Deficiency Check
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4302088
3 May 2012 Risk-based Targeted Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4301797
29 November 2011 Administration
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4274319
8 December 2005 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2548253
5 December 2005 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2546050
24 October 2005 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2521182
17 October 2005 Administrative Inspection
Administrative · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2520807

Deficiency record · 38

10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 31 October 2023 Resolved
Navigation Assessments not being conducted on short transit evolutions. Ensure NAV assessments conducted each time prior to getting underway.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 November 2023
Resolved 1 November 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 October 2023 Resolved
Fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. Full records of inspection/testing not on board vessel. Provide records.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2023
Resolved 13 November 2023
Resolution: Recieveed records of testing and inspection of fire detection and alarm systems.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 October 2023 Resolved
Each liferaft must have a painter system providing a connection between the vessel and liferaft. Vessel's liferaft painter was not attached to weak link. 46 CFR 141.310 46 CFR 199.130(c)(6)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2023
Resolved 13 November 2023
Resolution: Received photo of correctly installed painter.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 October 2023 Resolved
Vessel EPIRB must be stowed with controls set for automatic activation so that it will float free. EPIRB hydrostatic release unit was expired. 46 CFR 141.310 46 CFR 199.130(c)(7)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2023
Resolved 13 November 2023
Resolution: Hydro static release replaced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 October 2023 Resolved
Portable fire extinguishers must be inspected in accordance with NFPA 10, and recorded by logbook or tag.Fire extinguishers aft of pilothouse was not being inspected and logged monthly. 46 CFR 142.240(a)(1) 46 CFR 142.240(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 13 November 2023
Resolution: Received photo of tag on fire extinguisher with the appropriate monthly inspection conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 October 2023 Resolved
Each lifebuoy must be marked in block capital letters with the vessel name. Port and stbd lifebuoys stenciling was faded. 46 CFR 141.360(b)(4)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 13 November 2023
Resolution: Recieved photo of new stenciling
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2023 Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan. Vessel did not have a fuel system maintenance plan. 46 CFR 143.255(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 13 November 2023
Resolution: Recieved photo of fuel maintenance plan and logging of items conducted on plan
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 27 October 2023 Resolved
The master shall ensure fire-fighting drills are conducted at least once each month. Fire drills were not being conducted at the required frequency. 46 CFR 142.245(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 October 2023
Resolved 31 October 2023
Resolution: Conduted fire drill
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 October 2023 Resolved
Individuals, who are not crewmembers, on board a towing vessel must receive a safety orientation prior to getting underway or as soon as practicable thereafter, to include: (a) The location, operation, and use of lifesaving equipment; (b) Emergency procedures; (c) Methods to notify crewmembers in the event of an emergency; and (d) prevention of falls onboard. Provide orientation to non crew.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 31 October 2023
Resolved 31 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 October 2023 Resolved
Each liferaft must be arranged for float-free launching. Liferaft hydrostatic release unit and weak link was installed upside down.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 31 October 2023
Resolved 13 November 2023
Resolution: Recieved photo of correctly installed assembly.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 27 October 2023 Resolved
The master shall ensure fire-fighting drills are conducted at least once each month. Fire drills were not being conducted at the required frequency.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 November 2023
Resolved 31 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 October 2023 Resolved
(a) All lifesaving equipment must be tested and maintained in accordance with the minimum requirements of § 199.190 of this chapter, as applicable, and the vessel's TSMS, if the vessel has a TSMS. (b) Inspections and tests of lifesaving equipment must be recorded in the TVR, official logbook, or in accordance with any TSMS applicable to the vessel. The following minimum information is required: (1) The dates when inspections and tests were performed, the number or other identification of each unit inspected and tested, the the results of the inspections and tests, and the name the crewmember, surveyor or auditor and any others conducting the inspections and tests; and (2) Receipts and other records documenting these inspections and tests must be retained for at least 1 year after the expiration of the COI and made available upon request. Lifesaving equipment inspection records inconsistently inspected and recorded. Ensure consistent inspections and recordkeeping maintained. 46 CFR 141.235
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2023
Resolved 13 November 2023
Resolution: Logs complete.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 19 September 2022 Resolved
All fire-extinguishing systems must be inspected / tested at least once every 12 months. Last FFE service date more than 12 months. Provide FFE servicing and maintenance documentation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2022
Resolution: Reviewed documentation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 September 2022 Resolved
