Records from 1982 to 2008. Most recent: inspection, 1 July 2008.
Inspection history · 105
1 July 2008
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3326137
6 February 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3142854
28 January 2008
Deficiency Check · COC-MODU Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3137792
25 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2973984
10 January 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2819800
20 October 2005
COC-MODU Renew
Type not classified · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2518504
7 June 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2382843
21 January 2005
COC-MODU Annual
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2278431
20 October 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2227789
15 July 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2139649
10 December 2003
COC-MODU Renew
Type not classified · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1957312
28 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1764290
26 January 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1735486
20 December 2002
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1721513
26 February 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1635890
10 December 2001
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473741
1 December 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772679
29 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1070070
20 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1063813
24 July 2000
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1053069
27 April 2000
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 817351
25 February 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815950
14 December 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1397351
20 October 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 41912
12 August 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 54691
7 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806562
26 January 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375237
7 October 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 775789
10 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774663
19 May 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1096754
28 February 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409646
23 August 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1090932
5 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088347
3 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 71067
13 May 1996
Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404187
7 February 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1394475
27 September 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1440983
21 August 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 873584
18 July 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427087
6 April 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1407457
3 April 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 9741
3 April 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 36360
24 February 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1363199
17 February 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 845267
15 September 1994
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 870185
15 September 1994
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1178571
5 July 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 82196
26 April 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1169268
8 March 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1164999
28 February 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 55545
27 February 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 94102
11 February 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1443437
7 September 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1139991
19 August 1993
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1417539
9 April 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353428
22 March 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 675282
21 March 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 99876
15 December 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 841730
14 July 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1267760
29 April 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393855
5 March 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1009287
13 February 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 944212
17 December 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1260109
2 December 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 940346
18 October 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 940461
16 September 1991
Examination of Repairs · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 935766
12 July 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1245263
10 June 1991
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1215241
17 May 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1244565
10 May 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1214362
10 May 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1221751
10 May 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1239954
10 April 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1238133
6 November 1990
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 931514
6 November 1990
Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1234951
24 August 1990
Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1220636
12 April 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1220771
20 February 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 910732
18 April 1989
Examination of Repairs · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1196564
8 March 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1036834
8 March 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1044453
24 October 1988
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1202662
8 July 1988
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 897992
28 May 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1205061
13 May 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1349517
11 May 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1041657
2 March 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1031145
11 September 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314359
9 March 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327556
5 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317700
15 April 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991503
15 March 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991771
6 March 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 992901
5 March 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1296642
28 February 1986
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 989214
19 August 1985
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1295139
1 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283041
31 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286795
11 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974984
22 February 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1272141
16 February 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1271170
20 September 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1275435
28 July 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968419
3 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964336
13 April 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277568
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 December 2005
Resolved
Install new co2 extinguishers and or repair as per locations specified in service contract.
Due 6 January 2006
Resolved 5 January 2006
Resolution: Installed new co2 extinguishers in various locations specified.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 6 December 2005
Resolved
Mount brackets to portable fire extinguishers as per service report dated 10/26/05.
Due 6 January 2006
Resolved 21 December 2005
Resolution: Brackets were mounted and marked proprly.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 December 2005
Resolved
Hydro test specified co2 cylinders from report dated 10/26/05.
Due 6 January 2006
Resolved 21 December 2005
Resolution: All co2 cylinders specified were serviced by this date.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 6 December 2005
Resolved
Recharge or replace as per Hiller service contract dated 10/26/05.
Due 6 January 2006
Resolved 21 December 2005
Resolution: Replaced extinguishers.
Fire Fighting › Fire Hydrants › Location/Position
Issued 6 December 2005
Resolved
Mark fire stations as per Hiller service report dated 10/26/05
Due 6 January 2006
Resolved 21 December 2005
Resolution: Marked all fire stations appropriately as per report.
Fire Fighting › Fire Hoses › Condition
Issued 6 December 2005
Resolved
Renew deteriorated hose rack for station #23 as per service report.
Due 6 January 2006
Resolved 21 December 2005
Resolution: Replaced hose rack as per service report.
Fire Fighting › Fire Hoses › Condition
Issued 6 December 2005
Resolved
Renew fire hoses as per Hiller service report.
Condition: Unknown
Due 6 January 2006
Resolved 21 December 2005
Resolution: Hoses renewed as per service report.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 6 December 2005
Resolved
Install warning signs on all spaces protected by fixed systems as per service report.
Due 6 January 2006
Resolved 21 December 2005
Resolution: Warning signs installed on all spaces as per service report.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 December 2005
Resolved
Repair emergency light and gate interlock on personnel elevator as per MODU 1989 Ch 12-2.
Due 6 January 2006
Resolved 21 December 2005
Resolution: Repaired light and switch.
Fire Fighting › International Shore Connection › Not on Board
Issued 6 December 2005
Resolved
Type provided us unacceptable. as per 89 MODU 9.4.22
Due 6 January 2006
Resolved 21 December 2005
Resolution: Provided appropriate ISC.
