MAURY USCG vessel records Sign in
← All vessels

STRETCH DUCK 16

STRETCH DUCK 16 is a 1944 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2002, most recently in August 2019, along with 12 deficiencies — 2 with no resolution recorded —.

Records from 2002 to 2019. Most recent: inspection, 19 August 2019.

Built
1944
Last inspected
19 August 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA7100
511655
Flag
UNITED STATES
—
Maury page id
psix-511655

Inspections, by type

…past their stated due date1
Years with a record 15 calendar years (2002–2019)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

19 August 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6787990
14 June 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6760640
8 February 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6622359
22 August 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6519698
21 March 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6388101
3 January 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6331868
14 February 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6090455
18 February 2016 COI Inspection · Administrative Inspection · Hull Examination · Plan Review "T" Boat · Deficiency Check · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5819729
15 August 2014 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4955738
21 September 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4166574
5 October 2010 Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3865058
2 March 2010 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3685572
9 December 2009 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3653013
29 April 2009 Internal Structural Exam · Hull Examination · Annual Inspection · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3454429
26 March 2008 Annual Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3162959
18 April 2007 Hull Examination · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2889373
17 May 2006 Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2646582
3 April 2006 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2615325
8 March 2005 Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2293730
1 March 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2301508
25 February 2004 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2000572
16 December 2003 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1965171
15 April 2003 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1739809
22 January 2003 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1733960
4 February 2002 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1483816

Deficiency record · 12

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 February 2019 No resolution recorded
Prior to resuming vessel operations, company must demonstrate compliance with new Conditions of Operation listed on Amended COI to the satisfaction of attending Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Bilge Water Management System › Piping
Issued 21 March 2018 No resolution recorded
Bilge piping and GPM rate is not in compliance with MSC Letter E1-0504811. Vessel to operate with 2 total hand bilge pumps and will require manning as appropriate. This is to be corrected by 2019 operating season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2018 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Gasket
Issued 16 March 2016 Resolved
Leak found at steering box penetration.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2016
Resolved 8 April 2016
Resolution: Received satisfactory verification that leak is repaired.
Engineering › Bilge Water Management System › Piping
Issued 8 June 2011 Resolved
Ensure the electrical bilge pump flaps automatically close.
Condition: Improper/Lack of Maintenance
Due 8 July 2011
Resolved 23 June 2011
Resolution: Flap modified to ensure automatic closure.
Stability › Watertight Integrity › General
Issued 8 June 2011 Resolved
Provide a copy of spreadsheet showing all modifications completed during refurbishment and weight tickets to compare with ongoing parent hull weight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2011
Resolution: Vessel rep provided documenation of modifications and weight tickets showing weight changes within 2% allowance.
Construction/Loadline › Hull › Weld
Issued 8 June 2011 Resolved
External ribs on stern wheel wells, weld bend stress relief cuts (double side continuous).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2011
Resolved 23 June 2011
Resolution: Ribs welded both sides.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 March 2010 Resolved
Properly provide proof that 35 pound CO2 cylinder has been properly serviced.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2011
Resolution: Viewed service documentation.
Engineering › Pressure Vessel › Marking and Stamping
Issued 9 December 2009 Resolved
Prove proper installation of pressure vessels used for axel housing low air pressurization system.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 8 June 2011
Resolution: Pressure vessel removed, axel housing vented to atmosphere.
Construction/Loadline › Hull › Hull Plating
Issued 29 April 2009 Resolved
Provide repair proposal and make permanent repairs to holed stbd stern quarter side shell.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2009
Resolved 8 June 2011
Resolution: Credited dry dock exam. All repairs completed.
Fire Fighting › Fixed Fire Detection System
Issued 25 February 2004 Resolved
Replace faulty vapor detector in the bilge compartment. LEGACY COMPONENT DESC: Vapor Detector
Condition: Unknown
Due 25 February 2004
Resolved 25 February 2004
Resolution: New vapor detector installed.
Engineering › Gasoline Engine (propulsion)
Issued 16 December 2003 Resolved
Properly install engine space ventilation blower as per 46 CFR 182.460. LEGACY COMPONENT DESC: Ventilation
Condition: Improper Installation
Due 17 March 2004
Resolved 25 February 2004
Construction/Loadline › Hull
Issued 22 January 2003 Resolved
Make permanent repairs to both front exhaust area's prior to carrying passengers. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.