Flammable / combustible products onboard must be stored in a designated storage room / cabinet with additional 40BC PFE when not in use. Propane tanks stored in metal cabinet without additional PFE and 01 propane tank stored outside of cabinet directly on deck. Store propane tanks IAW with requirements and provide additional 40 BC PFE for storage cabinet.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2022
Resolution: PFE added; propane tank removed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 September 2022 Resolved
Means to detect smoke that alerts crew must be equipped in berthing spaces. Heat detectors found in berthing areas. Provide smoke detectors in berthing areas.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2022
Resolution: Smoke detectors added to berthing and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 September 2021 Resolved
Install SOLAS B liferaft properly
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2021
Resolution: SOLAS B raft installed.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 10 September 2021 Resolved
Install properly serviced Immersion suits for all crewmembers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2021
Resolution: New suits were installed on vessel. 06
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 September 2021 Resolved
Provide onboard proper amount of Flares for route.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2021
Resolution: Installed proper amount of flares.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 September 2021 Resolved
Repair pin hole in super structure near/under the PORT weather deck door.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 October 2021
Resolution: Proper repair has been completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 September 2021 Resolved
Provide onboard approved “workvest” with lights for all crewmembers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2021
Resolution: New work vest provided to all crewmembers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 September 2021 Resolved
Provide lights and whistles for all type I lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2021
Resolution: Lights installed on all typeI jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 September 2021 Resolved
Conduct required maintenance, monthly and annual of all lifesaving appliances to include checklist for each item in accordance with manufacture instruction.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2021
Resolution: Checklist for all items were created.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 September 2021 Resolved
Install proper fire extinguisher bracket for the B-II installed near locker on main deck.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: New bracket is properly installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 September 2021 Resolved
Properly label fire station and fire pump controller in engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: fire pump has been labeled
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2021 Resolved
Provide onboard required fuel system maintenance program in accordance with manufacture recommendation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 September 2021
Resolution: Fuel system has program developed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 September 2021 Resolved
Repair damaged dog for STBD side air vent closure.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2021 Resolved
Remove daisy chain of extension cords powering the cooling fan for steering hydraulics.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2021
Resolution: Fan and extension cord have since been removed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 September 2021 Resolved
Install proper anchor light in accordance with navigation rules 2 mile visibility.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2021
Resolution: New Anchor light fixture has been installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 September 2021 Resolved
Relocate amber towing lights in vertical line.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2021
Resolution: All lights have been relocated to a vertical position.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 September 2021 Resolved
Provide onboard most current version of the navigation rules book.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 September 2021
Resolution: Nav rules book added.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 September 2021 Resolved
Provide onboard all required dayshapes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2021
Resolution: Day shapes have been added to vessel.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 September 2021 Resolved
Provide copy of FCC license for Master of vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2021
Resolution: Rcvd copy of the permit
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 10 September 2021 Resolved
Provide documentation for all crewmembers enrolled in DAPI with testing results.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 September 2021
Resolution: Enrollment roster reviewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 September 2021 Resolved
Install lagging on all exposed areas of the generator exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2021
Resolution: New lagging has been installed in missing sections.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 September 2021 Resolved
First aid kit, add means to splint broken bones.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 September 2021
Resolution: Means to splint added to first aid kit.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 September 2021 Resolved
Remove any and all flammable material from machinery space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 September 2021
Resolution: All items were removed from space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2021 Resolved
Provide info or replace both pressure vessels installed on STBD machinery space or stencil with relief valve pressure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 September 2021
Resolution: Air reciever has been labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 August 2021 Resolved
Provide onboard monthly /annual drills and instruction to include Health and Safety training/ Fire and Man overboard. 14SEP21: will be working with company safety officer to ensure regulation will be followed. extended this reg to 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 December 2021
Resolution: Rcvd Copy of H & S plan along with Station bill

Ownership record