Fire Fighting › Fire Main › Valves
Issued 6 December 2005
Resolved
Prove operation of fire main isolation valves IAW Modu code 9.4.14
Condition: Improper/Lack of Maintenance
Due 6 January 2006
Resolved 21 December 2005
Resolution: All valves freed and operating properly.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 6 December 2005
Resolved
Provide a statement of fact from the vessels classification society attesting to compliance with the applicable anchoring arrangements for column stabilized units as required b 1989 MODU Code 4.11
Action required: 705 - Other - as specified
Due 6 January 2006
Resolved 19 December 2007
Fire Fighting › Fire Hoses › Condition
Issued 10 December 2003
Resolved
Have NON-collapsable Foam Fire hose HYDRO-Tested
Due 17 January 2004
Resolved 17 January 2004
Resolution: faxed a report to MSU Galveston
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 10 December 2003
Resolved
Liberian Registry certificate was not on board. Have originial placed on vessel.
Due 17 January 2004
Resolved 17 January 2004
Resolution: Placed on board vessel.
Unknown
Issued 14 December 1999
Resolved
PROVIDE LETTER OF EVIDENCE OF SATISFACTION OF ABS DEFICIENCY'S AS SUPPLEMENT M26898(MODU CODE CERTIFICATE) DATED 11DEC99
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Unknown
Issued 14 December 1999
Resolved
SUBMIT OPERATIONS MANUAL,AFTER FINAL FLAG APPROVAL/ACCEPTANCE TO COGNIZANT OCMI FOR REVIEW
Condition: Unknown
Due 30 May 2000
Resolved 29 March 2000
Unknown
Issued 14 December 1999
Resolved
PROVIDE ANY EXEMPTIONS FROM MODU REQUIREMENTS TO COGNIZANT OCMI FOR EVALUATION WITH REGARD TO OPTION "C" LOC
Condition: Unknown
Due 11 March 2000
Resolved 29 March 2000
Lifesaving
Issued 26 January 1998
Resolved
CONDUCT OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR UNDER A LOAD OF 1.1 TIMESTHE TOTAL MASS OF THE LIFEBOAT WHEN LOADED WITH ITS FULL COMPLEMENT OF PERSONS AND EQUIPMENT (46 CFR 109.301).
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Electrical
Issued 28 February 1997
Resolved
PROPERLY SECURE ELECTRICAL WIRING AND LOOSE JUNCTION BOXES THROUGHOUT RIG WITH PROPER METAL BANDING.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Deck/Cargo
Issued 28 February 1997
Resolved
CONDUCT GAUGINGS ON DRILL FLOOR AIR RECEIVER. PROVIDE DOCUMENTATION OF ORIGINAL AIR RECEIVER PLATE THICKNESS.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Lifesaving
Issued 28 February 1997
Resolved
MAKE REVISIONS TO POLICY TO COMPLY WITH REVISIONS TO 46 CFR 107-109. REFERENCE WORKLIST ISSUED TO OIM ON 28FEB97 AND FEDERAL REGISTER, VOLUME 61, NO. 98, DATED 20MAY96.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Accommodation/Occupational Safety
Issued 7 February 1996
Resolved
CONDUCT TEST OF SAFETY RELIEF VALVES ON THE TWO LARGE AIR RECEIVERS AS PER ITEM #3.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Electrical
Issued 7 February 1996
Resolved
CONDUCT OPERATIONAL TEST OF VESSELS MAIN GENERATOR PRIME MOVERS , OVERSPEED, LOW LUBE OIL AND HIGH TEMP ALARMS/TRIPS, AND REVERSE CURRENT TRIPS.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Accommodation/Occupational Safety
Issued 7 February 1996
Resolved
OPEN, CLEAN, GAS FREE, AND MAKE READY FOR INTERNAL STRUCTURE EXAMINATION, THE VESSELS SIX DRY BULK TANKS.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Electrical
Issued 7 February 1996
Resolved
CONDUCT OPERATIONAL TEST OF VESSELS REMOTE STOPS FOR VENTILATION, EMD AND ETC._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Electrical
Issued 7 February 1996
Resolved
CONDUCT TEST OF VESSELS TOTAL RIG SHUTDOWN SYSTEM.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Accommodation/Occupational Safety
Issued 7 February 1996
Resolved
OPEN AND MAKE READY FOR INTERNAL EXAMINATION TTHE VESSELS TWO LARGE AIR RECEIVERS, LOCATED UNDER DRILL FLOOR AND OVERHEAD OF COMPRESSOR ROOM.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Construction/Loadline
Issued 27 September 1995
Resolved
MAINTAIN TEMPORARY REPAIRS AS PER ABS LETTER DATED 07 SEP 95 UNTIL PERMANENT REPAIRS CAN BE MADE TO WATER TIGHT BULKHEAD BETWEEN TANKS S-5 ANDS-6 IN STBD FOOTING. TO BE COMPLETED AT NEXT DRY DOCK, BUT NOT LATER THAN 31 MAR 96.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Deck/Cargo
Issued 6 April 1995
Resolved
MAKE REPAIRS TO PORT CRANE AND CONDUCT TEST IAW ICGB REQUIREMENTS IN THE PRESENT OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Electrical
Issued 24 February 1995
Resolved
Conduct operational test of vessel main generator.
Condition: Unknown
Due 24 March 1995
Resolved 10 April 1995
Construction/Loadline
Issued 24 February 1995
Resolved
Adjust water tight door dogs to pump rooms, replace missing dog wrenches and gasket to stbd aft pump room w/t door.
