← All vessels
DULUTH
DULUTH is a 1954 towing vessel. The Coast Guard has recorded 18 inspections since 2005, most recently in June 2026, along with 38 deficiencies and 1 operational control.
Records from 2005 to 2026. Most recent: inspection, 23 June 2026.
- Built
- 1954
- Last inspected
- 23 June 2026
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 38 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1123333
WDM4925
511585
Flag
UNITED STATES
Maury page id
psix-511585
Inspections, by type
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)70.1 ft × 19.5 ft × 9.6 ft
Registered tonnagegross 87 / net 70
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMISSOURI VALLEY STEEL INC · LEVENWORTH, KS, UNITED STATES · built 1954
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMUSKEGON, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 March 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Simplified, Gross Ton
70 - Simplified, Net Ton
70 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 18
23 June 2026
COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8405344
22 December 2025
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8286313
27 October 2025
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8259349
8 November 2024
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8033353
27 October 2023
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7815330
19 September 2022
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7562190
31 March 2022
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7422269
21 September 2021
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7333685
16 August 2021
Initial Certification · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7288142
2 June 2015
Industry Initiated Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5141517
11 May 2012
Deficiency Check
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4308362
4 May 2012
Deficiency Check
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4302088
3 May 2012
Risk-based Targeted Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4301797
29 November 2011
Administration
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4274319
8 December 2005
Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2548253
5 December 2005
Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2546050
24 October 2005
Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2521182
17 October 2005
Administrative Inspection
Administrative · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2520807
Deficiency record · 38
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 31 October 2023
Resolved
Navigation Assessments not being conducted on short transit evolutions. Ensure NAV assessments conducted each time prior to getting underway.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 October 2023
Resolved
Fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. Full records of inspection/testing not on board vessel. Provide records.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 October 2023
Resolved
Each liferaft must have a painter system providing a connection between the vessel and liferaft. Vessel's liferaft painter was not attached to weak link.
46 CFR 141.310
46 CFR 199.130(c)(6)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 October 2023
Resolved
Vessel EPIRB must be stowed with controls set for automatic activation so that it will float free. EPIRB hydrostatic release unit was expired.
46 CFR 141.310
46 CFR 199.130(c)(7)
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 October 2023
Resolved
Portable fire extinguishers must be inspected in accordance with NFPA 10, and recorded by logbook or tag.Fire extinguishers aft of pilothouse was not being inspected and logged monthly.
46 CFR 142.240(a)(1)
46 CFR 142.240(a)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 October 2023
Resolved
Each lifebuoy must be marked in block capital letters with the vessel name. Port and stbd lifebuoys stenciling was faded.
46 CFR 141.360(b)(4)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2023
Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan. Vessel did not have a fuel system maintenance plan.
46 CFR 143.255(a)
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 27 October 2023
Resolved
The master shall ensure fire-fighting drills are conducted at least once each month. Fire drills were not being conducted at the required frequency.
46 CFR 142.245(a)
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 October 2023
Resolved
Individuals, who are not crewmembers, on board a towing vessel must receive a safety orientation prior to getting underway or as soon as practicable thereafter, to include: (a) The location, operation, and use of lifesaving equipment; (b) Emergency procedures; (c) Methods to notify crewmembers in the event of an emergency; and (d) prevention of falls onboard. Provide orientation to non crew.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 October 2023
Resolved
Each liferaft must be arranged for float-free launching. Liferaft hydrostatic release unit and weak link was installed upside down.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 27 October 2023
Resolved
The master shall ensure fire-fighting drills are conducted at least once each month. Fire drills were not being conducted at the required frequency.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 October 2023
Resolved
(a) All lifesaving equipment must be tested and maintained in accordance with the minimum requirements of § 199.190 of this chapter, as applicable, and the vessel's TSMS, if the vessel has a TSMS. (b) Inspections and tests of lifesaving equipment must be recorded in the TVR, official logbook, or in accordance with any TSMS applicable to the vessel. The following minimum information is required: (1) The dates when inspections and tests were performed, the number or other identification of each unit inspected and tested, the the results of the inspections and tests, and the name the crewmember, surveyor or auditor and any others conducting the inspections and tests; and (2) Receipts and other records documenting these inspections and tests must be retained for at least 1 year after the expiration of the COI and made available upon request. Lifesaving equipment inspection records inconsistently inspected and recorded. Ensure consistent inspections and recordkeeping maintained.
46 CFR 141.235
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 19 September 2022
Resolved
All fire-extinguishing systems must be inspected / tested at least once every 12 months. Last FFE service date more than 12 months. Provide FFE servicing and maintenance documentation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 September 2022
Resolved
Flammable / combustible products onboard must be stored in a designated storage room / cabinet with additional 40BC PFE when not in use. Propane tanks stored in metal cabinet without additional PFE and 01 propane tank stored outside of cabinet directly on deck. Store propane tanks IAW with requirements and provide additional 40 BC PFE for storage cabinet.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 September 2022
Resolved
Means to detect smoke that alerts crew must be equipped in berthing spaces. Heat detectors found in berthing areas. Provide smoke detectors in berthing areas.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 September 2021
Resolved
Install SOLAS B liferaft properly
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 10 September 2021
Resolved
Install properly serviced Immersion suits for all crewmembers.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 September 2021
Resolved
Provide onboard proper amount of Flares for route.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 September 2021
Resolved
Repair pin hole in super structure near/under the PORT weather deck door.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 September 2021
Resolved
Provide onboard approved “workvest” with lights for all crewmembers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 September 2021
Resolved
Provide lights and whistles for all type I lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 September 2021
Resolved
Conduct required maintenance, monthly and annual of all lifesaving appliances to include checklist for each item in accordance with manufacture instruction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 September 2021
Resolved
Install proper fire extinguisher bracket for the B-II installed near locker on main deck.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 September 2021
Resolved
Properly label fire station and fire pump controller in engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2021
Resolved
Provide onboard required fuel system maintenance program in accordance with manufacture recommendation.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 September 2021
Resolved
Repair damaged dog for STBD side air vent closure.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2021
Resolved
Remove daisy chain of extension cords powering the cooling fan for steering hydraulics.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 September 2021
Resolved
Install proper anchor light in accordance with navigation rules 2 mile visibility.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 September 2021
Resolved
Relocate amber towing lights in vertical line.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 September 2021
Resolved
Provide onboard most current version of the navigation rules book.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 September 2021
Resolved
Provide onboard all required dayshapes.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 September 2021
Resolved
Provide copy of FCC license for Master of vessel.
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 10 September 2021
Resolved
Provide documentation for all crewmembers enrolled in DAPI with testing results.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 September 2021
Resolved
Install lagging on all exposed areas of the generator exhaust piping.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 September 2021
Resolved
First aid kit, add means to splint broken bones.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 September 2021
Resolved
Remove any and all flammable material from machinery space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2021
Resolved
Provide info or replace both pressure vessels installed on STBD machinery space or stencil with relief valve pressure.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 August 2021
Resolved
Provide onboard monthly /annual drills and instruction to include Health and Safety training/ Fire and Man overboard.
14SEP21: will be working with company safety officer to ensure regulation will be followed. extended this reg to 14 days.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.