Condition: Unknown
Due 24 February 1995
Resolved 10 April 1995
Construction/Loadline
Issued 24 February 1995
Resolved
Provide and apply non-skid surface to vessel helo deck._x001C_
Condition: Unknown
Due 24 March 1995
Resolved 10 April 1995
Electrical
Issued 24 February 1995
Resolved
Provide and properly install missing sealant in ejs electrical fitting wererequired in h2s alarms
Condition: Unknown
Due 24 March 1995
Resolved 10 April 1995
Deck/Cargo
Issued 11 February 1994
Resolved
REPAIR/REPLACE CENTER DRAWWORKS BLOWER MOTOR AND PROVIDE BETTER SEALING AROUND ALL DRAWWORKS BLOWER COWLINGS.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Accommodation/Occupational Safety
Issued 11 February 1994
Resolved
INSTALL LOSS OF VENTILATION ALARM SENSORS IN SACK ROOM VICE MUDPIT AREA. ALARM MUST BE WIRED INDEPENDENTLY OF BLOWER CONTROLLERS IAW 46 CFR 108.175 (c)(1)(2)(3) and 108.185.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Electrical
Issued 11 February 1994
Resolved
INSTALL EXPLOSION PROOF FITTING ON SHAKER JUNCTION BOX.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Accommodation/Occupational Safety
Issued 11 February 1994
Resolved
MAKE PERMANENT REPAIRS TO MSD HOLDING TANK PIPING IN WAY OF SOFT PATCH AND PROCURE/FABRICATE NEW COVERS FOR TOP OF SYSTEM.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Electrical
Issued 11 February 1994
Resolved
REMOVE IMPROPER CABLE SPLICE IN CLASS I DIV, I AREA (SHALE SHAKER).
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Engineering
Issued 11 February 1994
Resolved
RENEW WASTED CONTAINMENT UNDER PORT CRANE DIESEL FUEL NOZZLE STATION.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Engineering
Issued 11 February 1994
Resolved
INSTALL REACH ROD OR OTHER MEANS OF REMOTE OPERATION TO SECURE FUEL AT STANDBY GENERATOR FUEL TANK.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Electrical
Issued 11 February 1994
Resolved
PROVE PROPER OPERATION OF AUXILIARY GENERATOR LOW OIL PRESSURE SHUTDOWN.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Documentation
Issued 19 August 1993
Resolved
PROVIDE DIVER'S REPORT AND VIDEOTAPES FOR ALL PHASES OF UNDERWATER SURVEY AND ABS SURVEY REPORT TO MSO NEW ORLEANS, LA.
Condition: Unknown
Due 7 September 1993
Resolved 7 September 1993
Construction/Loadline
Issued 19 August 1993
Resolved
MAKE ALL FOOTING BALLAST TANKS AVAILABLE FOR INTERNAL INSPECTION UPON COMPLETION OF INSTALLATION OF MANWAYS IN PUMPROOMS, AS ADDRESSED IN NOBLE DRILLING LETTER PD-93134 DATED 10JUN93.
Condition: Unknown
Due 19 August 1993
Resolved 19 August 1993
Electrical
Issued 9 April 1993
Resolved
CONDUCT LOAD TEST ON EMERGENCY GENERATOR. TEST EMERGENCY GENERATOR'S TRIPS(OVERSPEED AND LOW LUBE OIL SHUTDOWN).
Condition: Unknown
Due 2 June 1993
Resolved 3 June 1993
Engineering
Issued 13 February 1992
Resolved
Crop and renew wasted/pitted areas of fuel line piping and fire main pipingon main weather deck. Hydrostatically pressure test newly installed sections to 1.5 X MAWP in presence of Coast Guard marine inspector.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Fire Fighting
Issued 13 February 1992
Resolved
Complete installation of fire pump in Aft Leg (beneath Helo Deck). Prove proper operation in presence of Coast Guard marine inspector. Designate/provide two sources of firefighting water supplying adequate pressure and capacity until completion of this requirement.
Condition: Unknown
Due 27 February 1992
Resolved 6 March 1992
Electrical
Issued 13 February 1992
Resolved
Provide protective guard for substructure lighting fixture beneath port aft(Helo Deck is aft) corner of Drill Floor.
Condition: Unknown
Due 13 March 1992
Resolved 6 March 1992
Electrical
Issued 13 February 1992
Resolved
Complete repairs to electrical installations in Shaker and Mud Pit Area hazardous location. PRIOR TO ENGAGING IN DRILLING, these electrical installations must be inspected by a Coast Guard marine inspector.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Accommodation/Occupational Safety
Issued 13 February 1992
Resolved
Gage Drill Floor air receiver in way of pitting. Submit wastage report anddesign criteria to cognizant OCMI for determination of adequacy for service.
Condition: Unknown
Due 13 February 1992
Resolved 13 February 1992
Construction/Loadline
Issued 16 September 1991
Resolved
RENEW CORRODED MOUNTINGS FOR PUMP MOTOR ON TOP OF DEGASSOR IN SHAKER AREA._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Engineering
Issued 16 September 1991
Resolved
REPLACE WORN PINK FUEL TRANSFER HOSE ON STBD FUEL TRANSFER STATION_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Electrical
Issued 16 September 1991
Resolved
REPLACE BROKEN HAZARDOUS AREA LIGHT ABOVE SOUND POWERED PHONE IN SHAKER AREA._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Lifesaving
Issued 16 September 1991
Resolved
REPLACE GENERAL ALARM BELL ON DRILL FLOOR WITH GENERAL ALARM BELL APPROVED FOR HAZARDOUS LOCATIONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Electrical
Issued 16 September 1991
Resolved
RENEW CRACKED HAZARDOUS AREA LIGHT OVER PORT OUTBOARD MUD PIT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Lifesaving
Issued 16 September 1991
Resolved
REPLACE SPEAKER LOCATED IN DRILL HOUSE WITH SPEAKER APPROVED FOR CLASS I _x001C_ DIVISION II LOCATIONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Electrical
Issued 16 September 1991
Resolved
REPLACE SPEAKER LOCATED ON FORWARD BULKHEAD OF SHALE SHAKER WITH SPEAKER_x001C_ APPROVED FOR CLASS I DIVISION I LOCATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Engineering
Issued 16 September 1991
Resolved
REPLACE OR REPAIR CRACKED WHEEL ON PORT FUEL TRANSFER HOSE SHUT-OFF VALVE._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Lifesaving
Issued 12 July 1991
Resolved
PROVIDE USCG APPROVED PLANS FOR THE INSTALLATION OF PORT AND STARBOARD DAVIT LAUNCHED ESCAPE CAPSULE SYSTEMS._x001C_
Condition: Unknown
Due 12 July 1991
Resolved 12 July 1991
Construction/Loadline
Issued 17 May 1991
Resolved
MAKE PERMANENT REPAIRS TO THREE DAMAGED AREAS ALONG PORT AND STBD HORIZONTAL TRUSS MEMBERS.
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Electrical
Issued 10 April 1991
Resolved
PROVE OPERATION OF SAFETIES FOR ALL THREE MAIN GENERATORS.
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Navigation
Issued 10 April 1991
Resolved
PROVE OPERATION OF NAVIGATIONAL LIGHTING PANEL_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Electrical
Issued 10 April 1991
Resolved
RENEW FLAME SCREEN ON AUX. GENERATOR FUEL OIL DAY TANK_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Fire Fighting
Issued 10 April 1991
Resolved
PROVE OPERATION OF STANDBY FIRE PUMP
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Lifesaving
Issued 10 April 1991
Resolved
PROVIDED CARTRIDGES WTH CURRENT DATE FOR LINE THROWING APPLIANCE
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Fire Fighting
Issued 10 April 1991
Resolved
REPAIR FIRE MAINLINE FWD OR QUARTER ON MAIN DECK
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Electrical
Issued 20 February 1990
Resolved
PROVIDE AND TEST HIGH TEMPERATURE ALARM/TRIP FOR FOR EACH SCR MODULE. AS REQUIRED BY 46 CFR 111.33-7.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Electrical
Issued 20 February 1990
Resolved
LABEL SWITCH FOR FUEL TRANSFER TO EMERGENCY GENERATOR DAY TANK
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Electrical
Issued 20 February 1990
Resolved
LABEL/MARK LOCATION OF EMERGENCY GENERATOR FUEL SHUTOFF
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Electrical
Issued 20 February 1990
Resolved
REPAIR AND TEST REMOTE EMERGENCY SHUTDOWN OF DC POWER TO DRILLERS CONSOLE
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Lifesaving
Issued 20 February 1990
Resolved
CONDUCT FIRE AND ABANDON RIG DRILLS
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Fire Fighting
Issued 20 February 1990
Resolved
MISSING SPARE SCBA BOTTLES FOR EACH OF THE TWO FIREMAN'S OUTFITS
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Accommodation/Occupational Safety
Issued 20 February 1990
Resolved
HYDROSTATICALLY TEST AIR RECEIVER UNDER RIG FLOOR TO 1.25 MAWP
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Accommodation/Occupational Safety
Issued 20 February 1990
Resolved
PROVIDE NAMEPLATE OR DATA FOR AIR RECEIVER UNDER RIG FLOOR
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Construction/Loadline
Issued 20 February 1990
Resolved
REPAIR HYDRAULIC LINES TO BALLAST TANKS #5 AND #7 IN AFT PUMPROOM
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Electrical
Issued 20 February 1990
Resolved
REPAIR EMERGENCY LIGHTS IN AFT AND PORT PUMPROOMS
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Deck/Cargo
Issued 20 February 1990
Resolved
PROVIDE AN APPROPRIATE REFUELING APPARATUS FOR FORKLIFT
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Electrical
Issued 20 February 1990
Resolved
LABEL ALL BREAKERS ON EMERGENCY SWITCHBOARD
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Electrical
Issued 20 February 1990
Resolved
REPAIR AND TEST EMERGENCY GENERATOR FOR OVERSPEED, LOW LUBE OIL PRESSURE AND HIGH WATER TEMP FOR ALARMS AND SHUTDOWNS
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Lifesaving
Issued 20 February 1990
Resolved
HYDRO RELEASE STRAPS ON ALL LIFERAFTS HAVE IMPROPER TENSION
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Construction/Loadline
Issued 18 April 1989
Resolved
PRIOR TO NEXT RIG MOVE, MAKE PERMANENT REPAIRS TO DAMAGED TANKWALL AND AFFECTED INTERNAL STRUCTURAL MEMBERS IN THE AFT FOOTING BETWEEN TANK # A2 (POTABLE WATER) AND # A3 (SWB). CONTACT USCG MARINE SAFETY OFFICE PORT ARTHUR TEXAS WHEN REPAIRS ARE COMPLETED.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989
Construction/Loadline
Issued 8 July 1988
Resolved
EXAMINE OF THE NEXT RIG MOVE, THE BOTTOM OF THE FOOTING (3) FROM THE MUD LINE.
Condition: Unknown
Due 8 July 1988
Resolved 8 July 1988
Construction/Loadline
Issued 28 May 1988
Resolved
COMPLETE PERMANENT REPAIRS TO THE 5" STRUCTURAL COLUMN (PORT SIDE OR VERTICAL COLUMN DURING THE NEXT RIG MOVE OR BY THE DATE ABOVE, WHICHEVER ISFIRST.
Condition: Unknown
Due 28 May 1988
Resolved 28 May 1988
Electrical
Issued 2 March 1988
Resolved
REWIRE AS APPROPRIATE ALL PRESENTLY INAPPROPRIATELY WIRED LIGHTS AND JUNCTIONS IN HAZARDOUS LOCATIONS. THESE ITEMS WERE POINTED OUT TO [name withheld]. 46 CFR 111.80-5(B)(10)
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Electrical
Issued 2 March 1988
Resolved
SHOW SATISFACTORY OPERATIONS AND SUBSEQUENT SAFETY TESTS ON #2 ENG/GEN. 46 CFR 58.01-5
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Construction/Loadline
Issued 2 March 1988
Resolved
MAKE SELF-CLOSING DEVICE ON DOOR BETWEEN SACK ROOM AND MUD PITS OPERABLE. 46 CFR 108.175/46 CFR 111.92-9
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Electrical
Issued 2 March 1988
Resolved
PLACE BLANKS IN THE FOLLOWING ELECTRICAL PANELS: (A) EMERGENCY GENERATOR ROOM PANEL; (B) ELECTRIC SHOP LIGHTING PANEL. 46 CFR 111.50-10
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Construction/Loadline
Issued 2 March 1988
Resolved
PROVE SATISFACTORY OPERATION OF THE HIGH SEACHEST VALVE LOCATED IN THE PORTPUMP ROOM. 46 CFR 56.50-95
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Electrical
Issued 2 March 1988
Resolved
SHOW TRANSFORMERS ON AFT BULKHEAD ON DRILL FLOOR SATISFACTORY FOR CLASSIFIED LOCATION INSTALLATION. 46 CFR 111.80-5(B)(3)
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Electrical
Issued 2 March 1988
Resolved
APPROPRIATELY HAND ALL WIRING IN AND ABOUT RIG USING 5/8-INCH METAL NON-CORROSIVE STRAPS IN LIEU OF PRESENT PLASTIC TIE WRAPS, ESPECIALLY UNDERDRILL FLOOR. 46 CFR 111.60
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Documentation
Issued 9 March 1987
Resolved
PLACE OPERATING RESTALLTIONES STATEMENT CITED ON USCG CCGD8(MMT) LTR MI-6067 OF 18JAN84 AN ABS LOADLINE CERTIFICATE #NS-8010879-3. 46 CFR 1/2
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Documentation
Issued 9 March 1987
Resolved
PROVIDE EVIDENCE THAT VESSEL COMPLETED PERIODIC LOADLINE SURVEY FOR TIME FRAME OF DEC85 THRU JUNE86. 46 CFR 42
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Documentation
Issued 9 March 1987
Resolved
PROVIDE ONBAORD A COPY OF APPROVED CONSTRUCTION PORTFOLIO. 46 CFR 107.303 (HH)
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Lifesaving
Issued 9 March 1987
Resolved
PROVIDE ONBOARD CURRENT INFLATTABLE LIFERAFT SERVICE CERTIFICATE. 46 CFR 108.505
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Fire Fighting
Issued 9 March 1987
Resolved
PROVIDE APPROVED COPY OF FIRE CONTROL PLAN WHICH ACCURATELY REFFFLECTS LOCATION OF ALL HYDRANTS AND FIRE STATION NUMBERS. 46 CFR 107.705(RR)
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Electrical
Issued 9 March 1987
Resolved
SECURE HAZARDOUS LOCATION LIGHTS ABOVE DESILTER. 46 CFR 111(OLD J)
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Lifesaving
Issued 9 March 1987
Resolved
PROVIDE EVIDENCE THAT ZODIAC RESCUE BOAT IS COAST GUARD APPROVED. NVIC 4-78 3.D.8
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Navigation
Issued 9 March 1987
Resolved
MAKE OPERABLE STERN LIGHT AND RESTRICTED IN ABILITY TO MANEUVER LIGHTS. 33 CFR SUBCHAPTER D
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Lifesaving
Issued 9 March 1987
Resolved
PROVIDE ONE RING BUOY ON STBD SIDE AND ONE RING BUOY ON AFT SIDE WITH BUOYANT LINE REQUIRED BY 46 CFR 108.515(.)
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Accommodation/Occupational Safety
Issued 9 March 1987
Resolved
PROVIDE 3 ADDITIONAL FOUR INCH BANDAGE COMPRESSERS.
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Fire Fighting
Issued 9 March 1987
Resolved
CONDUCT HYDROSTATIC TEST OF PAINT LOCKER CO2 CYLINDER LOCATED ON LEFT HAND SIDE OF PAINT LOCKER. 46 CFR 147
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Deck/Cargo
Issued 9 March 1987
Resolved
LAVEL ALL CONTROLLS IN CRANES. 46 CFR 108.601
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Accommodation/Occupational Safety
Issued 9 March 1987
Resolved
PRIOR TO COMENCING DDRILLING OPERATIONS TEST MUD PUMP RELIEF VALVES.
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Construction/Loadline
Issued 9 March 1987
Resolved
REPAIR/REPLACE ALL BURNED OUT INDICATOR LAMPS ON BALLAST CONTROL BOARD.
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Accommodation/Occupational Safety
Issued 9 March 1987
Resolved
PROVIDE HOT WATER TANKS WITH RELIEF VALVES NOT TO EXCEED 100PSI/210 DGRS F OR CONDUCT INTERNAL EXAM OF SAME.
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Electrical
Issued 9 March 1987
Resolved
MAKE AVAILABLE FOR TESTING IN PRSENCE OF COAST GUARD THE OVERSPEED TRIP ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Electrical
Issued 9 March 1987
Resolved
MAKE OPERABLE THREE EXPLOSION PROOF LIGHTS IN WAY OF SHALE SHAKER AREA.
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Electrical
Issued 9 March 1987
Resolved
SUPPORT ALL LOOSE ELECTRICAL CABLES IN WAY OF SHALE SHAKER AREA.
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Construction/Loadline
Issued 9 March 1987
Resolved
PLUG ALL OPEN THROUGH BULKHEAD PENTRATIONS OF SHALE SHAKER AREA IN WAY OF SACK ROOM BULKHEAD AND OVERHEAD DIRECTLY ABOVE SHAKERS.
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Electrical
Issued 9 March 1987
Resolved
SECURE ALL ELECTRICAL CABLES IN CABLE TRAYS LEADING FROM MAIN DECK TO TOP OF ALL FOOTING COLUMNS.
Condition: Unknown
Due 9 March 1987
Resolved 9 March 1987
Deck/Cargo
Issued 5 March 1986
Resolved
PROVIDE DOCUMENTATION OF THE COMPLETION OF THE ANNUAL CRANE SURVEY BY ABS OR ICGB.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Construction/Loadline
Issued 5 March 1986
Resolved
MAKE PERMANENT REPAIRS TO REMOTE HYDRAULIC CLOSURE DEVICE IN LIEU OF TEMPO-RARY HAND WHEELS ON THE #8 BALLAST VALVE IN THE STARBOARD PUMP ROOM.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Construction/Loadline
Issued 5 March 1986
Resolved
MAKE PERMANENT REPAIRS TO REMOTE HYDRAULIC CLOSURE DEVICE IN LIEU OF TEMPO-RARY HAND WHEELS ON THE FOLLOWING PORT PUMP ROOM VALVES: 1. #3 BALLAST VAL-VE. 2. JETTING SYSTEM VALVE. 3. INDUCTOR FEED VALVE.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Unknown
Issued 5 March 1986
Resolved
MAKE THE DRILL FLOOR AND ASSOCIATED SYSTEMS ON THE DRILL FLOOR AVAILABLE FOR INSPECTION BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Unknown
Issued 5 March 1986
Resolved
REPAIR/REPLACE THE BACK-UP ALARM ON FORK LIFT.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986
Resolved
ADJUST FOR CLOSURE THE MAIN DECK ACCESS DOOR (STARBOARD SIDE) TO THE GENER-ATOR ROOM.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Construction/Loadline
Issued 5 March 1986
Resolved
MAKE PERMANENT REPAIRS TO REMOTE HYDRAULIC CLOSURE DEVICE IN LIEU OF TEMPO-RARY HAND WHEELS ON THE FOLLOWING AFT PUMP ROOM VALVES: 1. #1 SEA CHEST VALVE. 2. #4 BALLAST VALVE. 3. #5 BALLAST VALVE. 4. #6 BALLAST VALVE.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986
Resolved
REINSTATE THE AUTO-CLOSING DEVICE TO THE QUARTERS STAIRTOWER DOOR.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986
Resolved
ADJUST FOR CLOSURE, THE SCR/GENERATOR ROOM DOOR.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986
Resolved
REPLACE OR HAVE A HYDROSTATIC TEST CONDUCTED ON THE PROPELLANT TANKS OF THEHELIPORT BV SEMI-PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Navigation
Issued 5 March 1986
Resolved
INSTALL THE PROPER LIGHT BULBS IN THE PERKO SIDE-NAVIGATION LIGHTS (PORT AND STARBOARD).
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986
Resolved
REPAIR/REPLACE THE DOOR BETWEEN THE BAG ROOM AND THE MUD PUMP ROOM.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986
Resolved
REINSTATE THE AUTO-CLOSING DEVICE AND ADJUST THE DOOR FOR PROPER CLOSURE ATTHE MAIN COMPRESSOR ROOM ACCESS.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Unknown
Issued 5 March 1986
Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS IN THE PRECENSE OF A USCG MARINE INS- PECTOR PRIOR TO COMMENCING DRILLING OPERATIONS AND IN NO CASE LATER THAN 05APR86.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Unknown
Issued 28 February 1986
Resolved
OPEN FOR A SATISFACTORY INTERNAL EXAMINATION BY A CG MARINE INSPECTOR THE LOWER AFT SEA CHEST VALVE.
Condition: Unknown
Due 28 February 1986
Resolved 28 February 1986
Construction/Loadline
Issued 28 February 1986
Resolved
REPAIR AND CONDUCT A SATISFACTORY HYDROSTATIC TEST ON THE FRACTURED WELD ON BULKHEAD SEAM BETWEEN TANKS A2 AND A3.
Condition: Unknown
Due 28 February 1986
Resolved 28 February 1986
Construction/Loadline
Issued 28 February 1986
Resolved
CONDUCT A SATISFACTORY VISUAL UNDERWATER EXAMINATION IN THE PRESENCE OF A CG MARINE INSPECTOR OF THE BOTTOM PLATING AND THE SKIRT ON ALL 3 FOOTINGS, AND CONDUCT A VISUAL EXAM OF THE HIGH STRESS WELD ON THE PORT FOOTING.
Condition: Unknown
Due 28 February 1986
Resolved 28 February 1986
Unknown
Issued 1 August 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU, TRANSWORLD 68, CG027797 AND ARE TO BE COMPLIED WITH BY 31 AUG 84.
Condition: Unknown
Due 1 August 1984
Resolved 1 August 1984
Electrical
Issued 1 August 1984
Resolved
PROVIDE COAST GUARD APPROVED HAZARDOUS LOCATION PLAN ON BOARD.
Condition: Unknown
Due 1 August 1984
Resolved 1 August 1984
Construction/Loadline
Issued 1 August 1984
Resolved
PROVIDE THREE VALVE POSITION INDICATOR MICRO SWITCHES FOR BALLAST VALVE ACCUATORS ON PORT NUMBER 2 SUCTION VALVE, PORT NUMBER 1 SEACHEST SUCTION VALVE, PORT NUMBER 2 SEACHEST SUCTION VALVE 46 CFR 56.50.
Condition: Unknown
Due 1 August 1984
Resolved 1 August 1984
Navigation
Issued 1 August 1984
Resolved
REPAIR OR REPLACE THE STERN LIGHT COLREGS.
Condition: Unknown
Due 1 August 1984
Resolved 1 August 1984
Navigation
Issued 31 July 1984
Resolved
REPAIR OR REPLACE STERN LIGHT. 72 COLREGS
Condition: Unknown
Due 31 July 1984
Resolved 31 July 1984
Unknown
Issued 31 July 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE M/V TRANSWORLD 68, O.N. CG027797.THE FOLLOWING DEFICIENCIES ARE TO BE COMPLIED WITH BY 31AUG84.
Condition: Unknown
Due 31 July 1984
Resolved 31 July 1984
Documentation
Issued 31 July 1984
Resolved
PROVIDE COAST GUARD APPROVED HAZARDOUS LOCATION PLAN ON BOARD. NVC 4-78.
Condition: Unknown
Due 31 July 1984
Resolved 31 July 1984
Construction/Loadline
Issued 31 July 1984
Resolved
PROVIDE THREE VALVE POSITION INDICATOR MICROSWITCHES FOR BALLAST VALVE ACCUATORS ON PORT #2 SUCTION VALVE, PORT #1 SEACHEST SUCTION VALVE, PORT #2 SEACHEST SUCTION VALVE.
Condition: Unknown
Due 31 July 1984
Resolved 31 July 1984
Lifesaving
Issued 11 April 1984
Resolved
PROVIDE INFLATABLE LIFE RAFT FOUR AND FIVE WITH WEAK LINK CONNECTIONS 46CFR107.231
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Unknown
Issued 11 April 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL TRANSWORLD 68 CG027797
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Accommodation/Occupational Safety
Issued 11 April 1984
Resolved
REPAIR FLOOR GRATING IN MUD ROOM. 46CFR108.113
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Lifesaving
Issued 11 April 1984
Resolved
REMOVE EMBARKATION LADDERS (THROW DOWN TYPE). OR MOVE TO WHERE THEY ARE SUPPORTED BY A VERTICAL SUFRACE; OR OBTAIN COMMANDANT APPROVAL, AS PER
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Electrical
Issued 11 April 1984
Resolved
MAKE ALL ELECTRICAL FIXTURES SAFE FOR HAZARDOUS AREAS AS DEPICTED IN APPROVED HAZARDOUS LOCATION PLAN. 46CFR111.105
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Electrical
Issued 11 April 1984
Resolved
PROVIDE BLANKS IN EMERGENCY SWITCHBOARD AS NECESSARY. 46CFR111.30
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Fire Fighting
Issued 11 April 1984
Resolved
ESTABLISH AND MAINTAIN A RECORD OF FIRE EXTINGUISHER SERVICING BY ITEM, AS PER 46CFR109.435.
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Construction/Loadline
Issued 11 April 1984
Resolved
PROVIDE SHAFT COUPLING GUARDS ON BALLAST PUMPS WHERE MISSING. 46CFR56.50
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Electrical
Issued 11 April 1984
Resolved
REPAIR EMERGENCY LIGHT AT FORWARD END OF MUD PUMP ROOM. 46CFR112
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Construction/Loadline
Issued 11 April 1984
Resolved
PROPERLY REWIRE PORT BILGE ALARM. 46CFR111. 60
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Construction/Loadline
Issued 11 April 1984
Resolved
ADJUST DOGGING MECHANISM ON HATCH BETWEEN MUD AND SACK ROOM TO FREE OPERATION. 46CFR108.114
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Fire Fighting
Issued 11 April 1984
Resolved
PROVIDE A GENERAL ALARM BELL AUDIABLE ON DECK IN THE VICINITY OF THE AIR- X-CHANGER UNITS. 46CFR113.25
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Construction/Loadline
Issued 11 April 1984
Resolved
PROVIDE CLEAR LEGIBLE LABELING OF ALL VALVES IN BALLAST PUMP ROOM. 46CFR56.50-50
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Construction/Loadline
Issued 11 April 1984
Resolved
REPAIR FLOW COUNTER ON CONTROL CONSOLE FOR AFTER PUMP ROOM. 46CFR111.60
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Electrical
Issued 11 April 1984
Resolved
PERMANENTLY WIRE INTERCOM STATIONS THROUGHOUT VESSEL. 46CFR111.60
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Electrical
Issued 11 April 1984
Resolved
PROPERLY ROUTE AND RESTRAIN ELECTRICAL CABLE RUNNING UP STARBOARD SIDE OF DERRICK LAY DOWN RACK. 46CFR111.60
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Construction/Loadline
Issued 11 April 1984
Resolved
MAKE WATERTIGHT DOOR BETWEEN SACK ROOM AND MUD ROOMS SELF CLOSING AND GAS TIGHT. 46CFR111.105
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Fire Fighting
Issued 11 April 1984
Resolved
PROVIDE GENERAL ALARM BELL TO ALERT PERSONNEL IN AIR COMPRESSOR ROOM AND ADJACENT STORE ROOM. 46CFR113. 25
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Lifesaving
Issued 11 April 1984
Resolved
(CONT) 46 CFR108.525.
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Deck/Cargo
Issued 11 April 1984
Resolved
PROVIDE LABELS FOR CONTROLS ON ALL CRANES. 46CFR107.258
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Navigation
Issued 11 April 1984
Resolved
REPAIR WIRING FOR STERN LIGHT. 46CFR111.75
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Navigation
Issued 11 April 1984
Resolved
REPAIR SOUND POWERED TELEPHONE TO AFTER BALLAST PUMP ROOM 46CFR113
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Construction/Loadline
Issued 11 April 1984
Resolved
REPAIR AND MAKE OPERABLE ALL VALVE POSITION INDICATOR SWITCHES AND CONTROL CONSOLE LIGHTS FOR THE BALLAST CONTROL SYSTEM. 46CFR56.50-50
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Construction/Loadline
Issued 11 April 1984
Resolved
ADJUST SEACHEST SUCTION NO. 2 VALVE IN AFTER PUMP ROOM TO ELIMINATE JARRINGUPON OPENING. 46CFR56.56.50-50
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Documentation
Issued 11 April 1984
Resolved
PORVIDE COAST GUARD APPROVED HAZARDOUS LOCATION PLAN ON BOARD 46CFR111.105
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Unknown
Issued 13 April 1982
Resolved
OBTAIN THE FOLLOWING DOCUMENTS: (A) STABILITY LETTER, (B) OPERATING MANUAL, (C) LOADLINE CERTIFICATE, (D) CLASSIFICATION DOCUMENT.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
TEST AND RECORD DATA FOR FUEL HOSES IN ACCORDANCE WITH 33 CFR 154.500.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
SERVICE THE HYDROSTATIC RELEASES FOR ALL LIFERAFTS.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
REPLACE THE DEFECTIVE RING BUOY LOCATED ON THE PORT SIDE OF THE RIG.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
LABLE THE LIFERAFT STATION IN ACCORDANCE WITH THE STATION BILL.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
REMOVE ALL DEAD END WIRES FROM THE EMERGENCY GENERATOR.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
TEST THE OVERSPEED TRIP ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
STENCIL THE GENERAL ALARM BELLS THROUGHOUT THE ENGINEERING SPACES.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
REPAIR THE FAULTY ALARM PANEL ON THE #3 MAIN GENERATOR.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
REMOVE THE SHUT-OFF VALVE IN THE POTABLE WATER TANK LOCATED BETWEEN THE TANK AND THE RELIEF VALVE.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
PLACE SAFETY GUARDS ON BOTH POTABLE WATER PUMP BOLTS AND PULLEYS.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
REPAIR OR REPLACE THE RELIEF VALVE ON THE FIRE MAIN AND PROPERLY ADJUST SO AS NOT TO EXCEED THE PIPING DESIGN PRESSURE.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
PLACE 3 ADDITIONAL GENERAL ALARM BELLS ON THE MAIN DECK.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
PLACE A GENERAL ALARM BELL IN THE WELDING SHOP.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
PROVIDE CAPACITY CHART FOR THE FORKLIFT.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
INSTALL AN ADDITIONAL HAND RAIL SECTION UNDER THE DRILL RIG FLOOR ON THE CATWALK TO THE AIR RECEIVER.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
PREPARE ALL AIR RECEIVERS FOR INTERNAL INSPECTION AND HYDROSTATIC TESTING.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
PROVE THE LUBE OIL ALARMS ON ALL 3 MAIN GENERATORS.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982
Unknown
Issued 13 April 1982
Resolved
PROVIDE A WIND DIRECTINAL DEVICE FOR THE HELIPORT.
Condition: Unknown
Due 13 April 1982
Resolved 13 April 1982